ENTRY O2528 20210705 O084O252800000001 SUBENT O2528001 20210705 O084O252800100001 BIB 10 49 O252800100002 TITLE Can iodine be used as a contrast agent for O252800100003 protontherapy range verification? Measurement of the O252800100004 127I(p,n)127mXe (reaction) cross section in the O252800100005 4.5-10 MeV energy range O252800100006 AUTHOR (A.Espinosa Rodriguez, V.V.Onecha, V.Sanchez-Tembleque,O252800100007 C.Gutierrez-Neira, M.Garcia-Diez, P.Ibanez, S.Espana, O252800100008 D.Sanchez-Parcerisa, J.M.Udias, L.M.Fraile) O252800100009 INSTITUTE (2SPNAUT) O252800100010 (2SPNSPN) Universidad Complutense de Madrid, O252800100011 CEI Moncloa, Madrid, Spain O252800100012 (2SPNSPN) Instituto de Investigacion Del Hospital O252800100013 Clinico San Carlos, Ciudad Universitaria, Madrid, SpainO252800100014 (2SPNSPN) Centro Nacional de Investigaciones O252800100015 Cardiovasculares, Madrid, Spain O252800100016 REFERENCE (J,RPC,185,109485,2021) O252800100017 FACILITY (VDGT,2SPNAUT) Centro de Microanalisis de Materiales, O252800100018 CMAM-UAM, Madrid, Spain O252800100019 DETECTOR (SCIN) Four LaBr3(Ce) crystals placed at a distance O252800100020 of 4.5 cm from the center of the target and rotated O252800100021 60 degrees with respect to the beam direction. O252800100022 REL-REF (R,,J.F.Ziegler+,J,NIM/B,268,1818,2010) O252800100023 SRIM-The stopping and range of ions in matter. O252800100024 METHOD (BCINT,GSPEC) O252800100025 (ACTIV) O252800100026 Beam energy Irr. time O252800100027 (MeV) (s) O252800100028 CsI Zinc O252800100029 4.16 190 O252800100030 4.66 180 O252800100031 5.17 180 O252800100032 5.67 180 O252800100033 5.93 180 O252800100034 5.95 180 O252800100035 6.39 180 O252800100036 6.90 180 O252800100037 6.94 180 O252800100038 7.69 180 540 O252800100039 7.94 180 700 O252800100040 8.20 180 610 O252800100041 8.69 180 360 O252800100042 8.95 180 60 O252800100043 9.23 180 540 O252800100044 9.50 180 270 O252800100045 9.95 60 29 O252800100046 ERR-ANALYS (EN-ERR) The uncertainties in the energies stem from O252800100047 the error propagation from the intrinsic energy O252800100048 uncertainty of the incident beam, the kapton thickness O252800100049 and the uncertainties in the target position. O252800100050 HISTORY (20210705C) VS O252800100051 ENDBIB 49 0 O252800100052 NOCOMMON 0 0 O252800100053 ENDSUBENT 52 0 O252800199999 SUBENT O2528002 20210705 O084O252800200001 BIB 6 16 O252800200002 REACTION (53-I-127(P,N)54-XE-127-M,,PY,,TT) O252800200003 DECAY-DATA (54-XE-127-M,69.2SEC,DG,124.6,0.69, O252800200004 DG,172.5,0.38) O252800200005 SAMPLE High purity (99.9%) CsI powder was pressed into solid O252800200006 tablets with a radius of (6.5 +- 0.5) mm and a O252800200007 thickness of (1.7 +- 0.1) mm. O252800200008 ANALYSIS (DECAY) O252800200009 ERR-ANALYS (ERR-T) Total uncertainty estimated from: O252800200010 (ERR-1,2.1,5.7) Gamma-ray self-absorption in the targetO252800200011 (ERR-2,0.13,7.8) Activity determined by the fit of the O252800200012 decay curve; O252800200013 (ERR-3,0.32,0.76) Half-life; O252800200014 (ERR-4,0.65,1.7) Irradiation time; O252800200015 (ERR-5,4.5,10.) Detector system efficiency; O252800200016 (ERR-6,3.8,14.) Beam intensity. O252800200017 STATUS (TABLE) Table 5 of Radiat.Phys.Chem185(2020)109485 O252800200018 ENDBIB 16 0 O252800200019 NOCOMMON 0 0 O252800200020 DATA 4 17 O252800200021 EN EN-ERR DATA ERR-T O252800200022 MEV MEV PRD/INC PRD/INC O252800200023 4.16 0.04 0.0040 0.0009 O252800200024 4.66 0.04 0.013 0.002 O252800200025 5.17 0.03 0.05 0.005 O252800200026 5.67 0.03 0.21 0.02 O252800200027 5.93 0.04 0.61 0.07 O252800200028 5.95 0.03 0.38 0.04 O252800200029 6.39 0.03 0.84 0.07 O252800200030 6.90 0.03 2.0 0.2 O252800200031 6.94 0.04 2.8 0.3 O252800200032 6.94 0.03 2.6 0.2 O252800200033 7.69 0.03 6.0 0.3 O252800200034 7.94 0.03 9.5 1.1 O252800200035 8.20 0.03 11.7 0.7 O252800200036 8.69 0.03 18.4 1.1 O252800200037 8.95 0.03 20. 2. O252800200038 9.23 0.02 26. 2. O252800200039 9.95 0.02 41. 