ENTRY T0207 20020924 0000T020700000001 SUBENT T0207001 20020924 0000T020700100001 BIB 10 22 T020700100002 INSTITUTE (1USAOSU,1USAKTY,1USAINU) T020700100003 REFERENCE (J,PR/C,37,503,198802) T020700100004 AUTHOR (H.J.Hausman,S.L.Blatt,T.R.Donoghue,J.Kalen,W.Kim, T020700100005 D.G.Marchlenski,T.W.Rackers,P.Schmalbrock,M.A.Kovash, T020700100006 A.D.Bacher) T020700100007 TITLE Ground state proton capture reactions from 20 to 100 T020700100008 MeV T020700100009 FACILITY (CYCLO,1USAINU) T020700100010 METHOD (SITA) T020700100011 Time-of-flight used to reject neutron events. T020700100012 DETECTOR (NAICR) NaI(Tl) crystal surrounded by plastic annulus, T020700100013 which served as an anticoincidence shield for T020700100014 background and cosmic-ray rejection and also gave a T020700100015 measure of escaped radiation from NaI crystal. T020700100016 CORRECTION Corrected for T020700100017 . pulse pile-up, T020700100018 . computer dead time, T020700100019 . events lost due to raely occuring cyclotron radio T020700100020 frequency phase shifts, T020700100021 . the resum factor. T020700100022 STATUS No reply received from H. Hausman to author proof. T020700100023 HISTORY (20020805C) Converted from data set O0264 and updated. T020700100024 ENDBIB 22 0 T020700100025 NOCOMMON 0 0 T020700100026 ENDSUBENT 25 0 T020700199999 SUBENT T0207002 20020805 0000T020700200001 BIB 4 14 T020700200002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) T020700200003 SAMPLE Solid boron targets, enriched to 97.1% 11B. Target T020700200004 thicknesses ranged from 25-35 mg/cm2. T020700200005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700200006 associated with T020700200007 . stripping the spectra (<15%), T020700200008 . resum correction, including uncertainty in detector T020700200009 efficiency (<15%), T020700200010 Uncertainties associated with target thickness and T020700200011 uniformity, charge collections, and solid angle are T020700200012 small by comparison. T020700200013 Data-point reader uncertainty on incident energy 0.3 T020700200014 MeV. T020700200015 STATUS (CURVE) Scanned from Fig. 3(a) in reference at CAJAD. T020700200016 ENDBIB 14 0 T020700200017 COMMON 3 3 T020700200018 ANG E-LVL DATA-ERR T020700200019 ADEG MEV PER-CENT T020700200020 60. 0. 20. T020700200021 ENDCOMMON 3 0 T020700200022 DATA 2 12 T020700200023 EN DATA T020700200024 MEV MU-B/SR T020700200025 21.36 0.85 T020700200026 27.11 0.98 T020700200027 28.93 0.77 T020700200028 32.76 0.83 T020700200029 36.49 0.65 T020700200030 40.29 0.66 T020700200031 50.89 0.30 T020700200032 60.14 0.241 T020700200033 70.07 0.081 T020700200034 80.69 0.073 T020700200035 91.02 0.09 T020700200036 100.4 0.06 T020700200037 ENDDATA 14 0 T020700200038 ENDSUBENT 37 0 T020700299999 SUBENT T0207003 20020805 0000T020700300001 BIB 4 16 T020700300002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) T020700300003 SAMPLE Solid boron targets, enriched to 97.1% 11B. Target T020700300004 thicknesses ranged from 25-35 mg/cm2. T020700300005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700300006 associated with T020700300007 . stripping the spectra (<15%), T020700300008 . resum correction, including uncertainty in detector T020700300009 efficiency (<15%), T020700300010 Uncertainties associated with target thickness and T020700300011 uniformity, charge collections, and solid angle are T020700300012 small by comparison. T020700300013 Data-point reader uncertainty on angle 0.5 degrees. T020700300014 MeV. T020700300015 Data-point reader uncertainty on data 10%. T020700300016 STATUS (CURVE) Scanned from Fig. 3 and 4 in reference at T020700300017 CAJAD. T020700300018 ENDBIB 16 0 T020700300019 COMMON 2 3 T020700300020 E-LVL DATA-ERR T020700300021 MEV PER-CENT T020700300022 0. 