ENTRY O1030 20050928 O024O103000000001 SUBENT O1030001 20050928 O024O103000100001 BIB 12 24 O103000100002 TITLE Differential cross sections for elastic scattering of O103000100003 low-energy protons from Mg-26 and Mg-24. O103000100004 AUTHOR (W.N.Wang, K.Lin, C.L.Tung) O103000100005 INSTITUTE (3CHFTHU) O103000100006 REFERENCE (J,CHP,10,1,1972) O103000100007 REL-REF (N,C0855001,E.P.MOORING+,J,PR,84,703,1951) O103000100008 Another measurements of elastic scattering of O103000100009 low-energy protons from Mg-24 O103000100010 HISTORY (20030212C) O103000100011 (20050928A) Reference is corrected O103000100012 (20050928U) Last checking has been done. O103000100013 SAMPLE The targets of Mg-24 and Mg-26 were prepared by the O103000100014 vacuum evaporation of magnesium in high enrichment-99% O103000100015 and were deposited onto a thin carbon backing, 10-mg/ O103000100016 cm**2 thickness. The target thickness was 30-mug/cm**2.O103000100017 DETECTOR (SIBAR) O103000100018 FACILITY (VDG,3CHFTHU) 3-MeV Van de Graaff accelerator. O103000100019 METHOD (BCINT) O103000100020 ERR-ANALYS The experimental uncertainty in the measured absolute O103000100021 cross sections is of the order of 10%. The principal O103000100022 sources of uncertainty were the nonuniformity of the O103000100023 target and the beam integration. O103000100024 (ERR-DIG) Data-point reader uncertainty. O103000100025 STATUS (CURVE).By CAJAD. O103000100026 ENDBIB 24 0 O103000100027 NOCOMMON 0 0 O103000100028 ENDSUBENT 27 0 O103000199999 SUBENT O1030002 20030227 0000O103000200001 BIB 2 2 O103000200002 REACTION (12-MG-26(P,EL)12-MG-26,,DA) Figure 2 O103000200003 ERR-ANALYS (EN-ERR-DIG) Proton beam energy uncertainty. O103000200004 ENDBIB 2 0 O103000200005 COMMON 2 3 O103000200006 EN-ERR-DIG ERR-DIG O103000200007 MEV MB/SR O103000200008 0.005 2. O103000200009 ENDCOMMON 3 0 O103000200010 DATA 3 121 O103000200011 EN ANG-CM DATA O103000200012 MEV ADEG MB/SR O103000200013 1.5 131.7 133.7 O103000200014 1.525 131.7 135.1 O103000200015 1.532 151.2 103.2 O103000200016 1.553 151.2 94.7 O103000200017 1.557 131.7 122.4 O103000200018 1.571 131.7 122.4 O103000200019 1.585 151.2 96.2 O103000200020 1.602 131.7 118.2 O103000200021 1.603 151.2 83.4 O103000200022 1.624 131.7 99.9 O103000200023 1.635 151.2 102.1 O103000200024 1.649 131.7 106.9 O103000200025 1.653 151.2 95. O103000200026 1.674 131.7 108.3 O103000200027 1.677 151.2 86.5 O103000200028 1.699 131.7 94.3 O103000200029 1.706 151.2 79.4 O103000200030 1.724 131.7 98.5 O103000200031 1.731 151.2 95.2 O103000200032 1.741 131.7 101.3 O103000200033 1.748 151.2 83.8 O103000200034 1.773 131.7 91.5 O103000200035 1.78 151.2 71. O103000200036 1.798 131.7 87.2 O103000200037 1.816 151.2 71.1 O103000200038 1.821 131.7 90.5 O103000200039 1.827 151.2 62.5 O103000200040 1.844 131.7 87.2 O103000200041 1.855 151.2 58.3 O103000200042 1.869 131.7 77.4 O103000200043 1.88 151.2 58.4 O103000200044 1.898 131.7 68.9 O103000200045 1.905 151.2 71.4 O103000200046 1.923 131.7 59.8 O103000200047 1.926 151.2 54.2 O103000200048 1.947 131.7 50.7 O103000200049 1.954 151.2 37.1 O103000200050 1.965 131.7 39.4 O103000200051 1.976 151.2 21.4 O103000200052 2. 