ENTRY O2449 20200209 O077O244900000001 SUBENT O2449001 20200209 O077O244900100001 BIB 8 15 O244900100002 TITLE A new study of the 10B(p,alpha1gamma) 7Be reaction O244900100003 from 0.35 to 1.8 MeV O244900100004 AUTHOR (A.Caciolli,R.Depalo,V.Rigato) O244900100005 INSTITUTE (2ITYUPV,2ITYPAD) O244900100006 REFERENCE (J,EPJ/A,55,171,2019) O244900100007 #doi:10.1140/epja/i2019-12859-2 O244900100008 FACILITY (VDG,2ITYPAD) O244900100009 SAMPLE (5-B-10,ENR=0.92) Boron powder deposited onto thin O244900100010 self-supporting carbon foils (about 20 ug/cm2). O244900100011 Samples with 25, 60, and 100 ug/cm2 thickness of the B O244900100012 deposition were used in the experiment. O244900100013 The Boron, Oxygen and Nitrogen concentrations O244900100014 determined by proton-EBS measurements. O244900100015 METHOD (BCINT) O244900100016 HISTORY (20200209C) VS O244900100017 ENDBIB 15 0 O244900100018 NOCOMMON 0 0 O244900100019 ENDSUBENT 18 0 O244900199999 SUBENT O2449002 20200209 O077O244900200001 BIB 4 14 O244900200002 REACTION (5-B-10(P,A)4-BE-7,PAR,DA,G,4PI) O244900200003 DETECTOR (HPGE) High Purity Germanium (HPGe) detector of 50% O244900200004 relative efficiency placed at 90 degree. O244900200005 ERR-ANALYS (ERR-T) The total uncertainty determined using the O244900200006 following partial uncertainties: O244900200007 (ERR-1) beam energy loss in the target - 1% O244900200008 (ERR-2) beam charge - 1% O244900200009 (ERR-3) target analysis - 4% O244900200010 (ERR-4) radioactivity of the sources used in detectors O244900200011 calibration - 3% O244900200012 (ERR-5) Uncertainty of the parameterisation fit of the O244900200013 detector efficiency - 2% O244900200014 (ERR-S) Uncertainty of the counting statistics O244900200015 STATUS (TABLE) Table 3 of Eur.Phys.J.A 55(2019)171 O244900200016 ENDBIB 14 0 O244900200017 COMMON 8 6 O244900200018 E ANG EN-ERR ERR-1 ERR-2 ERR-3 O244900200019 ERR-4 ERR-5 O244900200020 KEV ADEG KEV PER-CENT PER-CENT PER-CENT O244900200021 PER-CENT PER-CENT O244900200022 429. 90. 1. 1. 1. 4.O244900200023 3. 2. O244900200024 ENDCOMMON 6 0 O244900200025 DATA 4 29 O244900200026 EN-CM DATA ERR-T ERR-S O244900200027 KEV MB MB MB O244900200028 348. 0.05 0.03 0.03 O244900200029 439. 0.07 0.05 0.05 O244900200030 529. 0.40 0.05 0.04 O244900200031 620. 0.72 0.07 0.06 O244900200032 665. 1.05 0.08 0.05 O244900200033 710. 1.51 0.1 0.06 O244900200034 756. 2.03 0.13 0.06 O244900200035 801. 2.57 0.19 0.12 O244900200036 846. 3.81 0.2 0.09 O244900200037 891. 4.72 0.3 0.09 O244900200038 937. 6.48 0.4 0.15 O244900200039 982. 8.11 0.5 0.19 O244900200040 1027. 10.6 0.7 0.19 O244900200041 1072. 13.8 0.9 0.3 O244900200042 1117. 18.4 1.2 0.3 O244900200043 1163. 25.34 1.5 0.02 O244900200044 1208. 39.4 2. 0.6 O244900200045 1253. 64.2 4. 0.8 O244900200046 1298. 105.0 6. 1.2 O244900200047 1343. 146.6 9. 0.2 O244900200048 1388. 156.0 10. 1.7 O244900200049 1434. 138.4 8. 1.6 O244900200050 1479. 111.7 7. 1.4 O244900200051 1524. 95.4 6. 1.2 O244900200052 1569. 82.4 5. 0.6 O244900200053 1614. 75.0 5. 0.6 O244900200054 1659. 71.3 4. 1.0 O244900200055 1705. 