ENTRY P0019 20160709 C159P001900000001 SUBENT P0019001 20160709 C159P001900100001 BIB 10 21 P001900100002 INSTITUTE (2JPNOSA,2JPNKTO,2JPNNAG,2JPNJAE) P001900100003 REFERENCE (J,NP,80,335,1966) P001900100004 AUTHOR (K.Otozai,S.Kume,A.Mito,H.Okamura,R.Tsujino,Y.Kanchiku,P001900100005 T.Katoh,H.Gotoh) P001900100006 TITLE Excitation functions for the reactions induced by P001900100007 protons on Cd up to 37 MeV P001900100008 FACILITY (CYCLO,2JPNTOK) P001900100009 METHOD (STTA,ACTIV) Cadmium foils stacked with aluminum foils P001900100010 used to degrade energy. P001900100011 CORRECTION Corrected for energy spread of incident beam, target P001900100012 thickness, and straggling of incident particles in P001900100013 stack. P001900100014 ERR-ANALYS (DATA-ERR) Standard deviations, estimated from errors P001900100015 in radiation measurements, decay curve analysis, P001900100016 adopted half-lives and branching ratios. P001900100017 STATUS (TABLE) Data taken from Table 3 in reference. P001900100018 HISTORY (19830620T) Converted to EXFOR format by IAEA-NDS P001900100019 (19850215U) OS. Country code corrected. P001900100020 (20000808A) Converted to new date formats; BIB update. P001900100021 (20160705A) OS. Isomer assignments corrected in P001900100022 subs. 2,3,7,8,12,13. One author added. P001900100023 ENDBIB 21 0 P001900100024 NOCOMMON 0 0 P001900100025 ENDSUBENT 24 0 P001900199999 SUBENT P0019002 20160709 C159P001900200001 BIB 4 11 P001900200002 REACTION (48-CD-110(P,N)49-IN-110-M,,SIG) P001900200003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900200004 Natural cadmium foils used as well as isotopically P001900200005 enriched foils. Composition of isotopically enriched P001900200006 foils: P001900200007 106Cd (0.1%), 108Cd (0.2%), 110Cd (70.0%), P001900200008 111Cd (18.6%), 112Cd (7.0%), 113Cd (1.3%), P001900200009 114Cd (2.3%), 115Cd (0.5%). P001900200010 DECAY-DATA (49-IN-110-M,66.MIN) P001900200011 HISTORY (19850829A) Corrected by NNDC P001900200012 (20160705A) Isomer assignment corrected P001900200013 ENDBIB 11 0 P001900200014 NOCOMMON 0 0 P001900200015 DATA 3 5 P001900200016 EN-CM DATA DATA-ERR P001900200017 MEV MB MB P001900200018 7.3 300. 10. P001900200019 9.1 500. 30. P001900200020 11.2 650. 30. P001900200021 13.1 760. 50. P001900200022 14.7 420. 30. P001900200023 ENDDATA 7 0 P001900200024 ENDSUBENT 23 0 P001900299999 SUBENT P0019003 20160709 C159P001900300001 BIB 4 11 P001900300002 REACTION (48-CD-110(P,N)49-IN-110-G,,SIG) P001900300003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900300004 Natural cadmium foils used as well as isotopically P001900300005 enriched foils. Composition of isotopically enriched P001900300006 foils: P001900300007 106Cd (0.1%), 108Cd (0.2%), 110Cd (70.0%), P001900300008 111Cd (18.6%), 112Cd (7.0%), 113Cd (1.3%), P001900300009 114Cd (2.3%), 115Cd (0.5%). P001900300010 DECAY-DATA (49-IN-110-G,4.9HR) P001900300011 HISTORY (19850829A) Corrected by NNDC P001900300012 (20160705A) Isomer assignment corrected P001900300013 ENDBIB 11 0 P001900300014 NOCOMMON 0 0 P001900300015 DATA 3 5 P001900300016 EN-CM DATA DATA-ERR P001900300017 MEV MB MB P001900300018 7.3 17. 