ENTRY O0460 20050204 0000O046000000001 SUBENT O0460001 20050204 0000O046000100001 BIB 9 15 O046000100002 INSTITUTE (2UK BIR) O046000100003 REFERENCE (J,NP/A,147,273,1970) O046000100004 AUTHOR (M.Ahmed, J.Lowe, P.M.Rolph, O.Karban) O046000100005 TITLE Differential cross sections, polarisations and proton- O046000100006 gamma angular correlations for Fe-54, Ni-60(P,P') O046000100007 and (p,p'g) at 10 MeV. O046000100008 METHOD (SITA) O046000100009 (BCINT) O046000100010 ERR-ANALYS (ANG-ERR-D).Data-point reader uncertainty. O046000100011 ADD-RES (COMP).Optical model analysis. O046000100012 STATUS (CURVE).By CAJAD. O046000100013 HISTORY (19980625C) O046000100014 (20041101A) Updated for new rules. O046000100015 (20040811A) Error heading update. O046000100016 (20050204U) Last checking has been done. O046000100017 ENDBIB 15 0 O046000100018 NOCOMMON 0 0 O046000100019 ENDSUBENT 18 0 O046000199999 SUBENT O0460002 20050204 0000O046000200001 BIB 7 16 O046000200002 REACTION (26-FE-54(P,EL)26-FE-54,,DA) O046000200003 FACILITY (LINAC,2UK NIN) O046000200004 INC-SOURCE (POLIS) Beam polarization is 0.5 O046000200005 SAMPLE A self-supporting, isotopically enriched target Fe-54, O046000200006 thickness 5.6 mg/cm**2,was used. O046000200007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000200008 measurments to be made at four scattering angles O046000200009 simultaneously. O046000200010 (SCIN) Two scintillation detectors mounted at + and - O046000200011 17 degrees. The counting rates in these detectors O046000200012 served as relative monitor of the incident beam O046000200013 intensity, and in addition, the ratio of their countingO046000200014 rates provided a check on the centering of the beam O046000200015 spot on the target. O046000200016 PART-DET (P) O046000200017 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000200018 ENDBIB 16 0 O046000200019 COMMON 2 3 O046000200020 EN ANG-ERR-D O046000200021 MEV ADEG O046000200022 10. 0.8 O046000200023 ENDCOMMON 3 0 O046000200024 DATA 3 27 O046000200025 ANG-CM DATA-CM ERR-T O046000200026 ADEG MB/SR PER-CENT O046000200027 36.8 970. 5. O046000200028 42.1 650. 5. O046000200029 47.4 432. 5. O046000200030 52.1 280. 5. O046000200031 56.3 177. 6. O046000200032 61.6 106. 6. O046000200033 67.6 57. 5. O046000200034 71.8 31.3 6. O046000200035 76.5 18.2 5. O046000200036 81.2 12.8 5. O046000200037 85.9 14. 6. O046000200038 91.8 16.6 5. O046000200039 96.4 21.3 4. O046000200040 101.7 22.6 6. O046000200041 106.9 24.7 5. O046000200042 111. 25.5 5. O046000200043 116.3 23.6 6. O046000200044 121.6 20.7 6. O046000200045 126.3 18.7 5. O046000200046 132.2 16.8 5. O046000200047 136.3 14.4 6. O046000200048 141. 12.9 5. O046000200049 145.7 11.6 6. O046000200050 151.6 11.4 4. O046000200051 155.7 11.5 7. O046000200052 160.9 11.2 6. O046000200053 166.8 11.3 7. O046000200054 ENDDATA 29 0 O046000200055 ENDSUBENT 54 0 O046000299999 SUBENT O0460003 20050204 0000O046000300001 BIB 7 17 O046000300002 REACTION (26-FE-54(P,EL)26-FE-54,,POL/DA) O046000300003 FACILITY (LINAC,2UK NIN) O046000300004 INC-SOURCE (POLIS) Beam polarization is 0.5 O046000300005 SAMPLE A self-supporting, isotopically enriched target Fe-54, O046000300006 thickness 5.6 mg/cm**2, was used. O046000300007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000300008 measurments to be made at four scattering angles O046000300009 simultaneously. O046000300010 (SCIN) Two scintillation detectors mounted at + and - O046000300011 17 degrees. The counting rates in these detectors O046000300012 served as relative monitor of the incident beam O046000300013 intensity, and in addition, the ratio of their countingO046000300014 rates provided a check on the centering of the beam O046000300015 spot on the target. O046000300016 PART-DET (P) O046000300017 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000300018 (ERR-DIG).Data-point reader uncertainty. O046000300019 ENDBIB 17 0 O046000300020 COMMON 3 3 O046000300021 EN ANG-ERR-D ERR-DIG O046000300022 MEV ADEG NO-DIM O046000300023 10. 