ENTRY O0725 20021204 0000O072500000001 SUBENT O0725001 20021204 0000O072500100001 BIB 11 33 O072500100002 TITLE New targets for on-line mass separation of nuclei O072500100003 formed in 600 MeV proton and 910 MeV He-3 reactions. O072500100004 AUTHOR (T.Bjornstad, L.C.Carraz, H.A.Gustafsson, J.Heinemeier,O072500100005 B.Jonson, O.C.Jonsson, V.Lindfors, S.Mattsson, O072500100006 H.L.Ravn) O072500100007 INSTITUTE (2NOROSL) O072500100008 (2ZZZCER) O072500100009 (2DENAAU) O072500100010 REFERENCE (J,NIM,186,391,1981) O072500100011 REL-REF (N,,H.L.RAVN,J,NIM/B,26,72,1987) O072500100012 (N,O0515001,T.BJORNSTAD+,J,ZP/A,303,227,1981) O072500100013 HISTORY (20000315C) O072500100014 (20021204U) Last checking has been done. O072500100015 COMMENT -By authors:. The production yield is defined here as O072500100016 the measured intensity of the mass-separated beams in O072500100017 the collector tank. The yields were determined by O072500100018 in-beam beta-decay measurements at saturation for the O072500100019 very short-lived products. For the long-lived products,O072500100020 collection ans successive singles counting or O072500100021 multiscaling of the beta activity were used in order toO072500100022 determine the correct component from the complex decay O072500100023 curves. The most abundant radioactive ion beams were O072500100024 measured directly in a faraday cup. In order to averageO072500100025 short-time variation in the bombarding particle flux O072500100026 and in the separation and detector efficiency, it was O072500100027 found necessary to determine the intensity ratio O072500100028 between two adjacent masses rather than the absolute O072500100029 value. See entry o0515. O072500100030 FACILITY (SYNCY,2ZZZCER) O072500100031 METHOD (ASEP) O072500100032 (SITA) O072500100033 ERR-ANALYS (DATA-ERR).Data-point reader uncertainty. O072500100034 STATUS (CURVE).By CAJAD. O072500100035 ENDBIB 33 0 O072500100036 NOCOMMON 0 0 O072500100037 ENDSUBENT 36 0 O072500199999 SUBENT O0725002 20021204 0000O072500200001 BIB 4 9 O072500200002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 1 O072500200003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500200004 used. O072500200005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500200006 particle. It was used for mass=8. O072500200007 (PROPC) The delayed neutrons were measured with eight O072500200008 He-3 proportional counter tubes embedded symmetricallyO072500200009 in paraffin-wax. It was used for masses 9 and 11. O072500200010 FLAG (1.) The yield of mass=7 was measured by ion O072500200011 ENDBIB 9 0 O072500200012 COMMON 3 3 O072500200013 EN DATA-ERR ELEMENT O072500200014 MEV PER-CENT NO-DIM O072500200015 600. 5. 3. O072500200016 ENDCOMMON 3 0 O072500200017 DATA 3 4 O072500200018 MASS DATA FLAG O072500200019 NO-DIM ARB-UNITS NO-DIM O072500200020 7. 8.72E+09 1. O072500200021 8. 1.E+07 O072500200022 9. 8.77E+05 O072500200023 11. 4.04E+03 O072500200024 ENDDATA 6 0 O072500200025 ENDSUBENT 24 0 O072500299999 SUBENT O0725003 20021204 0000O072500300001 BIB 4 11 O072500300002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 1 O072500300003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500300004 used. O072500300005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500300006 particle. It was used for mass=8. O072500300007 (PROPC) The delayed neutrons were measured with eight O072500300008 He-3 proportional counter tubes embedded symmetricallyO072500300009 in paraffin-wax. It was used for masses 9 and 11. O072500300010 COMMENT - By authors - for the fragmentation product there is aO072500300011 trend towards higher production yields with He-3 than O072500300012 with protons. O072500300013 ENDBIB 11 0 O072500300014 COMMON 3 3 O072500300015 EN DATA-ERR ELEMENT O072500300016 MEV PER-CENT NO-DIM O072500300017 910. 5. 3. O072500300018 ENDCOMMON 3 0 O072500300019 DATA 2 3 O072500300020 MASS DATA O072500300021 NO-DIM ARB-UNITS O072500300022 8. 8.7E+07 O072500300023 9. 6.3E+06 O072500300024 11. 5.7E+02 O072500300025 ENDDATA 5 0 O072500300026 ENDSUBENT 25 0 O072500399999 SUBENT O0725004 20021204 0000O072500400001 BIB 5 18 O072500400002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure2. O072500400003 The P(N) values used are based on the new value for O072500400004 Li-9 of (50+-4)%. See rel-ref. O072500400005 REL-REF (R,,T.BJORNSTAD+,J,NP/A,359,1,1981) O072500400006 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500400007 used. O072500400008 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500400009 particle. It was used to measure yield of masses =20,O072500400010 21, and 25-27. O072500400011 (GELI).A 17% Ge(Li) standard efficiency detector. O072500400012 It was used to measure mass=24. O072500400013 (PROPC) The delayed neutrons were measured with eight O072500400014 He-3 proportional counter tubes embedded symmetricallyO072500400015 in paraffin-wax. It was used to measure yield of O072500400016 masses 27-32 O072500400017 COMMENT - By authors - for the fragmentation product there is aO072500400018 trend towards higher production yields with He-3 than O072500400019 with protons. O072500400020 ENDBIB 18 0 O072500400021 COMMON 3 3 O072500400022 EN DATA-ERR ELEMENT O072500400023 MEV PER-CENT NO-DIM O072500400024 600. 