ENTRY O1323 20070607 O030O132300000001 SUBENT O1323001 20070607 O030O132300100001 BIB 10 42 O132300100002 TITLE Backbending region study in Dy-160,162 using incompleteO132300100003 fusion reactions. O132300100004 AUTHOR (A.Jungclaus, B.Binder, A.Dietrich, T.Haertlein, O132300100005 H.Bauer, Ch.Gund, D.Pansegrau, D.Schwalm, J.L.Egido, O132300100006 Y.Sun, D.Bazzacco, G.De Angelis, E.Farnea, A.Gadea, O132300100007 S.Lunardi, D.R.Napoli, C.Rossi-Alvarez, C.Ur, O132300100008 G.B.Hagemann) O132300100009 INSTITUTE (2SPNAUT) O132300100010 (2GERMPH) O132300100011 (1USATEN) O132300100012 (2ITYPAD) O132300100013 (2DENNBI) O132300100014 REFERENCE (J,PR/C,66,014312,2002) O132300100015 HISTORY (20070606C) S.B O132300100016 (20070607U) Last checking has been done. O132300100017 DETECTOR (SPEC) The gamma-ray were detected in the GASP- O132300100018 spectrometer in coincidence with fast charged particlesO132300100019 detected in the ISIS-silicon ball. O132300100020 ADD-RES (COMP).The projected shell model. O132300100021 The experimental interaction strengths are determined. O132300100022 COMMENT *By authors*.Two complementary experiments were O132300100023 performed.The first experiment was to measure absolute O132300100024 cross sections. The reaction mechanism-relative cross O132300100025 sections were deduced by measuring the total gamma-fluxO132300100026 into the ground states of different nuclei in the O132300100027 gamma-gamma coincidence data. The intensities of all O132300100028 gamma-transitions have been corrected for the energy O132300100029 dependent efficiency of the detectors and internal O132300100030 conversion. To determine absolute cross sections from O132300100031 relative ones, the intensities of the X-rays from the O132300100032 Gd-target observed in a Ge-detector within absorber O132300100033 have been used and correction for binding energy and O132300100034 Coulomb deflection were used. O132300100035 The Dy-isotope is populated via three different O132300100036 reaction channels. Based on these cross-section O132300100037 measurements the reactions Gd-158,160(Li-7,(p,d,t)xn) O132300100038 at a beam energy of 56-MeV were employed to populate O132300100039 high-spin states in the band crossing region of the O132300100040 heavy even Dy-isotopes (second experiment, at LNL) O132300100041 METHOD (EDE) O132300100042 (COINC) O132300100043 STATUS (CURVE) O132300100044 ENDBIB 42 0 O132300100045 NOCOMMON 0 0 O132300100046 ENDSUBENT 45 0 O132300199999 SUBENT O1323002 20070607 O030O132300200001 BIB 5 14 O132300200002 REACTION (64-GD-160(3-LI-7,7N)67-HO-160,,SIG) Fig 1 O132300200003 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300200004 FACILITY (VDGT,2GERMPH) O132300200005 DETECTOR (GE) Seven Ge-detectors O132300200006 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300200007 100-mum, E-detector is 1000-mum, in forward direction O132300200008 and a 300-mum Si-detector in the backward direction. O132300200009 A 470-mum Al-absorber was mounted in front of the O132300200010 delta-E detector to protect it against elastically O132300200011 scattered Li-7 ions. O132300200012 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300200013 about 20%. O132300200014 (ERR-DIG).Data-point reader uncertainty. O132300200015 (EN-ERR-DIG).Digitizing error of incident energy. O132300200016 ENDBIB 14 0 O132300200017 COMMON 3 3 O132300200018 EN-ERR-DIG ERR-DIG DATA-ERR O132300200019 MEV PER-CENT PER-CENT O132300200020 0.19 5. 