ENTRY O2444 20190324 O070O244400000001 SUBENT O2444001 20190324 O070O244400100001 BIB 10 29 O244400100002 TITLE First cross-section measurements of the reactions O244400100003 107,109Ag(p,gamma)108,110Cd at energies relevant to theO244400100004 p process O244400100005 AUTHOR (A.Khaliel,T.J.Mertzimekis,E.-M.Asimakopoulou, O244400100006 A.Kanellakopoulos,V.Lagaki,A.Psaltis,I.Psyrra, O244400100007 E.Mavrommatis) O244400100008 INSTITUTE (2GRCGRC) University of Athens, Zografou Campus, O244400100009 Athens, Greece O244400100010 REFERENCE (J,PR/C,96,035806,2017) O244400100011 #doi:10.1103/PhysRevC.96.035806 O244400100012 FACILITY (VDGT,2GRCATH) O244400100013 INC-SPECT The energy loss of the beam in the natAg target O244400100014 calculated using SRIM 2013 in the range deltaE 32-22 O244400100015 keV for the respective proton energy range Ep = 2.2 - O244400100016 4 MeV in the laboratory frame. Eeff = Ep - deltaE/2 O244400100017 DETECTOR (HPGE) Three high-purity germanium (HPGe) detectors O244400100018 of 100% relative efficiency placed at 0, 90, and 165 O244400100019 degrees and at respective distances of 30, 20, and O244400100020 20 cm from the target. No significant angular O244400100021 dependence was observed. O244400100022 METHOD (GSPEC) In-beam gamma -ray spectroscopy O244400100023 (BCINT) O244400100024 ERR-ANALYS (ERR-T) The total uncertainties determined from: O244400100025 - statistical uncertainty of the photopeak integration O244400100026 - the detector absolute efficiencies uncertainties O244400100027 (ERR-1) the uncertainty of the charge collected on the O244400100028 target - 5% O244400100029 (ERR-2) the uncertainty of the target's thickness - 7% O244400100030 HISTORY (20190324C) VS O244400100031 ENDBIB 29 0 O244400100032 COMMON 2 3 O244400100033 ERR-1 ERR-2 O244400100034 PER-CENT PER-CENT O244400100035 5. 7. O244400100036 ENDCOMMON 3 0 O244400100037 ENDSUBENT 36 0 O244400199999 SUBENT O2444002 20190324 O070O244400200001 BIB 3 4 O244400200002 REACTION 1(47-AG-107(P,G)48-CD-108,,SIG) O244400200003 2(47-AG-107(P,G)48-CD-108,,SIG,,SFC) O244400200004 SAMPLE (47-AG-107,NAT=0.51839) O244400200005 STATUS (TABLE) Table I of Phys.Rev.C96(2017)035806 O244400200006 ENDBIB 4 0 O244400200007 NOCOMMON 0 0 O244400200008 DATA 5 3 O244400200009 EN DATA 1ERR-T 1DATA 2ERR-T 2 O244400200010 KEV MICRO-B MICRO-B B*MEV B*MEV O244400200011 3989. 103. 10. 5.8E+6 0.6E+6 O244400200012 3488. 33. 3. 8.2E+6 0.8E+6 O244400200013 2184. 3.6 0.3 4.1E+8 4.E+7 O244400200014 ENDDATA 5 0 O244400200015 ENDSUBENT 14 0 O244400299999 SUBENT O2444003 20190324 O070O244400300001 BIB 3 8 O244400300002 REACTION 1(47-AG-109(P,G)48-CD-110,,SIG) O244400300003 2(47-AG-109(P,G)48-CD-110,,SIG,,SFC) O244400300004 SAMPLE (47-AG-109,NAT=0.48161) O244400300005 Sample thickness 458 +- 33 ug/cm2 determined by O244400300006 Rutherford backscattering technique. O244400300007 30 degree relative to beam. O244400300008 The effective thickness 529 +- 38 ug/cm2 O244400300009 STATUS (TABLE) Table II of Phys.Rev.C96(2017)035806 O244400300010 ENDBIB 8 0 O244400300011 NOCOMMON 0 0 O244400300012 DATA 5 3 O244400300013 EN DATA 1ERR-T 1DATA 2ERR-T 2 O244400300014 KEV MICRO-B MICRO-B B*MEV B*MEV O244400300015 3989. 20.6 4.6 1.2E+6 0.3E+6 O244400300016 3488. 7.2 2.4 1.8E+6 0.6E+6 O244400300017 2184. 0.14 0.59 1.6E+7 6.7E+7 O244400300018 ENDDATA 5 0 O244400300019 ENDSUBENT 18 0 O244400399999 ENDENTRY 3 0 O244499999999