ENTRY S0067 20120911 S016S006700000001 SUBENT S0067001 20120911 S016S006700100001 BIB 13 39 S006700100002 TITLE Measurement of the total reaction cross section for S006700100003 the mirror nuclei 12N and 12B S006700100004 AUTHOR (Li Jia-Xing,Liu Ping-Ping,Wang Jian-Song, S006700100005 Hu Zheng-Guo,Mao Rui-Shi,Sun Zhi-Yu,Li Chen, S006700100006 Chen Ruo-Fu,Xu Hu-Shan,Xiao Guo-Qing,Guo Zhong-Yan) S006700100007 INSTITUTE (3CPRCPR) School of Physical Science and Technology, S006700100008 Southwest University (Chongqing, China) S006700100009 (3CPRIMP) S006700100010 REFERENCE (J,CPH/C,34,(4),452,2010) S006700100011 REL-REF (N,S0064002,Li Jia-Xing+,J,CPL,27,(3),032501,2010) S006700100012 Another measurement of 14-SI-0(7-N-12,NON). S006700100013 FACILITY (PRJFS,3CPRIMP) S006700100014 The 14N(7+) primary beam was accelerated by the Heavy S006700100015 Ion Research Facility of Lanzhou(HIRFL). S006700100016 SAMPLE A silicon detector (1000 um in thickness), which S006700100017 serves as a reaction sample and a dE detector. S006700100018 DETECTOR (PPAC) Two PPACs (100 x 100 mm2 effective area); S006700100019 (SCIN) One plastic scintillator with 50 um in S006700100020 thickness; S006700100021 (SI,CSICR,SIBAR) The telescope detector consists S006700100022 of 2 silicon semiconductor detectors and one CsI(Tl) S006700100023 stopping detector with 325 um and 10 mm in thickness, S006700100024 45x45 mm and 70x70 mm in effective area, S006700100025 respectively. S006700100026 METHOD (TOF,EDE,TRN) S006700100027 The same particle upstream and downstream of the S006700100028 reaction target can be counted, and the reaction cross S006700100029 section is obtained by the transmission method. S006700100030 INC-SOURCE The typical 14N primary beam intensity was about 20 nA S006700100031 on the production target of Be with 3123 um in S006700100032 thickness which was installed at the entrance of S006700100033 RIBLL. 12N and 12B were produced by the projectile S006700100034 fragmentation process. S006700100035 ERR-ANALYS (DATA-ERR) The errors include systematic errors, S006700100036 statistical errors and errors from the way to select S006700100037 the outgoing particles. S006700100038 STATUS (TABLE)Data were taken from Table 1 at page 454 of S006700100039 J,CPC,34,(4),452,2010. S006700100040 HISTORY (20120911C) Compiled by Guochang CHEN (CNDC) S006700100041 ENDBIB 39 0 S006700100042 NOCOMMON 0 0 S006700100043 ENDSUBENT 42 0 S006700199999 SUBENT S0067002 20120911 S016S006700200001 BIB 1 1 S006700200002 REACTION (14-SI-0(7-N-12,NON),,SIG) S006700200003 ENDBIB 1 0 S006700200004 NOCOMMON 0 0 S006700200005 DATA 3 1 S006700200006 EN DATA DATA-ERR S006700200007 MEV/A MB MB S006700200008 34.9 1760. 30. S006700200009 ENDDATA 3 0 S006700200010 ENDSUBENT 9 0 S006700299999 SUBENT S0067003 20120911 S016S006700300001 BIB 1 1 S006700300002 REACTION (14-SI-0(5-B-12,NON),,SIG) S006700300003 ENDBIB 1 0 S006700300004 NOCOMMON 0 0 S006700300005 DATA 3 1 S006700300006 EN DATA DATA-ERR S006700300007 MEV/A MB MB S006700300008 54.4 1490. 40. S006700300009 ENDDATA 3 0 S006700300010 ENDSUBENT 9 0 S006700399999 ENDENTRY 3 0 S006799999999