6. 11. O072500400025 ENDCOMMON 3 0 O072500400026 DATA 2 10 O072500400027 MASS DATA O072500400028 NO-DIM ARB-UNITS O072500400029 21. 1.07E+04 O072500400030 24. 6.2E+06 O072500400031 25. 6.5E+06 O072500400032 26. 1.26E+06 O072500400033 27. 3.1E+05 O072500400034 28. 1.23E+04 O072500400035 29. 4600. O072500400036 30. 640. O072500400037 31. 68. O072500400038 32. 6.9 O072500400039 ENDDATA 12 0 O072500400040 ENDSUBENT 39 0 O072500499999 SUBENT O0725005 20021204 0000O072500500001 BIB 5 18 O072500500002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure2 O072500500003 the P(N) values used are based on the new value for O072500500004 Li-9 of (50+-4)%. See rel-ref. O072500500005 REL-REF (R,,T.BJORNSTAD+,J,NP/A,359,1,1981) O072500500006 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500500007 used. O072500500008 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500500009 particle. It was used to measure yield of masses =20,O072500500010 21, and 25-27. O072500500011 (GELI).A 17% Ge(Li) standard efficiency detector. O072500500012 It was used to measure mass=24. O072500500013 (PROPC) The delayed neutrons were measured with eight O072500500014 He-3 proportional counter tubes embedded symmetricallyO072500500015 in paraffin-wax. It was used to measure yield of O072500500016 masses 27-32 O072500500017 COMMENT - By authors - for the fragmentation product there is aO072500500018 trend towards higher production yields with He-3 than O072500500019 with protons. O072500500020 ENDBIB 18 0 O072500500021 COMMON 3 3 O072500500022 EN DATA-ERR ELEMENT O072500500023 MEV PER-CENT NO-DIM O072500500024 910. 5. 11. O072500500025 ENDCOMMON 3 0 O072500500026 DATA 2 9 O072500500027 MASS DATA O072500500028 NO-DIM ARB-UNITS O072500500029 21. 4.8E+04 O072500500030 24. 1.66E+07 O072500500031 25. 1.91E+07 O072500500032 26. 4.27E+06 O072500500033 27. 1.32E+06 O072500500034 28. 1.77E+05 O072500500035 29. 5.8E+04 O072500500036 30. 6700. O072500500037 31. 980. O072500500038 ENDDATA 11 0 O072500500039 ENDSUBENT 38 0 O072500599999 SUBENT O0725006 20021204 0000O072500600001 BIB 3 12 O072500600002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure3 O072500600003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500600004 used. O072500600005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500600006 particle. It was used to measure yield of masses =37,O072500600007 38, and 44-50. O072500600008 (GELI).A 17% Ge(Li) standard efficiency detector. O072500600009 It was used to measure mass=42 and 43. O072500600010 (PROPC) The delayed neutrons were measured with eight O072500600011 He-3 proportional counter tubes embedded symmetricallyO072500600012 in paraffin-wax. It was used to measure yield of O072500600013 masses >49. O072500600014 ENDBIB 12 0 O072500600015 COMMON 3 3 O072500600016 EN DATA-ERR ELEMENT O072500600017 MEV PER-CENT NO-DIM O072500600018 600. 6. 19. O072500600019 ENDCOMMON 3 0 O072500600020 DATA 2 13 O072500600021 MASS DATA O072500600022 NO-DIM ARB-UNITS O072500600023 37. 289. O072500600024 38. 2.63E+04 O072500600025 42. 1.6E+07 O072500600026 43. 2.3E+07 O072500600027 44. 1.69E+07 O072500600028 45. 1.14E+07 O072500600029 46. 5.E+06 O072500600030 47. 1.48E+06 O072500600031 48. 2.61E+05 O072500600032 49. 2.48E+04 O072500600033 50. 1400. O072500600034 51. 284. O072500600035 52. 6.2 O072500600036 ENDDATA 15 0 O072500600037 ENDSUBENT 36 0 O072500699999 SUBENT O0725007 20021204 0000O072500700001 BIB 3 12 O072500700002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure3 O072500700003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072500700004 used. O072500700005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500700006 particle. It was used to measure yield of masses =37,O072500700007 38, and 44-50. O072500700008 (GELI).A 17% Ge(Li) standard efficiency detector. O072500700009 It was used to measure mass=42 and 43. O072500700010 (PROPC) The delayed neutrons were measured with eight O072500700011 He-3 proportional counter tubes embedded symmetricallyO072500700012 in paraffin-wax. It was used to measure yield of O072500700013 masses >49. O072500700014 ENDBIB 12 0 O072500700015 COMMON 3 3 O072500700016 EN DATA-ERR ELEMENT O072500700017 MEV PER-CENT NO-DIM O072500700018 910. 6. 19. O072500700019 ENDCOMMON 3 0 O072500700020 DATA 2 10 O072500700021 MASS DATA O072500700022 NO-DIM ARB-UNITS O072500700023 42. 1.6E+07 O072500700024 43. 2.09E+07 O072500700025 44. 1.7E+07 O072500700026 45. 1.14E+07 O072500700027 46. 