ENTRY O1335 20190419 O068O133500000001 SUBENT O1335001 20190419 O068O133500100001 BIB 12 36 O133500100002 TITLE Heavy fragment energies and angular distributions O133500100003 in the reaction of 86-MeV/nuclon C-12 with medium-A O133500100004 targets. O133500100005 AUTHOR (A.Lleres, J.Blachot, J.Crancon, A.Gizon, O133500100006 H.Nifenecker) O133500100007 INSTITUTE (2FR GRE) O133500100008 (2FR FR) Institute of Nuclear Science, Grenoble. O133500100009 REFERENCE (J,ZP/A,312,177,1983) O133500100010 ADD-RES (COMP) Intranuclear cascade plus evaporation O133500100011 calculations. O133500100012 (RANGE) Projected ranges, relative to the beam axis, O133500100013 has been measured using the thin target-thin catchers O133500100014 technique. O133500100015 DETECTOR (GELI) Four geometrically calibrated Ge(Li) detectors O133500100016 have been used for the gamma-activity measurements. O133500100017 FACILITY (SYNCY,2ZZZCER) K=800 synchrocyclotron at CERN. O133500100018 SAMPLE For all experiments self-supporting Al-catchers and O133500100019 metallic targets have been prepared by the classical O133500100020 vacuum evaporation technique. O133500100021 MONITOR ((MONIT1)13-AL-27(6-C-12,X)11-NA-24,CUM,SIG) O133500100022 ((MONIT2)13-AL-27(6-C-12,X)11-NA-22,CUM,SIG) O133500100023 It is values were reported by J.W.N.Tuyn+ in technicalO133500100024 Memorandum HS-RP/TU/80-5,CERN(1980). O133500100025 METHOD (REC) O133500100026 (CHSEP) To concentrate activities on small area. O133500100027 (GSPEC) The measurements were started ~5 hours after O133500100028 end of irradiations. The samples were assayed for two O133500100029 or three weeks for medium half-lives activities and O133500100030 then regularly during two or three months for O133500100031 longer-lived isotopes. O133500100032 ERR-ANALYS (MONIT1-ERR) The uncertainty of MONIT1. O133500100033 (MONIT2-ERR) The uncertainty of MONIT2. O133500100034 HISTORY (20060331C) O133500100035 (20060529A) Correction, according to Ohtsuka N. O133500100036 (20060529U) Last checking has been done. O133500100037 (20190419U) SD: Small correction in Subent 003. O133500100038 ENDBIB 36 0 O133500100039 COMMON 5 3 O133500100040 EN MONIT1 MONIT2 MONIT1-ERR MONIT2-ERR O133500100041 MEV MB MB MB MB O133500100042 1032. 24.5 34.6 3. 5. O133500100043 ENDCOMMON 3 0 O133500100044 ENDSUBENT 43 0 O133500199999 SUBENT O1335002 20060529 O026O133500200001 BIB 5 14 O133500200002 REACTION (29-CU-0(6-C-12,X)ELEM/MASS,(CUM),SIG) O133500200003 COMMENT -By authors. The thick target between thick catchers O133500200004 technique has not been used for the natural Cu-target, O133500200005 nevertheless, summing partial cross sections in thin O133500200006 catchers and in target, an estimation of the total O133500200007 cross-section has been made. O133500200008 - By compiler. The authors did not distinguish O133500200009 cumulative and direct productons. O133500200010 SAMPLE A 1.5-mg/cm**2 thick target placed between two 20-mum O133500200011 thick aluminium catchers, able to stop all the productsO133500200012 recoiling from the irradiated sample. O133500200013 ERR-ANALYS (DATA-ERR) The uncertainty is given by authors in O133500200014 table. An analysis is not given. O133500200015 STATUS (TABLE) Table 1 in the paper. O133500200016 ENDBIB 14 0 O133500200017 NOCOMMON 0 0 O133500200018 DATA 4 12 O133500200019 ELEMENT MASS DATA DATA-ERR O133500200020 NO-DIM NO-DIM MB MB O133500200021 12. 