ENTRY O1726 20181104 O068O172600000001 SUBENT O1726001 20181104 O068O172600100001 BIB 11 34 O172600100002 TITLE Complete and incomplete fusion of Li-6 ions with Bi O172600100003 and Pt. O172600100004 AUTHOR (Yu.E.Penionzhkevich,S.M.Lukyanov, R.A.Astabatyan, O172600100005 N.A.Demekhina, M.P.Ivanov, R.Kalpakchieva, A.A.Kulko, O172600100006 E.R.Markaryan, V.A.Maslov, Yu.A.Muzychka, R.V.Revenko, O172600100007 N.K.Skobelev, V.I.Smirnov, Yu.G.Sobolev) O172600100008 INSTITUTE (4ZZZDUB) O172600100009 REFERENCE (J,JP/G,36,025104,2009) O172600100010 (J,JP/CS,420,012068,2013) Bi + 6Li O172600100011 (J,IMP/E,17,2349,2008) Pt + 6Li reaction O172600100012 (J,FCY/L,6,342,2009) Pt + 6Li reaction O172600100013 (J,PPN/L,6,208,2009) Trasl. of FCY/L,6,342,2009 O172600100014 FACILITY (CYCLO,4ZZZDUB) the U400 heavy-ion cyclotron of FLNR, O172600100015 JINR, Dubna O172600100016 METHOD (STTA) Stacked-foil activation technique. O172600100017 (ACTIV) O172600100018 DETECTOR (MAGSP) MSP-144 magnetic spectrometer for measuring O172600100019 energy and as an energy monochromatizer. O172600100020 COMMENT *By authors*.The products of complete and incomplete O172600100021 fusion from the interaction of Li-6 with Bi-209 are O172600100022 mostly alpha-radioactive. The products of the platinum O172600100023 targets are gamma-radioactive. The used target O172600100024 thicknesses are optimal for investigating products of O172600100025 relatively low yields and for the registration of the O172600100026 alpha-activity with satisfactory energy resolution. O172600100027 ADD-RES (COMP).Statistical model using the ALICE-MP code. O172600100028 STATUS (TABLE).Table data were received from Dr.A.A.Kulko O172600100029 (APRVD) Entry was approved by authors. O172600100030 HISTORY (20090216C) SB O172600100031 (20100713A).New reference was added. O172600100032 (20120614A) SD: DATA blocks were replaced by author's O172600100033 data in Subents 5 and 6. Cosmetic changes in Sub. 2-12.O172600100034 (20140205U) SD: Ref. on JP/CS,420 was added O172600100035 (20181104U) SD: Ref. FCY/L,6,342 was added. O172600100036 ENDBIB 34 0 O172600100037 NOCOMMON 0 0 O172600100038 ENDSUBENT 37 0 O172600199999 SUBENT O1726002 20120614 O048O172600200001 BIB 7 12 O172600200002 REACTION (83-BI-209(3-LI-6,3N)86-RN-212,,SIG) O172600200003 RAD-DET (86-RN-212,A) O172600200004 DECAY-DATA (86-RN-212,24.MIN,A,6300.) O172600200005 SAMPLE The Bi targets were about 700 mug/cm**2 thick and were O172600200006 produced by evaporation in vacuum of natural Bi on O172600200007 a 5 mum thick aluminum foil.The target thickness was O172600200008 enough to completely stop the heavy reaction products. O172600200009 DETECTOR (SOLST) A semiconductor detector measuring O172600200010 alpha activity. O172600200011 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600200012 (EN-ERR).The errors is reported by authors. O172600200013 STATUS (TABLE).Data corresponds to fig. 3 of JP/G,36,025104 O172600200014 ENDBIB 12 0 O172600200015 NOCOMMON 0 0 O172600200016 DATA 4 6 O172600200017 EN EN-ERR DATA DATA-ERR O172600200018 MEV MEV MB MB O172600200019 39.7 0.5 100. 4.3 O172600200020 34.6 0.6 121. 5.1 O172600200021 28.9 0.6 2.7 0.3 O172600200022 28. 0.7 2.9 0.3 O172600200023 27. 