ENTRY O1736 20160730 O058O173600000001 SUBENT O1736001 20160730 O058O173600100001 BIB 16 57 O173600100002 TITLE Excitation functions of (p,xn) reactions on natural O173600100003 tellurium at low energy cyclotron: relevance to the O173600100004 production of medical radioisotope I-123 O173600100005 AUTHOR (K.Zarie, N.A.Hammad, A.Azzam) O173600100006 INSTITUTE (3EGYCAI) O173600100007 (3SARRIY) O173600100008 REFERENCE (J,NRP,1,93,2006) O173600100009 FACILITY (CYCLO,3EGYCAI) CS30 cyclotron at King Faisal O173600100010 Specialized Hospital and Research Center. O173600100011 SAMPLE High purity natural tellurium, more than 99.9%, naturalO173600100012 isotopic abundance in %-Te-120 0.096, Te-122 2.603, O173600100013 Te-123 0.908 Te-124 4.186 Te-125 7.139, Te-126 18.95, O173600100014 Te-128 31.69 and Te-130 33.80, was used as target O173600100015 material. O173600100016 Thin target samples were prepared by electrodepositing O173600100017 Te onto 12 mum thick Ti foils, more than 99.9%, of 8 mmO173600100018 diameter. The deposited target was covered by 50 mum O173600100019 thick pure al foil, more than 99.9%., to protect tham O173600100020 and avoid any loss of Te or radioiodine. The sandwich O173600100021 sample was Ti-Te-Al. O173600100022 Two stacks (a total of 38 sandwich samples and several O173600100023 10 mum thick Cu foils were used. O173600100024 MONITOR (29-CU-0(P,X)30-ZN-62,,SIG) O173600100025 (29-CU-0(P,X)30-ZN-63,,SIG) O173600100026 (29-CU-0(P,X)30-ZN-65,,SIG) for beam current monitored O173600100027 (22-TI-0(P,X)23-V-48,,SIG) O173600100028 MONIT-REF (,F.Tarkanyi+,R,IAEA-TECDOC-1211,49,2001) O173600100029 DECAY-MON (23-V-48,15.97D,DG,983.52,0.9998,DG,1312.09,0.975, O173600100030 DG,944.1,0.0776) O173600100031 (30-ZN-62,9.26HR,DG,596.7,0.257,DG,548.4,0.152) O173600100032 (30-ZN-63,38.4MIN,DG,669.8,0.085) O173600100033 (30-ZN-65,224.26D,DG,1115.5,0.506) O173600100034 METHOD (STTA) O173600100035 (BCINT) O173600100036 (EXTB) O173600100037 DETECTOR (HPGE) O173600100038 The detector absolute efficiency was about 42% while O173600100039 its resolution was 1.9 keV at the 1.33 MeV gamma-line O173600100040 of Co-60. O173600100041 ERR-ANALYS (ERR-T) The total error in the measured cross section O173600100042 10-15% was obtained by combining uncertainty on each O173600100043 measured cross section value, by taking the square rootO173600100044 of the summation of the following contributing sources:O173600100045 (ERR-1) The uncertainty on number of target atoms. O173600100046 (ERR-2) The uncertainty on nuclear data. O173600100047 (ERR-3) The uncertainty on beam intensity. O173600100048 (ERR-4,3.,7.) The uncertainty on absolute efficiency O173600100049 of the spectrometer. O173600100050 (ERR-S,1.,10.)Statistical and peak fitting uncertainty.O173600100051 ADD-RES (TTY-C) The integral yield of I-123 with its O173600100052 radionuclide impurity I-121,124,126,128,130 were O173600100053 calculated from the measured cross section data. O173600100054 REL-REF (A,A0473001,B.Scholten+,J,ARI,40,127,1989) O173600100055 STATUS (TABLE) Table 3 from NRP,1,93,2006 O173600100056 HISTORY (20090420C) SB O173600100057 (20160730U) SD: Small correction in MONIT-REF. O173600100058 ERR-5 -> ERR-S. DATA-ERR -> ERR-T in Subents 002-007. O173600100059 ENDBIB 57 0 O173600100060 COMMON 3 3 O173600100061 ERR-1 ERR-2 ERR-3 O173600100062 PER-CENT PER-CENT PER-CENT O173600100063 5. 