20. T020700300023 ENDCOMMON 3 0 T020700300024 DATA 3 16 T020700300025 EN ANG DATA T020700300026 MEV ADEG MU-B/SR T020700300027 28.35 30.1 0.82 T020700300028 28.35 45.2 1.27 T020700300029 28.35 71. 1.2 T020700300030 28.35 96.1 0.78 T020700300031 28.35 111. 0.058 T020700300032 28.35 132. 0.218 T020700300033 28.35 147. 0.145 T020700300034 49.2 25.3 0.29 T020700300035 49.2 30.9 0.285 T020700300036 49.2 45.0 0.41 T020700300037 49.2 60.8 0.32 T020700300038 49.2 84.6 0.183 T020700300039 49.2 90.2 0.153 T020700300040 49.2 110.0 0.064 T020700300041 49.2 131.4 0.0109 T020700300042 49.2 149.5 0.0077 T020700300043 ENDDATA 18 0 T020700300044 ENDSUBENT 43 0 T020700399999 SUBENT T0207004 20020805 0000T020700400001 BIB 7 10 T020700400002 REACTION (5-B-11(P,G)6-C-12,PAR,POL/DA,,ANA) T020700400003 INC-SOURCE (POLIS) Beam polarization typically 0.70-0.75. T020700400004 SAMPLE Solid boron targets, enriched to 97.1% 11B. Target T020700400005 thicknesses ranged from 25-35 mg/cm2. T020700400006 METHOD (SFLIP) Beam polarization reversed every 60 sec. T020700400007 DETECTOR Beam polarimeter contained a 4He gas cell. T020700400008 ERR-ANALYS (DATA-ERR) Error scanned from figures. T020700400009 Data-point reader uncertainty on angle 0.5 degrees. T020700400010 STATUS (CURVE) Scanned from Fig. 3 and 4 in reference at T020700400011 CAJAD. T020700400012 ENDBIB 10 0 T020700400013 COMMON 1 3 T020700400014 E-LVL T020700400015 MEV T020700400016 0. T020700400017 ENDCOMMON 3 0 T020700400018 DATA 4 13 T020700400019 EN ANG DATA DATA-ERR T020700400020 MEV ADEG NO-DIM NO-DIM T020700400021 28.35 32.3 -0.05 0.02 T020700400022 28.35 45.4 -0.1 0.018 T020700400023 28.35 71.1 0.175 0.013 T020700400024 28.35 96.5 0.2 0.013 T020700400025 28.35 111.4 0.15 0.025 T020700400026 28.35 131.3 0.32 0.04 T020700400027 28.35 145.7 -0.11 0.11 T020700400028 49.2 32.6 -0.017 0.016 T020700400029 49.2 52.7 0.017 0.015 T020700400030 49.2 92.5 0.025 0.029 T020700400031 49.2 112.2 -0.019 0.015 T020700400032 49.2 132.6 0.22 0.07 T020700400033 49.2 152.3 0.19 0.07 T020700400034 ENDDATA 15 0 T020700400035 ENDSUBENT 34 0 T020700499999 SUBENT T0207005 20020805 0000T020700500001 BIB 4 14 T020700500002 REACTION (6-C-12(P,G)7-N-13,PAR,DA) T020700500003 SAMPLE Solid carbon targets, enriched to 99.9% 12C. Target T020700500004 thicknesses ranged from 25-35 mg/cm2. T020700500005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700500006 associated with T020700500007 . stripping the spectra (<15%), T020700500008 . resum correction, including uncertainty in detector T020700500009 efficiency (<15%), T020700500010 Uncertainties associated with target thickness and T020700500011 uniformity, charge collections, and solid angle are T020700500012 small by comparison. T020700500013 Data-point reader uncertainty on incident energy 0.3 T020700500014 MeV. T020700500015 STATUS (CURVE) Scanned from Fig. 5 in reference at CAJAD. T020700500016 ENDBIB 14 0 T020700500017 COMMON 3 3 T020700500018 ANG E-LVL DATA-ERR T020700500019 ADEG MEV PER-CENT T020700500020 60. 