0.8 1.0 0.2 O172600200024 25.9 0.9 0.5 0.1 O172600200025 ENDDATA 8 0 O172600200026 ENDSUBENT 25 0 O172600299999 SUBENT O1726003 20120614 O048O172600300001 BIB 9 22 O172600300002 REACTION (83-BI-209(3-LI-6,4N)86-RN-211,,SIG) O172600300003 RAD-DET (86-RN-211,A) O172600300004 (85-AT-211,A) O172600300005 DECAY-DATA (86-RN-211,14.6HR,A,5800.) O172600300006 (85-AT-211,7.2HR,A,5870.) O172600300007 SAMPLE The Bi targets were about 700 mug/cm**2 thick and were O172600300008 produced by evaporation in vacuum of natural Bi on O172600300009 a 5 mum thick aluminum foil.The target thickness was O172600300010 enough to completely stop the heavy reaction products. O172600300011 DETECTOR A semiconductor detector measuring alpha activity. O172600300012 COMMENT *By authors*.The yields necessary for calculating the O172600300013 production cross sections of Rn-211 and At-211 were O172600300014 determined using the difference in their half-lives in O172600300015 the decomposition of the experimental decay curves. O172600300016 It was found that the formation of At-211 as the O172600300017 daughter of Rn-211 is more preferable than through the O172600300018 alpha-transfer from Li-6 channel. O172600300019 ANALYSIS (DECAY) O172600300020 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600300021 by authors. O172600300022 (EN-ERR).The errors is reported by authors. O172600300023 STATUS (TABLE).Data corresponds to fig. 3 of JP/G,36,025104 O172600300024 ENDBIB 22 0 O172600300025 NOCOMMON 0 0 O172600300026 DATA 4 5 O172600300027 EN EN-ERR DATA DATA-ERR O172600300028 MEV MEV MB MB O172600300029 52.6 0.4 198. 8.2 O172600300030 48.6 0.5 374. 15.1 O172600300031 44.3 0.5 477. 14.3 O172600300032 39.7 0.5 257. 9.8 O172600300033 34.6 0.6 44.1 2.3 O172600300034 ENDDATA 7 0 O172600300035 ENDSUBENT 34 0 O172600399999 SUBENT O1726004 20120614 O048O172600400001 BIB 7 12 O172600400002 REACTION (83-BI-209(3-LI-6,5N)86-RN-210,,SIG) O172600400003 RAD-DET (86-RN-210,A) O172600400004 DECAY-DATA (86-RN-210,2.4HR,A,6000.) O172600400005 SAMPLE The Bi targets were about 700 mug/cm**2 thick and were O172600400006 produced by evaporation in vacuum of natural Bi on O172600400007 a 5 mum thick aluminum foil.The target thickness was O172600400008 enough to completely stop the heavy reaction products. O172600400009 DETECTOR A semiconductor detector measuring alpha activity. O172600400010 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600400011 by authors. O172600400012 (EN-ERR).The errors is reported by authors. O172600400013 STATUS (TABLE).Data corresponds to fig. 3 of JP/G,36,025104 O172600400014 ENDBIB 12 0 O172600400015 NOCOMMON 0 0 O172600400016 DATA 4 4 O172600400017 EN EN-ERR DATA DATA-ERR O172600400018 MEV MEV MB MB O172600400019 56.3 0.4 924. 20.6 O172600400020 52.6 0.4 726. 21.5 O172600400021 48.6 0.5 528. 19.6 O172600400022 44.3 0.5 89.6 3.8 O172600400023 ENDDATA 6 0 O172600400024 ENDSUBENT 23 0 O172600499999 SUBENT O1726005 20120614 O048O172600500001 BIB 9 19 O172600500002 REACTION (83-BI-209(3-LI-6,X)84-PO-208,,SIG) O172600500003 RAD-DET (84-PO-208,A) O172600500004 DECAY-DATA (84-PO-208,2.9YR,A,5110.) O172600500005 SAMPLE The Bi targets were about 700 mug/cm**2 thick and were O172600500006 produced by evaporation in vacuum of natural Bi on O172600500007 a 5 mum thick aluminum foil.The target thickness was O172600500008 enough to completely stop the heavy reaction products. O172600500009 DETECTOR A semiconductor detector measuring alpha activity. O172600500010 COMMENT *By authors*.The alpha-spectra, from which the yield ofO172600500011 Po-208 was determined, were measured after more than O172600500012 two half-life periods of Po-210, whose contribution toO172600500013 the spectra was then considerably lowered. O172600500014 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600500015 by authors. O172600500016 (EN-ERR).The errors is reported by authors. O172600500017 STATUS (TABLE).Data corresponds to fig.4 of JP/G,36,025104 O172600500018 Data received from Dr. V.Maslov O172600500019 HISTORY (20120614A) SD: DATA block was changed to data receivedO172600500020 from Dr. V.Maslov; MISC-COL (-ERR) deleted. O172600500021 ENDBIB 19 0 O172600500022 COMMON 1 3 O172600500023 EN-ERR O172600500024 MEV O172600500025 1.1 O172600500026 ENDCOMMON 3 0 O172600500027 DATA 3 20 O172600500028 EN-CM DATA DATA-ERR O172600500029 MEV MB MB O172600500030 57.3 908.8 93.4 O172600500031 53.5 593. 