ENTRY O1873 20101206 O044O187300000001 SUBENT O1873001 20101206 O044O187300100001 BIB 14 42 O187300100002 TITLE Radiative proton capture to discrete states in C-12 at O187300100003 98 and 176 MeV. O187300100004 REFERENCE (J,NP/A,603,1,1996) O187300100005 AUTHOR (T.B.Bright, B.Hoeistad, R.Johansson, E.Traneus, O187300100006 S.R.Cotanch) O187300100007 INSTITUTE (2SWDUPP) O187300100008 (1USANCS) O187300100009 SAMPLE A self-supporting disc of 47.6 mg/cm**2 of B-11, O187300100010 produced from 100% isotopically enriched B-11 powder O187300100011 mixed with 2% organic binder, was used. O187300100012 REL-REF (I,,B.Hoeistad+,J,NIM/A,295,172,1990) A comprehensive O187300100013 description of PACMAN spectrometer. O187300100014 DETECTOR (SPEC) The experimental set-up consists of a magnetic O187300100015 pair spectrometer PACMAN, a beam monitoring system O187300100016 including two threefold scintillation telescopes aimed O187300100017 at the target and two ion chambers placed in the beam O187300100018 behind the scattering chamber. O187300100019 FACILITY (ISOCY,2SWDUPP) Gustav Werner cyclotron. O187300100020 METHOD (EXTB) The beam was focused to a 5 mm diameter beam O187300100021 spot. O187300100022 CORRECTION Corrections according to the instrumental acceptance O187300100023 function, for losses due to the analyzing procedure, O187300100024 for overall detection inefficiencies. O187300100025 HISTORY (20101206C) sb O187300100026 STATUS (TABLE).Table 1 of J,NP/A,603,1,1996 O187300100027 ERR-ANALYS (ERR-SYS).The total systematic error to about 10%. O187300100028 The track reconstruction efficiency is determined, O187300100029 for each run, from a sample of recorded events, and it O187300100030 is therefore subjected to statistical fluctuations. O187300100031 This leads to a typically 4% error that is not includedO187300100032 in the systematic error, but rather is added directly O187300100033 to the statistical error in the differential cross O187300100034 section. O187300100035 (ERR-1).Error in the target -2% O187300100036 (ERR-2).Error in the beam intensity-7%, O187300100037 (ERR-3).Error in the acceptance calculation-7% and the O187300100038 (ERR-4).Error in intensity-independent detection O187300100039 efficiency-2%. O187300100040 (ERR-S).Statistical error is reported by authors in O187300100041 table. O187300100042 ADD-RES (THEO) Model calculation. O187300100043 (P-SPC) O187300100044 ENDBIB 42 0 O187300100045 COMMON 5 3 O187300100046 ERR-SYS ERR-1 ERR-2 ERR-3 ERR-4 O187300100047 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT O187300100048 10. 2. 7. 7. 2. O187300100049 ENDCOMMON 3 0 O187300100050 ENDSUBENT 49 0 O187300199999 SUBENT O1873002 20101207 O044O187300200001 BIB 4 7 O187300200002 REACTION (5-B-11(P,G)6-C-12,PAR,DA) O187300200003 PART-DET (G) O187300200004 EN-SEC (E-LVL,6-C-12) O187300200005 LEVEL-PROP (6-C-12,E-LVL=0.000,SPIN=0.,PARITY=+1.) O187300200006 (6-C-12,E-LVL=4.400,SPIN=2.,PARITY=+1.) O187300200007 (6-C-12,E-LVL=7.700,SPIN=0.,PARITY=+1.) O187300200008 (6-C-12,E-LVL=9.600,SPIN=3.,PARITY=-1.) O187300200009 ENDBIB 7 0 O187300200010 NOCOMMON 0 0 O187300200011 DATA 5 52 O187300200012 EN E-LVL ANG DATA ERR-S O187300200013 MEV MEV ADEG NB/SR NB/SR O187300200014 98. 0.0 37.5 75.8 4.5 O187300200015 98. 0.0 45.0 69.1 2.7 O187300200016 98. 0.0 60.0 36.2 2.1 O187300200017 98. 0.0 80.0 11.4 1.1 O187300200018 98. 0.0 100.0 1.75 0.37 O187300200019 98. 0.0 120.0 0.67 0.17 O187300200020 98. 0.0 140.0 0.92 0.19 O187300200021 98. 4.4 37.5 82.8 4.5 O187300200022 98. 4.4 45.0 82.9 3.1 O187300200023 98. 4.4 60.0 62.3 2.9 O187300200024 98. 4.4 80.0 35.3 2.2 O187300200025 98. 4.4 100.0 14.3 1.1 O187300200026 98. 4.4 120.0 7.47 0.61 O187300200027 98. 4.4 140.0 5.41 0.49 O187300200028 98. 7.7 37.5 17.7 1.9 O187300200029 98. 7.7 45.0 18.3 2.1 O187300200030 98. 7.7 60.0 11.3 1.1 O187300200031 98. 7.7 80.0 4.04 0.64 O187300200032 98. 7.7 100.0 2.29 0.43 O187300200033 98. 7.7 120.0 1.01 0.21 O187300200034 98. 7.7 140.0 0.87 0.20 O187300200035 98. 9.6 37.5 53.8 3.3 O187300200036 98. 9.6 45.0 51.2 3.6 O187300200037 98. 9.6 60.0 34.6 1.9 O187300200038 98. 9.6 80.0 16.9 1.3 O187300200039 98. 9.6 100.0 4.91 0.61 O187300200040 98. 9.6 120.0 2.80 0.36 O187300200041 98. 9.6 140.0 2.67 0.34 O187300200042 176. 0.0 45.0 11.89 0.68 O187300200043 176. 0.0 60.0 3.81 0.77 O187300200044 176. 0.0 80.0 0.55 0.14 O187300200045 176. 0.0 100.0 0.24 0.09 O187300200046 176. 0.0 120.0 0.31 0.08 O187300200047 176. 0.0 140.0 0.35 0.07 O187300200048 176. 4.4 45.0 27.9 1.2 O187300200049 176. 4.4 60.0 13.2 1.4 O187300200050 176. 4.4 80.0 6.94 0.52 O187300200051 176. 4.4 100.0 1.87 0.25 O187300200052 176. 4.4 120.0 0.72 0.12 O187300200053 176. 4.4 140.0 0.21 0.06 O187300200054 176. 7.7 45.0 4.95 1.03 O187300200055 176. 7.7 60.0 2.46 0.58 O187300200056 176. 7.7 80.0 0.50 0.29 O187300200057 176. 7.7 100.0 0.36 0.16 O187300200058 176. 7.7 120.0 0.24 0.09 O187300200059 176. 7.7 140.0 0.12 0.05 O187300200060 176. 9.6 45.0 3.68 0.85 O187300200061 176. 9.6 60.0 3.65 0.70 O187300200062 176. 9.6 80.0 1.67 0.37 O187300200063 176. 9.6 100.0 0.35 0.19 O187300200064 176. 9.6 120.0 0.18 0.09 O187300200065 176. 9.6 140.0 0.09 0.07 O187300200066 ENDDATA 54 0 O187300200067 ENDSUBENT 66 0 O187300299999 ENDENTRY 2 0 O187399999999