131.7 119.6 O103000200053 2.004 151.2 160.5 O103000200054 2.022 131.7 308.2 O103000200055 2.029 151.2 406.9 O103000200056 2.043 131.7 270.2 O103000200057 2.057 151.2 319.6 O103000200058 2.068 131.7 199.8 O103000200059 2.075 151.2 199.4 O103000200060 2.099 131.7 168.9 O103000200061 2.1 151.2 116.3 O103000200062 2.118 131.7 122.4 O103000200063 2.128 151.2 80.6 O103000200064 2.142 131.7 178.7 O103000200065 2.153 151.2 199.6 O103000200066 2.171 151.2 140.9 O103000200067 2.174 131.7 137.9 O103000200068 2.196 151.2 119.5 O103000200069 2.199 131.7 130.9 O103000200070 2.221 131.7 114. O103000200071 2.224 151.2 96.6 O103000200072 2.245 131.7 97.1 O103000200073 2.256 151.2 85.3 O103000200074 2.267 131.7 106.9 O103000200075 2.284 151.2 81.1 O103000200076 2.292 131.7 85.8 O103000200077 2.302 151.2 85.4 O103000200078 2.32 131.7 81.6 O103000200079 2.327 151.2 76.9 O103000200080 2.338 131.7 54.9 O103000200081 2.348 151.2 32.5 O103000200082 2.37 131.7 94.3 O103000200083 2.377 151.2 102.8 O103000200084 2.395 131.7 94.3 O103000200085 2.398 151.2 98.6 O103000200086 2.419 131.7 119.6 O103000200087 2.43 151.2 133. O103000200088 2.441 131.7 97.1 O103000200089 2.455 151.2 95.9 O103000200090 2.466 131.7 83. O103000200091 2.476 151.2 93.1 O103000200092 2.487 131.7 77.4 O103000200093 2.505 151.2 74.5 O103000200094 2.515 131.7 77.4 O103000200095 2.526 151.2 63.1 O103000200096 2.54 131.7 67.5 O103000200097 2.554 151.2 76.1 O103000200098 2.558 131.7 63.3 O103000200099 2.583 151.2 71.9 O103000200100 2.586 131.7 68.9 O103000200101 2.6 151.2 66.2 O103000200102 2.617 131.7 71.8 O103000200103 2.618 151.2 60.5 O103000200104 2.643 131.7 64.7 O103000200105 2.647 151.2 89.3 O103000200106 2.661 131.7 73.2 O103000200107 2.671 151.2 70.7 O103000200108 2.689 131.7 70.4 O103000200109 2.7 151.2 63.6 O103000200110 2.714 131.7 61.9 O103000200111 2.728 151.2 80.9 O103000200112 2.739 131.7 57.7 O103000200113 2.753 151.2 52.3 O103000200114 2.767 131.7 71.8 O103000200115 2.781 151.2 58.1 O103000200116 2.789 131.7 54.9 O103000200117 2.799 151.2 53.9 O103000200118 2.813 131.7 63.3 O103000200119 2.828 151.2 58.3 O103000200120 2.838 131.7 56.3 O103000200121 2.849 151.2 55.5 O103000200122 2.863 131.7 45. O103000200123 2.87 151.2 46.9 O103000200124 2.891 131.7 56.3 O103000200125 2.895 151.2 49.9 O103000200126 2.913 131.7 59.1 O103000200127 2.923 151.2 67.1 O103000200128 2.934 131.7 70.4 O103000200129 2.952 151.2 52.9 O103000200130 2.966 131.7 47.8 O103000200131 2.97 151.2 44.4 O103000200132 2.987 131.7 40.8 O103000200133 2.998 151.2 38.7 O103000200134 ENDDATA 123 0 O103000200135 ENDSUBENT 134 0 O103000299999 SUBENT O1030003 20030227 0000O103000300001 BIB 2 2 O103000300002 REACTION (12-MG-24(P,EL)12-MG-24,,DA) Figure 1 O103000300003 ERR-ANALYS (EN-ERR-DIG) Beam energy uncertainty O103000300004 ENDBIB 2 0 O103000300005 COMMON 2 3 O103000300006 EN-ERR-DIG ERR-DIG O103000300007 MEV MB/SR O103000300008 0.005 1.7 O103000300009 ENDCOMMON 3 0 O103000300010 DATA 3 119 O103000300011 EN ANG-CM DATA O103000300012 MEV ADEG MB/SR O103000300013 1.509 131.7 155.5 O103000300014 1.51 151.2 104.6 O103000300015 1.531 131.7 155.5 O103000300016 1.536 151.2 100.9 O103000300017 1.554 151.2 98.5 O103000300018 1.56 131.7 153. O103000300019 1.578 131.7 146.9 