ENTRY O1705 20120614 O048O170500000001 SUBENT O1705001 20120614 O048O170500100001 BIB 13 51 O170500100002 TITLE Study of N=16 for Ne isotopes. O170500100003 AUTHOR (A.Gillibert,A.Obertelli,N.Alamanos,M.Alvarez, O170500100004 F.Auger,R.Dayras,A.Drouart,G.de France,B.Jurado, O170500100005 N.Keeley,V.Lapoux,W.Mittig,X.Mougeot,L.Nalpas,A.Pakou, O170500100006 N.Patronis,E.C.Pollacco,F.Rejmund,M.Rejmund, O170500100007 P.Roussel-Chomaz, H.Savajols, F.Skaza, Ch.Theisen) O170500100008 INSTITUTE (2FR SAC) O170500100009 (2FR GAN) O170500100010 (2GRCIOA) O170500100011 REFERENCE (J,EPJ/ST,150,161,2007) O170500100012 (J,PL/B,633,33,2006) Preliminary results O170500100013 FACILITY (CYCLO,2FR GAN) O170500100014 INC-SOURCE The Ne-26 beam was produced by the ISOL technique O170500100015 and accelerated to 9.7A MeV by the CIME cyclotron at O170500100016 the SPIRAL facility.A S-36 primary beam at 77.5A*MeV O170500100017 was fragmented and stopped in a thick carbon target. O170500100018 METHOD (EDE,TOF) O170500100019 (COINC) O170500100020 (EXTB) O170500100021 SAMPLE A solid cryogenic D(2) target, thickness 17 mg/cm**2, O170500100022 was used. O170500100023 DETECTOR (MAGSP) the VAMOS magnetic spectrometer, allowing an O170500100024 identification of ejectiles and a counting rate O170500100025 measurement of reaction products and Ne-26 beam O170500100026 particles. O170500100027 (SPEC) Photons were measured in the EXOGAM O170500100028 spectrometer. The intrinsic energy resolution of the O170500100029 whole system was measured to be 2.6 keV(FWHM) at O170500100030 1332 keV and the corresponding photo-peak efficiency O170500100031 was estimated to be 4.8%. O170500100032 (MCPLT) O170500100033 (IOCH) O170500100034 (SCIN) O170500100035 To identify Ne-27 beam-like ejectiles in the focal O170500100036 plane of VAMOS, was used combinations of following O170500100037 parameters: O170500100038 -the time of flight(TOF) between a microchannel plate O170500100039 device before the target and the plastic scintillator O170500100040 VAMOS, O170500100041 -the energy loss delta-E in the ionization chamber of O170500100042 VAMOS, O170500100043 -the horizontal position X on the focal plane of O170500100044 VAMOS measured by two drift chambers. O170500100045 REL-REF (I,,H.Savajols+,J,NP/A,654,1027C,1999) - description O170500100046 of VAMOS magnetic spectrometer O170500100047 ERR-ANALYS (DATA-ERR).The quoted uncertainties are mainly due to O170500100048 statistical error and a 10% uncertainty over the O170500100049 absolute photopeak efficiencies of EXOGAM. O170500100050 STATUS (TABLE) Table 1 from EPJ/ST,150,161,2007 O170500100051 HISTORY (20081121C) SB O170500100052 (20120614U) SD: Title and author's name corrected. O170500100053 ENDBIB 51 0 O170500100054 COMMON 1 3 O170500100055 EN O170500100056 MEV/A O170500100057 9.7 O170500100058 ENDCOMMON 3 0 O170500100059 ENDSUBENT 58 0 O170500199999 SUBENT O1705002 20081121 O038O170500200001 BIB 2 2 O170500200002 REACTION (1-H-2(10-NE-26,P)10-NE-27,PAR,SIG) O170500200003 EN-SEC (E-LVL,10-NE-27) O170500200004 ENDBIB 2 0 O170500200005 NOCOMMON 0 0 O170500200006 DATA 3 3 O170500200007 E-LVL DATA DATA-ERR O170500200008 MEV MB MB O170500200009 0.000 4.6 3.9 O170500200010 0.765 21.3 2.3 O170500200011 0.885 3.1 0.6 O170500200012 ENDDATA 5 0 O170500200013 ENDSUBENT 12 0 O170500299999 ENDENTRY 2 0 O170599999999