ENTRY O2531 20210719 O084O253100000001 SUBENT O2531001 20210719 O084O253100100001 BIB 9 20 O253100100002 TITLE Global study of be 9Be + p at 2.72A MeV O253100100003 AUTHOR (V.Soukeras, O.Sgouros, A.Pakou, F.Cappuzzello, O253100100004 J.Casal, C.Agodi, G.A.Brischetto, S.Calabrese, O253100100005 D.Carbone, M.Cavallaro, I.Ciraldo, I.Dimitropoulos, O253100100006 S.Koulouris, L.La Fauci, I.Martel, O253100100007 M.Rodriguez-Gallardo, A.M.Sanchez-Benitez, O253100100008 G.Souliotis, A.Spatafora, D.Torresi) O253100100009 INSTITUTE (2ITYLNS,2GRCIOA,2ITYCAT,2ITYUPV,2SPNHLV,2SPNSEU) O253100100010 (2GRCGRC) National and Kapodistrian University of O253100100011 Athens and HINP, Athens, Greece O253100100012 REFERENCE (J,PR/C,102,064622,2020) O253100100013 #doi:10.1103/PhysRevC.102.064622 O253100100014 FACILITY (CYCLO,2ITYLNS) O253100100015 DETECTOR (MAGSP) MAGNEX magnetic spectrometer O253100100016 METHOD (BCINT) O253100100017 (EDE) O253100100018 STATUS (TABLE) Data received from A.Pakou. O253100100019 (APRVD) Approved by A.Pakou 21 July 2021. O253100100020 HISTORY (20200719R) Data received from A.Pakou. O253100100021 (20210719C) VS O253100100022 ENDBIB 20 0 O253100100023 NOCOMMON 0 0 O253100100024 ENDSUBENT 23 0 O253100199999 SUBENT O2531002 20210719 O084O253100200001 BIB 5 10 O253100200002 REACTION ((1-H-1(4-BE-9,EL)1-H-1,,DA)= O253100200003 (4-BE-9(P,EL)4-BE-9,,DA)) O253100200004 SAMPLE CH2 target with thickness of 303 ug/cm2 O253100200005 DETECTOR (TELES,TRD,SI) MAGNEX magnetic spectrometer focal planeO253100200006 gas and silicon detectors. O253100200007 ERR-ANALYS (ERR-S) Statistical uncertainties O253100200008 (ERR-1) Uncertainty due to flux determination - 5% O253100200009 (ERR-2) Uncertainty due to target - 10% O253100200010 (ERR-3) Uncertainty due to solid angle - 2% O253100200011 STATUS (TABLE) Plotted on Fig.5 of Phys.Rev.C102(2020)064622. O253100200012 ENDBIB 10 0 O253100200013 COMMON 4 3 O253100200014 EN ERR-1 ERR-2 ERR-3 O253100200015 MEV/A PER-CENT PER-CENT PER-CENT O253100200016 2.72 5. 10. 2. O253100200017 ENDCOMMON 3 0 O253100200018 DATA 3 16 O253100200019 ANG-CM DATA-CM ERR-S O253100200020 ADEG MB/SR MB/SR O253100200021 37.71 412.2 3.9 O253100200022 45.76 247.1 2.9 O253100200023 52.52 190.0 2.6 O253100200024 60.16 124. 1.9 O253100200025 69.37 88. 3.0 O253100200026 81.4 60. 2.1 O253100200027 87.9 56. 2.0 O253100200028 94.4 50. 1.9 O253100200029 101. 47. 1.6 O253100200030 107.7 42. 1.5 O253100200031 114.7 42. 1.4 O253100200032 122.1 42.5 1.2 O253100200033 130.34 45.5 1.4 O253100200034 136.98 47.5 1.5 O253100200035 142.74 50. 1.6 O253100200036 147.96 44.7 1.5 O253100200037 ENDDATA 18 0 O253100200038 ENDSUBENT 37 0 O253100299999 SUBENT O2531003 20210719 O084O253100300001 BIB 5 11 O253100300002 REACTION ((1-H-1(4-BE-9,D)4-BE-8,,DA)= O253100300003 (4-BE-9(P,D)4-BE-8,,DA,RSD)) O253100300004 DETECTOR (TELES,SISD,SISD) A telescope array GLORIA. The O253100300005 module comprised a deltaE Double-Sided Silicon Strip O253100300006 Detector and an E pad with thicknesses of 40 and 500 O253100300007 um, respectively. O253100300008 REL-REF (I,,G.Marquinez-Duran+,J,NIM/A,755,69,2014) O253100300009 GLORIA: A compact detector system for studying heavy O253100300010 ion reactions using radioactive beams. O253100300011 ERR-ANALYS (ERR-S) Statistical uncertainties O253100300012 STATUS (TABLE) Plotted on Fig.10 of Phys.Rev.C102(2020)064622.O253100300013 ENDBIB 11 0 O253100300014 COMMON 1 3 O253100300015 EN O253100300016 MEV/A O253100300017 2.72 O253100300018 ENDCOMMON 3 0 O253100300019 DATA 3 6 O253100300020 ANG-CM DATA-CM ERR-S O253100300021 ADEG MB/SR MB/SR O253100300022 57.16 7.00 0.07 O253100300023 61.9 6.08 0.07 O253100300024 66.45 5.82 0.07 O253100300025 71.31 5.68 0.07 O253100300026 76.26 5.55 0.07 O253100300027 81.04 5.19 0.07 O253100300028 ENDDATA 8 0 O253100300029 ENDSUBENT 28 0 O253100399999 SUBENT O2531004 20210720 O084O253100400001 BIB 7 12 O253100400002 REACTION ((1-H-1(4-BE-9,A)3-LI-6,PAR,DA,RSD)= O253100400003 (4-BE-9(P,A)3-LI-6,PAR,DA)) O253100400004 DETECTOR (TELES,TRD,SI) MAGNEX magnetic spectrometer focal planeO253100400005 gas and silicon detectors. O253100400006 REL-REF (I,,M.Cavallaro+,J,EPJ/A,48,59,2012) The low-pressure O253100400007 focal plane detector