5. 7. O173600100064 ENDCOMMON 3 0 O173600100065 ENDSUBENT 64 0 O173600199999 SUBENT O1736002 20160730 O058O173600200001 BIB 2 2 O173600200002 REACTION (52-TE-0(P,X)53-I-121,,SIG) O173600200003 DECAY-DATA (53-I-121,2.12HR,DG,212.19,0.84) O173600200004 ENDBIB 2 0 O173600200005 NOCOMMON 0 0 O173600200006 DATA 3 31 O173600200007 EN DATA ERR-T O173600200008 MEV MB MB O173600200009 7.335 0.93 0.14 O173600200010 10.111 1.27 0.19 O173600200011 11.006 1.65 0.25 O173600200012 12.805 2.12 0.32 O173600200013 13.569 3.28 0.49 O173600200014 14.283 4.16 0.62 O173600200015 14.965 4.62 0.69 O173600200016 15.588 6.08 0.91 O173600200017 16.188 8.44 1.27 O173600200018 16.787 11.47 1.72 O173600200019 17.362 15.93 2.39 O173600200020 17.925 16.87 2.53 O173600200021 18.472 17.86 2.68 O173600200022 19.013 20.99 3.15 O173600200023 19.543 19.18 2.88 O173600200024 20.062 27.97 4.20 O173600200025 20.566 31.84 4.78 O173600200026 21.062 65.86 9.88 O173600200027 21.551 98.12 14.72 O173600200028 22.026 105.94 15.89 O173600200029 22.506 141.94 21.29 O173600200030 22.984 184.44 27.67 O173600200031 23.441 268.30 40.25 O173600200032 23.886 307.11 46.07 O173600200033 24.325 329.59 49.44 O173600200034 24.757 358.08 53.71 O173600200035 25.183 361.67 54.25 O173600200036 25.609 365.04 54.76 O173600200037 26.028 367.90 55.18 O173600200038 26.448 361.98 54.3 O173600200039 26.855 360.47 54.07 O173600200040 ENDDATA 33 0 O173600200041 ENDSUBENT 40 0 O173600299999 SUBENT O1736003 20160730 O058O173600300001 BIB 2 2 O173600300002 REACTION (52-TE-0(P,X)53-I-123,,SIG) O173600300003 DECAY-DATA (53-I-123,13.27HR,DG,158.97,0.83) O173600300004 ENDBIB 2 0 O173600300005 NOCOMMON 0 0 O173600300006 DATA 3 34 O173600300007 EN DATA ERR-T O173600300008 MEV MB MB O173600300009 4.812 0.04 0.01 O173600300010 7.335 0.93 0.14 O173600300011 8.355 1.41 0.21 O173600300012 9.267 1.91 0.29 O173600300013 10.111 2.18 0.33 O173600300014 11.006 5.26 0.79 O173600300015 12.805 12.14 1.82 O173600300016 13.569 19.81 2.97 O173600300017 14.283 35.30 5.30 O173600300018 14.965 38.50 5.78 O173600300019 15.588 42.20 6.33 O173600300020 16.188 47.45 7.12 O173600300021 16.787 48.88 7.66 O173600300022 17.362 51.87 7.78 O173600300023 17.925 54.45 8.17 O173600300024 18.472 51.19 7.53 O173600300025 19.013 51.88 7.68 O173600300026 19.543 55.16 8.27 O173600300027 20.062 60.04 9.01 O173600300028 20.566 67.29 10.09 O173600300029 21.062 81.87 12.28 O173600300030 21.551 96.79 14.52 O173600300031 22.026 109.68 16.45 O173600300032 22.506 125.65 18.85 O173600300033 22.984 131.29 19.69 O173600300034 23.441 138.32 20.75 O173600300035 23.886 140.78 21.12 O173600300036 24.325 149.45 22.42 O173600300037 