4.3E+06 O072500700028 47. 1.48E+06 O072500700029 48. 2.16E+05 O072500700030 49. 4.2E+04 O072500700031 50. 7100. O072500700032 51. 1510. O072500700033 ENDDATA 12 0 O072500700034 ENDSUBENT 33 0 O072500799999 SUBENT O0725008 20021204 0000O072500800001 BIB 4 13 O072500800002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure4 O072500800003 the P(N) values for mass <=98 are all normalized O072500800004 to new P(N) value of Li-9 (see rel-ref) while those forO072500800005 a=99,100 and 102 are estimated. O072500800006 REL-REF (R,,T.BJORNSTAD+,J,NP/A,359,1,1981) O072500800007 SAMPLE UC2 -graphite cloth target, 16.4 g/cm**2 uranium, wasoO072500800008 used. O072500800009 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500800010 particle. It was used to measure masses =79, 81, 86 O072500800011 and 90-94. O072500800012 (PROPC) The delayed neutrons were measured with eight O072500800013 He-3 proportional counter tubes embedded symmetricallyO072500800014 in paraffin-wax. It was used to measure masses >94. O072500800015 ENDBIB 13 0 O072500800016 COMMON 3 3 O072500800017 EN DATA-ERR ELEMENT O072500800018 MEV PER-CENT NO-DIM O072500800019 600. 5. 37. O072500800020 ENDCOMMON 3 0 O072500800021 DATA 2 15 O072500800022 MASS DATA O072500800023 NO-DIM ARB-UNITS O072500800024 79. 3.44E+06 O072500800025 81. 6.7E+07 O072500800026 86. 1.78E+09 O072500800027 90. 4.6E+09 O072500800028 91. 2.58E+09 O072500800029 92. 1.83E+09 O072500800030 93. 1.64E+09 O072500800031 94. 7.6E+08 O072500800032 95. 3.67E+08 O072500800033 96. 1.1E+08 O072500800034 97. 5.3E+07 O072500800035 98. 2.83E+07 O072500800036 99. 3.97E+06 O072500800037 100. 2.25E+05 O072500800038 102. 2740. O072500800039 ENDDATA 17 0 O072500800040 ENDSUBENT 39 0 O072500899999 SUBENT O0725009 20021204 0000O072500900001 BIB 4 13 O072500900002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 4 O072500900003 the P(N) values for A<=98 are all normalized O072500900004 to new P(N) value of Li-9 (see rel-ref) while those forO072500900005 a=99,100 and 102 are estimated. O072500900006 REL-REF (R,,T.BJORNSTAD+,J,NP/A,359,1,1981) O072500900007 SAMPLE UC2 -graphite cloth target, 16.4 g/cm**2 uranium, wasoO072500900008 used. O072500900009 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072500900010 particle. It was used to measure masses =79, 81, 86 O072500900011 and 90-94. O072500900012 (PROPC) The delayed neutrons were measured with eight O072500900013 He-3 proportional counter tubes embedded symmetricallyO072500900014 in paraffin-wax. It was used to measure masses >94. O072500900015 ENDBIB 13 0 O072500900016 COMMON 3 3 O072500900017 EN DATA-ERR ELEMENT O072500900018 MEV PER-CENT NO-DIM O072500900019 910. 6. 37. O072500900020 ENDCOMMON 3 0 O072500900021 DATA 2 4 O072500900022 MASS DATA O072500900023 NO-DIM ARB-UNITS O072500900024 91. 1.39E+09 O072500900025 92. 1.38E+09 O072500900026 93. 7.7E+08 O072500900027 94. 3.37E+08 O072500900028 ENDDATA 6 0 O072500900029 ENDSUBENT 28 0 O072500999999 SUBENT O0725010 20021204 0000O072501000001 BIB 3 15 O072501000002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 5 O072501000003 the P(N) values are estimated and the yield normalized O072501000004 to the beta measurement at A=146. O072501000005 SAMPLE UC2 -graphite cloth target, 16.4 g/cm**2 uranium, wasoO072501000006 used. O072501000007 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501000008 particle. It was used to measure yield of masses 123, O072501000009 125, and 140-146. O072501000010 (GELI).A 17% Ge(Li) standard efficiency detector. O072501000011 The detector was used to measure yield of masses 127, O072501000012 129, 132, O072501000013 (PROPC) The delayed neutrons were measured with eight O072501000014 He-3 proportional counter tubes embedded symmetricallyO072501000015 in paraffin-wax. It was used to measure yield masses O072501000016 146-152. O072501000017 ENDBIB 15 0 O072501000018 COMMON 3 3 O072501000019 EN DATA-ERR ELEMENT O072501000020 MEV PER-CENT NO-DIM O072501000021 600. 6. 55. O072501000022 ENDCOMMON 3 0 O072501000023 DATA 2 18 O072501000024 MASS DATA O072501000025 NO-DIM ARB-UNITS O072501000026 123. 5.8E+07 O072501000027 125. 4.2E+08 O072501000028 127. 1.41E+09 O072501000029 129. 2.38E+09 O072501000030 132. 6.72E+09 O072501000031 140. 1.57E+09 O072501000032 141. 1.49E+09 O072501000033 142. 5.E+08 O072501000034 143. 4.2E+08 O072501000035 144. 1.66E+08 O072501000036 145. 5.8E+07 O072501000037 146. 4.07E+06 O072501000038 147. 1.23E+06 O072501000039 148. 2.56E+05 O072501000040 149. 7.3E+04 O072501000041 150. 1.18E+04 O072501000042 151. 1790. O072501000043 152. 