O103000300020 1.579 151.2 89.1 O103000300021 1.601 151.2 79. O103000300022 1.604 131.7 137.2 O103000300023 1.651 131.7 140.8 O103000300024 1.659 151.2 102.5 O103000300025 1.677 131.7 150.5 O103000300026 1.681 151.2 122.2 O103000300027 1.692 151.2 118.5 O103000300028 1.702 131.7 146.8 O103000300029 1.727 131.7 138.3 O103000300030 1.728 151.2 108.8 O103000300031 1.749 131.7 129.8 O103000300032 1.754 151.2 95.3 O103000300033 1.778 131.7 133.4 O103000300034 1.779 151.2 100.3 O103000300035 1.796 131.7 139.4 O103000300036 1.797 151.2 105.3 O103000300037 1.822 131.7 134.6 O103000300038 1.823 151.2 101.7 O103000300039 1.845 151.2 91.9 O103000300040 1.851 131.7 127.2 O103000300041 1.873 131.7 126. O103000300042 1.877 151.2 94.4 O103000300043 1.898 131.7 124.8 O103000300044 1.899 151.2 90.8 O103000300045 1.924 131.7 119.9 O103000300046 1.925 151.2 88.4 O103000300047 1.945 131.7 113.8 O103000300048 1.946 151.2 88.5 O103000300049 1.967 131.7 116.2 O103000300050 1.975 151.2 89.8 O103000300051 2. 131.7 117.4 O103000300052 2.001 151.2 89.8 O103000300053 2.022 131.7 105.2 O103000300054 2.026 151.2 80.1 O103000300055 2.052 151.2 80.1 O103000300056 2.055 131.7 113.7 O103000300057 2.077 151.2 80.2 O103000300058 2.08 131.7 110. O103000300059 2.098 131.7 110. O103000300060 2.099 151.2 80.2 O103000300061 2.127 131.7 106.4 O103000300062 2.128 151.2 80.3 O103000300063 2.149 131.7 106.3 O103000300064 2.157 151.2 81.6 O103000300065 2.174 131.7 105.1 O103000300066 2.175 151.2 79.2 O103000300067 2.2 131.7 103.9 O103000300068 2.201 151.2 75.6 O103000300069 2.222 131.7 100.2 O103000300070 2.23 151.2 78.1 O103000300071 2.247 131.7 96.5 O103000300072 2.252 151.2 75.7 O103000300073 2.277 151.2 74.5 O103000300074 2.28 131.7 91.6 O103000300075 2.301 131.7 89.2 O103000300076 2.302 151.2 73.4 O103000300077 2.323 131.7 89.2 O103000300078 2.324 151.2 73.4 O103000300079 2.352 131.7 91.6 O103000300080 2.353 151.2 64.9 O103000300081 2.374 131.7 86.7 O103000300082 2.382 151.2 68.7 O103000300083 2.396 131.7 87.9 O103000300084 2.404 151.2 69.9 O103000300085 2.422 131.7 90.3 O103000300086 2.43 151.2 71.2 O103000300087 2.451 131.7 87.9 O103000300088 2.451 151.2 57.8 O103000300089 2.465 131.7 80.6 O103000300090 2.47 151.2 62.7 O103000300091 2.502 131.7 75.7 O103000300092 2.506 151.2 59.1 O103000300093 2.524 151.2 55.5 O103000300094 2.55 151.2 59.2 O103000300095 2.552 131.7 72. O103000300096 2.571 131.7 70.7 O103000300097 2.575 151.2 55.6 O103000300098 2.596 131.7 63.4 O103000300099 2.6 151.2 49.6 O103000300100 2.622 151.2 50.8 O103000300101 2.625 131.7 67.1 O103000300102 2.65 131.7 63.4 O103000300103 2.651 151.2 52.1 O103000300104 2.677 151.2 49.7 O103000300105 2.68 131.7 62.1 O103000300106 2.699 151.2 49.8 O103000300107 2.701 131.7 60.9 O103000300108 2.728 151.2 46.2 O103000300109 2.73 131.7 57.2 O103000300110 2.745 131.7 54.8 O103000300111 2.753 151.2 45. O103000300112 2.778 131.7 49.9 O103000300113 2.779 151.2 41.4 O103000300114 2.8 151.2 37.8 O103000300115 2.803 131.7 45. O103000300116 2.825 131.7 43.8 O103000300117 2.829 151.2 37.8 O103000300118 2.855 151.2 36.7 O103000300119 2.858 131.7 41.3 O103000300120 2.872 131.7 38.9 O103000300121 2.873 151.2 33. O103000300122 2.898 131.7 32.8 O103000300123 