61.1 O172600500032 49.4 480.2 45.3 O172600500033 48.6 520. 52.8 O172600500034 46.3 418.4 41.9 O172600500035 45.1 417.5 40.7 O172600500036 44. 410. 43.6 O172600500037 41.6 404.6 40.2 O172600500038 40.4 372.9 35.1 O172600500039 39.2 400. 43. O172600500040 36.5 342.5 33.8 O172600500041 35.2 354.9 36.4 O172600500042 33.8 358.8 34.9 O172600500043 30.7 228.9 21.6 O172600500044 29.4 126. 10.7 O172600500045 28.5 119.7 11. O172600500046 27.4 86.6 5. O172600500047 26.3 48. 5.1 O172600500048 25.1 12.4 1.1 O172600500049 23.9 1.1 0.13 O172600500050 ENDDATA 22 0 O172600500051 ENDSUBENT 50 0 O172600599999 SUBENT O1726006 20120614 O048O172600600001 BIB 9 20 O172600600002 REACTION (83-BI-209(3-LI-6,X)84-PO-210,,SIG) O172600600003 RAD-DET (84-PO-210,A) O172600600004 DECAY-DATA (84-PO-210,138.D,A,5400.) O172600600005 SAMPLE The Bi targets were about 700 mug/cm**2 thick and were O172600600006 produced by evaporation in vacuum of natural Bi on O172600600007 a 5 mum thick aluminum foil.The target thickness was O172600600008 enough to completely stop the heavy reaction products. O172600600009 DETECTOR A semiconductor detector measuring alpha activity. O172600600010 COMMENT *By authors*.The counting rate due to Po-210 was O172600600011 measured a few times during several months following O172600600012 the irradiation. In this case, the contribution of O172600600013 Po-208 could be neglected because of its long half-lifeO172600600014 of 2.9 years. O172600600015 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600600016 by authors. O172600600017 (EN-ERR).The errors is reported by authors. O172600600018 STATUS (TABLE).Data corresponds to fig.4 of JP/G,36,025104 O172600600019 Data received from Dr. V.Maslov O172600600020 HISTORY (20120614A) SD: DATA block was changed to data receivedO172600600021 from Dr. V.Maslov; MISC-COL (-ERR) deleted. O172600600022 ENDBIB 20 0 O172600600023 COMMON 1 3 O172600600024 EN-ERR O172600600025 MEV O172600600026 1.1 O172600600027 ENDCOMMON 3 0 O172600600028 DATA 3 20 O172600600029 EN-CM DATA DATA-ERR O172600600030 MEV MB MB O172600600031 57.3 90.3 19.07 O172600600032 53.5 80.2 27.13 O172600600033 49.4 70.6 18.16 O172600600034 48.6 70.1 25.35 O172600600035 46.3 40.8 17.93 O172600600036 45.1 40.5 6.95 O172600600037 44. 45.3 15.15 O172600600038 41.6 40.6 10.4 O172600600039 40.4 30.1 8.79 O172600600040 39.2 40.3 9.31 O172600600041 36.5 48.4 12.7 O172600600042 35.2 60.7 23.41 O172600600043 33.8 60.4 18.16 O172600600044 30.7 30.1 6.89 O172600600045 29.4 34.9 10.59 O172600600046 28.5 30.4 12.76 O172600600047 27.4 10.8 3.14 O172600600048 26.3 10.7 3.31 O172600600049 25.1 9.8 2.94 O172600600050 23.9 5.5 1.65 O172600600051 ENDDATA 22 0 O172600600052 ENDSUBENT 51 0 O172600699999 SUBENT O1726007 20120614 O048O172600700001 BIB 9 32 O172600700002 REACTION (78-PT-0(3-LI-6,X)81-TL-200,,SIG) O172600700003 SAMPLE The targets were of natural platinum. The main O172600700004 contribution is expected to come from the isotopes- O172600700005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172600700006 For this reason,the calculations of the cross sections O172600700007 of the different channels had to be done accounting forO172600700008 the contribution of the different Pt isotopes accordingO172600700009 to their presence in natural platinum. O172600700010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172600700011 