0. 20. T020700500021 ENDCOMMON 3 0 T020700500022 DATA 2 7 T020700500023 EN DATA T020700500024 MEV MU-B/SR T020700500025 27.79 1.17 T020700500026 29.32 0.83 T020700500027 32.00 0.76 T020700500028 37.22 0.73 T020700500029 60.82 0.30 T020700500030 81.27 0.132 T020700500031 90.84 0.187 T020700500032 ENDDATA 9 0 T020700500033 ENDSUBENT 32 0 T020700599999 SUBENT T0207006 20020805 0000T020700600001 BIB 4 13 T020700600002 REACTION (6-C-12(P,G)7-N-13,PAR,DA) T020700600003 SAMPLE Solid carbon targets, enriched to 99.9% 12C. Target T020700600004 thicknesses ranged from 25-35 mg/cm2. T020700600005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700600006 associated with T020700600007 . stripping the spectra (<15%), T020700600008 . resum correction, including uncertainty in detector T020700600009 efficiency (<15%), T020700600010 Uncertainties associated with target thickness and T020700600011 uniformity, charge collections, and solid angle are T020700600012 small by comparison. T020700600013 Data-point reader uncertainty 0.5 degrees. T020700600014 STATUS (CURVE) Scanned from Fig. 5 in reference at CAJAD. T020700600015 ENDBIB 13 0 T020700600016 COMMON 3 3 T020700600017 EN E-LVL DATA-ERR T020700600018 MEV MEV PER-CENT T020700600019 28.35 0. 20. T020700600020 ENDCOMMON 3 0 T020700600021 DATA 2 5 T020700600022 ANG DATA T020700600023 ADEG MU-B/SR T020700600024 30.7 0.49 T020700600025 72.1 0.76 T020700600026 110.3 0.24 T020700600027 130.4 0.09 T020700600028 145.5 0.016 T020700600029 ENDDATA 7 0 T020700600030 ENDSUBENT 29 0 T020700699999 SUBENT T0207007 20020805 0000T020700700001 BIB 6 8 T020700700002 REACTION (6-C-12(P,G)7-N-13,PAR,POL/DA,,ANA) T020700700003 SAMPLE Solid carbon targets, enriched to 99.9% 12C. Target T020700700004 thicknesses ranged from 25-35 mg/cm2. T020700700005 METHOD (SFLIP) Beam polarization reversed every 60 sec. T020700700006 DETECTOR Beam polarimeter contained a 4He gas cell. T020700700007 ERR-ANALYS (DATA-ERR) Error scanned from figures. T020700700008 Data-point reader uncertainty 0.5 degrees. T020700700009 STATUS (CURVE) Scanned from Fig. 5 in reference at CAJAD. T020700700010 ENDBIB 8 0 T020700700011 COMMON 2 3 T020700700012 EN E-LVL T020700700013 MEV MEV T020700700014 28.35 0. T020700700015 ENDCOMMON 3 0 T020700700016 DATA 3 5 T020700700017 ANG DATA DATA-ERR T020700700018 ADEG NO-DIM NO-DIM T020700700019 28.9 0.41 0.1 T020700700020 69.9 0.076 0.027 T020700700021 110.1 -0.142 0.029 T020700700022 130.2 -0.19 0.4 T020700700023 144.6 -0.23 0.7 T020700700024 ENDDATA 7 0 T020700700025 ENDSUBENT 24 0 T020700799999 SUBENT T0207008 20020805 0000T020700800001 BIB 4 14 T020700800002 REACTION (7-N-15(P,G)8-O-16,PAR,DA) T020700800003 SAMPLE Nitrogen gas targets, enriched to 99% 14N enclosed T020700800004 in thin-walled brass cell. T020700800005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700800006 associated with T020700800007 . stripping the spectra (<15%), T020700800008 . resum correction, including uncertainty in detector T020700800009 efficiency (<15%), T020700800010 Uncertainties associated with target thickness and T020700800011 uniformity, charge collections, and solid angle are T020700800012 small by comparison. T020700800013 Data-point reader uncertainty on incident energy 0.3 T020700800014 MeV. T020700800015 STATUS (CURVE) Scanned from Fig. 6 in reference at CAJAD. T020700800016 ENDBIB 14 0 T020700800017 COMMON 3 3 T020700800018 ANG E-LVL DATA-ERR T020700800019 ADEG MEV PER-CENT T020700800020 60. 