ENTRY O1375 20201021 O081O137500000001 SUBENT O1375001 20201021 O081O137500100001 BIB 12 26 O137500100002 TITLE The sub-Coulomb Au-197(t,d)Au-198 reaction. O137500100003 AUTHOR (M.H.Thoma, E.Huenges, H.Morinaga, M.Igarashi, K.Ogawa)O137500100004 INSTITUTE (2GERMUN) O137500100005 (2JPNTOK) O137500100006 REFERENCE (J,ZP/A,334,293,1989) O137500100007 FACILITY (VDGT,2GERMUU) The MP-tandem. O137500100008 SAMPLE The packed of gold foils, a thickness of about O137500100009 6-mg/cm**2, were used. The energy loss of the tritons O137500100010 in each foil is about 300-keV. O137500100011 DETECTOR (GELI) O137500100012 METHOD (STTA) See SAMPLE. O137500100013 (EXTB) The current was limited to about 1 uA in order O137500100014 to prevent the melting of the foils. O137500100015 (ACTIV) The radiations were continued over about 24 O137500100016 hours. O137500100017 (GSPEC) O137500100018 COMMENT -By authors. The different absolute value of the cross O137500100019 sections are caused by difficulties in measuring the O137500100020 exact value of the current on the target and by O137500100021 different (n,gamma)-yields. O137500100022 ADD-RES (COMP) DWBA calculation. O137500100023 STATUS (CURVE) Fig.1 from Zeitschr.Phys.,A334(1989)293 O137500100024 HISTORY (20060408C) .By CAJAD. O137500100025 (20060503A) Correction. O137500100026 (20060503U) Last checking has been done. O137500100027 (20201021A) SD: Corrections in Subent 002. O137500100028 ENDBIB 26 0 O137500100029 NOCOMMON 0 0 O137500100030 ENDSUBENT 29 0 O137500199999 SUBENT O1375002 20201021 O081O137500200001 BIB 6 17 O137500200002 REACTION (79-AU-197(T,X)79-AU-198,,SIG) O137500200003 FLAG (1.) A copper beam stop was used. O137500200004 (2.) A golden beam stop was used to reduce neutron O137500200005 background. O137500200006 DECAY-DATA (79-AU-198-G,2.964D,DG,412.,0.997) O137500200007 COMMENT -By author. The horizontal slope of the cross section O137500200008 at low energies is due to (n,gamma)-reaction induced byO137500200009 the neutron background during the irradiation. O137500200010 ERR-ANALYS (DATA-ERR) Cross section uncertainty arise from the O137500200011 uncertainties in determining the intensity of the O137500200012 gamma-line, the efficiency of the gamma-detector and O137500200013 the current on the target. O137500200014 (EN-ERR) Beam energy uncertainty arise from the O137500200015 inaccuracies in the knowledge of the thickness of gold O137500200016 foils and of the triton energy. O137500200017 HISTORY (20201021A) SD: SF3=D -> X in REACTION code. O137500200018 ERR-T -> DATA-ERR. O137500200019 ENDBIB 17 0 O137500200020 NOCOMMON 0 0 O137500200021 DATA 5 18 O137500200022 EN EN-ERR DATA DATA-ERR FLAG O137500200023 MEV MEV MICRO-B PER-CENT NO-DIM O137500200024 3.94 0.09 0.59 10. 2. O137500200025 4.27 0.09 0.61 8. 2. O137500200026 4.36 0.07 2.76 10. 1. O137500200027 4.61 0.07 0.59 8. 2. O137500200028 4.72 0.06 2.7 7. 1. O137500200029 4.9 0.13 0.75 9. 2. O137500200030 5.03 0.09 3.42 8. 1. O137500200031 5.28 0.09 1.78 10. 2. O137500200032 5.37 0.1 5.3 8. 1. O137500200033 5.68 0.09 11.8 8. 1. O137500200034 5.82 0.09 8.4 8. 2. O137500200035 6.02 0.1 25.6 8. 1. O137500200036 6.29 0.09 64. 9. 1. O137500200037 6.47 0.08 51. 8. 2. O137500200038 6.58 0.09 128. 13. 1. O137500200039 6.85 0.08 262. 10. 1. O137500200040 7.03 0.09 256. 10. 2. O137500200041 7.12 0.07 510. 12. 1. O137500200042 ENDDATA 20 0 O137500200043 ENDSUBENT 42 0 O137500299999 ENDENTRY 2 0 O137599999999