ENTRY S0013 20220927 S032S001300000001 SUBENT S0013001 20220927 S032S001300100001 BIB 13 32 S001300100002 TITLE Excitation functins for the 55Mn(a,n)58m,gCo, S001300100003 55Mn(a,2n)57Co and 55Mn(a,a+n)54Mn reactions S001300100004 AUTHOR (Long Xianguan,He Fuqing,Peng Xiufeng,Liu Mantian) S001300100005 INSTITUTE (3CPRSIU) S001300100006 EXP-YEAR (1988) S001300100007 REFERENCE (J,PHE,14,444,1990) S001300100008 (R,NST-003,198903) Preliminary results S001300100009 SAMPLE Stacked foils consisted of ten target foils, each S001300100010 prepared by vacuum evaporating Mn metal with S001300100011 thickness about 1 mg/cm2 onto 5.2 mg/cm2 thick Al S001300100012 foil and covered with 1.2 mg/cm2 thick Al catcher foil S001300100013 FACILITY (CYCLO,3CPRSIU) 1.2 M cyclotron S001300100014 METHOD (ACTIV,STTA) 2.5 h irradiation S001300100015 INC-SOURCE 26.8 MeV alpha particle, the beam current on the S001300100016 target was 0.2 - 0.3 uA. S001300100017 DETECTOR (HPGE) ORTEC GEM-30195 high-purity germanium detector S001300100018 with a energy resolution (FWHM) of 1.9 keV at 1332 S001300100019 keV gamma-ray of 60Co. The efficiency calibration was S001300100020 performed with 152Eu, 54Mn and 57Co standard sources, S001300100021 the uncertainty was 3% above 100 keV. S001300100022 ERR-ANALYS (DATA-ERR) The following uncertainties have been taken S001300100023 into account: S001300100024 -the sample thickness S001300100025 -the detector efficiency S001300100026 -statistics of peak counts S001300100027 STATUS (TABLE) Table 2 of High En.Nucl.Phy.Ch.,14,(5),444,1990S001300100028 HISTORY (19890814) compiled by chinese nuclear data center. S001300100029 corrections by VOF S001300100030 (20080228A) NDS(SD):BIB section updated: upper to lowerS001300100031 cases, 4-digits year, deleted EXP - from reaction code.S001300100032 (20220927A) Jimin Wang: main reference added, S001300100033 major revisions in 001 S001300100034 ENDBIB 32 0 S001300100035 NOCOMMON 0 0 S001300100036 ENDSUBENT 35 0 S001300199999 SUBENT S0013002 20080311 Y006S001300200001 BIB 2 3 S001300200002 REACTION (25-MN-55(A,N)27-CO-58-M,,SIG) S001300200003 DECAY-DATA (27-CO-58-M,9.15HR,DG,24.9,0.00032) S001300200004 (27-CO-58-G,70.92D,DG,810.8,0.994) S001300200005 ENDBIB 3 0 S001300200006 NOCOMMON 0 0 S001300200007 DATA 3 10 S001300200008 EN DATA DATA-ERR S001300200009 MEV MB MB S001300200010 26.5 50. 4. S001300200011 25.0 61. 5. S001300200012 23.5 95. 8. S001300200013 22.1 121. 10. S001300200014 20.5 183. 15. S001300200015 18.7 295. 24. S001300200016 17.0 351. 29. S001300200017 14.9 470. 38. S001300200018 12.8 477. 38. S001300200019 10.4 262. 21. S001300200020 ENDDATA 12 0 S001300200021 ENDSUBENT 20 0 S001300299999 SUBENT S0013003 20080311 Y006S001300300001 BIB 2 3 S001300300002 REACTION (25-MN-55(A,N)27-CO-58-G,,SIG) S001300300003 DECAY-DATA (27-CO-58-G,70.92D,DG,810.8,0.994) S001300300004 (27-CO-58-M,9.15HR,DG,24.9,0.00032) S001300300005 ENDBIB 3 0 S001300300006 NOCOMMON 0 0 S001300300007 DATA 3 10 S001300300008 EN DATA DATA-ERR S001300300009 MEV MB MB S001300300010 26.5 14. 1. S001300300011 25.0 18. 1. S001300300012 23.5 29. 2. S001300300013 22.1 29. 2. S001300300014 20.5 46. 4. S001300300015 18.7 76. 6. S001300300016 17.0 104. 8. S001300300017 14.9 185. 15. S001300300018 12.8 305. 24. S001300300019 10.4 216. 17. S001300300020 ENDDATA 12 0 S001300300021 ENDSUBENT 20 0 S001300399999 SUBENT S0013004 20080311 Y006S001300400001 BIB 2 2 S001300400002 REACTION (25-MN-55(A,2N)27-CO-57,,SIG) S001300400003 DECAY-DATA (27-CO-57,271.85D,DG,122.1,0.856) S001300400004 ENDBIB 2 0 S001300400005 NOCOMMON 0 0 S001300400006 DATA 3 8 S001300400007 EN DATA DATA-ERR S001300400008 MEV MB MB S001300400009 26.5 626. 50. S001300400010 25.0 633. 51. S001300400011 23.5 700. 56. S001300400012 22.1 661. 53. S001300400013 20.5 553. 44. S001300400014 18.7 536. 43. S001300400015 17.0 343. 27. S001300400016 14.9 173. 14. S001300400017 ENDDATA 10 0 S001300400018 ENDSUBENT 17 0 S001300499999 SUBENT S0013005 20080311 Y006S001300500001 BIB 2 2 S001300500002 REACTION (25-MN-55(A,N+A)25-MN-54,,SIG) S001300500003 DECAY-DATA (25-MN-54,312.5D,DG,834.8,1.000) S001300500004 ENDBIB 2 0 S001300500005 NOCOMMON 0 0 S001300500006 DATA 3 5 S001300500007 EN DATA DATA-ERR S001300500008 MEV MB MB S001300500009 26.5 147. 12. S001300500010 25.0 121. 10. S001300500011 23.5 110. 9. S001300500012 22.1 66. 6. S001300500013 20.5 40. 4. S001300500014 ENDDATA 7 0 S001300500015 ENDSUBENT 14 0 S001300599999 ENDENTRY 5 0 S001399999999