ENTRY O1693 20180305 O064O169300000001 SUBENT O1693001 20180305 O064O169300100001 BIB 10 31 O169300100002 TITLE Precision study of ground state capture in the O169300100003 14N(p,g)15O reaction O169300100004 AUTHOR (M.Marta, A.Formicola, Gy.Gyuerky, D.Bemmerer, O169300100005 C.Broggini, A.Caciolli, P.Corvisiero, H.Costantini, O169300100006 Z.Elekes, Zs.Fuelop, G.Gervino, A.Guglielmetti, O169300100007 C.Gustavino, G.Imbriani, M.Junker, R.Kunz, A.Lemut, O169300100008 B.Limata, C.Mazzocchi, R.Menegazzo, P.Prati, O169300100009 V.Roca, C.Rolfs, M.Romano, C.Rossi Alvarez, O169300100010 E.Somorjai, O.Straniero, F.Strieder, F.Terrasi, O169300100011 H.P.Trautvetter, A.Vomiero) O169300100012 INSTITUTE (2GERZFK,2ITYLGS,3HUNDEB,2ITYUPV,2ITYGVA,2ITYTUR, O169300100013 2ITYMIL,2ITYNAP,2GERBOC,2ITYOAC,2ITYFSN,2ITYPAD) OO169300100014 REFERENCE (J,PR/C,78,022802,2008) O169300100015 FACILITY (ACCEL,2ITYLGS) The 400 kV LUNA accelerator O169300100016 SAMPLE A sputtered TiN target with 55 keV thickness, was used.O169300100017 DETECTOR (BGO).The gamma-rays from the reaction to be studied O169300100018 were detected in a Eurisys Clover-BGO detection system.O169300100019 The front end of the Clover crystals was positioned O169300100020 at 9.5 cm distance from the target, at an angle of 55 O169300100021 degree with respect to the beam axis. O169300100022 The gamma-ray detection efficiency was obtained using O169300100023 Cs-137 and CO-60 radioactive sources calibrated to 1.5 O169300100024 and 0.75%, respectively. O169300100025 METHOD (SITA) O169300100026 COMMENT *By authors*.The effective energy E was determined fromO169300100027 the centroids of the gamma lines for capture to the O169300100028 ground state and to the 6792 keV state and leads to O169300100029 2.0-2.4% uncertainty. O169300100030 HISTORY (20081106C) S.B O169300100031 (20180305D) MPT+On. 003 deleted(=O1912.003). O169300100032 (20180305A) MPT+On. 002 Superseded. O169300100033 ENDBIB 31 0 O169300100034 NOCOMMON 0 0 O169300100035 ENDSUBENT 34 0 O169300199999 SUBENT O1693002 20180305 O064O169300200001 BIB 5 23 O169300200002 REACTION 1((7-N-14(P,G)8-O-15,PAR,SIG)// O169300200003 (7-N-14(P,G)8-O-15,PAR,SIG)) O169300200004 Singles mode (signals from 4 Clover summed offline) O169300200005 2((7-N-14(P,G)8-O-15,PAR,SIG)// O169300200006 (7-N-14(P,G)8-O-15,PAR,SIG)) Addback mode O169300200007 Addback mode (signals from 4 Clover summed online) O169300200008 MISC-COL (MISC) Summing in correction. O169300200009 ERR-ANALYS (EN-ERR).The error in effective energy. O169300200010 (ERR-SYS).The systematics uncertainty depends on O169300200011 -the summing -in correction for the ground state O169300200012 gamma-ray, O169300200013 -the slope of the detection efficiency curve, O169300200014 -the anticoincidence efficiency, O169300200015 -the summing-out correction contribute to the O169300200016 systematic uncertainty. O169300200017 The effects of target composition and profile, stoppingO169300200018 power, beam intensity and absolute gamma-ray detection O169300200019 efficiency cancel out in the relative experiment. O169300200020 (ERR-S).The errors due to statistics-activity O169300200021 measurements. O169300200022 STATUS (TABLE) Table 2 of Phys.Rev.C78(2008)022802 O169300200023 (SPSDD,O1912002) O169300200024 HISTORY (20180305A) MPT+On. Superseded. O169300200025 ENDBIB 23 0 O169300200026 COMMON 3 3 O169300200027 E-LVL-NM E-LVL-DN EN-ERR O169300200028 EV MEV KEV O169300200029 0.000 6.792 1.5 O169300200030 ENDCOMMON 3 0 O169300200031 DATA 9 3 O169300200032 EN-CM DATA 1ERR-S 1ERR-SYS 1MISC 1DATA 2O169300200033 ERR-S 2ERR-SYS 2MISC 2 O169300200034 KEV NO-DIM PER-CENT PER-CENT PER-CENT NO-DIM O169300200035 PER-CENT PER-CENT PER-CENT O169300200036 317.8 0.0471 5.9 5.4 30. 0.0467 O169300200037 14. 2.7 4.3 O169300200038 334.4 0.0500 5.1 3.9 21. 0.0507 O169300200039 13. 2.5 3.4 O169300200040 353.3 0.0530 3.6 3.5 19. 0.0515 O169300200041 10. 2.3 3.2 O169300200042 ENDDATA 10 0 O169300200043 ENDSUBENT 42 0 O169300299999 NOSUBENT O1693003 20180305 O064O169300300001 ENDENTRY 3 0 O169399999999