5. O252800200040 ENDDATA 19 0 O252800200041 ENDSUBENT 40 0 O252800299999 SUBENT O2528003 20210706 O084O252800300001 BIB 6 12 O252800300002 REACTION (30-ZN-64(P,N)31-GA-64,,PY,,TT) O252800300003 SAMPLE Natural 99.9% pure 0.8-mm-thick zinc foils. O252800300004 DECAY-DATA (31-GA-64,2.627MIN,DG,991.51,0.46) O252800300005 ANALYSIS (DECAY) O252800300006 ERR-ANALYS (ERR-T) Total uncertainty estimated from: O252800300007 (ERR-1,1.0,30.) Activity determined by the fit of the O252800300008 decay curve; O252800300009 (ERR-2,0.46) Half-life; O252800300010 (ERR-3,0.29,3.4) Irradiation time; O252800300011 (ERR-4,3.6,10.) Detector system efficiency; O252800300012 (ERR-5,5.1,19.) Beam intensity. O252800300013 STATUS (TABLE) Table 5 of Radiat.Phys.Chem185(2020)109485 O252800300014 ENDBIB 12 0 O252800300015 NOCOMMON 0 0 O252800300016 DATA 4 5 O252800300017 EN EN-ERR DATA ERR-T O252800300018 MEV MEV PRD/INC PRD/INC O252800300019 8.20 0.03 0.06 0.02 O252800300020 8.69 0.03 1.97 0.14 O252800300021 8.95 0.03 3.5 0.5 O252800300022 9.23 0.02 7.5 0.6 O252800300023 9.95 0.02 20. 3. O252800300024 ENDDATA 7 0 O252800300025 ENDSUBENT 24 0 O252800399999 SUBENT O2528004 20210705 O084O252800400001 BIB 7 20 O252800400002 REACTION (53-I-127(P,N)54-XE-127-M,,SIG,,,DERIV) O252800400003 DECAY-DATA (54-XE-127-M,69.2SEC,DG,124.6,0.69, O252800400004 DG,172.5,0.38) O252800400005 SAMPLE High purity (99.9%) CsI powder was pressed into solid O252800400006 tablets with a radius of (6.5 +- 0.5) mm and a O252800400007 thickness of (1.7 +- 0.1) mm. O252800400008 ANALYSIS The cross sections were derived from the thick target O252800400009 yields. O252800400010 FLAG (1.) Series 1 measurement. O252800400011 (2.) Series 2 measurement. O252800400012 ERR-ANALYS (ERR-T) Total uncertainty estimated from: O252800400013 (ERR-1,2.1,5.7) Gamma-ray self-absorption in the targetO252800400014 (ERR-2,0.13,7.8) Activity determined by the fit of the O252800400015 decay curve; O252800400016 (ERR-3,0.32,0.76) Half-life; O252800400017 (ERR-4,0.65,1.7) Irradiation time; O252800400018 (ERR-5,4.5,10.) Detector system efficiency; O252800400019 (ERR-6,3.8,14.) Beam intensity. O252800400020 STATUS (TABLE) Table 6 of Radiat.Phys.Chem185(2020)109485 O252800400021 (DEP,O2528002) Thick target yield O252800400022 ENDBIB 20 0 O252800400023 NOCOMMON 0 0 O252800400024 DATA 5 15 O252800400025 EN EN-ERR DATA ERR-T FLAG O252800400026 MEV MEV MB MB NO-DIM O252800400027 4.41 0.04 0.28 0.08 O252800400028 4.92 0.04 1.1 0.2 O252800400029 5.42 0.04 4.6 0.7 O252800400030 5.81 0.03 8. 2. O252800400031 6.17 0.03 14. 2. O252800400032 6.44 0.03 27. 4. O252800400033 6.65 0.03 29. 4. O252800400034 7.32 0.03 52. 7. O252800400035 7.44 0.03 77. 13. O252800400036 7.95 0.03 120. 20. O252800400037 8.45 0.03 110. 30. 1. O252800400038 8.45 0.03 150. 30. 2. O252800400039 8.96 0.03 150. 40. O252800400040 9.37 0.02 140. 40. O252800400041 9.45 0.02 200. 50. O252800400042 ENDDATA 17 0 O252800400043 ENDSUBENT 42 0 O252800499999 SUBENT O2528005 20210706 O084O252800500001 BIB 6 14 O252800500002 REACTION (30-ZN-64(P,N)31-GA-64,,SIG,,,DERIV) O252800500003 SAMPLE Natural 99.9% pure 0.8-mm-thick zinc foils. O252800500004 DECAY-DATA (31-GA-64,2.627MIN,DG,991.51,0.46) O252800500005 ANALYSIS The cross sections were derived from the thick target O252800500006 yields. O252800500007 ERR-ANALYS (ERR-T) Total uncertainty estimated from: O252800500008 (ERR-1,1.0,30.) Activity determined by the fit of the O252800500009 decay curve; O252800500010 (ERR-2,0.46) Half-life; O252800500011 (ERR-3,0.29,3.4) Irradiation time; O252800500012 (ERR-4,3.6,10.) Detector system efficiency; O252800500013 (ERR-5,5.1,19.) Beam intensity. O252800500014 STATUS (TABLE) Table 6 of Radiat.Phys.Chem185(2020)109485 O252800500015 (DEP,O2528003) Thick target yield O252800500016 ENDBIB 14 0 O252800500017 NOCOMMON 0 0 O252800500018 DATA 4 4 O252800500019 EN EN-ERR DATA ERR-T O252800500020 MEV MEV MB MB O252800500021 8.45 0.03 28. 5. O252800500022 8.96 0.03 70. 10. O252800500023 9.37 0.02 110. 30. O252800500024 9.45 0.02 114. 9. O252800500025 ENDDATA 6 0 O252800500026 ENDSUBENT 25 0 O252800599999 ENDENTRY 5 0 O252899999999