induced in the individual gold foils was measured O172600700012 off-line using four energy and efficiency-calibrated O172600700013 HPGe detectors (the efficiency was about 4-5% for O172600700014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172600700015 the gamma-transition at 1332 keV. O172600700016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172600700017 programme DEIMOS32 was used. O172600700018 COMMENT *By authors*.The experimental cross sections of the Tl O172600700019 isotopes, formed after the evaporation from the O172600700020 compound Tl isotopes of three to five neutrons, were O172600700021 calculated on the basis of the measured yields O172600700022 accounting for the relevant beam dose and time factors,O172600700023 the efficiency of the detectors, the absolute intensityO172600700024 of the gamma-transitions and the target thickness. O172600700025 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172600700026 The induced gamma-ray activity in the Al degraders O172600700027 used in the Pt stack served also to monitor the beam O172600700028 dose via the cross section for production of Na-24. O172600700029 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172600700030 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600700031 by authors. O172600700032 (EN-ERR).The errors is reported by authors. O172600700033 STATUS (TABLE).Data corresponds to fig. 5 of JP/G,36,025104 O172600700034 ENDBIB 32 0 O172600700035 NOCOMMON 0 0 O172600700036 DATA 5 5 O172600700037 EN EN-ERR DATA-MAX DATA DATA-ERR O172600700038 MEV MEV MB MB MB O172600700039 41.46 0.86 21.70 0.525 O172600700040 37.84 0.91 28.75 2.074 O172600700041 33.97 0.97 20.84 1.355 O172600700042 29.93 1.03 3.98 0.436 O172600700043 26.33 1.12 0.083 O172600700044 ENDDATA 7 0 O172600700045 ENDSUBENT 44 0 O172600799999 SUBENT O1726008 20120614 O048O172600800001 BIB 9 32 O172600800002 REACTION (78-PT-0(3-LI-6,X)81-TL-199,,SIG) O172600800003 SAMPLE The targets were of natural platinum. The main O172600800004 contribution is expected to come from the isotopes- O172600800005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172600800006 For this reason,the calculations of the cross sections O172600800007 of the different channels had to be done accounting forO172600800008 the contribution of the different Pt isotopes accordingO172600800009 to their presence in natural platinum. O172600800010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172600800011 induced in the individual gold foils was measured O172600800012 off-line using four energy and efficiency-calibrated O172600800013 HPGe detectors (the efficiency was about 4-5% for O172600800014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172600800015 the gamma-transition at 1332 keV. O172600800016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172600800017 programme DEIMOS32 was used. O172600800018 COMMENT *By authors*.The experimental cross sections of the Tl O172600800019 isotopes, formed after the evaporation from the O172600800020 compound Tl isotopes of three to five neutrons, were O172600800021 calculated on the basis of the measured yields O172600800022 accounting for the relevant beam dose and time factors,O172600800023 the efficiency of the detectors, the absolute intensityO172600800024 of the gamma-transitions and the target thickness. O172600800025 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172600800026 The induced gamma-ray activity in the Al degraders O172600800027 used in the Pt stack served also to monitor the beam O172600800028 dose via the cross section for production of Na-24. O172600800029 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172600800030 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600800031 by authors. O172600800032 (EN-ERR).The errors is reported by authors. O172600800033 STATUS (TABLE).Data corresponds to fig. 6 of JP/G,36,025104 O172600800034 ENDBIB 32 0 O172600800035 NOCOMMON 0 0 O172600800036 DATA 5 5 O172600800037 EN EN-ERR DATA-MAX DATA DATA-ERR O172600800038 MEV MEV MB MB MB O172600800039 41.46 0.86 58.3 7.83 O172600800040 37.84 0.91 32. 