222. O072501000044 ENDDATA 20 0 O072501000045 ENDSUBENT 44 0 O072501099999 SUBENT O0725011 20021204 0000O072501100001 BIB 3 15 O072501100002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 5 O072501100003 the P(N) values are estimated and the yield normalized O072501100004 to the beta measurement at A=146. O072501100005 SAMPLE UC2 -graphite cloth target, 16.4 g/cm**2 uranium, wasoO072501100006 used. O072501100007 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501100008 particle. It was used to measure yield of masses 123, O072501100009 125, and 140-146. O072501100010 (GELI).A 17% Ge(Li) standard efficiency detector. O072501100011 The detector was used to measure yield of masses 127, O072501100012 129, 132, O072501100013 (PROPC) The delayed neutrons were measured with eight O072501100014 He-3 proportional counter tubes embedded symmetricallyO072501100015 in paraffin-wax. It was used to measure yield masses O072501100016 146-152. O072501100017 ENDBIB 15 0 O072501100018 COMMON 3 3 O072501100019 EN DATA-ERR ELEMENT O072501100020 MEV PER-CENT NO-DIM O072501100021 910. 6. 55. O072501100022 ENDCOMMON 3 0 O072501100023 DATA 2 7 O072501100024 MASS DATA O072501100025 NO-DIM ARB-UNITS O072501100026 142. 3.27E+08 O072501100027 143. 1.75E+08 O072501100028 144. 4.05E+07 O072501100029 145. 2.28E+07 O072501100030 146. 2.98E+06 O072501100031 147. 5.9E+05 O072501100032 148. 1.44E+05 O072501100033 ENDDATA 9 0 O072501100034 ENDSUBENT 33 0 O072501199999 SUBENT O0725012 20021204 0000O072501200001 BIB 3 8 O072501200002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 6 O072501200003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072501200004 used. O072501200005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501200006 particle. It was used to measure yield of masses >222O072501200007 (SIBAR).Silicon surface barrier detectors for the O072501200008 detection of alpha-particles. It was used to measure O072501200009 yield of masses 202-213 and 219-221. O072501200010 ENDBIB 8 0 O072501200011 COMMON 3 3 O072501200012 EN DATA-ERR ELEMENT O072501200013 MEV PER-CENT NO-DIM O072501200014 600. 6. 87. O072501200015 ENDCOMMON 3 0 O072501200016 DATA 2 22 O072501200017 MASS DATA O072501200018 NO-DIM ARB-UNITS O072501200019 202. 35.2 O072501200020 203. 570. O072501200021 204. 2.48E+04 O072501200022 205. 2.81E+05 O072501200023 206. 2.9E+06 O072501200024 207. 8.9E+06 O072501200025 208. 2.61E+07 O072501200026 209. 4.47E+07 O072501200027 210. 8.4E+07 O072501200028 211. 1.14E+08 O072501200029 212. 1.14E+08 O072501200030 213. 6.9E+07 O072501200031 219. 2.58E+05 O072501200032 220. 1.03E+07 O072501200033 221. 2.01E+07 O072501200034 222. 7.5E+06 O072501200035 224. 1.68E+06 O072501200036 225. 1.4E+06 O072501200037 226. 3.17E+05 O072501200038 228. 7.1E+04 O072501200039 229. 2.12E+04 O072501200040 230. 4370. O072501200041 ENDDATA 24 0 O072501200042 ENDSUBENT 41 0 O072501299999 SUBENT O0725013 20021204 0000O072501300001 BIB 3 8 O072501300002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 6. O072501300003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072501300004 used. O072501300005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501300006 particle. It was used to measure yield of masses >222O072501300007 (SIBAR).Silicon surface barrier detectors for the O072501300008 detection of alpha-particles. It was used to measure O072501300009 yield of masses 202-213 and 219-221. O072501300010 ENDBIB 8 0 O072501300011 COMMON 3 3 O072501300012 EN DATA-ERR ELEMENT O072501300013 MEV PER-CENT NO-DIM O072501300014 910. 6. 87. O072501300015 ENDCOMMON 3 0 O072501300016 DATA 2 16 O072501300017 MASS DATA O072501300018 NO-DIM ARB-UNITS O072501300019 202. 465. O072501300020 203. 3940. O072501300021 204. 8.E+04 O072501300022 205. 6.6E+05 O072501300023 206. 2.77E+06 O072501300024 207. 1.33E+07 O072501300025 208. 2.73E+07 O072501300026 209. 3.41E+07 O072501300027 210. 7.E+07 O072501300028 211. 6.7E+07 O072501300029 212. 5.1E+07 O072501300030 213. 8.7E+07 O072501300031 220. 3.82E+06 O072501300032 224. 7.5E+05 O072501300033 225. 8.5E+05 O072501300034 226. 2.11E+05 O072501300035 ENDDATA 18 0 O072501300036 ENDSUBENT 35 0 O072501399999 SUBENT O0725014 20021204 0000O072501400001 BIB 2 3 O072501400002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 8. O072501400003 SAMPLE UC2 -graphite cloth target, 15.1 g/cm**2 uranium, wasoO072501400004 used. O072501400005 ENDBIB 3 0 O072501400006 COMMON 3 3 O072501400007 EN DATA-ERR ELEMENT O072501400008 MEV PER-CENT NO-DIM O072501400009 600. 2. 31. O072501400010 ENDCOMMON 3 0 O072501400011 DATA 2 3 O072501400012 MASS DATA O072501400013 NO-DIM ARB-UNITS O072501400014 76. 1.71E+07 O072501400015 77. 1.023E+07 O072501400016 78. 4.51E+06 O072501400017 ENDDATA 5 0 O072501400018 ENDSUBENT 17 0 O072501499999 SUBENT O0725015 20021204 0000O072501500001 BIB 3 9 O072501500002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 10 O072501500003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072501500004 used. O072501500005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501500006 particle. It was used to measure yield of masses >= O072501500007 185. O072501500008 (SIBAR).Silicon surface barrier detectors for the O072501500009 detection of alpha-particles. It was used to measure O072501500010 yield of masses 184-186. O072501500011 ENDBIB 9 0 O072501500012 COMMON 3 3 O072501500013 EN ELEMENT DATA-ERR O072501500014 MEV NO-DIM PER-CENT O072501500015 600. 