20. O132300200021 ENDCOMMON 3 0 O132300200022 DATA 2 2 O132300200023 EN DATA O132300200024 MEV MB O132300200025 60.84 2.1 O132300200026 66.87 33.6 O132300200027 ENDDATA 4 0 O132300200028 ENDSUBENT 27 0 O132300299999 SUBENT O1323003 20070607 O030O132300300001 BIB 5 14 O132300300002 REACTION (64-GD-160(3-LI-7,6N)67-HO-161,,SIG) Fig 1 O132300300003 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300300004 FACILITY (VDGT,2GERMPH) O132300300005 DETECTOR (GE) Seven Ge-detectors O132300300006 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300300007 100-mum, E-detector is 1000-mum, in forward direction O132300300008 and a 300-mum Si-detector in the backward direction. O132300300009 A 470-mum Al-absorber was mounted in front of the O132300300010 delta-E detector to protect it against elastically O132300300011 scattered Li-7 ions. O132300300012 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300300013 about 20%. O132300300014 (ERR-DIG).Data-point reader uncertainty. O132300300015 (EN-ERR-DIG).Digitizing error of incident energy. O132300300016 ENDBIB 14 0 O132300300017 COMMON 3 3 O132300300018 EN-ERR-DIG ERR-DIG DATA-ERR O132300300019 MEV PER-CENT PER-CENT O132300300020 0.19 5. 20. O132300300021 ENDCOMMON 3 0 O132300300022 DATA 2 4 O132300300023 EN DATA O132300300024 MEV MB O132300300025 50.83 203. O132300300026 55.95 515. O132300300027 61.08 404. O132300300028 66.86 305. O132300300029 ENDDATA 6 0 O132300300030 ENDSUBENT 29 0 O132300399999 SUBENT O1323004 20070607 O030O132300400001 BIB 5 14 O132300400002 REACTION (64-GD-160(3-LI-7,5N)67-HO-162,,SIG) Fig 1 O132300400003 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300400004 FACILITY (VDGT,2GERMPH) O132300400005 DETECTOR (GE) Seven Ge-detectors O132300400006 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300400007 100-mum, E-detector is 1000-mum, in forward direction O132300400008 and a 300-mum Si-detector in the backward direction. O132300400009 A 470-mum Al-absorber was mounted in front of the O132300400010 delta-E detector to protect it against elastically O132300400011 scattered Li-7 ions. O132300400012 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300400013 about 20%. O132300400014 (ERR-DIG).Data-point reader uncertainty. O132300400015 (EN-ERR-DIG).Digitizing error of incident energy. O132300400016 ENDBIB 14 0 O132300400017 COMMON 3 3 O132300400018 EN-ERR-DIG ERR-DIG DATA-ERR O132300400019 MEV PER-CENT PER-CENT O132300400020 0.19 5. 20. O132300400021 ENDCOMMON 3 0 O132300400022 DATA 2 5 O132300400023 EN DATA O132300400024 MEV MB O132300400025 34.95 3.95 O132300400026 39.93 79. O132300400027 56.09 184. O132300400028 60.82 62. O132300400029 66.87 26.9 O132300400030 ENDDATA 7 0 O132300400031 ENDSUBENT 30 0 O132300499999 SUBENT O1323005 20070607 O030O132300500001 BIB 5 14 O132300500002 REACTION (64-GD-160(3-LI-7,4N)67-HO-163,,SIG) Fig 1 O132300500003 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300500004 FACILITY (VDGT,2GERMPH) O132300500005 DETECTOR (GE) Seven Ge-detectors O132300500006 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300500007 100-mum, E-detector is 1000-mum, in forward direction O132300500008 and a 300-mum Si-detector in the backward direction. O132300500009 A 