0. 20. T020700800021 ENDCOMMON 3 0 T020700800022 DATA 2 13 T020700800023 EN DATA T020700800024 MEV MU-B/SR T020700800025 17.71 2.4 T020700800026 19.28 2.07 T020700800027 20.7 2.06 T020700800028 21.36 2.4 T020700800029 24.47 1.5 T020700800030 28.57 1.27 T020700800031 29.2 1.27 T020700800032 36.36 0.46 T020700800033 44.42 0.38 T020700800034 49.65 0.38 T020700800035 69.42 0.08 T020700800036 90.52 0.028 T020700800037 94.61 0.0217 T020700800038 ENDDATA 15 0 T020700800039 ENDSUBENT 38 0 T020700899999 SUBENT T0207009 20020805 0000T020700900001 BIB 4 13 T020700900002 REACTION (7-N-15(P,G)8-O-16,PAR,DA) T020700900003 SAMPLE Nitrogen gas targets, enriched to 99% 14N enclosed T020700900004 in thin-walled brass cell. T020700900005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020700900006 associated with T020700900007 . stripping the spectra (<15%), T020700900008 . resum correction, including uncertainty in detector T020700900009 efficiency (<15%), T020700900010 Uncertainties associated with target thickness and T020700900011 uniformity, charge collections, and solid angle are T020700900012 small by comparison. T020700900013 Data-point reader uncertainty on angle 0.5 degrees. T020700900014 STATUS (CURVE) Scanned from Fig. 6 in reference at CAJAD. T020700900015 ENDBIB 13 0 T020700900016 COMMON 3 3 T020700900017 EN E-LVL DATA-ERR T020700900018 MEV MEV PER-CENT T020700900019 49.69 0. 20. T020700900020 ENDCOMMON 3 0 T020700900021 DATA 2 6 T020700900022 ANG DATA T020700900023 ADEG MU-B/SR T020700900024 31.5 0.18 T020700900025 47.6 0.35 T020700900026 62. 0.324 T020700900027 77. 0.249 T020700900028 91.1 0.176 T020700900029 121.8 0.03 T020700900030 ENDDATA 8 0 T020700900031 ENDSUBENT 30 0 T020700999999 SUBENT T0207010 20020805 0000T020701000001 BIB 6 8 T020701000002 REACTION (7-N-15(P,G)8-O-16,PAR,POL/DA,,ANA) T020701000003 SAMPLE Nitrogen gas targets, enriched to 99% 14N enclosed T020701000004 in thin-walled brass cell. T020701000005 METHOD (SFLIP) Beam polarization reversed every 60 sec. T020701000006 DETECTOR Beam polarimeter contained a 4He gas cell. T020701000007 ERR-ANALYS (DATA-ERR) Error scanned from figures. T020701000008 Data-point reader uncertainty 0.5 degrees. T020701000009 STATUS (CURVE) Scanned from Fig. 6 in reference at CAJAD. T020701000010 ENDBIB 8 0 T020701000011 COMMON 2 3 T020701000012 EN E-LVL T020701000013 MEV MEV T020701000014 49.69 0. T020701000015 ENDCOMMON 3 0 T020701000016 DATA 3 4 T020701000017 ANG DATA DATA-ERR T020701000018 ADEG NO-DIM NO-DIM T020701000019 44.9 0.44 0.09 T020701000020 59.2 0.09 0.04 T020701000021 75.2 -0.11 0.08 T020701000022 90.6 -0.1 0.1 T020701000023 ENDDATA 6 0 T020701000024 ENDSUBENT 23 0 T020701099999 SUBENT T0207011 20020805 0000T020701100001 BIB 4 14 T020701100002 REACTION (8-O-16(P,G)9-F-17,PAR,DA) T020701100003 SAMPLE Natural oxygen gas targets, enclosed in thin-walled T020701100004 brass