81. 6. O072501500016 ENDCOMMON 3 0 O072501500017 DATA 3 9 O072501500018 MASS DATA ISOMER O072501500019 NO-DIM ARB-UNITS NO-DIM O072501500020 184. 407. O072501500021 185. 1490. 1. O072501500022 186. 6000. 0. O072501500023 187. 2.52E+04 1. O072501500024 188. 1.01E+05 0. O072501500025 191. 3.01E+05 0. O072501500026 193. 1.48E+05 1. O072501500027 195. 5.3E+04 1. O072501500028 197. 2.25E+04 1. O072501500029 ENDDATA 11 0 O072501500030 ENDSUBENT 29 0 O072501599999 SUBENT O0725016 20021204 0000O072501600001 BIB 3 9 O072501600002 REACTION (92-U-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 10 O072501600003 SAMPLE UC2 -graphite cloth target, 10.0 g/cm**2 uranium, wasoO072501600004 used. O072501600005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501600006 particle. It was used to measure yield of masses >= O072501600007 185. O072501600008 (SIBAR).Silicon surface barrier detectors for the O072501600009 detection of alpha-particles. It was used to measure O072501600010 yield of masses 184-186. O072501600011 ENDBIB 9 0 O072501600012 COMMON 3 3 O072501600013 EN ELEMENT DATA-ERR O072501600014 MEV NO-DIM PER-CENT O072501600015 910. 81. 6. O072501600016 ENDCOMMON 3 0 O072501600017 DATA 3 10 O072501600018 MASS DATA ISOMER O072501600019 NO-DIM ARB-UNITS NO-DIM O072501600020 184. 2.79E+04 O072501600021 185. 3.39E+04 1. O072501600022 186. 3.42E+05 0. O072501600023 187. 2.63E+05 1. O072501600024 188. 8.E+05 0. O072501600025 190. 1.24E+06 1. O072501600026 191. 6.9E+05 0. O072501600027 193. 3.23E+05 1. O072501600028 195. 1.05E+05 1. O072501600029 197. 3.9E+04 1. O072501600030 ENDDATA 12 0 O072501600031 ENDSUBENT 30 0 O072501699999 SUBENT O0725017 20021204 0000O072501700001 BIB 5 10 O072501700002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure9 O072501700003 low spin isomer yields were measured. O072501700004 SAMPLE UC2 -graphite cloth target, 15.1 g/cm**2 uranium, wasoO072501700005 used. O072501700006 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501700007 particle. O072501700008 MISC-COL (MISC) The half-life has been included from ENSDF by O072501700009 compiler O072501700010 COMMENT - By compiler - the values of half-lives and spins are O072501700011 included by compiler from ENSDF. O072501700012 ENDBIB 10 0 O072501700013 COMMON 3 3 O072501700014 EN DATA-ERR ELEMENT O072501700015 MEV PER-CENT NO-DIM O072501700016 600. 6. 49. O072501700017 ENDCOMMON 3 0 O072501700018 DATA 4 6 O072501700019 MASS DATA SPIN J MISC O072501700020 NO-DIM ARB-UNITS NO-DIM SEC O072501700021 116. 9.7E+06 +1. 14.1 O072501700022 118. 2.68E+07 +1. 5. O072501700023 120. 1.35E+07 +1. 3.08 O072501700024 121. 3.17E+07 -0.5 232.8 O072501700025 122. 1.22E+07 +1. 1.5 O072501700026 128. 4.26E+06 +3. 0.84 O072501700027 ENDDATA 8 0 O072501700028 ENDSUBENT 27 0 O072501799999 SUBENT O0725018 20021204 0000O072501800001 BIB 6 14 O072501800002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 9 O072501800003 high spin isomer yields were measured. O072501800004 SAMPLE UC2 -graphite cloth target, 15.1 g/cm**2 uranium, wasoO072501800005 used. O072501800006 MISC-COL (MISC) The half-life has been included from ENSDF by O072501800007 compiler O072501800008 COMMENT - By compiler - the values of half-lives and spins are O072501800009 included by compiler from ENSDF. O072501800010 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501800011 particle. O072501800012 FLAG (1.) >=2 high spin isomers are known for the nuclide. O072501800013 It is unknown which isomer was used for yield O072501800014 measurements. O072501800015 (2.) Exact value of spin-parity is unknown. O072501800016 ENDBIB 14 0 O072501800017 COMMON 3 3 O072501800018 EN DATA-ERR ELEMENT O072501800019 MEV PER-CENT NO-DIM O072501800020 600. 6. 49. O072501800021 ENDCOMMON 3 0 O072501800022 DATA 5 12 O072501800023 MASS DATA SPIN J MISC FLAG O072501800024 NO-DIM ARB-UNITS NO-DIM SEC NO-DIM O072501800025 114. 5.48E+06 +5. 4.278E+06 1. O072501800026 116. 1.23E+08 1. O072501800027 117. 3.23E+08 +4.5 2592. O072501800028 118. 5.02E+08 1. O072501800029 119. 7.8E+08 +4.5 144. O072501800030 120. 5.62E+08 1. O072501800031 121. 4.35E+08 +4.5 23.1 O072501800032 122. 2.06E+08 1. O072501800033 124. 1.23E+08 -8. 3.4 O072501800034 126. 3.8E+07 1.64 2. O072501800035 128. 1.55E+07 1. O072501800036 130. 2.46E+06 1. O072501800037 ENDDATA 14 0 O072501800038 ENDSUBENT 37 0 O072501899999 SUBENT O0725019 20021204 0000O072501900001 BIB 3 5 O072501900002 REACTION (92-U-0(P,F)ELEM/MASS,,PY,,REL) Figure 9 O072501900003 SAMPLE UC2 -graphite cloth target, 15.1 g/cm**2 uranium, wasoO072501900004 used. O072501900005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072501900006 particle. O072501900007 ENDBIB 5 0 O072501900008 COMMON 3 3 O072501900009 EN DATA-ERR ELEMENT O072501900010 MEV PER-CENT NO-DIM O072501900011 600. 