470-mum Al-absorber was mounted in front of the O132300500010 delta-E detector to protect it against elastically O132300500011 scattered Li-7 ions. O132300500012 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300500013 about 20%. O132300500014 (ERR-DIG).Data-point reader uncertainty. O132300500015 (EN-ERR-DIG).Digitizing error of incident energy. O132300500016 ENDBIB 14 0 O132300500017 COMMON 3 3 O132300500018 EN-ERR-DIG ERR-DIG DATA-ERR O132300500019 MEV PER-CENT PER-CENT O132300500020 0.19 5. 20. O132300500021 ENDCOMMON 3 0 O132300500022 DATA 2 4 O132300500023 EN DATA O132300500024 MEV MB O132300500025 34.93 156. O132300500026 40.19 122. O132300500027 50.97 20. O132300500028 55.97 12.1 O132300500029 ENDDATA 6 0 O132300500030 ENDSUBENT 29 0 O132300599999 SUBENT O1323006 20070607 O030O132300600001 BIB 5 15 O132300600002 REACTION (64-GD-160(3-LI-7,X)66-DY-160,,SIG) Fig 1 O132300600003 charged-particle channels O132300600004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300600005 FACILITY (VDGT,2GERMPH) O132300600006 DETECTOR (GE) Seven Ge-detectors O132300600007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300600008 100-mum, E-detector is 1000-mum, in forward direction O132300600009 and a 300-mum Si-detector in the backward direction. O132300600010 A 470-mum Al-absorber was mounted in front of the O132300600011 delta-E detector to protect it against elastically O132300600012 scattered Li-7 ions. O132300600013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300600014 about 20%. O132300600015 (ERR-DIG).Data-point reader uncertainty. O132300600016 (EN-ERR-DIG).Digitizing error of incident energy. O132300600017 ENDBIB 15 0 O132300600018 COMMON 3 3 O132300600019 EN-ERR-DIG ERR-DIG DATA-ERR O132300600020 MEV PER-CENT PER-CENT O132300600021 0.19 6. 20. O132300600022 ENDCOMMON 3 0 O132300600023 DATA 2 4 O132300600024 EN DATA O132300600025 MEV MB O132300600026 51.11 0.276 O132300600027 55.88 11.8 O132300600028 61.16 20.3 O132300600029 67.1 81. O132300600030 ENDDATA 6 0 O132300600031 ENDSUBENT 30 0 O132300699999 SUBENT O1323007 20070607 O030O132300700001 BIB 5 15 O132300700002 REACTION (64-GD-160(3-LI-7,X)66-DY-161,,SIG) Fig 1 O132300700003 charged-particle channels O132300700004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300700005 FACILITY (VDGT,2GERMPH) O132300700006 DETECTOR (GE) Seven Ge-detectors O132300700007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300700008 100-mum, E-detector is 1000-mum, in forward direction O132300700009 and a 300-mum Si-detector in the backward direction. O132300700010 A 470-mum Al-absorber was mounted in front of the O132300700011 delta-E detector to protect it against elastically O132300700012 scattered Li-7 ions. O132300700013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300700014 about 20%. O132300700015 (ERR-DIG).Data-point reader uncertainty. O132300700016 (EN-ERR-DIG).Digitizing error of incident energy. O132300700017 ENDBIB 15 0 O132300700018 COMMON 3 3 O132300700019 EN-ERR-DIG ERR-DIG DATA-ERR O132300700020 MEV PER-CENT PER-CENT O132300700021 0.19 6. 