ENTRY O1128 20040510 0000O112800000001 SUBENT O1128001 20040510 0000O112800100001 BIB 11 27 O112800100002 TITLE Measurement of the pip+p(pol) analyzing power at O112800100003 68.3-MeV. O112800100004 AUTHOR (R.Wieser, A.Denig, U.Vin Hagel, Ch.Joram, W.Kluge, O112800100005 R.Andermann, R.Bilger, H.Clement, K.Fohl, K.Heitlinger,O112800100006 G.J.Wagner, B.Van Den Brandt, F.Foroughi, P.Hautle, O112800100007 A.Konter, S.Mango, A.Kovalev) O112800100008 INSTITUTE (2GERKRU) O112800100009 (2GERTUE) O112800100010 (2SWTPSI) O112800100011 (4RUSLIN) O112800100012 REFERENCE (J,PR/C,54,1930,1996) O112800100013 HISTORY (20040213C) O112800100014 (20040510U) Last checking has been done. O112800100015 SAMPLE The target material consisted of 95% butanol and 5% O112800100016 water. The target with a volume of 18X18X3 O112800100017 millimeters**3 has been cooled down to O112800100018 70 milliKelvin by a 3-He - 4-He dilution refrigerator.O112800100019 ADD-RES Spectra of pions scattered from the polarized target O112800100020 and the 1-mm carbon target was represented. O112800100021 Phase analysis. O112800100022 DETECTOR (MAGSP) Low energy magneic spectrometer LEPS, which O112800100023 features excellent momentum resolution (~0.2%) and O112800100024 effective muon suppresion. O112800100025 FACILITY (CYCLO,2SWTPSI) O112800100026 METHOD (TOF) O112800100027 (EXTB) O112800100028 STATUS (TABLE) In the paper. O112800100029 ENDBIB 27 0 O112800100030 COMMON 1 3 O112800100031 EN O112800100032 MEV O112800100033 68.3 O112800100034 ENDCOMMON 3 0 O112800100035 ENDSUBENT 34 0 O112800199999 SUBENT O1128002 20040510 0000O112800200001 BIB 4 15 O112800200002 REACTION (1-H-1(PIP,EL)1-H-1,,POL/DA,,ANA) O112800200003 CORRECTION -By authors. A small correction for the different O112800200004 energy loss in the target was applied. O112800200005 ERR-ANALYS (DATA-ERR) The errors of the data are essentially givenO112800200006 by the error of the target polarization, which amount O112800200007 to +-5% and is dominated by the error of the thermal O112800200008 NMR (nuclear magnetic resonance, the NMR signal have O112800200009 been added for each target in order to lower the O112800200010 statistical error). Additional systematic and O112800200011 statistical error of the NMR signals in the polarized O112800200012 state of the target are included, but almost negligibleO112800200013 compared to the +-5% error mentioned. O112800200014 FLAG (1.). Target material was doped by 1% porphyrexide. O112800200015 (2.). Target material was doped by 1.5% EHBA-CR-V O112800200016 complex. O112800200017 ENDBIB 15 0 O112800200018 NOCOMMON 0 0 O112800200019 DATA 4 7 O112800200020 ANG-CM DATA DATA-ERR FLAG O112800200021 ADEG NO-DIM NO-DIM NO-DIM O112800200022 49.07 0.386 0.021 1. O112800200023 49.07 0.408 0.013 2. O112800200024 60.24 0.377 0.019 1. O112800200025 60.24 0.379 0.014 2. O112800200026 71.07 0.331 0.026 1. O112800200027 71.07 0.366 0.018 2. O112800200028 81.54 0.284 0.03 2. O112800200029 ENDDATA 9 0 O112800200030 ENDSUBENT 29 0 O112800299999 ENDENTRY 2 0 O112899999999