ENTRY O0512 19991117 0000O051200000001 SUBENT O0512001 19991117 0000O051200100001 BIB 12 29 O051200100002 TITLE Production of Thulium-167 For Medical Use by O051200100003 Irradiation of Lutetium,Hafnium,Tantalum and Tundsten O051200100004 With 590-MeV Protons. O051200100005 AUTHOR (K.L.SCHOLZ,V.J.SODD,J.W.BLUE) O051200100006 INSTITUTE (1USAUSA).Cincinnati General Hospital,Ohio,USA. O051200100007 (1USALRC) O051200100008 REFERENCE (J,ARI,27,263,1976) O051200100009 HISTORY (19990324C) O051200100010 (19990516U) Last checking has been done. O051200100011 (19991117A) DATE is corrected O051200100012 DETECTOR (GELI).A Ge(Li) Crystal 6 cm**2 in Area and 0.7-cm O051200100013 Thick. O051200100014 FACILITY (SYNCY,1USASRE) O051200100015 METHOD (ACTIV) O051200100016 (STTA) Targets were Irradiated in Stacks Which O051200100017 Degraded the Beam Energy by About 12 MeV. O051200100018 Except For Lutetium-Oxide Target, Each Target Material O051200100019 Was Irradiared As a Group of 3 Identical Foils. The O051200100020 First, Used to Negate Recoil Effects, was Discarded. O051200100021 (BCINT) O051200100022 (EXTB) The External Beam Current was About 10 O051200100023 Nanoampere. O051200100024 (CHSEP) O051200100025 ERR-ANALYS (ERR-T) The Errors Reported Consist of Uncertainty in O051200100026 Beam Current, Target Thickness and Detector Efficiency,O051200100027 Combined with Counting Error. O051200100028 STATUS (TABLE) Table 2. O051200100029 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,CUM,SIG) O051200100030 MONIT-REF (C0224001,J.B.CUMMING+,J,PR,128,2392,1962) O051200100031 ENDBIB 29 0 O051200100032 NOCOMMON 0 0 O051200100033 ENDSUBENT 32 0 O051200199999 SUBENT O0512002 19991117 0000O051200200001 BIB 5 13 O051200200002 REACTION 1(71-LU-0(P,X)69-TM-167,CUM,SIG) O051200200003 2(71-LU-0(P,X)69-TM-168,IND,SIG) O051200200004 RAD-DET (69-TM-167,DG) O051200200005 (69-TM-168,DG) O051200200006 DECAY-DATA (69-TM-167,9.6D,DG,208.,0.43,DG,532.,0.02) O051200200007 (69-TM-168,87.D,DG,184.,0.18,DG,198.,0.53,DG,447.,0.24,O051200200008 DG,720.,0.12,DG,741.,0.12,DG,816.,0.5,DG,821.,0.12) O051200200009 SAMPLE The Lutetium Oxide was in Powder Form and was ContainedO051200200010 In Aluminium Target Holders and Covered Aluminium Foil,O051200200011 The Lutetium Target Thickness was 310 mg/cm**2 and O051200200012 2.4 cm in Diameter. O051200200013 FLAG (1.).The Second Identical Foils. O051200200014 (2.).The Third Identical Foils. O051200200015 ENDBIB 13 0 O051200200016 NOCOMMON 0 0 O051200200017 DATA 7 2 O051200200018 EN DATA 1ERR-T 1DATA 2ERR-T 2MONIT O051200200019 FLAG O051200200020 MEV MB MB MB MB MB O051200200021 NO-DIM O051200200022 590. 54. 6. 5. 1.1 10.7O051200200023 1. O051200200024 590. 55. 6. 5. 