7.20 O172600800041 33.97 0.97 20.8 3.33 O172600800042 29.93 1.03 14.7 6.0 O172600800043 26.33 1.12 1.35 O172600800044 ENDDATA 7 0 O172600800045 ENDSUBENT 44 0 O172600899999 SUBENT O1726009 20120614 O048O172600900001 BIB 9 32 O172600900002 REACTION (78-PT-0(3-LI-6,X)81-TL-198,,SIG) O172600900003 SAMPLE The targets were of natural platinum. The main O172600900004 contribution is expected to come from the isotopes- O172600900005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172600900006 For this reason,the calculations of the cross sections O172600900007 of the different channels had to be done accounting forO172600900008 the contribution of the different Pt isotopes accordingO172600900009 to their presence in natural platinum. O172600900010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172600900011 induced in the individual gold foils was measured O172600900012 off-line using four energy and efficiency-calibrated O172600900013 HPGe detectors (the efficiency was about 4-5% for O172600900014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172600900015 the gamma-transition at 1332 keV. O172600900016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172600900017 programme DEIMOS32 was used. O172600900018 COMMENT *By authors*.The experimental cross sections of the Tl O172600900019 isotopes, formed after the evaporation from the O172600900020 compound Tl isotopes of three to five neutrons, were O172600900021 calculated on the basis of the measured yields O172600900022 accounting for the relevant beam dose and time factors,O172600900023 the efficiency of the detectors, the absolute intensityO172600900024 of the gamma-transitions and the target thickness. O172600900025 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172600900026 The induced gamma-ray activity in the Al degraders O172600900027 used in the Pt stack served also to monitor the beam O172600900028 dose via the cross section for production of Na-24. O172600900029 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172600900030 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172600900031 by authors. O172600900032 (EN-ERR).The errors is reported by authors. O172600900033 STATUS (TABLE).Data corresponds to fig. 6 of JP/G,36,025104 O172600900034 ENDBIB 32 0 O172600900035 NOCOMMON 0 0 O172600900036 DATA 4 4 O172600900037 EN EN-ERR DATA DATA-ERR O172600900038 MEV MEV MB MB O172600900039 41.46 0.86 158. 11.5 O172600900040 37.84 0.91 158.7 24.3 O172600900041 33.97 0.97 102.5 6.0 O172600900042 29.93 1.03 18.3 8.3 O172600900043 ENDDATA 6 0 O172600900044 ENDSUBENT 43 0 O172600999999 SUBENT O1726010 20120614 O048O172601000001 BIB 9 32 O172601000002 REACTION (78-PT-0(3-LI-6,X)81-TL-197,,SIG) O172601000003 SAMPLE The targets were of natural platinum. The main O172601000004 contribution is expected to come from the isotopes- O172601000005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172601000006 For this reason,the calculations of the cross sections O172601000007 of the different channels had to be done accounting forO172601000008 the contribution of the different Pt isotopes accordingO172601000009 to their presence in natural platinum. O172601000010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172601000011 