28. 0.58 0.09 O133500200022 21. 44. 15.1 1.5 O133500200023 21. 46. 28. 2.8 O133500200024 21. 47. 5.65 0.85 O133500200025 23. 48. 25.4 2.5 O133500200026 24. 48. 0.78 0.12 O133500200027 24. 51. 100. 5. O133500200028 25. 52. 21.3 2.1 O133500200029 25. 54. 42.9 4.3 O133500200030 27. 56. 19.6 2. O133500200031 27. 57. 57. 5.7 O133500200032 27. 58. 50.2 5. O133500200033 ENDDATA 14 0 O133500200034 ENDSUBENT 33 0 O133500299999 SUBENT O1335003 20190419 O068O133500300001 BIB 7 14 O133500300002 REACTION (47-AG-0(6-C-12,X)MASS,CHN,SIG) O133500300003 REL-REF (R,,Y.Yariv+,J,PR/C,20,2227,1979) ISABELLA code O133500300004 (R,,L.Dostrovsky+,J,PR,116,683,1959) EVA code. O133500300005 SAMPLE A 1.5-mg/cm**2 thick target placed between two 20-mum O133500300006 thick aluminium catchers, able to stop all the productsO133500300007 recoiling from the irradiated sample. O133500300008 ERR-ANALYS (DATA-ERR) No information about source of uncertainty O133500300009 STATUS (CURVE) By CAJAD. Fig 9 from Z.Phys.,A312(1983)177 O133500300010 ADD-RES (COMP) ISABELLE and EVA codes. The mass-yield curve isO133500300011 Reasonably well reproduced by the theoretical approach O133500300012 for the high mass fragments but it exists a large O133500300013 discrepancy for the lightest residues. O133500300014 HISTORY (20190419A) SD: SF5=CHN added to REACTION code. O133500300015 Year of ref. in REL-REF corrected. O133500300016 ENDBIB 14 0 O133500300017 NOCOMMON 0 0 O133500300018 DATA 3 16 O133500300019 MASS DATA DATA-ERR O133500300020 NO-DIM MB PER-CENT O133500300021 47. 0.43 21. O133500300022 52. 0.48 19. O133500300023 59. 0.7 26. O133500300024 65. 4.8 15. O133500300025 74. 16.2 13. O133500300026 79. 30. 13. O133500300027 82. 32. 13. O133500300028 86. 39. 13. O133500300029 87. 41. 10. O133500300030 88. 36. 11. O133500300031 92. 41. 15. O133500300032 96. 49. 12. O133500300033 98. 41. 12. O133500300034 100. 55. 13. O133500300035 104. 79. 11. O133500300036 105. 64. 11. O133500300037 ENDDATA 18 0 O133500300038 ENDSUBENT 37 0 O133500399999 SUBENT O1335004 20060529 O026O133500400001 BIB 4 18 O133500400002 REACTION (50-SN-124(6-C-12,X)ELEM/MASS,,DA,,REL) Figures 5,6. O133500400003 SAMPLE For the angular distributions measurements, the thin O133500400004 target, 200-400-mg/cm**2 thickness, was placed at O133500400005 45-degree against the beam axis. The recoil nuclei wereO133500400006 stopped in angular 100-mum MYLAR catcher foils arrangedO133500400007 inside the chamber. In several angular distribution O133500400008 measurements, the 100-mum MYLAR foil was replaced by O133500400009 one MYLAR layers associated with an Al-layer to O133500400010 discriminate