of the MAGNEX spectrometer. O253100400008 PART-DET (3-LI-6) O253100400009 ADD-RES Upper limit for the angle-integrated cross section O253100400010 33+/-15 mb and 240+/-55 mb for the total reaction O253100400011 cross section for this reaction channel. O253100400012 ERR-ANALYS (ERR-S) Statistical uncertainties O253100400013 STATUS (TABLE) Plotted on Fig.11 of Phys.Rev.C102(2020)064622.O253100400014 ENDBIB 12 0 O253100400015 COMMON 2 3 O253100400016 EN E-LVL O253100400017 MEV/A MEV O253100400018 2.72 3.562 O253100400019 ENDCOMMON 3 0 O253100400020 DATA 3 7 O253100400021 ANG-CM DATA-CM ERR-S O253100400022 ADEG MB/SR MB/SR O253100400023 101. 2.4 0.24 O253100400024 107. 2.5 0.25 O253100400025 114. 2. 0.2 O253100400026 121. 1.87 0.2 O253100400027 128.5 2.1 0.21 O253100400028 137. 2.34 0.234 O253100400029 147. 2.07 0.2 O253100400030 ENDDATA 9 0 O253100400031 ENDSUBENT 30 0 O253100499999 SUBENT O2531005 20210720 O084O253100500001 BIB 7 27 O253100500002 REACTION (1-H-1(4-BE-9,N+P+A)2-HE-4,,SIG) O253100500003 SAMPLE CH2 target with thickness of 492 ug/cm2. It was masked O253100500004 by a tantalum foil 18.2 um thick. O253100500005 DETECTOR (TELES,TRD,SI) MAGNEX magnetic spectrometer focal planeO253100500006 gas and silicon detectors for alpha1 detection. O253100500007 (TELES,SISD,SISD) A telescope array GLORIA for alpha2 O253100500008 and proton detection. O253100500009 A module comprised a deltaE Double-Sided Silicon Strip O253100500010 Detector and an E pad with thicknesses of 40 and 500 O253100500011 um, respectively. O253100500012 METHOD (COINC) Alpha1-alpha2-proton coincidences. O253100500013 ANALYSIS (DTBAL) The reduction of the data is based on a full O253100500014 kinematics approach by an event-by-event code with O253100500015 initial conditions on (a) alpha-particle gates and O253100500016 (b) proton recoil gates. O253100500017 A clear signature of a breakup event is then searched, O253100500018 obeying a triple coincidence requirement and tagged O253100500019 by energy and angle. When such an event is found, the O253100500020 energy and angle spectrum of the unobserved event, hereO253100500021 the neutron, can be reconstructed by applying the O253100500022 momentum conservation law. O253100500023 ERR-ANALYS (ERR-T) O253100500024 The major part of the error is due to the energy loss O253100500025 and straggling of alpha particles in the Ta foil. O253100500026 (ERR-4) Detector efficiency - 10% O253100500027 (ERR-S) Statistical uncertainties O253100500028 STATUS (TABLE) Table I of Phys.Rev.C102(2020)064622. O253100500029 ENDBIB 27 0 O253100500030 COMMON 2 3 O253100500031 ERR-S ERR-4 O253100500032 PER-CENT PER-CENT O253100500033 12. 10. O253100500034 ENDCOMMON 3 0 O253100500035 DATA 3 2 O253100500036 EN DATA ERR-T O253100500037 MEV/A MB MB O253100500038 2.72 2.5 1. O253100500039 5.67 142. 20. O253100500040 ENDDATA 4 0 O253100500041 ENDSUBENT 40 0 O253100599999 SUBENT O2531006 20210721 O084O253100600001 BIB 7 17 O253100600002 REACTION ((1-H-1(4-BE-9,N)5-B-9,,SIG)= O253100600003 (4-BE-9(P,N)5-B-9,,SIG)) O253100600004 SAMPLE CH2 target with thickness of 492 ug/cm2. It was masked O253100600005 by a tantalum foil 18.2 um thick. O253100600006 DETECTOR (TELES,TRD,SI) MAGNEX magnetic spectrometer focal planeO253100600007 gas and silicon detectors for alpha1 detection. O253100600008 (TELES,SISD,SISD) A telescope array GLORIA. O253100600009 A module comprised a deltaE Double-Sided Silicon Strip O253100600010 Detector and an E pad with thicknesses of 40 and 500 O253100600011 um, respectively. O253100600012 METHOD (COINC) Alpha1-alpha2-proton coincidences. O253100600013 ANALYSIS (DTBAL) The reduction of the data is based on a full O253100600014 kinematics approach by an event-by-event code with O253100600015 initial conditions on (a) alpha-particle gates and O253100600016 (b) Q-value gates. O253100600017 ERR-ANALYS (DATA-ERR) Reported total uncertainty. O253100600018 STATUS (TABLE) Text p. 064622-6 of Phys.Rev.C102(2020)064622. O253100600019 ENDBIB 17 0 O253100600020 NOCOMMON 0 0 O253100600021 DATA 3 1 O253100600022 EN DATA DATA-ERR O253100600023 MEV/A MB MB O253100600024 2.72 110. 40. O253100600025 ENDDATA 3 0 O253100600026 ENDSUBENT 25 0 O253100699999 ENDENTRY 6 0 O253199999999