0.8 0.017 O046000300024 ENDCOMMON 3 0 O046000300025 DATA 3 26 O046000300026 ANG-CM DATA-CM ERR-T O046000300027 ADEG NO-DIM NO-DIM O046000300028 34.7 1.3E-02 O046000300029 39.3 1.2E-02 O046000300030 46.3 -2.2E-03 O046000300031 50.4 -6.7E-02 O046000300032 55.7 -0.113 O046000300033 61.5 -0.182 1.8E-02 O046000300034 65.6 -0.251 1.8E-02 O046000300035 70.3 -0.309 2.5E-02 O046000300036 75.5 -0.155 1.8E-02 O046000300037 80. 0.2 1.8E-02 O046000300038 86.3 0.461 2.5E-02 O046000300039 90.4 0.521 2.5E-02 O046000300040 96.2 0.428 1.7E-02 O046000300041 100.3 0.359 2.4E-02 O046000300042 105.6 0.254 2.1E-02 O046000300043 110.3 0.138 2.9E-02 O046000300044 120.9 -0.106 2.9E-02 O046000300045 125.6 -0.246 2.1E-02 O046000300046 130.3 -0.374 2.5E-02 O046000300047 134.4 -0.44 3.E-02 O046000300048 140.2 -0.36 3.E-02 O046000300049 146. -0.24 4.E-02 O046000300050 151.2 -5.1E-02 2.9E-02 O046000300051 155.7 0.198 2.9E-02 O046000300052 160.4 0.27 2.1E-02 O046000300053 165.6 0.35 3.E-02 O046000300054 ENDDATA 28 0 O046000300055 ENDSUBENT 54 0 O046000399999 SUBENT O0460004 20050204 0000O046000400001 BIB 8 17 O046000400002 REACTION (26-FE-54(P,INL)26-FE-54,PAR,DA) O046000400003 FACILITY (LINAC,2UK NIN) O046000400004 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000400005 SAMPLE A self-supporting,isotopically enriched target Fe-54, O046000400006 thickness 5.6 mg/cm**2,was used. O046000400007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000400008 measurments to be made at four scattering angles O046000400009 simultaneously. O046000400010 (SCIN) Two scintillation detectors mounted at + and - O046000400011 17 degrees. The counting rates in these detectors O046000400012 served as relative monitor of the incident beam O046000400013 intensity, and in addition, the ratio of their countingO046000400014 rates provided a check on the centering of the beam O046000400015 spot on the target. O046000400016 PART-DET (P) O046000400017 EN-SEC (E-LVL,26-FE-54) O046000400018 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000400019 ENDBIB 17 0 O046000400020 COMMON 3 3 O046000400021 EN ANG-ERR-D E-LVL O046000400022 MEV ADEG MEV O046000400023 10. 0.8 1.41 O046000400024 ENDCOMMON 3 0 O046000400025 DATA 3 27 O046000400026 ANG-CM DATA-CM ERR-T O046000400027 ADEG MB/SR PER-CENT O046000400028 36.1 9.2 5. O046000400029 41.5 8. 5. O046000400030 46.5 7.8 5. O046000400031 50.9 7.1 4. O046000400032 55.4 6.27 5. O046000400033 60.3 5.78 5. O046000400034 66.7 5.5 5. O046000400035 70.7 5.03 5. O046000400036 76.1 4.83 5. O046000400037 82.1 4.7 4. O046000400038 86.6 4.58 5. O046000400039 91.6 4.71 5. O046000400040 96.1 4.78 5. O046000400041 101.5 4.78 4. O046000400042 106.5 4.85 4. O046000400043 111.5 5.13 4. O046000400044 116. 5.5 5. O046000400045 122. 5.36 5. O046000400046 126. 5.5 5. O046000400047 130.5 6. 7. O046000400048 136. 6.43 5. O046000400049 141.5 6.8 6. O046000400050 146.5 6.9 4. O046000400051 151. 7.1 4. O046000400052 155.5 7.5 4. O046000400053 161. 