ENTRY O1130 20080515 O035O113000000001 SUBENT O1130001 20080515 O035O113000100001 BIB 13 34 O113000100002 TITLE Measurement of the analyzing power of elastic proton- O113000100003 proton scattering at 582-MeV. O113000100004 AUTHOR (A.Berdoz, B.Favier, F.Foroughi, C.Weddigen) O113000100005 INSTITUTE (2SWTNEU) Institute de Physique O113000100006 (2GERKFK) Institut fuer Kernphysik O113000100007 (2GERKRU) Institut fuer Experimentelle Kernphysik. O113000100008 REFERENCE (J,JP/G,9,L261,1983) Letter to the Editor. O113000100009 REL-REF (R,O1131001,A.BERDOZ+,J,JP/G,8,1363,1982) Details of O113000100010 experiment. O113000100011 SAMPLE Two small CH(2) targets, 10*10*2.3-mm**3 and O113000100012 10*10*1.5-mm**3, were used for data taking while two O113000100013 corresponding C-targets, 10*10*1-mm**3 and 10*10*0.5- O113000100014 mm*3, were used to find the background contribution. O113000100015 The thinner targets used for the three most forward O113000100016 angles were oriented at an angle of +35-degree with O113000100017 respect to the beam direction to reduce the energy lossO113000100018 of the recoil protons. O113000100019 COMMENT -By authors. Test without the target showed that the O113000100020 air surrounding it contributes to the background. Test O113000100021 with a large He-gas target replacing air showed only O113000100022 accidentals. Therefore the fact that was chose C-targetO113000100023 with C amounts equivalent to those of the CH(2) targetsO113000100024 accounts correctly for the air contribution. O113000100025 DETECTOR (TELES,SCIN,SCIN) Two scintillators 5*5-cm**2 and O113000100026 8*8-cm**2 detected P-P elastic scattering events inO113000100027 coincidence. O113000100028 (MWDC) Two the multi-wire ionization chambers. O113000100029 ERR-ANALYS (EN-ERR) The uncertainty of beam energy. O113000100030 FACILITY (CYCLO,2SWTVIL) O113000100031 METHOD (TOF) O113000100032 (EDE) O113000100033 STATUS (TABLE) O113000100034 HISTORY (20040216C) O113000100035 (20080515A) Correction in Reference has been done. O113000100036 ENDBIB 34 0 O113000100037 COMMON 2 3 O113000100038 EN EN-ERR O113000100039 MEV MEV O113000100040 582. 1.5 O113000100041 ENDCOMMON 3 0 O113000100042 ENDSUBENT 41 0 O113000199999 SUBENT O1130002 20040512 0000O113000200001 BIB 2 5 O113000200002 REACTION (1-H-1(P,EL)1-H-1,,POL/DA,,ANA) O113000200003 ERR-ANALYS (ERR-S) Errors are statistical only, include errors dueO113000200004 to background subtraction. An additional common error O113000200005 of 1% is due to the uncertainty in the beam O113000200006 polarization. O113000200007 ENDBIB 5 0 O113000200008 NOCOMMON 0 0 O113000200009 DATA 3 14 O113000200010 ANG-CM DATA ERR-S O113000200011 ADEG NO-DIM NO-DIM O113000200012 20. 0.4153 0.0023 O113000200013 25. 0.4731 0.0023 O113000200014 30. 0.5075 0.0034 O113000200015 35. 0.5272 0.0023 O113000200016 37.5 0.5346 0.0036 O113000200017 40. 0.5296 0.0023 O113000200018 45. 0.5186 0.0024 O113000200019 50. 0.4901 0.0026 O113000200020 55. 0.451 0.0024 O113000200021 60. 0.4094 0.0033 O113000200022 65. 0.3537 0.0022 O113000200023 70. 0.2966 0.0028 O113000200024 75. 0.2321 0.0046 O113000200025 80. 0.1533 0.0025 O113000200026 ENDDATA 16 0 O113000200027 ENDSUBENT 26 0 O113000299999 ENDENTRY 2 0 O113099999999