20. O132300700022 ENDCOMMON 3 0 O132300700023 DATA 2 4 O132300700024 EN DATA O132300700025 MEV MB O132300700026 51.13 6.2 O132300700027 56.15 41.9 O132300700028 61.03 43. O132300700029 67.1 75. O132300700030 ENDDATA 6 0 O132300700031 ENDSUBENT 30 0 O132300799999 SUBENT O1323008 20070607 O030O132300800001 BIB 5 15 O132300800002 REACTION (64-GD-160(3-LI-7,X)66-DY-162,,SIG) Fig 1 O132300800003 charged-particle channels O132300800004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300800005 FACILITY (VDGT,2GERMPH) O132300800006 DETECTOR (GE) Seven Ge-detectors O132300800007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300800008 100-mum, E-detector is 1000-mum, in forward direction O132300800009 and a 300-mum Si-detector in the backward direction. O132300800010 A 470-mum Al-absorber was mounted in front of the O132300800011 delta-E detector to protect it against elastically O132300800012 scattered Li-7 ions. O132300800013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300800014 about 20%. O132300800015 (ERR-DIG).Data-point reader uncertainty. O132300800016 (EN-ERR-DIG).Digitizing error of incident energy. O132300800017 ENDBIB 15 0 O132300800018 COMMON 3 3 O132300800019 EN-ERR-DIG ERR-DIG DATA-ERR O132300800020 MEV PER-CENT PER-CENT O132300800021 0.19 6. 20. O132300800022 ENDCOMMON 3 0 O132300800023 DATA 2 6 O132300800024 EN DATA O132300800025 MEV MB O132300800026 35.03 19. O132300800027 40.05 76. O132300800028 51.27 116. O132300800029 56.28 168. O132300800030 61.03 89. O132300800031 67.1 50. O132300800032 ENDDATA 8 0 O132300800033 ENDSUBENT 32 0 O132300899999 SUBENT O1323009 20070607 O030O132300900001 BIB 5 15 O132300900002 REACTION (64-GD-160(3-LI-7,X)66-DY-163,,SIG) Fig 1 O132300900003 charged-particle channels O132300900004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132300900005 FACILITY (VDGT,2GERMPH) O132300900006 DETECTOR (GE) Seven Ge-detectors O132300900007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132300900008 100-mum, E-detector is 1000-mum, in forward direction O132300900009 and a 300-mum Si-detector in the backward direction. O132300900010 A 470-mum Al-absorber was mounted in front of the O132300900011 delta-E detector to protect it against elastically O132300900012 scattered Li-7 ions. O132300900013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132300900014 about 20%. O132300900015 (ERR-DIG).Data-point reader uncertainty. O132300900016 (EN-ERR-DIG).Digitizing error of incident energy. O132300900017 ENDBIB 15 0 O132300900018 COMMON 3 3 O132300900019 EN-ERR-DIG ERR-DIG DATA-ERR O132300900020 MEV PER-CENT PER-CENT O132300900021 0.19 6. 20. O132300900022 ENDCOMMON 3 0 O132300900023 DATA 2 4 O132300900024 EN DATA O132300900025 MEV MB O132300900026 34.89 2.85 O132300900027 40.04 11.2 O132300900028 51. 16.8 O132300900029 56.01 12.5 O132300900030 ENDDATA 6 0 O132300900031 ENDSUBENT 30 0 O132300999999 SUBENT O1323010 20070607 O030O132301000001 BIB 5 15 O132301000002 REACTION (64-GD-160(3-LI-7,X)66-DY-164,,SIG) Fig 1 O132301000003 charged-particle channels O132301000004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132301000005 FACILITY (VDGT,2GERMPH) O132301000006 DETECTOR (GE) Seven Ge-detectors O132301000007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132301000008 100-mum, E-detector is 1000-mum, in forward direction O132301000009 and a 300-mum Si-detector in the backward direction. O132301000010 A 470-mum Al-absorber was mounted in front of the O132301000011 delta-E detector to protect it against elastically O132301000012 scattered Li-7 ions. O132301000013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132301000014 about 20%. O132301000015 (ERR-DIG).Data-point reader uncertainty. O132301000016 (EN-ERR-DIG).Digitizing error of incident energy. O132301000017 ENDBIB 15 0 O132301000018 COMMON 3 3 O132301000019 EN-ERR-DIG ERR-DIG DATA-ERR O132301000020 MEV PER-CENT PER-CENT O132301000021 0.19 6. 