ENTRY O2518 20210307 O083O251800000001 SUBENT O2518001 20210307 O083O251800100001 BIB 13 32 O251800100002 TITLE New Cross-Sections for natMo(alpha,x) Reactions and O251800100003 Medical 97Ru Production Estimations with Radionuclide O251800100004 Yield Calculator O251800100005 AUTHOR (M.Sitarz,E.Nigron,A.Guertin,F.Haddad,T.Matulewicz) O251800100006 INSTITUTE (2FR ARN,2FR NTE,3POLWWA) O251800100007 FACILITY (CYCLO,2FR ARN) O251800100008 REFERENCE (J,INST,3,7,2019) O251800100009 #doi:10.3390/instruments3010007 O251800100010 METHOD (STTA,EDEG) A typical stacked-foil target consisted O251800100011 of an Al monitor foil in front, set of multiple natMo O251800100012 foils and Al degraders arranged alternately. O251800100013 (ACTIV) Irradiation time - 1 h Cooling time - 14 h O251800100014 (GSPEC) Each foil was placed at a height of 19 cm from O251800100015 the detector. O251800100016 DETECTOR (HPGE) O251800100017 SAMPLE Natural Mo foils with 99.9% purity and 10 um O251800100018 thickness. Al monitor foils with 99% purity and 10 um O251800100019 thickness. Al degrader foils with 50 to 500 um O251800100020 thickness O251800100021 MONITOR (13-AL-27(A,X)11-NA-24,,SIG) O251800100022 MONIT-REF (,A.Hermanne+,J,NDS,148,338,2018) O251800100023 ERR-ANALYS (EN-ERR) The energy errors were propagated with SRIM O251800100024 software. The cyclotron beam energy error 0.5 MeV. O251800100025 (ERR-T) The errors of cross-section values were O251800100026 propagated from: O251800100027 (ERR-1) the uncertainty of thickness measurements - 1% O251800100028 (ERR-S,5.,10.) the uncertainty of the counts in the O251800100029 gamma-line peaks in the spectroscopy measurements O251800100030 (ERR-2,5.,10.) the error of the beam current O251800100031 calculated from the monitor foils. O251800100032 STATUS (TABLE) Table 2 of Instr.3(2019)7 O251800100033 HISTORY (20210307C) VS O251800100034 ENDBIB 32 0 O251800100035 COMMON 1 3 O251800100036 ERR-1 O251800100037 PER-CENT O251800100038 1. O251800100039 ENDCOMMON 3 0 O251800100040 ENDSUBENT 39 0 O251800199999 SUBENT O2518002 20210307 O083O251800200001 BIB 2 3 O251800200002 REACTION (42-MO-0(A,X)44-RU-97,,SIG) O251800200003 DECAY-DATA (44-RU-97,2.83D,DG,215.7,0.858, O251800200004 DG,324.5,0.108) O251800200005 ENDBIB 3 0 O251800200006 NOCOMMON 0 0 O251800200007 DATA 4 9 O251800200008 EN EN-ERR DATA ERR-T O251800200009 MEV MEV MB MB O251800200010 41.80 0.75 237. 20. O251800200011 46.03 0.68 225. 20. O251800200012 50.00 0.64 199. 18. O251800200013 51.93 0.62 166. 14. O251800200014 55.30 0.60 159. 13. O251800200015 58.51 0.56 176. 15. O251800200016 59.97 0.55 176. 15. O251800200017 63.47 0.53 180. 16. O251800200018 66.84 0.50 173. 