ENTRY O2058 20190305 O068O205800000001 SUBENT O2058001 20190305 O068O205800100001 BIB 14 40 O205800100002 TITLE New measurement of the He-3(alpha,gamma)Be-7 cross O205800100003 section at medium energies. O205800100004 AUTHOR (M.Carmona-Gallardo, B.S.Nara Singh, M.J.G.Borge, O205800100005 J.A.Briz, M.Cubero, B.R.Fulton, H.Fynbo, N.Gordillo, O205800100006 M.Hass, G.Haquin, A.Maira, E.Nacher,Y.Nir-El, V.Kumar, O205800100007 J.McGrath, A.Munoz-Martin, A.Perea, V.Pesudo, O205800100008 G.Ribeiro, J.Sanchez del Rio, O.Tengblad, R.Yaniv, O205800100009 Z.Yungreis) O205800100010 REFERENCE (J,PR/C,86,032801,2012) O205800100011 REL-REF (M,,A.Gottdang+,J,NIM/B,190,177,2002) O205800100012 (M,O1268001,B.S.Nara Singh+,J,PRL,93,262503,2004) O205800100013 INSTITUTE (2SPNAUT) CSIC, Madrid, Spain and CMAM, Madrid O205800100014 (2UK YRK,2DENAAU,3ISLWZI,3ISLSOR) O205800100015 FACILITY (CCW,2SPNAUT) 5 MV Cockcroft-Walton accelerator CMAM O205800100016 SAMPLE The He-3 beam impinged onto the He-4 gas target after O205800100017 passing through a nickel (Ni) foil window that O205800100018 isolated the beam line from the target gas inside the O205800100019 chamber. O205800100020 METHOD (BCINT) O205800100021 (GSPEC) O205800100022 ERR-ANALYS (DATA-ERR).Systematic error is reported in table. O205800100023 (ERR-1).Error in the gamma-counting statistics O205800100024 (ERR-2,,0.2).The uncertainty in the energy up to 0.2%. O205800100025 (ERR-3).The uncertainty from charge integration approx.O205800100026 2.0%. O205800100027 (ERR-4).The uncertainty in the number of He-4 atoms perO205800100028 cm**2 in the chamber is approx. 0.8% O205800100029 MONITOR (28-NI-0(HE3,EL)28-NI-0,,DA) O205800100030 COMMENT *By author*.The energies of the beam from the O205800100031 accelerator were determined by using the 27Al(p,g)28Si O205800100032 resonance at E(p)=991.2 keV and an upper limit of 5 keVO205800100033 uncertainty was estimated based on the observed O205800100034 systematics in experiments carried out at CMAM using O205800100035 several different beams. O205800100036 DETECTOR (HPGE) 20 mm from the high-purity HPGe detector O205800100037 (SIBAR) For the elastically scattered beam particles O205800100038 from the Ni-window. O205800100039 STATUS (TABLE).Table 1 of J,PR/C,86,032801,2012 O205800100040 HISTORY (20121010C) sb O205800100041 (20190305U) SD: In FACILITY and INSTITUTE codes updatedO205800100042 ENDBIB 40 0 O205800100043 COMMON 2 3 O205800100044 ERR-3 ERR-4 O205800100045 PER-CENT PER-CENT O205800100046 2.0 0.8 O205800100047 ENDCOMMON 3 0 O205800100048 ENDSUBENT 47 0 O205800199999 SUBENT O2058002 20121021 O050O205800200001 BIB 2 10 O205800200002 REACTION 1(2-HE-3(A,G)4-BE-7,,SIG) O205800200003 2(2-HE-3(A,G)4-BE-7,,SIG,,SFC) O205800200004 the astrophysical S factor based on the integrated O205800200005 charge on the chamber. O205800200006 FLAG (1.).The cross sections values obtained by using the O205800200007 number of beam particles deduced using the integrated O205800200008 charge on the chamber. O205800200009 (2.).The cross sections values obtained by using the O205800200010 number of beam particles deduced using the integrated O205800200011 charge on the silicon spectra. O205800200012 ENDBIB 10 0 O205800200013 NOCOMMON 0 0 O205800200014 DATA 8 6 O205800200015 EN-CM DATA 1DATA-ERR 1ERR-1 1DATA 2DATA-ERR 2O205800200016 ERR-1 2FLAG O205800200017 KEV MICRO-B MICRO-B MICRO-B B*KEV B*KEV O205800200018 B*KEV NO-DIM O205800200019 1054. 2.05 0.14 0.07 0.34 0.02 O205800200020 0.01 1. O205800200021 1054. 2.14 0.15 0.11 0.34 0.02 O205800200022 0.01 2. O205800200023 2007. 4.70 0.12 0.13 0.37 0.01 O205800200024 0.01 1. O205800200025 2007. 4.59 0.12 0.24 0.37 0.01 O205800200026 0.01 2. O205800200027 2804. 6.82 0.29 0.18 0.42 0.01 O205800200028 0.01 1. O205800200029 2804. 6.68 0.29 0.35 0.42 0.01 O205800200030 0.01 2. O205800200031 ENDDATA 16 0 O205800200032 ENDSUBENT 31 0 O205800299999 ENDENTRY 2 0 O205899999999