65.1 4. 1.0 O244900200056 1795. 64.9 4. 0.3 O244900200057 ENDDATA 31 0 O244900200058 ENDSUBENT 57 0 O244900299999 SUBENT O2449003 20200209 O077O244900300001 BIB 4 13 O244900300002 REACTION (5-B-10(P,A)4-BE-7,PAR,DA,G,4PI) O244900300003 DETECTOR (NAICR) NaI(Tl) detector placed at 45 degree O244900300004 ERR-ANALYS (ERR-T) The total uncertainty determined using the O244900300005 following partial uncertainties: O244900300006 (ERR-1) beam energy loss in the target - 1% O244900300007 (ERR-2) beam charge - 1% O244900300008 (ERR-3) target analysis - 4% O244900300009 (ERR-4) radioactivity of the sources used in detectors O244900300010 calibration - 3% O244900300011 (ERR-5) Uncertainty of the parameterisation fit of the O244900300012 detector efficiency - 3% O244900300013 (ERR-S) Uncertainty of the counting statistics O244900300014 STATUS (TABLE) Table 3 of Eur.Phys.J.A 55(2019)171 O244900300015 ENDBIB 13 0 O244900300016 COMMON 8 6 O244900300017 E ANG EN-ERR ERR-1 ERR-2 ERR-3 O244900300018 ERR-4 ERR-5 O244900300019 KEV ADEG KEV PER-CENT PER-CENT PER-CENT O244900300020 PER-CENT PER-CENT O244900300021 429. 45. 1. 1. 1. 4.O244900300022 3. 3. O244900300023 ENDCOMMON 6 0 O244900300024 DATA 4 21 O244900300025 EN-CM DATA ERR-T ERR-S O244900300026 KEV MB MB MB O244900300027 846. 3.30 0.2 0.11 O244900300028 891. 4.01 0.3 0.14 O244900300029 937. 5.73 0.3 0.18 O244900300030 982. 7.02 0.5 0.16 O244900300031 1027. 9.14 0.6 0.17 O244900300032 1072. 12.1 0.8 0.2 O244900300033 1117. 17.1 1.1 0.2 O244900300034 1163. 23.1 1.4 0.4 O244900300035 1208. 36.9 2. 0.5 O244900300036 1253. 63. 4. 0.5 O244900300037 1298. 108.3 7. 0.8 O244900300038 1343. 155.1 9. 0.9 O244900300039 1388. 167.3 10. 0.2 O244900300040 1434. 144.4 9. 1.1 O244900300041 1479. 115.3 7. 1.0 O244900300042 1524. 94.2 6. 0.9 O244900300043 1569. 84.2 5. 0.4 O244900300044 1614. 73.8 5. 0.5 O244900300045 1659. 67.1 4. 0.7 O244900300046 1705. 65.3 4. 0.8 O244900300047 1795. 58.3 4. 0.4 O244900300048 ENDDATA 23 0 O244900300049 ENDSUBENT 48 0 O244900399999 SUBENT O2449004 20200417 O077O244900400001 BIB 3 8 O244900400002 REACTION (5-B-10(P,A)4-BE-7,PAR,SIG,,SFC) O244900400003 ERR-ANALYS (DATA-ERR) A conservative 20% error added to the O244900400004 present results to account for the uncertainty on the O244900400005 interpolation. O244900400006 STATUS (DEP,O2359002) total 10B(p,alpha)7Be S-factor O244900400007 (DEP,O2449002) 10B(p,alpha1)7Be cross section O244900400008 (DEP,02449003) 10B(p,alpha1)7Be cross section O244900400009 (TABLE) Table 5 of Eur.Phys.J.A 55(2019)171 O244900400010 ENDBIB 8 0 O244900400011 COMMON 1 3 O244900400012 E-LVL O244900400013 MEV O244900400014 0. O244900400015 ENDCOMMON 3 0 O244900400016 DATA 3 8 O244900400017 EN-CM DATA DATA-ERR O244900400018 KEV B*MEV B*MEV O244900400019 249. 20.0 1.2 O244900400020 347. 14.4 0.9 O244900400021 446. 12.7 0.8 O244900400022 548. 9.2 0.6 O244900400023 647. 13.1 0.8 O244900400024 749. 10.4 0.6 O244900400025 900. 5.8 1.0 O244900400026 1182. 18.4 1.1 O244900400027 ENDDATA 10 0 O244900400028 ENDSUBENT 27 0 O244900499999 ENDENTRY 4 0 O244999999999