induced in the individual gold foils was measured O172601000012 off-line using four energy and efficiency-calibrated O172601000013 HPGe detectors (the efficiency was about 4-5% for O172601000014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172601000015 the gamma-transition at 1332 keV. O172601000016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172601000017 programme DEIMOS32 was used. O172601000018 COMMENT *By authors*.The experimental cross sections of the Tl O172601000019 isotopes, formed after the evaporation from the O172601000020 compound Tl isotopes of three to five neutrons, were O172601000021 calculated on the basis of the measured yields O172601000022 accounting for the relevant beam dose and time factors,O172601000023 the efficiency of the detectors, the absolute intensityO172601000024 of the gamma-transitions and the target thickness. O172601000025 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172601000026 The induced gamma-ray activity in the Al degraders O172601000027 used in the Pt stack served also to monitor the beam O172601000028 dose via the cross section for production of Na-24. O172601000029 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172601000030 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172601000031 by authors. O172601000032 (EN-ERR).The errors is reported by authors. O172601000033 STATUS (TABLE).Data corresponds to fig. 6 of JP/G,36,025104 O172601000034 ENDBIB 32 0 O172601000035 NOCOMMON 0 0 O172601000036 DATA 4 4 O172601000037 EN EN-ERR DATA DATA-ERR O172601000038 MEV MEV MB MB O172601000039 41.46 0.86 400. 27. O172601000040 37.84 0.91 356. 77. O172601000041 33.97 0.97 191. 34. O172601000042 29.93 1.03 19.2 4.2 O172601000043 ENDDATA 6 0 O172601000044 ENDSUBENT 43 0 O172601099999 SUBENT O1726011 20120614 O048O172601100001 BIB 9 32 O172601100002 REACTION (78-PT-0(3-LI-6,X)81-TL-196,,SIG) O172601100003 SAMPLE The targets were of natural platinum. The main O172601100004 contribution is expected to come from the isotopes- O172601100005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172601100006 For this reason,the calculations of the cross sections O172601100007 of the different channels had to be done accounting forO172601100008 the contribution of the different Pt isotopes accordingO172601100009 to their presence in natural platinum. O172601100010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172601100011 induced in the individual gold foils was measured O172601100012 off-line using four energy and efficiency-calibrated O172601100013 HPGe detectors (the efficiency was about 4-5% for O172601100014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172601100015 the gamma-transition at 1332 keV. O172601100016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172601100017 programme DEIMOS32 was used. O172601100018 COMMENT *By authors*.The experimental cross sections of the Tl O172601100019 isotopes, formed after the evaporation from the O172601100020 compound Tl isotopes of three to five neutrons, were O172601100021 calculated on the basis of the measured yields O172601100022 accounting for the relevant beam dose and time factors,O172601100023 the efficiency of the detectors, the absolute intensityO172601100024 of the gamma-transitions and the target thickness. O172601100025 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172601100026 The induced gamma-ray activity in the Al degraders O172601100027 used in the Pt stack served also to monitor the beam O172601100028 dose via the cross section for production of Na-24. O172601100029 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172601100030 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172601100031 by authors. O172601100032 (EN-ERR).The errors is reported by authors. O172601100033 STATUS (TABLE).Data corresponds to fig. 6 of JP/G,36,025104 O172601100034 ENDBIB 32 0 O172601100035 NOCOMMON 0 0 O172601100036 DATA 4 3 O172601100037 EN EN-ERR DATA DATA-ERR O172601100038 MEV MEV MB MB O172601100039 41.46 0.86 665. 