ENTRY S0277 20220518 S031S027700000001 SUBENT S0277001 20220518 S031S027700100001 BIB 12 34 S027700100002 TITLE Single-neutron removal from 14,15,16C near 240 S027700100003 MeV/nucleon S027700100004 AUTHOR (Y.Z.Sun,S.T.Wang,Z.Y.Sun,X.H.Zhang,S.Y.Jin,Y.X.Zhao, S027700100005 D.Y.Pang,S.W.Tang,D.Yan,P.Ma,Y.H.Yu,K.Yue,F.Fang, S027700100006 Y.J.Zhang,C.G.Lu,L.M.Duan) S027700100007 INSTITUTE (3CPRCPR) Anyang Normal University, Anyang S027700100008 (3CPRIMP,3CPRUCA,3CPRLNZ,3CPRBHN) S027700100009 REFERENCE (J,PR/C,104,014310,2021) S027700100010 #doi:10.1103/PhysRevC.104.014310 S027700100011 FACILITY (CYCLO,3CPRIMP) The External Target Facility (ETF) of S027700100012 the Heavy Ion Research Facility in Lanzhou-Cooler S027700100013 Storage Ring(HIRFL-CSR) S027700100014 INC-SOURCE Primary 18O beams were accelerated to 280 MeV/nucleon S027700100015 by HIRFL-CSR and fragmented on a 15-mm-thick Be target.S027700100016 SAMPLE 900 mg/cm2 carbon target S027700100017 METHOD (EDE,TOF) The generated secondary beams were S027700100018 subsequently selected by their magnetic rigidities in S027700100019 the second Radioactive Ion Beam Line in Lanzhou S027700100020 (RIBLL2) and then delivered to ETF to impinge on a S027700100021 900 mg/cm2 carbon target, where their energies S027700100022 dropped to around 240 MeV/nucleon upon hitting the S027700100023 target. S027700100024 DETECTOR (IOCH,SCIN) The particle Z number was recorded by the S027700100025 multisampling ionization chamber (MUSIC) downstream S027700100026 from the reaction target, while the particle TOF were S027700100027 given by the plastic scintillators and the TOF Wall. S027700100028 (TRD) The heavy reaction products were traced via a S027700100029 series of drift chambers, lined up along the S027700100030 particles' flying directions, with the latter S027700100031 constituting the multi-wire drift chamber (MWDC) Array.S027700100032 ERR-ANALYS (ERR-S) All the errors are statistical. S027700100033 STATUS (TABLE) Data were obtained from TABLE 1 of Phys. Rev. S027700100034 C 104, 014310, 2021. S027700100035 HISTORY (20220518C) Compiled by Xi Tao (CNDC) S027700100036 ENDBIB 34 0 S027700100037 NOCOMMON 0 0 S027700100038 ENDSUBENT 37 0 S027700199999 SUBENT S0277002 20220518 S031S027700200001 BIB 2 4 S027700200002 REACTION (6-C-0(6-C-16,X)6-C-15,,SIG) S027700200003 ANALYSIS The detecting efficiencies and the compensation S027700200004 factors for the target-thickness effect in target-in S027700200005 and target-out are 0.908+-5., 0.946+-5. and 0.983+-6.. S027700200006 ENDBIB 4 0 S027700200007 NOCOMMON 0 0 S027700200008 DATA 3 1 S027700200009 EN DATA ERR-S S027700200010 MEV/A MB MB S027700200011 239. 83. 8. S027700200012 ENDDATA 3 0 S027700200013 ENDSUBENT 12 0 S027700299999 SUBENT S0277003 20220518 S031S027700300001 BIB 2 4 S027700300002 REACTION (6-C-0(6-C-15,X)6-C-14,,SIG) S027700300003 ANALYSIS The detecting efficiencies and the compensation S027700300004 factors for the target-thickness effect in target-in S027700300005 and target-out are 0.908+-4., 0.944+-5. and 0.983+-5.. S027700300006 ENDBIB 4 0 S027700300007 NOCOMMON 0 0 S027700300008 DATA 3 1 S027700300009 EN DATA ERR-S S027700300010 MEV/A MB MB S027700300011 237. 108. 11. S027700300012 ENDDATA 3 0 S027700300013 ENDSUBENT 12 0 S027700399999 SUBENT S0277004 20220518 S031S027700400001 BIB 2 4 S027700400002 REACTION (6-C-0(6-C-14,X)6-C-13,,SIG) S027700400003 ANALYSIS The detecting efficiencies and the compensation S027700400004 factors for the target-thickness effect in target-in S027700400005 and target-out are 0.913+-3., 0.959+-3. and 0.988+-4.. S027700400006 ENDBIB 4 0 S027700400007 NOCOMMON 0 0 S027700400008 DATA 3 1 S027700400009 EN DATA ERR-S S027700400010 MEV/A MB MB S027700400011 235. 80. 7. S027700400012 ENDDATA 3 0 S027700400013 ENDSUBENT 12 0 S027700499999 ENDENTRY 4 0 S027799999999