cell. T020701100005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020701100006 associated with T020701100007 . stripping the spectra (<15%), T020701100008 . resum correction, including uncertainty in detector T020701100009 efficiency (<15%), T020701100010 Uncertainties associated with target thickness and T020701100011 uniformity, charge collections, and solid angle are T020701100012 small by comparison. T020701100013 Data-point reader uncertainty on incident energy 0.3 T020701100014 MeV. T020701100015 STATUS (CURVE) Scanned from Fig. 7 in reference at CAJAD. T020701100016 ENDBIB 14 0 T020701100017 COMMON 3 3 T020701100018 ANG E-LVL DATA-ERR T020701100019 ADEG MEV PER-CENT T020701100020 60. 0. 20. T020701100021 ENDCOMMON 3 0 T020701100022 DATA 2 3 T020701100023 EN DATA T020701100024 MEV MU-B/SR T020701100025 20.89 8.7 T020701100026 28.24 5.1 T020701100027 44.51 2.2 T020701100028 ENDDATA 5 0 T020701100029 ENDSUBENT 28 0 T020701199999 SUBENT T0207012 20020805 0000T020701200001 BIB 4 14 T020701200002 REACTION (8-O-16(P,G)9-F-17,PAR,DA) T020701200003 SAMPLE Natural oxygen gas targets, enclosed in thin-walled T020701200004 brass cell. T020701200005 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020701200006 associated with T020701200007 . stripping the spectra (<15%), T020701200008 . resum correction, including uncertainty in detector T020701200009 efficiency (<15%), T020701200010 Uncertainties associated with target thickness and T020701200011 uniformity, charge collections, and solid angle are T020701200012 small by comparison. T020701200013 Data-point reader uncertainty on angle 0.5 degrees. T020701200014 MeV. T020701200015 STATUS (CURVE) Scanned from Fig. 7 in reference at CAJAD. T020701200016 ENDBIB 14 0 T020701200017 COMMON 3 3 T020701200018 EN E-LVL DATA-ERR T020701200019 MEV MEV PER-CENT T020701200020 20.8 0. 20. T020701200021 ENDCOMMON 3 0 T020701200022 DATA 2 2 T020701200023 ANG DATA T020701200024 ADEG MU-B/SR T020701200025 61.3 8.3 T020701200026 91. 6.6 T020701200027 ENDDATA 4 0 T020701200028 ENDSUBENT 27 0 T020701299999 SUBENT T0207013 20020805 0000T020701300001 BIB 6 8 T020701300002 REACTION (8-O-16(P,G)9-F-17,PAR,POL/DA,,ANA) T020701300003 SAMPLE Natural oxygen gas targets, enclosed in thin-walled T020701300004 brass cell. T020701300005 METHOD (SFLIP) Beam polarization reversed every 60 sec. T020701300006 DETECTOR Beam polarimeter contained a 4He gas cell. T020701300007 ERR-ANALYS (DATA-ERR) Error scanned from figures. T020701300008 Data-point reader uncertainty 0.5 degrees. T020701300009 STATUS (CURVE) Scanned from Fig. 7 in reference at CAJAD. T020701300010 ENDBIB 8 0 T020701300011 COMMON 2 3 T020701300012 EN E-LVL T020701300013 MEV MEV T020701300014 20.8 0. T020701300015 ENDCOMMON 3 0 T020701300016 DATA 3 2 T020701300017 ANG DATA DATA-ERR T020701300018 ADEG NO-DIM NO-DIM T020701300019 60.1 -0.16 0.025 T020701300020 91. -0.1 0.018 T020701300021 ENDDATA 4 0 T020701300022 ENDSUBENT 21 0 T020701399999 SUBENT T0207014 20020805 0000T020701400001 BIB 4 15 T020701400002 REACTION (13-AL-27(P,G)14-SI-28,PAR,DA) T020701400003 SAMPLE Self-supporting natural aluminum foils of 99.35% T020701400004 purity. Taget thicknesses 13.22-41 mg/cm2 for T020701400005 various runs. T020701400006 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020701400007 associated