2.906 151.2 29.4 O103000300124 2.93 131.7 27.9 O103000300125 2.935 151.2 25.8 O103000300126 2.949 131.7 24.2 O103000300127 2.953 151.2 24.6 O103000300128 2.974 131.7 20.6 O103000300129 2.978 151.2 22.2 O103000300130 2.999 131.7 18.1 O103000300131 3.004 151.2 18.6 O103000300132 ENDDATA 121 0 O103000300133 ENDSUBENT 132 0 O103000399999 SUBENT O1030004 20030227 0000O103000400001 BIB 2 2 O103000400002 REACTION (12-MG-24(P,EL)12-MG-24,,DA) Figure 3 O103000400003 ERR-ANALYS (ANG-ERR-D) Data point reader uncertainty O103000400004 ENDBIB 2 0 O103000400005 COMMON 2 3 O103000400006 ANG-ERR-D ERR-DIG O103000400007 ADEG MB/SR O103000400008 1.2 6. O103000400009 ENDCOMMON 3 0 O103000400010 DATA 3 36 O103000400011 EN ANG-CM DATA-CM O103000400012 MEV ADEG MB/SR O103000400013 2.6 51.1 893. O103000400014 2.6 61.5 515. O103000400015 2.6 71.3 279. O103000400016 2.6 80.6 176. O103000400017 2.6 90.8 133. O103000400018 2.6 101. 77. O103000400019 2.6 111.3 56. O103000400020 2.6 121.7 56. O103000400021 2.6 132. 60. O103000400022 2.6 140. 30. O103000400023 2.6 150.9 39. O103000400024 2.6 160.4 30. O103000400025 2.8 52.5 773. O103000400026 2.8 61.9 382. O103000400027 2.8 71.1 270. O103000400028 2.8 81.1 155. O103000400029 2.8 89.6 120. O103000400030 2.8 91.3 120. O103000400031 2.8 93.8 125. O103000400032 2.8 100.6 69. O103000400033 2.8 109.9 52. O103000400034 2.8 119.3 47. O103000400035 2.8 128.7 43. O103000400036 2.8 139.8 30. O103000400037 2.8 150. 30. O103000400038 2.8 159.4 22. O103000400039 3. 60.3 369. O103000400040 3. 70.5 219. O103000400041 3. 80.8 120. O103000400042 3. 91. 47. O103000400043 3. 100.4 30. O103000400044 3. 110.7 22. O103000400045 3. 121.8 13. O103000400046 3. 131.2 17. O103000400047 3. 141.4 17. O103000400048 3. 151.7 17. O103000400049 ENDDATA 38 0 O103000400050 ENDSUBENT 49 0 O103000499999 SUBENT O1030005 20030227 0000O103000500001 BIB 2 2 O103000500002 REACTION (12-MG-26(P,EL)12-MG-26,,DA) Figure 4 O103000500003 ERR-ANALYS (ANG-ERR-D) Data point reader uncertainty O103000500004 ENDBIB 2 0 O103000500005 COMMON 2 3 O103000500006 ANG-ERR-D ERR-DIG O103000500007 ADEG MB/SR O103000500008 1.1 6. O103000500009 ENDCOMMON 3 0 O103000500010 DATA 3 30 O103000500011 EN ANG-CM DATA-CM O103000500012 MEV ADEG MB/SR O103000500013 1.5 62.7 1013. O103000500014 1.5 80.5 384. O103000500015 1.5 90.7 302. O103000500016 1.5 100.8 239. O103000500017 1.5 109.3 175. O103000500018 1.5 119.5 140. O103000500019 1.5 129.7 116. O103000500020 1.5 139.9 104. O103000500021 1.5 149.3 86. O103000500022 2.03 61.7 373. O103000500023 2.03 70.9 216. O103000500024 2.03 81. 130. O103000500025 2.03 89.5 106. O103000500026 2.03 100.6 117. O103000500027 2.03 110.1 151. O103000500028 2.03 120.4 208. O103000500029 2.03 131.6 288. O103000500030 2.03 142.8 346. O103000500031 2.03 150.6 409. O103000500032 2.5 50.5 870. O103000500033 2.5 60.9 454. O103000500034 2.5 70.9 281. O103000500035 2.5 79.3 206. O103000500036 2.5 90.2 142. O103000500037 2.5 101.2 101. O103000500038 2.5 109.7 89. O103000500039 2.5 119.9 83. O103000500040 2.5 130.1 76. O103000500041 2.5 140.3 82. O103000500042 2.5 149.7 64. O103000500043 ENDDATA 32 0 O103000500044 ENDSUBENT 43 0 O103000599999 ENDENTRY 5 0 O103099999999