6. 47. O072501900012 ENDCOMMON 3 0 O072501900013 DATA 2 3 O072501900014 MASS DATA O072501900015 NO-DIM ARB-UNITS O072501900016 110. 1.65E+04 O072501900017 111. 1.51E+05 O072501900018 114. 9.6E+05 O072501900019 ENDDATA 5 0 O072501900020 ENDSUBENT 19 0 O072501999999 SUBENT O0725020 20021204 0000O072502000001 BIB 3 8 O072502000002 REACTION (90-TH-232(P,F)ELEM/MASS,,PY,,REL) Figure 12 O072502000003 SAMPLE ThC2 -graphite target, 12.4 g/cm**2 thorium, was usedoO072502000004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502000005 particle. It was used to measure yield of masses >= O072502000006 185. O072502000007 (SIBAR).Silicon surface barrier detectors for the O072502000008 detection of alpha-particles. It was used to measure O072502000009 yield of masses 184-186. O072502000010 ENDBIB 8 0 O072502000011 COMMON 3 3 O072502000012 EN DATA-ERR ELEMENT O072502000013 MEV PER-CENT NO-DIM O072502000014 600. 6. 81. O072502000015 ENDCOMMON 3 0 O072502000016 DATA 2 8 O072502000017 MASS DATA O072502000018 NO-DIM ARB-UNITS O072502000019 185. 2240. O072502000020 186. 2.87E+04 O072502000021 187. 3.42E+04 O072502000022 188. 1.34E+05 O072502000023 190. 4.52E+05 O072502000024 191. 4.65E+05 O072502000025 197. 1.87E+06 O072502000026 199. 9.1E+05 O072502000027 ENDDATA 10 0 O072502000028 ENDSUBENT 27 0 O072502099999 SUBENT O0725021 20021204 0000O072502100001 BIB 3 8 O072502100002 REACTION (90-TH-232(HE3,F)ELEM/MASS,,PY,,REL) Figure 12 O072502100003 SAMPLE ThC2 -graphite target, 12.4 g/cm**2 thorium, was usedoO072502100004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502100005 particle. It was used to measure yield of masses >= O072502100006 185. O072502100007 (SIBAR).Silicon surface barrier detectors for the O072502100008 detection of alpha-particles. It was used to measure O072502100009 yield of masses 184-186. O072502100010 ENDBIB 8 0 O072502100011 COMMON 3 3 O072502100012 EN DATA-ERR ELEMENT O072502100013 MEV PER-CENT NO-DIM O072502100014 910. 6. 81. O072502100015 ENDCOMMON 3 0 O072502100016 DATA 2 11 O072502100017 MASS DATA O072502100018 NO-DIM ARB-UNITS O072502100019 184. 1.E+05 O072502100020 185. 2.92E+05 O072502100021 186. 2.16E+06 O072502100022 187. 1.87E+06 O072502100023 188. 6.51E+06 O072502100024 189. 9.8E+06 O072502100025 190. 1.42E+07 O072502100026 191. 1.65E+07 O072502100027 192. 2.47E+07 O072502100028 194. 5.57E+07 O072502100029 195. 1.47E+07 O072502100030 ENDDATA 13 0 O072502100031 ENDSUBENT 30 0 O072502199999 SUBENT O0725022 20021204 0000O072502200001 BIB 3 8 O072502200002 REACTION (90-TH-232(P,F)ELEM/MASS,,PY,,REL) Figure 13 O072502200003 SAMPLE ThC2 -graphite target, 12.4 g/cm**2 thorium, was usedoO072502200004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502200005 particle. It was used to measure yield of masses >= O072502200006 222. O072502200007 (SIBAR).Silicon surface barrier detectors for the O072502200008 detection of alpha-particles. It was used to measure O072502200009 yield of masses 202-213 and 219-221. O072502200010 ENDBIB 8 0 O072502200011 COMMON 3 3 O072502200012 EN DATA-ERR ELEMENT O072502200013 MEV PER-CENT NO-DIM O072502200014 600. 6. 87. O072502200015 ENDCOMMON 3 0 O072502200016 DATA 2 10 O072502200017 MASS DATA O072502200018 NO-DIM ARB-UNITS O072502200019 207. 1.61E+07 O072502200020 208. 6.6E+07 O072502200021 211. 3.37E+08 O072502200022 213. 2.76E+08 O072502200023 220. 1.44E+08 O072502200024 221. 2.31E+08 O072502200025 222. 8.3E+07 O072502200026 224. 1.36E+07 O072502200027 226. 2.58E+06 O072502200028 228. 3.96E+05 O072502200029 ENDDATA 12 0 O072502200030 ENDSUBENT 29 0 O072502299999 SUBENT O0725023 20021204 0000O072502300001 BIB 3 8 O072502300002 REACTION (23-V-51(P,X)ELEM/MASS,,PY,,REL) Figure 15 O072502300003 SAMPLE Pure vanadium carbide powder was compressed into O072502300004 tablets and loaded into a graphite-lined Ta target O072502300005 container.(54.3 g/cm**2 vanadium). O072502300006 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502300007 particle. It was used to measure yield of masses >32.O072502300008 (SIBAR).Silicon surface barrier detectors for the O072502300009 detection of delayed protons from mass 32. O072502300010 ENDBIB 8 0 O072502300011 COMMON 3 3 O072502300012 EN DATA-ERR ELEMENT O072502300013 MEV PER-CENT NO-DIM O072502300014 600. 6. 18. O072502300015 ENDCOMMON 3 0 O072502300016 DATA 2 9 O072502300017 MASS DATA O072502300018 NO-DIM ARB-UNITS O072502300019 32. 0.344 O072502300020 33. 19.6 O072502300021 34. 1.08E+04 O072502300022 35. 2.92E+05 O072502300023 41. 1.44E+08 O072502300024 43. 2.96E+06 O072502300025 44. 3.71E+05 O072502300026 45. 1.78E+04 O072502300027 46. 