14. O251800200019 ENDDATA 11 0 O251800200020 ENDSUBENT 19 0 O251800299999 SUBENT O2518003 20210307 O083O251800300001 BIB 2 2 O251800300002 REACTION (42-MO-0(A,X)40-ZR-89-G,CUM,SIG) O251800300003 DECAY-DATA (40-ZR-89-G,78.4HR,DG,908.96,1.) O251800300004 ENDBIB 2 0 O251800300005 NOCOMMON 0 0 O251800300006 DATA 4 5 O251800300007 EN EN-ERR DATA ERR-T O251800300008 MEV MEV MB MB O251800300009 55.30 0.60 3.60 9. O251800300010 58.51 0.56 11.7 1.6 O251800300011 59.97 0.55 18. 2. O251800300012 63.47 0.53 30. 3. O251800300013 66.84 0.50 40. 3. O251800300014 ENDDATA 7 0 O251800300015 ENDSUBENT 14 0 O251800399999 SUBENT O2518004 20210307 O083O251800400001 BIB 2 2 O251800400002 REACTION (42-MO-0(A,X)43-TC-95-G,CUM,SIG) O251800400003 DECAY-DATA (43-TC-95-G,20.0HR,DG,765.8,0.9382) O251800400004 ENDBIB 2 0 O251800400005 NOCOMMON 0 0 O251800400006 DATA 4 9 O251800400007 EN EN-ERR DATA ERR-T O251800400008 MEV MEV MB MB O251800400009 41.80 0.75 81. 11. O251800400010 46.03 0.68 127. 14. O251800400011 50.00 0.64 163. 17. O251800400012 51.93 0.62 170. 16. O251800400013 55.30 0.60 177. 17. O251800400014 58.51 0.56 205. 17. O251800400015 59.97 0.55 174. 24. O251800400016 63.47 0.53 188. 16. O251800400017 66.84 0.50 203. 17. O251800400018 ENDDATA 11 0 O251800400019 ENDSUBENT 18 0 O251800499999 SUBENT O2518005 20210307 O083O251800500001 BIB 2 5 O251800500002 REACTION (42-MO-0(A,X)43-TC-96,,SIG) O251800500003 DECAY-DATA (43-TC-96-G,4.28D,DG,778.22,1., O251800500004 DG,812.58,0.82, O251800500005 DG,849.93,0.98, O251800500006 DG,1126.97,0.152) O251800500007 ENDBIB 5 0 O251800500008 NOCOMMON 0 0 O251800500009 DATA 4 9 O251800500010 EN EN-ERR DATA ERR-T O251800500011 MEV MEV MB MB O251800500012 41.80 0.75 73. 7. O251800500013 46.03 0.68 89. 8. O251800500014 50.00 0.64 100. 9. O251800500015 51.93 0.62 101. 9. O251800500016 55.30 0.60 109. 9. O251800500017 58.51 0.56 119. 10. O251800500018 59.97 0.55 116. 10. O251800500019 63.47 0.53 118. 10. O251800500020 66.84 0.50 122. 10. O251800500021 ENDDATA 11 0 O251800500022 ENDSUBENT 21 0 O251800599999 SUBENT O2518006 20210307 O083O251800600001 BIB 2 3 O251800600002 REACTION (42-MO-0(A,X)42-MO-99,,SIG) O251800600003 DECAY-DATA (42-MO-99,65.9HR,DG,140.51,0.8943, O251800600004 DG,739.50,0.1213) O251800600005 ENDBIB 3 0 O251800600006 NOCOMMON 0 0 O251800600007 DATA 4 8 O251800600008 EN EN-ERR DATA ERR-T O251800600009 MEV MEV MB MB O251800600010 41.80 0.75 7.5 1.0 O251800600011 46.03 0.68 10.1 1.2 O251800600012 50.00 0.64 11.4 1.3 O251800600013 51.93 0.62 12.8 1.3 O251800600014 55.30 0.60 13.5 1.4 O251800600015 59.97 0.55 14.0 1.5 O251800600016 63.47 0.53 15.0 1.7 O251800600017 66.84 0.50 15.6 1.3 O251800600018 ENDDATA 10 0 O251800600019 ENDSUBENT 18 0 O251800699999 ENDENTRY 6 0 O251899999999