different kinetic energies at different O133500400011 angles for a given final product. In other experiments,O133500400012 at a mean of 30-degree, the 100-mum thick MYLAR O133500400013 collector has been replaced by a series of 3.5-mum O133500400014 thick MYLAR catchers able to give range estimations at O133500400015 a given angular domain. O133500400016 ERR-ANALYS (DATA-ERR) The uncertainty is given by authors on O133500400017 figure. An analysis is not given. O133500400018 (ANG-ERR-D) Digitizing error of angle. O133500400019 STATUS (CURVE) By CAJAD. O133500400020 ENDBIB 18 0 O133500400021 COMMON 1 3 O133500400022 ANG-ERR-D O133500400023 ADEG O133500400024 0.5 O133500400025 ENDCOMMON 3 0 O133500400026 DATA 5 51 O133500400027 ELEMENT MASS ANG DATA DATA-ERR O133500400028 NO-DIM NO-DIM ADEG ARB-UNITS PER-CENT O133500400029 39. 87. 4.2 4.92 O133500400030 39. 87. 10.9 4.8 O133500400031 39. 87. 28. 2.26 O133500400032 39. 87. 37. 1.434 O133500400033 39. 87. 43.5 1.181 O133500400034 39. 87. 51.3 0.73 O133500400035 39. 87. 63.4 0.358 O133500400036 39. 87. 77.7 0.1369 O133500400037 44. 97. 3.7 16.4 O133500400038 44. 97. 10.6 14.3 O133500400039 44. 97. 28.6 6.45 O133500400040 44. 97. 37.1 3.98 O133500400041 44. 97. 43.7 2.16 O133500400042 44. 97. 51.4 1.84 O133500400043 44. 97. 63.7 0.784 O133500400044 44. 97. 79. 0.303 O133500400045 45. 101. 3.5 31.7 O133500400046 45. 101. 10.3 29.7 O133500400047 45. 101. 28.5 12.24 O133500400048 45. 101. 36.4 7.9 O133500400049 45. 101. 43.4 4.72 O133500400050 45. 101. 50.8 3.7 O133500400051 45. 101. 62.5 1.78 O133500400052 45. 101. 78. 0.65 O133500400053 47. 105. 3.5 70.2 O133500400054 47. 105. 9.8 89.7 O133500400055 47. 105. 28.2 35.2 O133500400056 47. 105. 35.7 23.7 O133500400057 47. 105. 43.8 13.47 O133500400058 47. 105. 62.5 5.22 O133500400059 47. 105. 78.1 2.1 O133500400060 51. 120. 2. 0.6 7.3 O133500400061 51. 120. 9. 0.6 8.3 O133500400062 51. 120. 29. 0.1 5.4 O133500400063 51. 120. 35. 0.9 4.6 O133500400064 51. 120. 43. 0.4 3.6 O133500400065 51. 120. 51. 0.6 3.8 O133500400066 51. 120. 62. 0.9 2.2 O133500400067 51. 120. 77. 0.7 0.96 O133500400068 51. 120. 94. 0.1 0.25 O133500400069 51. 120. 110. 0.2 0.06 O133500400070 51. 122. 1.9 2.2 18. O133500400071 51. 122. 8.6 2. 15. O133500400072 51. 122. 27.5 1.7 18. O133500400073 51. 122. 35.3 1.52 14. O133500400074 51. 122. 42.4 1.3 20. O133500400075 51. 122. 50.3 0.94 16. O133500400076 51. 122. 62.1 0.83 17. O133500400077 51. 122. 76.9 0.35 14. O133500400078 51. 122. 94. 0.135 16. O133500400079 51. 122. 110. 0.043 26. O133500400080 ENDDATA 53 0 O133500400081 ENDSUBENT 80 0 O133500499999 SUBENT O1335005 20060529 O026O133500500001 BIB 4 17 O133500500002 REACTION (39-Y-89(6-C-12,X)ELEM/MASS,,DA,,REL) Figure 7-8 O133500500003 SAMPLE For the angular distributions measurements, the thin O133500500004 target, 200-400-mg/cm**2 thickness, was placed at O133500500005 45-degree against the beam axis. The recoil nuclei wereO133500500006 stopped in angular 100-mum mylar catcher foils arrangedO133500500007 inside