1320. O072502300028 ENDDATA 11 0 O072502300029 ENDSUBENT 28 0 O072502399999 SUBENT O0725024 20021204 0000O072502400001 BIB 3 8 O072502400002 REACTION (23-V-51(HE3,F)ELEM/MASS,,PY,,REL) Figure 15 O072502400003 SAMPLE Pure vanadium carbide powder was compressed into O072502400004 tablets and loaded into a graphite-lined Ta target O072502400005 container.(54.3 g/cm**2 vanadium). O072502400006 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502400007 particle. It was used to measure yield of masses >32.O072502400008 (SIBAR).Silicon surface barrier detectors for the O072502400009 detection of delayed protons from mass 32. O072502400010 ENDBIB 8 0 O072502400011 COMMON 3 3 O072502400012 EN DATA-ERR ELEMENT O072502400013 MEV PER-CENT NO-DIM O072502400014 910. 6. 18. O072502400015 ENDCOMMON 3 0 O072502400016 DATA 2 8 O072502400017 MASS DATA O072502400018 NO-DIM ARB-UNITS O072502400019 33. 72. O072502400020 34. 2.17E+04 O072502400021 35. 9.1E+05 O072502400022 41. 4.06E+07 O072502400023 43. 1.83E+06 O072502400024 44. 2.73E+05 O072502400025 45. 1.37E+04 O072502400026 46. 1060. O072502400027 ENDDATA 10 0 O072502400028 ENDSUBENT 27 0 O072502499999 SUBENT O0725025 20021204 0000O072502500001 BIB 3 8 O072502500002 REACTION (20-CA-0(P,X)ELEM/MASS,,PY,,REL) O072502500003 SAMPLE Commercially available CaB6 powder was located into O072502500004 graphite-clad Ta target container and compressed O072502500005 manually to about 50% of the specific density of pure O072502500006 CaB6. The Ca Target Thickness Obtained was 7.5 O072502500007 g/cm**2. O072502500008 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502500009 particle. O072502500010 ENDBIB 8 0 O072502500011 COMMON 3 3 O072502500012 EN DATA-ERR ELEMENT O072502500013 MEV PER-CENT NO-DIM O072502500014 600. 6. 18. O072502500015 ENDCOMMON 3 0 O072502500016 DATA 2 2 O072502500017 MASS DATA O072502500018 NO-DIM ARB-UNITS O072502500019 34. 1.E+05 O072502500020 35. 1.68E+06 O072502500021 ENDDATA 4 0 O072502500022 ENDSUBENT 21 0 O072502599999 SUBENT O0725026 20021204 0000O072502600001 BIB 4 6 O072502600002 REACTION (21-SC-45(P,X)ELEM/MASS,,PY,,REL) Figure16 O072502600003 SAMPLE The ScC2 -graphite target was used. Sc-target O072502600004 thickness is 12.8 g/cm**2. O072502600005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502600006 particle. It was used to measure yield of masses >32.O072502600007 FLAG (2.).The yield was determined by in-beam beta detectionO072502600008 ENDBIB 6 0 O072502600009 COMMON 3 3 O072502600010 EN DATA-ERR ELEMENT O072502600011 MEV PER-CENT NO-DIM O072502600012 600. 6. 19. O072502600013 ENDCOMMON 3 0 O072502600014 DATA 3 4 O072502600015 MASS DATA FLAG O072502600016 NO-DIM ARB-UNITS NO-DIM O072502600017 35. 4700. 2. O072502600018 36. 3.27E+05 O072502600019 37. 1.54E+07 O072502600020 38. 8.9E+07 O072502600021 ENDDATA 6 0 O072502600022 ENDSUBENT 21 0 O072502699999 SUBENT O0725027 20021204 0000O072502700001 BIB 4 6 O072502700002 REACTION (21-SC-45(HE3,X)ELEM/MASS,,PY,,REL) Figure 16 O072502700003 SAMPLE The ScC2 -graphite target, thickness Sc is 12.8 g/ O072502700004 cm**2, was used. O072502700005 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502700006 particle. It was used to measure yield of masses >32.O072502700007 FLAG (2.).The yield was determined by in-beam beta detectionO072502700008 ENDBIB 6 0 O072502700009 COMMON 3 3 O072502700010 EN DATA-ERR ELEMENT O072502700011 MEV PER-CENT NO-DIM O072502700012 910. 6. 19. O072502700013 ENDCOMMON 3 0 O072502700014 DATA 3 4 O072502700015 MASS DATA FLAG O072502700016 NO-DIM ARB-UNITS NO-DIM O072502700017 35. 1.82E+04 2. O072502700018 36. 7.5E+05 O072502700019 37. 4.01E+07 O072502700020 38. 1.71E+08 O072502700021 ENDDATA 6 0 O072502700022 ENDSUBENT 21 0 O072502799999 SUBENT O0725028 20021204 0000O072502800001 BIB 4 10 O072502800002 REACTION (57-LA-139(P,X)ELEM/MASS,,PY,,REL) Figure 17 O072502800003 SAMPLE Molten lanthanum, thickness 140 g/cm**2, was used. O072502800004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502800005 particle. It was used to measure yield of masses O072502800006 116, 117. O072502800007 (SIBAR).Silicon surface barrier detectors for the O072502800008 detection of delayed protons. It was used to measure O072502800009 yield of masse 114. O072502800010 FLAG (2.).The yields were measured by means of the faraday O072502800011 cup. O072502800012 ENDBIB 10 0 O072502800013 COMMON 3 3 O072502800014 EN DATA-ERR ELEMENT O072502800015 MEV PER-CENT NO-DIM O072502800016 600. 6. 55. O072502800017 ENDCOMMON 3 0 O072502800018 DATA 3 23 O072502800019 MASS DATA FLAG O072502800020 NO-DIM ARB-UNITS NO-DIM O072502800021 114. 5.8 O072502800022 115. 202. O072502800023 116. 4240. O072502800024 117. 1.83E+05 O072502800025 118. 3.36E+06 2. O072502800026 119. 1.66E+08 2. O072502800027 120. 3.23E+08 2. O072502800028 121. 2.53E+09 2. O072502800029 122. 2.88E+09 2. O072502800030 123. 