0.9 10.7O051200200025 2. O051200200026 ENDDATA 8 0 O051200200027 ENDSUBENT 26 0 O051200299999 SUBENT O0512003 19991117 0000O051200300001 BIB 5 11 O051200300002 REACTION 1(72-HF-0(P,X)69-TM-167,CUM,SIG) O051200300003 2(72-HF-0(P,X)69-TM-168,IND,SIG) O051200300004 RAD-DET (69-TM-167,DG) O051200300005 (69-TM-168,DG) O051200300006 DECAY-DATA (69-TM-167,9.6D,DG,208.,0.43,DG,532.,0.02) O051200300007 (69-TM-168,87.D,DG,184.,0.18,DG,198.,0.53,DG,447.,0.24,O051200300008 DG,720.,0.12,DG,741.,0.12,DG,816.,0.5,DG,821.,0.12) O051200300009 SAMPLE The High-Purity Metal Foils of Hafnium,Thickness O051200300010 918 mg/cm**2,2.4 cm in Diameter,were Used. O051200300011 FLAG (1.).The Second Identical Foils. O051200300012 (2.).The Third Identical Foils. O051200300013 ENDBIB 11 0 O051200300014 NOCOMMON 0 0 O051200300015 DATA 7 2 O051200300016 EN DATA 1ERR-T 1DATA 2ERR-T 2MONIT O051200300017 FLAG O051200300018 MEV MB MB MB MB MB O051200300019 NO-DIM O051200300020 590. 37. 5. 5.6 2.8 10.7O051200300021 1. O051200300022 590. 65. 9. 6.3 1.9 10.7O051200300023 2. O051200300024 ENDDATA 8 0 O051200300025 ENDSUBENT 24 0 O051200399999 SUBENT O0512004 19991117 0000O051200400001 BIB 5 11 O051200400002 REACTION 1(73-TA-181(P,X)69-TM-167,CUM,SIG) O051200400003 2(73-TA-181(P,X)69-TM-168,IND,SIG) O051200400004 RAD-DET (69-TM-167,DG) O051200400005 (69-TM-168,DG) O051200400006 DECAY-DATA (69-TM-167,9.6D,DG,208.,0.43,DG,532.,0.02) O051200400007 (69-TM-168,87.D,DG,184.,0.18,DG,198.,0.53,DG,447.,0.24,O051200400008 DG,720.,0.12,DG,741.,0.12,DG,816.,0.5,DG,821.,0.12) O051200400009 SAMPLE The High-Purity Metal Foils of Tantalum, Thickness O051200400010 487 mg/cm**2,2.4 cm in Diameter, were Used. O051200400011 FLAG (1.).The Second Identical Foils. O051200400012 (2.).The Third Identical Foils. O051200400013 ENDBIB 11 0 O051200400014 NOCOMMON 0 0 O051200400015 DATA 7 2 O051200400016 EN DATA 1ERR-T 1DATA 2ERR-T 2MONIT O051200400017 FLAG O051200400018 MEV MB MB MB MB MB O051200400019 NO-DIM O051200400020 590. 57. 8. 0.78 0.39 10.7O051200400021 1. O051200400022 590. 48. 7. 0.8 0.25 10.7O051200400023 2. O051200400024 ENDDATA 8 0 O051200400025 ENDSUBENT 24 0 O051200499999 SUBENT O0512005 19991117 0000O051200500001 BIB 5 11 O051200500002 REACTION 1(74-W-0(P,X)69-TM-167,CUM,SIG) O051200500003 2(74-W-0(P,X)69-TM-168,IND,SIG) O051200500004 RAD-DET (69-TM-167,DG) O051200500005 (69-TM-168,DG) O051200500006 DECAY-DATA (69-TM-167,9.6D,DG,208.,0.43,DG,532.,0.02) O051200500007 (69-TM-168,87.D,DG,184.,0.18,DG,198.,0.53,DG,447.,0.24,O051200500008 DG,720.,0.12,DG,741.,0.12,DG,816.,0.5,DG,821.,0.12) O051200500009 SAMPLE The High-Purity Metal Foils of Tungsten,Thickness O051200500010 495 mg/cm**2,2.4 cm in Diameter,were Used. O051200500011 FLAG (1.).The Second Identical Foils. O051200500012 (2.).The Third Identical Foils. O051200500013 ENDBIB 11 0 O051200500014 NOCOMMON 0 0 O051200500015 DATA 7 2 O051200500016 EN DATA 1ERR-T 1DATA 2ERR-T 2MONIT O051200500017 FLAG O051200500018 MEV MB MB MB MB MB O051200500019 NO-DIM O051200500020 590. 50. 7. 0.54 0.27 10.7O051200500021 1. O051200500022 590. 47. 7. 0.23 0.14 10.7O051200500023 2. O051200500024 ENDDATA 8 0 O051200500025 ENDSUBENT 24 0 O051200599999 ENDENTRY 5 0 O051299999999