the chamber. In several angular distribution O133500500008 measurements, the 100-mum mylar foil was replaced by O133500500009 one mylar layers associated with an Al-layer to O133500500010 discriminate different kinetic energies at different O133500500011 angles for a given final product. In other experiments,O133500500012 at a mean of 30-degree, the 100-mum thick mylar O133500500013 collector has been replaced by a series of 3.5-mum O133500500014 thick mylar catchers able to give range estimations at O133500500015 a given angular domain. O133500500016 ERR-ANALYS (ERR-DIG) Digitizing error of data. O133500500017 (ANG-ERR-D) Digitizing error of angle. O133500500018 STATUS (CURVE) By CAJAD. O133500500019 ENDBIB 17 0 O133500500020 COMMON 2 3 O133500500021 ANG-ERR-D ERR-DIG O133500500022 ADEG PER-CENT O133500500023 0.8 3. O133500500024 ENDCOMMON 3 0 O133500500025 DATA 4 48 O133500500026 ELEMENT MASS ANG DATA O133500500027 NO-DIM NO-DIM ADEG ARB-UNITS O133500500028 23. 48. 14.8 2.39 O133500500029 23. 48. 25.1 1.74 O133500500030 23. 48. 34.9 1.39 O133500500031 23. 48. 50.2 0.769 O133500500032 23. 48. 62.2 0.457 O133500500033 23. 48. 77. 0.207 O133500500034 23. 48. 110.5 0.0395 O133500500035 25. 52. 17. 0.8 O133500500036 25. 52. 27. 0.6 O133500500037 25. 52. 35. 0.3 O133500500038 25. 52. 51. 0.1 O133500500039 25. 52. 63. 0.6 O133500500040 25. 52. 76. 0.7 O133500500041 25. 52. 110. 0.5 O133500500042 27. 58. 8. 0.4 O133500500043 27. 58. 16. 0.1 O133500500044 27. 58. 26. 0.4 O133500500045 27. 58. 35. 0.1 O133500500046 27. 58. 50. 0.4 O133500500047 27. 58. 63. 0.5 O133500500048 27. 58. 77. 0.1 O133500500049 27. 58. 110. 0.9 O133500500050 33. 71. 6. 0.4 O133500500051 33. 71. 10. 0.2 O133500500052 33. 71. 17. 0.3 O133500500053 33. 71. 28. 0.2 O133500500054 33. 71. 35. 0.8 O133500500055 33. 71. 52. 0.6 O133500500056 33. 71. 64. 0.5 O133500500057 33. 71. 79. 0.7 O133500500058 33. 71. 111. 0.8 O133500500059 35. 77. 6.8 930. O133500500060 35. 77. 9.5 792. O133500500061 35. 77. 16. 646. O133500500062 35. 77. 26.3 367. O133500500063 35. 77. 34.9 313. O133500500064 35. 77. 50.1 124. O133500500065 35. 77. 77.8 10.5 O133500500066 35. 77. 108.7 0.891 O133500500067 38. 83. 12. 3520. O133500500068 38. 83. 13.6 2810. O133500500069 38. 83. 21.2 2630. O133500500070 38. 83. 31.9 1960. O133500500071 38. 83. 40.6 1750. O133500500072 38. 83. 54.5 1020. O133500500073 38. 83. 68. 620. O133500500074 38. 83. 81.8 251. O133500500075 38. 83. 113.1 28. O133500500076 ENDDATA 50 0 O133500500077 ENDSUBENT 76 0 O133500599999 SUBENT O1335006 20060529 O026O133500600001 BIB 4 18 O133500600002 REACTION (50-SN-112(6-C-12,X)23-V-48,,DA,,REL) Fig 8a O133500600003 SAMPLE For the angular distributions measurements, the thin O133500600004 target, 200-400-mg/cm**2 thickness, was placed at O133500600005 45-degree against the beam axis. The recoil nuclei wereO133500600006 stopped in angular 100-mum MYLAR catcher foils arrangedO133500600007 inside the chamber. In several angular distribution O133500600008 measurements, the 100-mum MYLAR