1.38E+10 2. O072502800031 124. 7.3E+09 2. O072502800032 125. 2.67E+10 2. O072502800033 126. 1.77E+10 2. O072502800034 127. 3.46E+10 2. O072502800035 128. 2.3E+10 2. O072502800036 129. 2.5E+10 2. O072502800037 130. 1.9E+10 2. O072502800038 131. 1.73E+10 2. O072502800039 132. 1.25E+10 2. O072502800040 134. 6.E+09 2. O072502800041 135. 4.39E+09 2. O072502800042 136. 2.33E+09 2. O072502800043 137. 8.6E+08 2. O072502800044 ENDDATA 25 0 O072502800045 ENDSUBENT 44 0 O072502899999 SUBENT O0725029 20021204 0000O072502900001 BIB 4 10 O072502900002 REACTION (57-LA-139(HE3,X)ELEM/MASS,,PY,,REL) Figure 17 O072502900003 SAMPLE Molten lanthanum, thickness 140 g/cm**2, was used. O072502900004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072502900005 particle. It was used to measure yield of masses O072502900006 116, 117. O072502900007 (SIBAR).Silicon surface barrier detectors for the O072502900008 detection of delayed protons. It was used to measure O072502900009 yield of mass 114. O072502900010 FLAG (2.).The yields were measured by means of the Faraday O072502900011 cup. O072502900012 ENDBIB 10 0 O072502900013 COMMON 3 3 O072502900014 EN DATA-ERR ELEMENT O072502900015 MEV PER-CENT NO-DIM O072502900016 910. 6. 55. O072502900017 ENDCOMMON 3 0 O072502900018 DATA 3 22 O072502900019 MASS DATA FLAG O072502900020 NO-DIM ARB-UNITS NO-DIM O072502900021 114. 8.4 O072502900022 116. 1.42E+04 O072502900023 117. 5.9E+05 O072502900024 118. 1.23E+07 2. O072502900025 119. 6.1E+08 2. O072502900026 120. 8.7E+08 2. O072502900027 121. 4.15E+09 2. O072502900028 122. 5.4E+09 2. O072502900029 123. 2.36E+10 2. O072502900030 124. 1.88E+10 2. O072502900031 125. 6.3E+10 2. O072502900032 126. 3.48E+10 2. O072502900033 127. 6.8E+10 2. O072502900034 128. 3.14E+10 2. O072502900035 129. 4.28E+10 2. O072502900036 130. 2.6E+10 2. O072502900037 131. 2.16E+10 2. O072502900038 132. 1.57E+10 2. O072502900039 133. 1.19E+10 2. O072502900040 134. 8.3E+09 2. O072502900041 135. 5.7E+09 2. O072502900042 136. 2.92E+09 2. O072502900043 ENDDATA 24 0 O072502900044 ENDSUBENT 43 0 O072502999999 SUBENT O0725030 20021204 0000O072503000001 BIB 3 8 O072503000002 REACTION (82-PB-0(P,F)ELEM/MASS,,PY,,REL) Figure 18 O072503000003 SAMPLE Molten lead, thickness 170 g/cm**2, was used. O072503000004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072503000005 particle. It was used to measure yield of masses O072503000006 186-205 O072503000007 (SIBAR).Silicon surface barrier detectors for the O072503000008 detection of alpha-particles. It was used to measure O072503000009 yield of masses 177-185. O072503000010 ENDBIB 8 0 O072503000011 COMMON 3 3 O072503000012 EN DATA-ERR ELEMENT O072503000013 MEV PER-CENT NO-DIM O072503000014 600. 6. 80. O072503000015 ENDCOMMON 3 0 O072503000016 DATA 2 28 O072503000017 MASS DATA O072503000018 NO-DIM ARB-UNITS O072503000019 177. 0.97 O072503000020 178. 43.4 O072503000021 179. 1690. O072503000022 180. 5.7E+04 O072503000023 181. 7.7E+05 O072503000024 182. 7.8E+06 O072503000025 183. 4.9E+07 O072503000026 184. 1.19E+08 O072503000027 185. 2.26E+08 O072503000028 186. 5.7E+08 O072503000029 187. 1.19E+09 O072503000030 188. 1.97E+09 O072503000031 189. 2.97E+09 O072503000032 190. 4.29E+09 O072503000033 191. 4.7E+09 O072503000034 192. 5.6E+09 O072503000035 193. 6.1E+09 O072503000036 194. 6.7E+09 O072503000037 195. 6.3E+09 O072503000038 196. 6.9E+09 O072503000039 197. 6.9E+09 O072503000040 198. 5.7E+09 O072503000041 199. 6.2E+09 O072503000042 200. 4.24E+09 O072503000043 201. 2.65E+09 O072503000044 202. 7.5E+08 O072503000045 203. 8.6E+08 O072503000046 205. 6.3E+07 O072503000047 ENDDATA 30 0 O072503000048 ENDSUBENT 47 0 O072503099999 SUBENT O0725031 20021204 0000O072503100001 BIB 3 8 O072503100002 REACTION (82-PB-0(HE3,F)ELEM/MASS,,PY,,REL) Figure 18. O072503100003 SAMPLE Molten lead,thickness 170 g/cm**2, was used. O072503100004 DETECTOR (D4PI).A 4-pi plastic scintillator to count beta- O072503100005 particle. It was used to measure yield of masses O072503100006 186-205 O072503100007 (SIBAR).Silicon surface barrier detectors for the O072503100008 detection of alpha-particles. It was used to measure O072503100009 yield of masses 177-185. O072503100010 ENDBIB 8 0 O072503100011 COMMON 3 3 O072503100012 EN DATA-ERR ELEMENT O072503100013 MEV PER-CENT NO-DIM O072503100014 910. 6. 80. O072503100015 ENDCOMMON 3 0 O072503100016 DATA 2 13 O072503100017 MASS DATA O072503100018 NO-DIM ARB-UNITS O072503100019 177. 4.29 O072503100020 178. 305. O072503100021 179. 5900. O072503100022 180. 8.3E+04 O072503100023 181. 3.82E+05 O072503100024 182. 4.7E+06 O072503100025 183. 9.3E+06 O072503100026 184. 2.95E+07 O072503100027 185. 1.13E+08 O072503100028 186. 3.41E+08 O072503100029 188. 1.93E+08 O072503100030 190. 9.3E+08 O072503100031 192. 3.36E+09 O072503100032 ENDDATA 15 0 O072503100033 ENDSUBENT 32 0 O072503199999 ENDENTRY 31 0 O072599999999