ENTRY O0731 20000427 0000O073100000001 SUBENT O0731001 20000427 0000O073100100001 BIB 10 31 O073100100002 TITLE The Decay Properties of Hg-206 and the Pb(P,3P)Hg-206 O073100100003 Reaction. O073100100004 AUTHOR (G.K.WOLF) O073100100005 INSTITUTE (2ZZZCER) O073100100006 REFERENCE (J,NP/A,116,387,1968) O073100100007 HISTORY (20000321C) O073100100008 (20000321U) Last checking has been done. O073100100009 (20000427A) DATE is corrected O073100100010 SAMPLE The three Lead foils, 80 mg/cm**2 thickness each, were O073100100011 mounted in a stack with three Aluminium foils on each O073100100012 side, the middle ones were 10 Mum and the others 30 MumO073100100013 thick. O073100100014 ADD-RES (DECAY).Hg-206 Decay Properties were investigated. O073100100015 The Half-Life of Hg-206 was determined, Gamma, Beta andO073100100016 Conversion Electron Spectra were measured. O073100100017 DETECTOR (PROPC).Methane-Flow Proportional Counter For Beta O073100100018 Measurements. O073100100019 (NAICR).A 7.6 cm*7.6 cm NaI(Tl) Crystal For Gamma O073100100020 Spectra. O073100100021 (GELI).A 30 cm**3 Coaxial Ge(Li) Detector For Gamma O073100100022 Spectra. O073100100023 (SILI).A 15.2 cm*10.2 cm NaI(Tl) Crystal in CombinationO073100100024 With a 5 mm Si(LI) Detector For Beta-Gamma Coincidence O073100100025 Measurements. O073100100026 (NAICR).Two 3.8 cm NaI(Tl) Crystal For Gamma-Gamma O073100100027 Coincidence Measurements. O073100100028 (SILI).A Si(LI) Detector with an Area of 50 mm**2 O073100100029 (2 MM THICK) For Conversion Electrons. O073100100030 ERR-ANALYS The Overall Yield For the Different Experiments O073100100031 Corrected For Losses by Decay was 0.1-0.2%. O073100100032 STATUS (TABLE) O073100100033 ENDBIB 31 0 O073100100034 NOCOMMON 0 0 O073100100035 ENDSUBENT 34 0 O073100199999 SUBENT O0731002 20000427 0000O073100200001 BIB 10 15 O073100200002 REACTION (82-PB-208(P,3P)80-HG-206,IND,SIG) O073100200003 RAD-DET (80-HG-206,B-) O073100200004 DECAY-DATA (80-HG-206,8.15MIN) O073100200005 METHOD (STTA) O073100200006 (ACTIV) The Time Between the End of the Irradiation andO073100200007 The Start of the Measurements was 30 to 40 Min. O073100200008 (CHSEP) O073100200009 FACILITY (SYNCY,2ZZZCER) At 590 MeV. O073100200010 (SYNCH,2ZZZCER) At 19-GeV. O073100200011 MONITOR ((MONIT)13-AL-27(P,N+3P)11-NA-24,CUM,SIG) O073100200012 MONIT-REF (B0094001,K.GOEBEL+,J,NP,24,28,1961) O073100200013 ANALYSIS (DECAY) O073100200014 DETECTOR (PROPC).A Proportional Gas-Flow Counter. O073100200015 (NAICR).For Na-24 Activity. O073100200016 ERR-ANALYS (ERR-T).The Uncertainty is Reported by Authors. O073100200017 ENDBIB 15 0 O073100200018 NOCOMMON 0 0 O073100200019 DATA 4 2 O073100200020 EN DATA ERR-T MONIT O073100200021 GEV MICRO-B MICRO-B MB O073100200022 0.59 600. 180. 11. O073100200023 19. 260. 80. 8.6 O073100200024 ENDDATA 4 0 O073100200025 ENDSUBENT 24 0 O073100299999 ENDENTRY 2 0 O073199999999