20. O132301000022 ENDCOMMON 3 0 O132301000023 DATA 2 3 O132301000024 EN DATA O132301000025 MEV MB O132301000026 34.89 4.2 O132301000027 40.04 9.7 O132301000028 51.12 2.39 O132301000029 ENDDATA 5 0 O132301000030 ENDSUBENT 29 0 O132301099999 SUBENT O1323011 20070607 O030O132301100001 BIB 5 15 O132301100002 REACTION (64-GD-160(3-LI-7,X)64-GD-160,,SIG) Fig 1 O132301100003 charged-particle channels O132301100004 SAMPLE A 3-mg/cm**2 thick Gd-160 foil was used. O132301100005 FACILITY (VDGT,2GERMPH) O132301100006 DETECTOR (GE) Seven Ge-detectors O132301100007 (TELES) Delta-E-E Si-ring telescope, delta-E is O132301100008 100-mum, E-detector is 1000-mum, in forward direction O132301100009 and a 300-mum Si-detector in the backward direction. O132301100010 A 470-mum Al-absorber was mounted in front of the O132301100011 delta-E detector to protect it against elastically O132301100012 scattered Li-7 ions. O132301100013 ERR-ANALYS (DATA-ERR).The uncertainty is reported by authors is O132301100014 about 20%. O132301100015 (ERR-DIG).Data-point reader uncertainty. O132301100016 (EN-ERR-DIG).Digitizing error of incident energy. O132301100017 ENDBIB 15 0 O132301100018 COMMON 3 3 O132301100019 EN-ERR-DIG ERR-DIG DATA-ERR O132301100020 MEV PER-CENT PER-CENT O132301100021 0.19 6. 20. O132301100022 ENDCOMMON 3 0 O132301100023 DATA 2 3 O132301100024 EN DATA O132301100025 MEV MB O132301100026 56.14 4.8 O132301100027 61.15 8.2 O132301100028 67.22 10. O132301100029 ENDDATA 5 0 O132301100030 ENDSUBENT 29 0 O132301199999 SUBENT O1323012 20070607 O030O132301200001 BIB 6 19 O132301200002 REACTION (64-GD-160(3-LI-7,X)1-H-1,,DA,,REL) Fig 3 O132301200003 SAMPLE A 3.7-mg/cm**2 Gd-158 and 3.9-mg/cm**2 Gd-160 foil wereO132301200004 used. O132301200005 FACILITY (VDGT,2ITYPAD) The XTU tandem accelerator. O132301200006 DETECTOR (GE) 40-compton-suppressed Ge-detectors of the GASP O132301200007 array and the 80-element BGO inner ball for the O132301200008 gamma-radiation detection. O132301200009 (TELES) The Si-ball ISIS, consisting of 40 SI-delta-E-EO132301200010 telescopes. O132301200011 Absorber tube consisting of 100-muM Cu and 12-muM Al O132301200012 was mounted around the beam axis was used to protect O132301200013 the Si-detectors from damage by scattered beam O132301200014 particles. O132301200015 COMMENT *By authors*.For an incomplete fusion reaction only O132301200016 part of the projectile is fusing with the target nucleiO132301200017 while the rest is continuing to fly in the forward O132301200018 direction. O132301200019 ERR-ANALYS (ERR-DIG).Data-point reader uncertainty. O132301200020 (ANG-ERR-D).Digitizing error of charged particle angle.O132301200021 ENDBIB 19 0 O132301200022 COMMON 3 3 O132301200023 EN ANG-ERR-D ERR-DIG O132301200024 MEV ADEG ARB-UNITS O132301200025 56. 