ENTRY O0797 20090828 O040O079700000001 SUBENT O0797001 20090828 O040O079700100001 BIB 14 46 O079700100002 TITLE Tensor analyzing power Ayy of d-p radiative capture O079700100003 REFERENCE (J,NP/A,636,189,1998) O079700100004 AUTHOR (H.Anklin, L.J.De Bewer, S.Buttazzoni, W.Gloekle, O079700100005 J.Golak, A.Honegger, J.Jourdan, H.Kamada, G.Kubon, O079700100006 T.Petitjean, L.M.Qin, I.Sick, Ph.Steiner, H.Witala, O079700100007 M.Zeier, J.Zhao, B.Zihlimann) O079700100008 INSTITUTE (2SWTBAS) Departement fuer Physik und Astronomie. O079700100009 (3POLUJK) Institute of Physics. O079700100010 (2GERBOC) Institut fuer Theoretische Physik II. O079700100011 INC-SOURCE (POLIS) Radio-frequency source. To measure polarizationO079700100012 of the beam elastic scattering on He-4 and C-12 was O079700100013 used. O079700100014 SAMPLE The liquid hydrogen target was cooled to 15.7 K. The O079700100015 target was operated at a pressure of 0.2 bar. The low O079700100016 target pressure allowed us to use Havar windows only O079700100017 2-5 mumeter thick. The energy loss of the deuterons inO079700100018 the target was 0.39 MeV, leading to a mean deuteron O079700100019 energy of 44.56 MeV at the target center. The target O079700100020 thickness has been chosen as thin as possible to keep O079700100021 the multiple scattering of the product 3-He small. O079700100022 PART-DET (G,HE3) O079700100023 DETECTOR (CSICR,NAICR) Photons, with energies of 17 to 23 MeV, O079700100024 were detected by four large CsI(pure)/ NaI(Tl) O079700100025 cylindrical crystal detectors (20 X 20 cm) mounted at O079700100026 several angles around the scattering chamber cit a O079700100027 distance of 80 cm from the target center. CsI(pure),O079700100028 though producing less light than NaI(Tl), has a O079700100029 considerably shorter pulse duration, hence it O079700100030 significantly improves the time-of-flight rejection of O079700100031 background. O079700100032 (SCIN) The He-3 nuclei were detected using two very O079700100033 thin plastic detectors made out of Pilot-U O079700100034 scintillation plastic. This material was chosen O079700100035 because of its short pulse fall time to reduce pileup. O079700100036 To discriminate against the elastically scattered O079700100037 deuterons the plastic detectors were just thick enough O079700100038 to stop the He-3 ions, but not the deuterons. O079700100039 FACILITY (CYCLO,2SWTBAS) O079700100040 METHOD (TOF,COINC) O079700100041 HISTORY (20040628C) O079700100042 (20090828A) Correction in author' list has been done, O079700100043 according V.Zerkin remarks. O079700100044 Spelling error in subent 002. O079700100045 STATUS (TABLE) In the paper. O079700100046 ADD-RES (THEO) O079700100047 ERR-ANALYS (ERR-1) The systematic error of beam polarization. O079700100048 ENDBIB 46 0 O079700100049 COMMON 2 3 O079700100050 EN ERR-1 O079700100051 MEV PER-CENT O079700100052 44.56 1.5 O079700100053 ENDCOMMON 3 0 O079700100054 ENDSUBENT 53 0 O079700199999 SUBENT O0797002 20090828 O040O079700200001 BIB 2 3 O079700200002 REACTION (1-H-1(D,G)2-HE-3,NN,POL/DA,,ANA) O079700200003 ERR-ANALYS (ERR-T).The uncertainty is given in data table by O079700200004 authors. O079700200005 ENDBIB 3 0 O079700200006 NOCOMMON 0 0 O079700200007 DATA 3 11 O079700200008 ANG-CM DATA ERR-T O079700200009 ADEG NO-DIM NO-DIM O079700200010 56.7 0.0105 0.0011 O079700200011 67.5 0.0085 0.0017 O079700200012 80.1 0.0101 0.0014 O079700200013 90.3 0.0095 0.0017 O079700200014 102.3 0.012 0.0014 O079700200015 111.9 0.0172 0.003 O079700200016 123.2 0.0137 0.0011 O079700200017 132.5 0.0131 0.0025 O079700200018 143.3 0.0141 0.0015 O079700200019 153.9 0.0114 0.0036 O079700200020 162.7 0.0134 0.0022 O079700200021 ENDDATA 13 0 O079700200022 ENDSUBENT 21 0 O079700299999 ENDENTRY 2 0 O079799999999