69. O172601100040 37.84 0.91 354. 71. O172601100041 33.97 0.97 56. 11. O172601100042 ENDDATA 5 0 O172601100043 ENDSUBENT 42 0 O172601199999 SUBENT O1726012 20120614 O048O172601200001 BIB 10 37 O172601200002 REACTION (78-PT-0(3-LI-6,X)79-AU-199,,SIG) O172601200003 SAMPLE The targets were of natural platinum. The main O172601200004 contribution is expected to come from the isotopes- O172601200005 Pt-194 33%, Pt-195 33.8%, Pt-196 25.3%, Pt-198 7.2%. O172601200006 For this reason,the calculations of the cross sections O172601200007 of the different channels had to be done accounting forO172601200008 the contribution of the different Pt isotopes accordingO172601200009 to their presence in natural platinum. O172601200010 DETECTOR (HPGE) After the irradiation, the gamma-activity O172601200011 induced in the individual gold foils was measured O172601200012 off-line using four energy and efficiency-calibrated O172601200013 HPGe detectors (the efficiency was about 4-5% for O172601200014 E(g)= 662 keV) of high-energy resolution (1.2 keV for O172601200015 the gamma-transition at 1332 keV. O172601200016 ADD-RES (G-SPC).For the analysis of the gamma-spectra the O172601200017 programme DEIMOS32 was used. O172601200018 COMMENT *By authors*.The experimental cross sections of the Tl O172601200019 isotopes, formed after the evaporation from the O172601200020 compound Tl isotopes of three to five neutrons, were O172601200021 calculated on the basis of the measured yields O172601200022 accounting for the relevant beam dose and time factors,O172601200023 the efficiency of the detectors, the absolute intensityO172601200024 of the gamma-transitions and the target thickness. O172601200025 *By compiler*. En/Bc in Data section was multiplied by O172601200026 by compiler on the Coulomb barrier equal Bc=29.6 MeV. O172601200027 MONITOR (13-AL-27(3-LI-6,X)11-NA-24,,SIG) O172601200028 The induced gamma-ray activity in the Al degraders O172601200029 used in the Pt stack served also to monitor the beam O172601200030 dose via the cross section for production of Na-24. O172601200031 MONIT-REF (C0347001,I.M.Ladenbauer+,J,PR,123,1368,1961) O172601200032 ERR-ANALYS (DATA-ERR).The errors is reported by authors. O172601200033 by authors. O172601200034 (EN-ERR).The errors is reported by authors. O172601200035 STATUS (TABLE).Data corresponds to fig. 7 of JP/G,36,025104 O172601200036 MISC-COL (MISC).E(cm)/Bc is reported by authors in table for O172601200037 fig.7 O172601200038 (MISC-ERR).'MISC' uncertainty. O172601200039 ENDBIB 37 0 O172601200040 NOCOMMON 0 0 O172601200041 DATA 7 6 O172601200042 EN EN-ERR DATA-MAX DATA DATA-ERR MISC O172601200043 MISC-ERR O172601200044 MEV MEV MB MB MB SEE TEXT O172601200045 SEE TEXT O172601200046 37.60000 0.85840 185.00000 43.00000 1.27000O172601200047 0.02900 O172601200048 34.00000 0.91760 201.00000 37.00000 1.15000O172601200049 0.03100 O172601200050 30.20000 0.97680 222.00000 21.00000 1.02000O172601200051 0.03300 O172601200052 26.30000 1.03600 146.00000 14.00000 0.89000O172601200053 0.03500 O172601200054 22.80000 1.12480 63.00000 15.00000 0.77000O172601200055 0.03800 O172601200056 21.90000 1.21360 7.00000 0.74000O172601200057 0.04100 O172601200058 ENDDATA 16 0 O172601200059 ENDSUBENT 58 0 O172601299999 ENDENTRY 12 0 O172699999999