ENTRY T0048 20220418 C217T004800000001 SUBENT T0048001 20220418 C217T004800100001 BIB 7 13 T004800100002 TITLE High-lying 0+ and 3- levels in 12C T004800100003 AUTHOR (S.S.Hanna,W.Feldman,M.Suffert,D.Kurath) T004800100004 REFERENCE (J,PR/C,25,1179,1982) T004800100005 #doi:10.1103/PhysRevC.25.1179 T004800100006 INSTITUTE (1USASTF,1USAANL) T004800100007 FACILITY (VDGT,1USASTF) T004800100008 ERR-ANALYS (DATA-ERR) No information on source of uncertainties. T004800100009 HISTORY (20000412C) VM T004800100010 (20220418A) BP: Added doi, corrected title spelling, T004800100011 updated SAMPLE, digitized data (unobtainable data) T004800100012 per an NRDC decision for data sets that were T004800100013 published before 2000 (C32 of WP2022-01) for T004800100014 subentris 4-5. T004800100015 ENDBIB 13 0 T004800100016 NOCOMMON 0 0 T004800100017 ENDSUBENT 16 0 T004800199999 SUBENT T0048002 20220418 C217T004800200001 BIB 3 7 T004800200002 REACTION (5-B-11(P,G)6-C-12,PAR,DA,,LEG/RSL) T004800200003 STATUS (DEP,T0048004) T004800200004 (DEP,T0048005) T004800200005 (TABLE) Table I, page 1182. Relative (counts) angular T004800200006 distributions given in Fig.4 of reference for 5.06- T004800200007 MeV gamma and in Fig. 6 for 8.72- and 18.36-MeV gammas.T004800200008 HISTORY (20220418A) BP: Updated STATUS. T004800200009 ENDBIB 7 0 T004800200010 COMMON 1 3 T004800200011 E-EXC T004800200012 MEV T004800200013 18.36 T004800200014 ENDCOMMON 3 0 T004800200015 DATA 4 8 T004800200016 EN NUMBER DATA DATA-ERR T004800200017 MEV NO-DIM NO-DIM NO-DIM T004800200018 2.45 1. -0.46 0.04 T004800200019 2.45 2. 0.08 0.03 T004800200020 2.63 2. 0.34 0.03 T004800200021 2.63 4. -0.08 0.03 T004800200022 2.64 2. 0.17 0.03 T004800200023 2.64 4. -0.03 0.03 T004800200024 2.96 1. 0.60 0.04 T004800200025 2.96 2. 0.28 0.03 T004800200026 ENDDATA 10 0 T004800200027 ENDSUBENT 26 0 T004800299999 SUBENT T0048003 20220418 C217T004800300001 BIB 8 16 T004800300002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) T004800300003 SAMPLE 150 microg/cm2. Isotopically enriched 11B films T004800300004 evaporated onto Ta or Au backings. T004800300005 DETECTOR (NAICR) The Stanford 24x24 cm NaI spectrometer. T004800300006 METHOD Angular distributions were obtained by measurements T004800300007 at 5-7 angles and at several energies over each T004800300008 resonance. A collimation angle of 10.5 was used for T004800300009 these measurements. Approximately 45 cm of paraffin T004800300010 was placed between target and detector to reduce the T004800300011 neutron background at the higher bombarding energies. T004800300012 MONITOR (5-B-11(P,G)6-C-12,PAR,DA) T004800300013 MONIT-REF ((MONIT)F0332002,R.E.Segel+,J,PR,139,B818,1965) T004800300014 STATUS (CURVE) Fig. 3, page 1181. T004800300015 (COREL,T0048004) Data with 300 ug/cm2 thick sample T004800300016 (COREL,T0048005) Data with 750 ug/cm2 thick sample T004800300017 HISTORY (20220418A) BP: Digitized data, added MONIT-REF. T004800300018 ENDBIB 16 0 T004800300019 COMMON 3 3 T004800300020 ANG E-EXC E-NRM T004800300021 ADEG MEV MEV T004800300022 90. 17.77 4.43 T004800300023 ENDCOMMON 3 0 T004800300024 DATA 3 10 T004800300025 EN DATA DATA-ERR T004800300026 MEV NB/SR NB/SR T004800300027 1.886 106.031 12.130 T004800300028 1.912 131.306 12.130 T004800300029 1.940 186.445 15.839 T004800300030 1.963 370.339 17.723 T004800300031 1.983 443.184 19.601 T004800300032 2.014 518.863 25.199 T004800300033 2.042 431.240 24.266 T004800300034 2.065 227.896 28.016 T004800300035 2.090 111.335 11.191 T004800300036 2.112 108.606 11.203 T004800300037 ENDDATA 12 0 T004800300038 ENDSUBENT 37 0 T004800399999 SUBENT T0048004 20220419 C217T004800400001 BIB 8 16 T004800400002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) T004800400003 SAMPLE 300 microg/cm2. Isotopically