ENTRY O0972 20030514 0000O097200000001 SUBENT O0972001 20030514 0000O097200100001 BIB 11 22 O097200100002 TITLE Production of 26-Al and 22-Na from proton bombardment O097200100003 of Si, Al and Mg O097200100004 AUTHOR (M.Furukawa, K.Shizuri, K.Komura, K.Sakamoto, S.Tanaka)O097200100005 REFERENCE (J,NP/A,174,539,1971) O097200100006 INSTITUTE (2JPNTOK) Institute for nuclear study O097200100007 (2JPNNAG) Department of chemistry O097200100008 MONITOR (13-AL-27(P,X)11-NA-22,CUM,SIG) O097200100009 MONIT-REF (P0016002,M.FURUKAWA+,J,NP,69,362,1965) O097200100010 FACILITY (CYCLO,2JPNTOK) O097200100011 (CYCLO,2JPNJAE) The cyclotron was used for energy O097200100012 region below 15 MeV. O097200100013 METHOD (STTA) All the targets were prepared from natural O097200100014 metals of high purity O097200100015 (BCINT) O097200100016 (ACTIV) O097200100017 (GSPEC) O097200100018 (EXTB) O097200100019 STATUS (CURVE) By CAJAD. O097200100020 HISTORY (20020909C) O097200100021 (20030514U) Last checking has been done. O097200100022 ERR-ANALYS (EN-ERR) The uncertainty is presented on figures O097200100023 without any analisys. O097200100024 ENDBIB 22 0 O097200100025 NOCOMMON 0 0 O097200100026 ENDSUBENT 25 0 O097200199999 SUBENT O0972002 20030514 0000O097200200001 BIB 7 18 O097200200002 REACTION (12-MG-0(P,X)13-AL-26-G,,SIG) O097200200003 METHOD (CHSEP) O097200200004 (COINC) O097200200005 DETECTOR (COIN,NAICR,NAICR) O097200200006 RAD-DET (13-AL-26-G,AR) O097200200007 DECAY-DATA (13-AL-26-G,7.4E+5YR,B+,,0.85) O097200200008 SAMPLE Thickness of magnesium foils was to be 30-380 O097200200009 milligramm/cm**2 for incident beam energy 52 MeV, and O097200200010 16.6-17.9 milligramm/cm**2 for incident beam energy O097200200011 14.8 MeV. O097200200012 ERR-ANALYS (ERR-T) The uncertainties present the overall O097200200013 uncertainties in the cross sections estimated on the O097200200014 basis of uncertainties in the beam current integration,O097200200015 the target thickness, the recoil loss, the chemical O097200200016 yield, counting statistic and the absolute O097200200017 determination of radioactivity. O097200200018 In the case of the magnesium reaction, the main error O097200200019 was due to counting statistics. O097200200020 ENDBIB 18 0 O097200200021 NOCOMMON 0 0 O097200200022 DATA 4 12 O097200200023 EN EN-ERR DATA ERR-T O097200200024 MEV MEV MB PER-CENT O097200200025 6.18 0.21 4. 18. O097200200026 8.15 0.22 10.8 14. O097200200027 9.84 0.23 10.8 13. O097200200028 11.08 0.25 13. 13. O097200200029 13.09 0.2 10.2 11. O097200200030 14.62 0.24 11.9 13. O097200200031 19.09 0.21 6. 50. O097200200032 19.95 0.28 5.5 30. O097200200033 29.2 1.3 1.05 11. O097200200034 34.3 1.3 1.3 30. O097200200035 40.4 1.3 0.84 18. O097200200036 50.6 1.6 0.64 40. O097200200037 ENDDATA 14 0 O097200200038 ENDSUBENT 37 0 O097200299999 SUBENT O0972003 20030514 0000O097200300001 BIB 6 18 O097200300002 REACTION (13-AL-27(P,X)13-AL-26-G,,SIG) O097200300003 METHOD (CHSEP) O097200300004 (COINC) O097200300005 DETECTOR (COIN,NAICR,NAICR) O097200300006 RAD-DET (13-AL-26-G,AR) O097200300007 DECAY-DATA (13-AL-26-G,7.4E+5YR,B+,,0.85) O097200300008 Thickness of aluminium foils was to be 47-138 O097200300009 milligramm/cm**2 for incident beam energy 57 MeV, and O097200300010 14 milligramm/cm**2 for incident beam energy 52 MeV. O097200300011 ERR-ANALYS (ERR-T) The uncertainties present the overall O097200300012 uncertainties in the cross sections estimated on the O097200300013 basis of uncertainties in the beam current integration,O097200300014 the target thickness, the recoil loss, the chemical O097200300015 yield, counting statistic and the absolute O097200300016 determination of radioactivity. O097200300017 In the case of the aluminium reaction, the main error O097200300018 was due to uncertainty in the beam current O097200300019 determination O097200300020 ENDBIB 18 0 O097200300021 NOCOMMON 0 0 O097200300022 DATA 4 10 O097200300023 EN EN-ERR DATA ERR-T O097200300024 MEV MEV MB PER-CENT O097200300025 15.2 0.2 68. 10. O097200300026 16.8 1.2 120. 8. O097200300027 17.6 0.7 132. 8. O097200300028 18.76 0.25 141. 9. O097200300029 20.71 0.2 163. 8. O097200300030 25.5 0.9 161. 8. O097200300031 31.07 0.22 102. 7. O097200300032 39.28 0.2 82. 6. O097200300033 39.71 0.24 81. 11. O097200300034 51.71 0.24 67. 