2. P001900300019 9.1 41. 5. P001900300020 11.2 120. 10. P001900300021 13.1 130. 10. P001900300022 14.7 170. 20. P001900300023 ENDDATA 7 0 P001900300024 ENDSUBENT 23 0 P001900399999 SUBENT P0019004 20000808 0000P001900400001 BIB 4 11 P001900400002 REACTION (48-CD-110(P,2N)49-IN-109,,SIG) P001900400003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900400004 Natural cadmium foils used as well as isotopically P001900400005 enriched foils. Composition of isotopically enriched P001900400006 foils: P001900400007 106Cd (0.1%), 108Cd (0.2%), 110Cd (70.0%), P001900400008 111Cd (18.6%), 112Cd (7.0%), 113Cd (1.3%), P001900400009 114Cd (2.3%), 115Cd (0.5%). P001900400010 DECAY-DATA (49-IN-109-G,4.3HR) P001900400011 HISTORY (19850829A) CORRECTED BY NNDC P001900400012 (20000808A) Reaction corrected. P001900400013 ENDBIB 11 0 P001900400014 NOCOMMON 0 0 P001900400015 DATA 3 3 P001900400016 EN DATA DATA-ERR P001900400017 MEV MB MB P001900400018 12.6 6. 1. P001900400019 13.5 77. 6. P001900400020 14.7 320. 30. P001900400021 ENDDATA 5 0 P001900400022 ENDSUBENT 21 0 P001900499999 SUBENT P0019005 20000808 0000P001900500001 BIB 4 10 P001900500002 REACTION (48-CD-110(P,N+P)48-CD-109,,SIG) P001900500003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900500004 Natural cadmium foils used as well as isotopically P001900500005 enriched foils. Composition of isotopically enriched P001900500006 foils: P001900500007 106Cd (0.1%), 108Cd (0.2%), 110Cd (70.0%), P001900500008 111Cd (18.6%), 112Cd (7.0%), 113Cd (1.3%), P001900500009 114Cd (2.3%), 115Cd (0.5%). P001900500010 DECAY-DATA (48-CD-109,470.D) P001900500011 HISTORY (19850829A) CORRECTED BY NNDC P001900500012 ENDBIB 10 0 P001900500013 NOCOMMON 0 0 P001900500014 DATA 3 3 P001900500015 EN DATA DATA-ERR P001900500016 MEV MB MB P001900500017 12.6 1. 2. P001900500018 13.5 5. 5. P001900500019 14.7 30. 20. P001900500020 ENDDATA 5 0 P001900500021 ENDSUBENT 20 0 P001900599999 SUBENT P0019006 20000808 0000P001900600001 BIB 4 11 P001900600002 REACTION (48-CD-111(P,N)49-IN-111,,SIG) P001900600003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900600004 Natural cadmium foils used as well as isotopically P001900600005 enriched foils. Composition of isotopically enriched P001900600006 foils: P001900600007 106Cd (0.01%), 108Cd (0.01%), 110Cd (0.59%), P001900600008 111Cd (92.0%), 112Cd (1.85%), 113Cd (0.43%), P001900600009 114Cd (4.97%), 115Cd (0.12%). P001900600010 DECAY-DATA (49-IN-111-G,2.81D) P001900600011 HISTORY (19850829A) Corrected by NNDC P001900600012 (20000808A) Reaction corrected. P001900600013 ENDBIB 11 0 P001900600014 NOCOMMON 0 0 P001900600015 DATA 3 4 P001900600016 EN DATA DATA-ERR P001900600017 MEV MB MB P001900600018 4.3 49. 3. P001900600019 6.7 210. 10. P001900600020 13.1 530. 70. P001900600021 14.7 390. 