foil was replaced by O133500600009 one mylar layers associated with an Al-layer to O133500600010 discriminate different kinetic energies at different O133500600011 angles for a given final product. In other experiments,O133500600012 at a mean of 30-degree, the 100-mum thick MYLAR O133500600013 collector has been replaced by a series of 3.5-mum O133500600014 thick MYLAR catchers able to give range estimations at O133500600015 a given angular domain. O133500600016 ERR-ANALYS (DATA-ERR) The uncertainty is reported by authors on O133500600017 figure O133500600018 (ANG-ERR-D) Data point reader uncertainty O133500600019 STATUS (CURVE) By CAJAD. O133500600020 ENDBIB 18 0 O133500600021 COMMON 1 3 O133500600022 ANG-ERR-D O133500600023 ADEG O133500600024 0.7 O133500600025 ENDCOMMON 3 0 O133500600026 DATA 3 14 O133500600027 ANG DATA DATA-ERR O133500600028 ADEG ARB-UNITS PER-CENT O133500600029 2.1 340. 18. O133500600030 3.9 182. 14. O133500600031 8.2 216. 16. O133500600032 9.5 122. 15. O133500600033 17.2 16.8 16. O133500600034 26.3 7.9 16. O133500600035 31.3 4.8 26. O133500600036 43.1 2.6 50. O133500600037 51.9 1.9 30. O133500600038 63.2 1.4 40. O133500600039 78.7 0.8 60. O133500600040 95.4 0.9 60. O133500600041 111.1 0.27 90. O133500600042 124.1 0.22 100. O133500600043 ENDDATA 16 0 O133500600044 ENDSUBENT 43 0 O133500699999 SUBENT O1335007 20060529 O026O133500700001 BIB 4 18 O133500700002 REACTION (50-SN-112(6-C-12,X)25-MN-52,,DA,,REL) Fig 8B O133500700003 SAMPLE For the angular distributions measurements, the thin O133500700004 target, 200-400-mg/cm**2 thickness, was placed at O133500700005 45-degree against the beam axis. The recoil nuclei wereO133500700006 stopped in angular 100-mum mylar catcher foils arrangedO133500700007 inside the chamber. In several angular distribution O133500700008 measurements, the 100-mum mylar foil was replaced by O133500700009 one mylar layers associated with an Al-layer to O133500700010 discriminate different kinetic energies at different O133500700011 angles for a given final product. In other experiments,O133500700012 at a mean of 30-degree, the 100-mum thick mylar O133500700013 collector has been replaced by a series of 3.5-mum O133500700014 thick mylar catchers able to give range estimations at O133500700015 a given angular domain. O133500700016 ERR-ANALYS (DATA-ERR) The uncertainty is reported by authors on O133500700017 figure O133500700018 (ANG-ERR-D) Digitizing error of angle. O133500700019 STATUS (CURVE) By CAJAD. O133500700020 ENDBIB 18 0 O133500700021 COMMON 1 3 O133500700022 ANG-ERR-D O133500700023 ADEG O133500700024 0.8 O133500700025 ENDCOMMON 3 0 O133500700026 DATA 3 8 O133500700027 ANG DATA DATA-ERR O133500700028 ADEG ARB-UNITS PER-CENT O133500700029 10.7 35. 26. O133500700030 17.8 35. 26. O133500700031 35.8 21. 30. O133500700032 42.9 26. 30. O133500700033 51.6 14. 40. O133500700034 63.5 9. 40. O133500700035 90.8 2.1 50. O133500700036 109.8 0.7 40. O133500700037 ENDDATA 10 0 O133500700038 ENDSUBENT 37 0 O133500799999 ENDENTRY 7 0 O133599999999