12. O097200300035 ENDDATA 12 0 O097200300036 ENDSUBENT 35 0 O097200399999 SUBENT O0972004 20030514 0000O097200400001 BIB 7 17 O097200400002 REACTION (14-SI-0(P,X)13-AL-26-G,,SIG) O097200400003 METHOD (CHSEP) O097200400004 (COINC) O097200400005 DETECTOR (COIN,NAICR,NAICR) O097200400006 RAD-DET (13-AL-26-G,AR) O097200400007 DECAY-DATA (13-AL-26-G,7.4E+5YR,B+,,0.85) O097200400008 SAMPLE Thickness of silicon foils was to be 234 milligramm/ O097200400009 cm**2 for incident beam energy 52 MeV. O097200400010 ERR-ANALYS (ERR-T) The uncertainties present the overall O097200400011 uncertainties in the cross sections estimated on the O097200400012 basis of uncertainties in the beam current integration,O097200400013 the target thickness, the recoil loss, the chemical O097200400014 yield, counting statistic and the absolute O097200400015 determination of radioactivity. O097200400016 In the case of the silicon reaction, the main error O097200400017 was due to the uncertainty in beam current O097200400018 determination. O097200400019 ENDBIB 17 0 O097200400020 NOCOMMON 0 0 O097200400021 DATA 4 11 O097200400022 EN EN-ERR DATA ERR-T O097200400023 MEV MEV MB PER-CENT O097200400024 25.7 0.8 1.32 11. O097200400025 29.11 0.2 5.4 11. O097200400026 32.2 1.2 15. 11. O097200400027 35.5 1.1 34.7 8. O097200400028 37.9 0.9 51. 10. O097200400029 39.85 0.21 80. 14. O097200400030 41. 0.7 58. 9. O097200400031 43.6 0.9 60. 10. O097200400032 46.1 0.9 58. 9. O097200400033 48.4 0.9 56. 9. O097200400034 50.9 0.7 53. 9. O097200400035 ENDDATA 13 0 O097200400036 ENDSUBENT 35 0 O097200499999 SUBENT O0972005 20030514 0000O097200500001 BIB 5 16 O097200500002 REACTION (12-MG-0(P,X)11-NA-22,CUM,SIG) O097200500003 RAD-DET (11-NA-22,DG) O097200500004 DECAY-DATA (11-NA-22,2.6YR) O097200500005 SAMPLE Thickness of magnesium foils was to be 30-380 O097200500006 milligramm/cm**2 for incident beam energy 52 MeV, and O097200500007 16.6-17.9 milligramm/cm**2 for incident beam energy O097200500008 14.8 MeV. O097200500009 ERR-ANALYS (ERR-T) The uncertainties present the overall O097200500010 uncertainties in the cross sections estimated on the O097200500011 basis of uncertainties in the beam current integration,O097200500012 the target thickness, the recoil loss, counting O097200500013 statistic and the absolute determination of O097200500014 radioactivity. O097200500015 The errors in the Na-22 formation cross sections are O097200500016 mainly due to the uncertainty of the monitor cross O097200500017 section. O097200500018 ENDBIB 16 0 O097200500019 NOCOMMON 0 0 O097200500020 DATA 4 14 O097200500021 EN EN-ERR DATA ERR-T O097200500022 MEV MEV MB PER-CENT O097200500023 6.57 0.21 0.79 11. O097200500024 8.33 0.21 4.7 9. O097200500025 10.14 0.25 7.4 8. O097200500026 11.8 0.3 8.9 8. O097200500027 13.22 0.2 10.1 8. O097200500028 14.77 0.21 11.3 8. O097200500029 19.3 0.25 6. 7. O097200500030 20.3 0.6 4.8 8. O097200500031 24.1 1.4 8.1 9. O097200500032 28.5 1.6 19.1 7. O097200500033 33.9 1. 46. 9. O097200500034 39.5 1.1 75. 8. O097200500035 46.4 1.1 79. 6. O097200500036 49.9 1. 66. 9. O097200500037 ENDDATA 16 0 O097200500038 ENDSUBENT 37 0 O097200599999 SUBENT O0972006 20030514 0000O097200600001 BIB 5 14 O097200600002 REACTION (14-SI-0(P,X)11-NA-22,CUM,SIG) O097200600003 RAD-DET (11-NA-22,DG) O097200600004 DECAY-DATA (11-NA-22,2.6YR) O097200600005 SAMPLE Thickness of silicon foils was to be 234 O097200600006 milligramm/cm**2 for incident beam energy 52 MeV. O097200600007 ERR-ANALYS (ERR-T) The uncertainties present the overall O097200600008 uncertainties in the cross sections estimated on the O097200600009 basis of uncertainties in the beam current integration,O097200600010 the target thickness, the recoil loss, counting O097200600011 statistic and the absolute determination of O097200600012 radioactivity. O097200600013 The errors in the Na-22 formation cross sections are O097200600014 mainly due to the uncertainty of the monitor cross O097200600015 section. O097200600016 ENDBIB 14 0 O097200600017 NOCOMMON 0 0 O097200600018 DATA 4 10 O097200600019 EN EN-ERR DATA ERR-T O097200600020 MEV MEV MB PER-CENT O097200600021 26. 1.4 7.8E-02 12. O097200600022 29.7 1.6 0.332 9. O097200600023 32.7 1. 0.47 9. O097200600024 35.7 1.1 0.48 8. O097200600025 38.7 1. 0.68 9. O097200600026 41.6 0.9 1.17 9. O097200600027 44.1 0.9 1.98 9. O097200600028 46.5 1.2 3.31 9. O097200600029 48.7 0.8 5.7 9. O097200600030 51.1 0.7 8.9 8. O097200600031 ENDDATA 12 0 O097200600032 ENDSUBENT 31 0 O097200699999 ENDENTRY 6 0 O097299999999