90. P001900600022 ENDDATA 6 0 P001900600023 ENDSUBENT 22 0 P001900699999 SUBENT P0019007 20160709 C159P001900700001 BIB 4 11 P001900700002 REACTION (48-CD-111(P,2N)49-IN-110-M,,SIG) P001900700003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900700004 Natural cadmium foils used as well as isotopically P001900700005 enriched foils. Composition of isotopically enriched P001900700006 foils: P001900700007 106Cd (0.01%), 108Cd (0.01%), 110Cd (0.59%), P001900700008 111Cd (92.0%), 112Cd (1.85%), 113Cd (0.43%), P001900700009 114Cd (4.97%), 115Cd (0.12%). P001900700010 DECAY-DATA (49-IN-110-M,66.MIN) P001900700011 HISTORY (19850829A) Corrected by NNDC P001900700012 (20160705A) Isomer assignment corrected P001900700013 ENDBIB 11 0 P001900700014 NOCOMMON 0 0 P001900700015 DATA 3 2 P001900700016 EN DATA DATA-ERR P001900700017 MEV MB MB P001900700018 13.1 270. 20. P001900700019 14.7 590. 30. P001900700020 ENDDATA 4 0 P001900700021 ENDSUBENT 20 0 P001900799999 SUBENT P0019008 20160709 C159P001900800001 BIB 4 11 P001900800002 REACTION (48-CD-111(P,2N)49-IN-110-G,,SIG) P001900800003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900800004 Natural cadmium foils used as well as isotopically P001900800005 enriched foils. Composition of isotopically enriched P001900800006 foils: P001900800007 106Cd (0.01%), 108Cd (0.01%), 110Cd (0.59%), P001900800008 111Cd (92.0%), 112Cd (1.85%), 113Cd (0.43%), P001900800009 114Cd (4.97%), 115Cd (0.12%). P001900800010 DECAY-DATA (49-IN-110-G,4.9HR) P001900800011 HISTORY (19850829A) Corrected by NNDC P001900800012 (20160705A) Isomer assignment corrected P001900800013 ENDBIB 11 0 P001900800014 NOCOMMON 0 0 P001900800015 DATA 3 3 P001900800016 EN DATA DATA-ERR P001900800017 MEV MB MB P001900800018 11.2 0.7 0.7 P001900800019 13.1 32. 5. P001900800020 14.7 110. 20. P001900800021 ENDDATA 5 0 P001900800022 ENDSUBENT 21 0 P001900899999 SUBENT P0019009 20000808 0000P001900900001 BIB 4 15 P001900900002 REACTION (48-CD-112(P,N)49-IN-112-G,,SIG) P001900900003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001900900004 In frequency fixed mode natural cadmium foils and P001900900005 foils isotopically enriched were used. Composition P001900900006 of enriched foils: P001900900007 106Cd (0.1%), 108Cd (0.1%), 110Cd (0.7%), P001900900008 111Cd (1.7%), 112Cd (83.5%), 113Cd (9.2%), P001900900009 114Cd (4.4%), 115Cd (0.3%). P001900900010 Isotopic composition of foils for runs with cyclotron P001900900011 operated in frequency modulated mode: P001900900012 106Cd (0.02%), 108Cd (0.02%), 110Cd (0.07%), P001900900013 111Cd (0.24%), 112Cd (98.87%), 113Cd (0.41%), P001900900014 114Cd (0.02%), 115Cd (0.02%). P001900900015 DECAY-DATA (49-IN-112-G,14.4MIN) P001900900016 HISTORY (19850829A) CORRECTED BY NNDC P001900900017 ENDBIB 15 0 P001900900018 NOCOMMON 0 0 P001900900019 DATA 3 5 P001900900020 EN DATA DATA-ERR P001900900021 MEV MB MB P001900900022 9.4 400. 60. P001900900023 13.1 300. 200. P001900900024 14.7 220. 40. P001900900025 17.3 60. 20. P001900900026 22.8 40. 10. P001900900027 ENDDATA 7 0 P001900900028 ENDSUBENT 27 0 P001900999999 SUBENT P0019010 20000808 0000P001901000001 BIB 4 8 P001901000002 REACTION (48-CD-112(P,N)49-IN-112-M,,SIG) P001901000003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001901000004 Isotopic composition of foils: P001901000005 106Cd (0.1%), 108Cd (0.1%), 110Cd (0.7%), P001901000006 111Cd (1.7%), 112Cd (83.5%), 113Cd (9.2%), P001901000007 114Cd (4.4%), 115Cd (0.3%). P001901000008 DECAY-DATA (49-IN-112-M,20.8MIN) P001901000009 HISTORY (19850829A) CORRECTED BY NNDC P001901000010 ENDBIB 8 0 P001901000011 NOCOMMON 0 0 P001901000012 DATA 3 5 P001901000013 EN DATA DATA-ERR P001901000014 MEV MB MB P001901000015 9.4 300. 