0.5 0.7 O132301200026 ENDCOMMON 3 0 O132301200027 DATA 2 6 O132301200028 ANG DATA O132301200029 ADEG ARB-UNITS O132301200030 58.6 57.2 O132301200031 71.8 32.2 O132301200032 89.7 14.8 O132301200033 107.8 11.2 O132301200034 120.7 14.2 O132301200035 145.1 7.7 O132301200036 ENDDATA 8 0 O132301200037 ENDSUBENT 36 0 O132301299999 SUBENT O1323013 20070607 O030O132301300001 BIB 7 20 O132301300002 REACTION (64-GD-160(3-LI-7,X)1-H-2,,DA,,REL) Fig 3 O132301300003 SAMPLE A 3.7-mg/cm**2 Gd-158 and 3.9-mg/cm**2 Gd-160 foil wereO132301300004 used. O132301300005 FACILITY (VDGT,2ITYPAD) The XTU tandem accelerator. O132301300006 PART-DET (P,G) O132301300007 DETECTOR (GE) 40-compton-suppressed Ge-detectors of the GASP O132301300008 array and the 80-element BGO inner ball for the O132301300009 gamma-radiation detection. O132301300010 (TELES) The Si-ball ISIS, consisting of 40 SI-delta-E-EO132301300011 telescopes. O132301300012 Absorber tube consisting of 100-mum Cu and 12-mum Al O132301300013 was mounted around the beam axis was used to protect O132301300014 the Si-detectors from damage by scattered beam O132301300015 particles. O132301300016 COMMENT *By authors*.For an incomplete fusion reaction only O132301300017 part of the projectile is fusing with the target nucleiO132301300018 while the rest is continuing to fly in the forward O132301300019 direction. O132301300020 ERR-ANALYS (ERR-DIG).Data-point reader uncertainty. O132301300021 (ANG-ERR-D).Digitizing error of charged particle angle.O132301300022 ENDBIB 20 0 O132301300023 COMMON 3 3 O132301300024 EN ANG-ERR-D ERR-DIG O132301300025 MEV ADEG ARB-UNITS O132301300026 56. 0.5 0.7 O132301300027 ENDCOMMON 3 0 O132301300028 DATA 2 5 O132301300029 ANG DATA O132301300030 ADEG ARB-UNITS O132301300031 58.1 31.1 O132301300032 71.2 16.6 O132301300033 89.4 4.4 O132301300034 107.9 3.6 O132301300035 120.8 2.3 O132301300036 ENDDATA 7 0 O132301300037 ENDSUBENT 36 0 O132301399999 SUBENT O1323014 20070607 O030O132301400001 BIB 7 20 O132301400002 REACTION (64-GD-160(3-LI-7,X)1-H-3,,DA,,REL) Fig 3 O132301400003 SAMPLE A 3.7-mg/cm**2 Gd-158 and 3.9-mg/cm**2 Gd-160 foil wereO132301400004 used. O132301400005 FACILITY (VDGT,2ITYPAD) The XTU tandem accelerator. O132301400006 PART-DET (P,G) O132301400007 DETECTOR (GE) 40-compton-suppressed Ge-detectors of the GASP O132301400008 array and the 80-element BGO inner ball for the O132301400009 gamma-radiation detection. O132301400010 (TELES) The Si-ball ISIS, consisting of 40 SI-delta-E-EO132301400011 telescopes. O132301400012 Absorber tube consisting of 100-mum Cu and 12-mum Al O132301400013 was mounted around the beam axis was used to protect O132301400014 the Si-detectors from damage by scattered beam O132301400015 particles. O132301400016 COMMENT *By authors*.For an incomplete fusion reaction only O132301400017 part of the projectile is fusing with the target nucleiO132301400018 while the rest is continuing to fly in the forward O132301400019 direction. O132301400020 ERR-ANALYS (ERR-DIG).Data-point reader uncertainty. O132301400021 (ANG-ERR-D).Digitizing error of charged particle angle.O132301400022 ENDBIB 20 0 O132301400023 COMMON 3 3 O132301400024 EN ANG-ERR-D ERR-DIG O132301400025 MEV ADEG ARB-UNITS O132301400026 56. 0.5 0.7 O132301400027 ENDCOMMON 3 0 O132301400028 DATA 2 7 O132301400029 ANG DATA O132301400030 ADEG ARB-UNITS O132301400031 33.8 99.6 O132301400032 58.7 11.7 O132301400033 72.1 4.7 O132301400034 89.4 2. O132301400035 107.9 1.7 O132301400036 121.2 1.8 O132301400037 145.1 1.6 O132301400038 ENDDATA 9 0 O132301400039 ENDSUBENT 38 0 O132301499999 ENDENTRY 14 0 O132399999999