24.757 155.33 23.30 O173600300038 25.183 152.64 22.89 O173600300039 25.609 154.89 23.23 O173600300040 26.028 159.74 23.96 O173600300041 26.448 156.92 23.54 O173600300042 26.855 159.72 23.96 O173600300043 ENDDATA 36 0 O173600300044 ENDSUBENT 43 0 O173600399999 SUBENT O1736004 20160730 O058O173600400001 BIB 2 3 O173600400002 REACTION (52-TE-0(P,X)53-I-124,,SIG) O173600400003 DECAY-DATA (53-I-124,4.17D,DG,602.73,0.63,DG,1690.88,0.1088, O173600400004 DG,722.7,0.1035) O173600400005 ENDBIB 3 0 O173600400006 NOCOMMON 0 0 O173600400007 DATA 3 34 O173600400008 EN DATA ERR-T O173600400009 MEV MB MB O173600400010 4.812 0.44 0.07 O173600400011 7.335 1.59 0.24 O173600400012 8.355 0.92 0.14 O173600400013 9.267 3.34 0.50 O173600400014 10.111 9.27 1.39 O173600400015 11.006 18.54 2.78 O173600400016 12.805 32.88 4.93 O173600400017 13.569 59.78 8.97 O173600400018 14.283 74.63 11.19 O173600400019 14.965 76.97 11.55 O173600400020 15.588 84.57 12.69 O173600400021 16.188 82.03 12.30 O173600400022 16.787 87.91 13.19 O173600400023 17.362 88.70 13.31 O173600400024 17.925 90.22 13.53 O173600400025 18.472 89.89 13.48 O173600400026 19.013 81.56 12.23 O173600400027 19.543 79.40 11.91 O173600400028 20.062 82.56 12.38 O173600400029 20.566 85.83 12.87 O173600400030 21.062 87.83 13.17 O173600400031 21.551 89.41 13.41 O173600400032 22.026 91.67 13.75 O173600400033 22.506 93.84 14.08 O173600400034 22.984 92.52 13.88 O173600400035 23.441 92.69 13.90 O173600400036 23.886 90.06 13.51 O173600400037 24.325 93.25 13.99 O173600400038 24.757 93.50 14.03 O173600400039 25.183 90.99 13.65 O173600400040 25.609 94.9 14.24 O173600400041 26.028 93.91 14.08 O173600400042 26.448 95.12 14.27 O173600400043 26.855 96.88 14.53 O173600400044 ENDDATA 36 0 O173600400045 ENDSUBENT 44 0 O173600499999 SUBENT O1736005 20160730 O058O173600500001 BIB 2 2 O173600500002 REACTION (52-TE-0(P,X)53-I-126,,SIG) O173600500003 DECAY-DATA (53-I-126,13.11D,DG,666.33,0.331,DG,753.81,0.0416) O173600500004 ENDBIB 2 0 O173600500005 NOCOMMON 0 0 O173600500006 DATA 3 34 O173600500007 EN DATA ERR-T O173600500008 MEV MB MB O173600500009 4.812 1.37 0.21 O173600500010 7.335 9.26 1.39 O173600500011 8.355 24.03 3.60 O173600500012 9.267 56.04 8.41 O173600500013 10.111 70.95 10.64 O173600500014 11.006 89.80 13.47 O173600500015 12.805 83.23 12.49 O173600500016 13.569 78.88 11.83 O173600500017 14.283 55.42 8.31 O173600500018 14.965 30.56 4.58 O173600500019 15.588 21.24 3.19 O173600500020 16.188 16.91 2.55 O173600500021 16.787 13.23 1.98 O173600500022 17.362 11.51 1.73 O173600500023 17.925 9.38 1.41 O173600500024 18.472 5.93 0.89 O173600500025 19.013 7.39 1.12 O173600500026 19.543 7.46 1.12 O173600500027 20.062 9.71 1.46 O173600500028 20.566 8.34 1.25 O173600500029 21.062 13.87 2.08 O173600500030 21.551 18.26 2.74 O173600500031 22.026 22.86 3.43 O173600500032 22.506 28.44 4.23 O173600500033 22.984 35.39 5.31 O173600500034 23.441 38.99 5.84 O173600500035 23.886 40.78 6.12 O173600500036 24.325 41.30 6.19 O173600500037 24.757 43.64 6.55 O173600500038 25.183 