40. P001901000016 13.1 280. 50. P001901000017 14.7 180. 40. P001901000018 17.3 110. 10. P001901000019 22.8 41. 6. P001901000020 ENDDATA 7 0 P001901000021 ENDSUBENT 20 0 P001901099999 SUBENT P0019011 20000808 0000P001901100001 BIB 4 9 P001901100002 REACTION (48-CD-112(P,2N)49-IN-111,,SIG) P001901100003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001901100004 Isotopic composition of foils: P001901100005 106Cd (0.1%), 108Cd (0.1%), 110Cd (0.7%), P001901100006 111Cd (1.7%), 112Cd (83.5%), 113Cd (9.2%), P001901100007 114Cd (4.4%), 115Cd (0.3%). P001901100008 DECAY-DATA (49-IN-111-G,2.81D) P001901100009 HISTORY (19850829A) CORRECTED BY NNDC P001901100010 (20000808A) Reaction corrected. P001901100011 ENDBIB 9 0 P001901100012 NOCOMMON 0 0 P001901100013 DATA 3 12 P001901100014 EN DATA DATA-ERR P001901100015 MEV MB MB P001901100016 9.4 5.3 0.8 P001901100017 13.1 340. 20. P001901100018 14.5 490. 20. P001901100019 14.7 560. 30. P001901100020 17.3 840. 20. P001901100021 20.8 870. 40. P001901100022 22.8 1000. 30. P001901100023 25.8 620. 30. P001901100024 28.6 340. 10. P001901100025 31.5 166. 7. P001901100026 34.5 123. 4. P001901100027 37.4 93. 4. P001901100028 ENDDATA 14 0 P001901100029 ENDSUBENT 28 0 P001901199999 SUBENT P0019012 20160709 C159P001901200001 BIB 4 9 P001901200002 REACTION (48-CD-112(P,3N)49-IN-110-M,,SIG) P001901200003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001901200004 Isotopic composition of foils: P001901200005 106Cd (0.1%), 108Cd (0.1%), 110Cd (0.7%), P001901200006 111Cd (1.7%), 112Cd (83.5%), 113Cd (9.2%), P001901200007 114Cd (4.4%), 115Cd (0.3%). P001901200008 DECAY-DATA (49-IN-110-M,66.MIN) P001901200009 HISTORY (19850829A) Corrected by NNDC P001901200010 (20160705A) Isomer assignment corrected P001901200011 ENDBIB 9 0 P001901200012 NOCOMMON 0 0 P001901200013 DATA 3 3 P001901200014 EN DATA DATA-ERR P001901200015 MEV MB MB P001901200016 22.8 29. 2. P001901200017 28.6 390. 30. P001901200018 34.5 320. 20. P001901200019 ENDDATA 5 0 P001901200020 ENDSUBENT 19 0 P001901299999 SUBENT P0019013 20160709 C159P001901300001 BIB 4 9 P001901300002 REACTION (48-CD-112(P,3N)49-IN-110-G,,SIG) P001901300003 SAMPLE Cadmium metal foils; areal density 3-5 mg/cm2. P001901300004 Isotopic composition of foils: P001901300005 106Cd (0.1%), 108Cd (0.1%), 110Cd (0.7%), P001901300006 111Cd (1.7%), 112Cd (83.5%), 113Cd (9.2%), P001901300007 114Cd (4.4%), 115Cd (0.3%). P001901300008 DECAY-DATA (49-IN-110-G,4.9HR) P001901300009 HISTORY (19850829A) Corrected by NNDC P001901300010 (20160705A) Isomer assignment corrected P001901300011 ENDBIB 9 0 P001901300012 NOCOMMON 0 0 P001901300013 DATA 3 3 P001901300014 EN DATA DATA-ERR P001901300015 MEV MB MB P001901300016 22.8 19. 3. P001901300017 28.6 310. 40. P001901300018 34.5 380. 50. P001901300019 ENDDATA 5 0 P001901300020 ENDSUBENT 19 0 P001901399999 ENDENTRY 13 0 P001999999999