with T020701400008 . stripping the spectra (<15%), T020701400009 . resum correction, including uncertainty in detector T020701400010 efficiency (<15%), T020701400011 Uncertainties associated with target thickness and T020701400012 uniformity, charge collections, and solid angle are T020701400013 small by comparison. T020701400014 Data-point reader uncertainty on incident energy 0.3 T020701400015 MeV. T020701400016 STATUS (CURVE) Scanned from Fig. 8 in reference at CAJAD. T020701400017 ENDBIB 15 0 T020701400018 COMMON 3 3 T020701400019 ANG E-LVL DATA-ERR T020701400020 ADEG MEV PER-CENT T020701400021 60. 0. 20. T020701400022 ENDCOMMON 3 0 T020701400023 DATA 2 7 T020701400024 EN DATA T020701400025 MEV MU-B/SR T020701400026 20.97 0.7 T020701400027 22.71 0.9 T020701400028 26.86 0.62 T020701400029 30.80 0.61 T020701400030 40.52 0.42 T020701400031 42.86 0.165 T020701400032 81.7 0.028 T020701400033 ENDDATA 9 0 T020701400034 ENDSUBENT 33 0 T020701499999 SUBENT T0207015 20020805 0000T020701500001 BIB 4 14 T020701500002 REACTION (13-AL-27(P,G)14-SI-28,PAR,DA) T020701500003 SAMPLE Self-supporting natural aluminum foils of 99.35% T020701500004 purity. Taget thicknesses 13.22-41 mg/cm2 for T020701500005 various runs. T020701500006 ERR-ANALYS (DATA-ERR) Uncertainty primarily due to uncertainties T020701500007 associated with T020701500008 . stripping the spectra (<15%), T020701500009 . resum correction, including uncertainty in detector T020701500010 efficiency (<15%), T020701500011 Uncertainties associated with target thickness and T020701500012 uniformity, charge collections, and solid angle are T020701500013 small by comparison. T020701500014 Data-point reader uncertainty on angle 0.5 degrees. T020701500015 STATUS (CURVE) Scanned from Fig. 8 in reference at CAJAD. T020701500016 ENDBIB 14 0 T020701500017 COMMON 3 3 T020701500018 EN E-LVL DATA-ERR T020701500019 MEV MEV PER-CENT T020701500020 20.8 0. 20. T020701500021 ENDCOMMON 3 0 T020701500022 DATA 2 5 T020701500023 ANG DATA T020701500024 ADEG MU-B/SR T020701500025 30.2 0.70 T020701500026 43.2 0.80 T020701500027 59.7 0.75 T020701500028 89.4 0.68 T020701500029 119.7 0.375 T020701500030 ENDDATA 7 0 T020701500031 ENDSUBENT 30 0 T020701599999 SUBENT T0207016 20020805 0000T020701600001 BIB 6 9 T020701600002 REACTION (13-AL-27(P,G)14-SI-28,PAR,POL/DA,,ANA) T020701600003 SAMPLE Self-supporting natural aluminum foils of 99.35% T020701600004 purity. Taget thicknesses 13.22-41 mg/cm2 for T020701600005 various runs. T020701600006 METHOD (SFLIP) Beam polarization reversed every 60 sec. T020701600007 DETECTOR Beam polarimeter contained a 4He gas cell. T020701600008 ERR-ANALYS (DATA-ERR) Error scanned from figures. T020701600009 Data-point reader uncertainty 0.5 degrees. T020701600010 STATUS (CURVE) Scanned from Fig. 8 in reference at CAJAD. T020701600011 ENDBIB 9 0 T020701600012 COMMON 2 3 T020701600013 EN E-LVL T020701600014 MEV MEV T020701600015 20.8 0. T020701600016 ENDCOMMON 3 0 T020701600017 DATA 3 5 T020701600018 ANG DATA DATA-ERR T020701600019 ADEG NO-DIM NO-DIM T020701600020 29.8 -0.13 0.05 T020701600021 44.5 -0.17 0.03 T020701600022 59.8 0.2 0.04 T020701600023 91.2 0.32 0.04 T020701600024 122.2 0.51 0.04 T020701600025 ENDDATA 7 0 T020701600026 ENDSUBENT 25 0 T020701699999 ENDENTRY 16 0 T020799999999