49.98 7.50 O173600500039 25.609 53.87 8.08 O173600500040 26.028 52.44 7.87 O173600500041 26.448 54.19 8.13 O173600500042 26.855 59.61 8.94 O173600500043 ENDDATA 36 0 O173600500044 ENDSUBENT 43 0 O173600599999 SUBENT O1736006 20160730 O058O173600600001 BIB 2 2 O173600600002 REACTION (52-TE-0(P,X)53-I-128,,SIG) O173600600003 DECAY-DATA (53-I-128,24.99MIN,DG,442.22,0.17) O173600600004 ENDBIB 2 0 O173600600005 NOCOMMON 0 0 O173600600006 DATA 3 25 O173600600007 EN DATA ERR-T O173600600008 MEV MB MB O173600600009 9.711 49.32 7.39 O173600600010 10.588 73.97 11.09 O173600600011 11.414 85.74 12.86 O173600600012 13.56 52.99 7.99 O173600600013 13.569 53.25 7.99 O173600600014 15.786 39.50 5.92 O173600600015 16.046 34.69 5.20 O173600600016 18.472 17.84 2.67 O173600600017 19.543 13.89 2.08 O173600600018 20.062 3.04 0.46 O173600600019 20.566 0.86 0.13 O173600600020 21.062 1.47 0.22 O173600600021 21.551 2.17 0.35 O173600600022 22.026 2.05 0.31 O173600600023 22.506 3.15 0.47 O173600600024 22.984 3.07 0.46 O173600600025 23.441 3.66 0.55 O173600600026 23.886 4.07 0.61 O173600600027 24.325 4.46 0.67 O173600600028 24.757 4.13 0.62 O173600600029 25.183 4.47 0.67 O173600600030 25.609 4.52 0.68 O173600600031 26.028 4.52 0.68 O173600600032 26.448 4.73 0.71 O173600600033 26.855 4.62 0.69 O173600600034 ENDDATA 27 0 O173600600035 ENDSUBENT 34 0 O173600699999 SUBENT O1736007 20160730 O058O173600700001 BIB 3 5 O173600700002 REACTION (52-TE-0(P,X)53-I-130-G,M+,SIG) (IT(m.s.)=84%). O173600700003 DECAY-DATA (53-I-130-G,12.36HR,DG,536.09,0.99,DG,668.54,0.96, O173600700004 DG,739.48,0.82) O173600700005 HISTORY (20160730A) SD: SF4=I-130 -> I-130g, SF5=+M added O173600700006 to REACTION code. O173600700007 ENDBIB 5 0 O173600700008 NOCOMMON 0 0 O173600700009 DATA 3 34 O173600700010 EN DATA ERR-T O173600700011 MEV MB MB O173600700012 4.812 0.98 0.15 O173600700013 7.335 4.65 0.70 O173600700014 8.355 10.19 1.53 O173600700015 9.267 50.75 7.61 O173600700016 10.111 93.37 14.01 O173600700017 11.006 95.83 14.38 O173600700018 12.805 89.10 13.37 O173600700019 13.569 80.01 12.00 O173600700020 14.283 74.54 11.18 O173600700021 14.965 71.33 10.70 O173600700022 15.588 68.38 10.26 O173600700023 16.188 69.41 10.41 O173600700024 16.787 68.93 10.33 O173600700025 17.362 68.22 10.23 O173600700026 17.925 70.09 10.51 O173600700027 18.472 68.08 10.21 O173600700028 19.013 67.99 10.19 O173600700029 19.543 69.33 10.40 O173600700030 20.062 69.73 10.46 O173600700031 20.566 69.08 10.36 O173600700032 21.062 67.07 10.06 O173600700033 21.551 69.17 10.38 O173600700034 22.026 68.48 10.27 O173600700035 22.506 67.26 10.09 O173600700036 22.984 68.15 10.22 O173600700037 23.441 68.64 10.30 O173600700038 23.886 66.43 9.96 O173600700039 24.325 68.33 10.25 O173600700040 24.757 68.46 10.27 O173600700041 25.183 65.98 9.90 O173600700042 25.609 68.32 10.25 O173600700043 26.028 66.37 9.96 O173600700044 26.448 69.81 10.47 O173600700045 26.855 64.56 9.68 O173600700046 ENDDATA 36 0 O173600700047 ENDSUBENT 46 0 O173600799999 ENDENTRY 7 0 O173699999999