ENTRY O1095 20040520 0000O109500000001 SUBENT O1095001 20040520 0000O109500100001 BIB 11 36 O109500100002 TITLE Beta-decay of Ni-54,55 produced by an element-selectiveO109500100003 laser ion source. O109500100004 AUTHOR (I.Reusen, A.Andreyev, J.Andrzejewski,N.Bijnens, O109500100005 S.Franchoo, M.Huyse, Y.Kudryavtsev, K.Kruglov, O109500100006 W.F.Mueller, A.Piechaczek, R.Raabe, K.Rykaczewski, O109500100007 J.Szerypo, P.Van Duppen, J.Van Roosbroeck, W.B.Wauters,O109500100008 A.Wohr) O109500100009 INSTITUTE (2BLGLVN) Institute of Nuclear and Radiation Physics. O109500100010 (4ZZZDUB) O109500100011 (1USALSU) O109500100012 (3POLLOU) O109500100013 (1USAORL) O109500100014 (3POLWWA) O109500100015 (2FR CAE) O109500100016 (2UK OXF) O109500100017 REFERENCE (J,PR/C,59,2416,1999) O109500100018 HISTORY (20040127C) O109500100019 (20040520U) Last checking has been done. O109500100020 SAMPLE The target with a thickness of 3 mg/cm**2 was enriched O109500100021 in Fe-54 up to 96.66%. O109500100022 ADD-RES (DECAY) O109500100023 (STRUC) Gamow-Teller Strengh. O109500100024 DETECTOR (TELES) A del'Ta E-E telescope for the detection of O109500100025 beta+ particles. For Ni-55, a 300-mm**2 and 500-mum O109500100026 thick PIPS detector was used as a del'Ta E detector, inO109500100027 the case of Ni-54 a Ne104 plastic scintillator of 1-mm O109500100028 thickness and in both cases, the E detector was a 5-cm*O109500100029 5-cm NE102A plastic scintillator. O109500100030 (HPGE) A large purity germanium detector with 75% O109500100031 efficiency for the 1332.5-KeV line of Co-60. O109500100032 (NAICR) A 3-inch*3-inch NaI(Tl) detector. O109500100033 FACILITY (OLMS,2BLGLVN) An ion-guide laser ion source has been O109500100034 developed at the LEUVEN isotope separator on-line. O109500100035 METHOD (ASEP) O109500100036 (EDE) O109500100037 STATUS (TABLE) O109500100038 ENDBIB 36 0 O109500100039 NOCOMMON 0 0 O109500100040 ENDSUBENT 39 0 O109500199999 SUBENT O1095002 20040520 0000O109500200001 BIB 4 5 O109500200002 REACTION (26-FE-54(HE3,2N)28-NI-55,,TTY/PY) O109500200003 COMMENT - By authors. An ion source efficiency of 3.7%. O109500200004 DECAY-DATA (28-NI-55,204.MSEC) O109500200005 REL-REF (A,,J.AYSTO+,J,PL/B,138,369,1984) O109500200006 (D,,L.VERMEEREN+,J,PRL,73,1935,1994) O109500200007 ENDBIB 5 0 O109500200008 NOCOMMON 0 0 O109500200009 DATA 3 1 O109500200010 EN DATA ERR-HL O109500200011 MEV PRD/MUCOUL MSEC O109500200012 27. 1208. 3. O109500200013 ENDDATA 3 0 O109500200014 ENDSUBENT 13 0 O109500299999 SUBENT O1095003 20040520 0000O109500300001 BIB 3 7 O109500300002 REACTION (26-FE-54(HE3,3N)28-NI-54,,TTY/PY) O109500300003 DECAY-DATA (28-NI-54,106.MSEC) O109500300004 COMMENT -By authors. The half-life of Ni-54 obtained from O109500300005 fitting the time behavior of the contaminant-free Ni-54O109500300006 data set was 108+-15 msec. A final value of the O109500300007 half-life of Ni-54 is 106+-12 msec taking the weighted O109500300008 average of the two independent results. O109500300009 ENDBIB 7 0 O109500300010 NOCOMMON 0 0 O109500300011 DATA 3 1 O109500300012 EN DATA ERR-HL O109500300013 MEV PRD/MUCOUL MSEC O109500300014 45. 13. 12. O109500300015 ENDDATA 3 0 O109500300016 ENDSUBENT 15 0 O109500399999 ENDENTRY 3 0 O109599999999