enriched 11B films T004800400004 evaporated onto Ta or Au backings. T004800400005 DETECTOR (NAICR) The Stanford 24x24 cm NaI spectrometer. T004800400006 METHOD Angular distributions were obtained by measurements T004800400007 at 5-7 angles and at several energies over each T004800400008 resonance. A collimation angle of 10.5 was used for T004800400009 these measurements. Approximately 45 cm of paraffin T004800400010 was placed between target and detector to reduce the T004800400011 neutron background at the higher bombarding energies. T004800400012 MONITOR (5-B-11(P,G)6-C-12,PAR,DA) T004800400013 MONIT-REF ((MONIT)F0332002,R.E.Segel+,J,PR,139,B818,1965) T004800400014 STATUS (CURVE) Fig. 3, page 1181. T004800400015 (COREL,T0048003) Data with 150 ug/cm2 thick sample T004800400016 (COREL,T0048005) Data with 750 ug/cm2 thick sample T004800400017 HISTORY (20220418C) BP T004800400018 ENDBIB 16 0 T004800400019 COMMON 2 3 T004800400020 ANG E-NRM T004800400021 ADEG MEV T004800400022 90. 4.43 T004800400023 ENDCOMMON 3 0 T004800400024 DATA 4 23 T004800400025 E-EXC EN DATA DATA-ERR T004800400026 MEV MEV NB/SR NB/SR T004800400027 17.77 2.119 99.298 9.348 T004800400028 17.77 2.219 60.422 13.081 T004800400029 17.77 2.273 34.463 9.331 T004800400030 17.77 2.323 44.884 8.398 T004800400031 17.77 2.373 53.439 11.197 T004800400032 17.77 2.423 44.264 11.191 T004800400033 18.36 1.813 24.620 10.264 T004800400034 18.36 1.913 57.592 10.276 T004800400035 18.36 2.011 39.238 12.130 T004800400036 18.36 2.116 38.635 9.337 T004800400037 18.36 2.223 51.102 10.270 T004800400038 18.36 2.273 60.590 14.008 T004800400039 18.36 2.323 75.676 13.063 T004800400040 18.36 2.374 86.103 9.354 T004800400041 18.36 2.424 127.315 11.203 T004800400042 18.36 2.476 164.801 13.996 T004800400043 18.36 2.522 209.735 12.130 T004800400044 18.36 2.573 247.221 11.180 T004800400045 18.36 2.632 269.801 11.214 T004800400046 18.36 2.679 238.221 13.985 T004800400047 18.36 2.732 232.791 11.197 T004800400048 18.36 2.779 198.411 13.052 T004800400049 18.36 2.829 175.241 8.409 T004800400050 ENDDATA 25 0 T004800400051 ENDSUBENT 50 0 T004800499999 SUBENT T0048005 20220419 C217T004800500001 BIB 8 16 T004800500002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) T004800500003 SAMPLE 750 microg/cm2. Isotopically enriched 11B films T004800500004 evaporated onto Ta or Au backings. T004800500005 DETECTOR (NAICR) The Stanford 24x24 cm NaI spectrometer. T004800500006 METHOD Angular distributions were obtained by measurements T004800500007 at 5-7 angles and at several energies over each T004800500008 resonance. A collimation angle of 10.5 was used for T004800500009 these measurements. Approximately 45 cm of paraffin T004800500010 was placed between target and detector to reduce the T004800500011 neutron background at the higher bombarding energies. T004800500012 MONITOR (5-B-11(P,G)6-C-12,PAR,DA) T004800500013 MONIT-REF ((MONIT)F0332002,R.E.Segel+,J,PR,139,B818,1965) T004800500014 STATUS (CURVE) Fig. 3, page 1181. T004800500015 (COREL,T0048003) Data with 150 ug/cm2 thick sample T004800500016 (COREL,T0048004) Data with 300 ug/cm2 thick sample T004800500017 HISTORY (20220418C) BP T004800500018 ENDBIB 16 0 T004800500019 COMMON 3 3 T004800500020 ANG E-EXC E-NRM T004800500021 ADEG MEV MEV T004800500022 90. 18.36 4.43 T004800500023 ENDCOMMON 3 0 T004800500024 DATA 3 8 T004800500025 EN DATA DATA-ERR T004800500026 MEV NB/SR NB/SR T004800500027 2.500 195.669 14.929 T004800500028 2.612 267.871 12.124 T004800500029 2.656 268.943 16.784 T004800500030 2.710 255.115 13.069 T004800500031 2.799 200.342 13.046 T004800500032 2.860 191.202 14.941 T004800500033 2.914 152.181 11.203 T004800500034 3.016 121.708 13.063 T004800500035 ENDDATA 10 0 T004800500036 ENDSUBENT 35 0 T004800599999 ENDENTRY 5 0 T004899999999