7.4 5. O046000400054 165.5 7.62 4. O046000400055 ENDDATA 29 0 O046000400056 ENDSUBENT 55 0 O046000499999 SUBENT O0460005 20050204 0000O046000500001 BIB 9 20 O046000500002 REACTION (26-FE-54(P,INL)26-FE-54,PAR,POL/DA,,ASY) Figure 3 O046000500003 COMMENT -By compiler. Attention! According to original text O046000500004 (see P.275) the figure contains data for polarization,O046000500005 but Y-axis on the figure is named "asymmetry". O046000500006 FACILITY (LINAC,2UK NIN) O046000500007 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000500008 SAMPLE A self-supporting,isotopically enriched target Fe-54, O046000500009 thickness 5.6 mg/cm**2,was used. O046000500010 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000500011 measurments to be made at four scattering angles O046000500012 simultaneously. O046000500013 (SCIN) Two scintillation detectors mounted at + and - O046000500014 17 degrees. The counting rates in these detectors O046000500015 served as relative monitor of the incident beam O046000500016 intensity, and in addition, the ratio of their countingO046000500017 rates provided a check on the centering of the beam O046000500018 spot on the target. O046000500019 PART-DET (P) O046000500020 EN-SEC (E-LVL,26-FE-54) O046000500021 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000500022 ENDBIB 20 0 O046000500023 COMMON 3 3 O046000500024 EN E-LVL ANG-ERR-D O046000500025 MEV MEV ADEG O046000500026 10. 1.41 0.7 O046000500027 ENDCOMMON 3 0 O046000500028 DATA 3 27 O046000500029 ANG-CM DATA-CM ERR-T O046000500030 ADEG NO-DIM NO-DIM O046000500031 35.6 0.1 4.E-02 O046000500032 40.5 5.E-02 4.E-02 O046000500033 45.5 6.4E-02 2.8E-02 O046000500034 50.5 9.E-02 3.E-02 O046000500035 55.4 4.9E-02 2.8E-02 O046000500036 59.9 3.4E-02 2.4E-02 O046000500037 65.3 4.E-03 2.4E-02 O046000500038 70.8 2.4E-02 2.1E-02 O046000500039 75.8 3.4E-02 2.1E-02 O046000500040 80.8 5.4E-02 2.8E-02 O046000500041 85.2 6.4E-02 1.9E-02 O046000500042 90.7 5.4E-02 2.4E-02 O046000500043 95.7 6.9E-02 1.4E-02 O046000500044 99.6 6.4E-02 1.4E-02 O046000500045 106.2 0.119 2.1E-02 O046000500046 111.1 0.114 1.7E-02 O046000500047 115.6 0.109 1.9E-02 O046000500048 120.6 0.114 1.9E-02 O046000500049 124.6 0.119 2.1E-02 O046000500050 130. 0.119 1.9E-02 O046000500051 135. 9.4E-02 2.4E-02 O046000500052 140.9 4.4E-02 2.4E-02 O046000500053 145.4 7.9E-02 1.9E-02 O046000500054 150.3 7.4E-02 1.2E-02 O046000500055 154.8 6.4E-02 1.9E-02 O046000500056 159.7 2.9E-02 1.7E-02 O046000500057 163.7 5.4E-02 1.7E-02 O046000500058 ENDDATA 29 0 O046000500059 ENDSUBENT 58 0 O046000599999 SUBENT O0460006 20050204 0000O046000600001 BIB 7 16 O046000600002 REACTION (28-NI-60(P,EL)28-NI-60,,DA) O046000600003 FACILITY (LINAC,2UK NIN) O046000600004 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000600005 SAMPLE A self-supporting,isotopically enriched target Ni-60, O046000600006 thickness 5.3 mg/cm**2,was used. O046000600007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000600008 measurments to be made at four scattering angles O046000600009 simultaneously. O046000600010 (SCIN) Two scintillation detectors mounted at + and - O046000600011 17 degrees. The counting rates in these detectors O046000600012 served as relative monitor of the incident beam O046000600013 intensity, and in addition, the ratio of their countingO046000600014 rates provided a check on the centering of the beam O046000600015 spot on the target. O046000600016 PART-DET (P) O046000600017 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000600018 ENDBIB 16 0 O046000600019 COMMON 2 3 O046000600020 EN ANG-ERR-D O046000600021 MEV ADEG O046000600022 10. 0.8 O046000600023 ENDCOMMON 3 0 O046000600024 DATA 3 29 O046000600025 ANG-CM DATA-CM ERR-T O046000600026 ADEG MB/SR PER-CENT O046000600027 27.4 3760. 3. O046000600028 31.6 2120. 3. O046000600029 36.8 1250. 3. O046000600030 42. 726. 3. O046000600031 46.6 462. 4. O046000600032 51.3 273. 4. O046000600033 56. 162. 4. O046000600034 61.7 79.1 4. O046000600035 66.9 48. 4. O046000600036 70.5 27.7 4. O046000600037 76.2 23. 3. O046000600038 80.3 26. 4. O046000600039 85.4 27.4 4. O046000600040 91. 30.2 4. O046000600041 96.1 31.9 4. O046000600042 101.2 30.5 4. O046000600043 105.8 26.5 4. O046000600044 110.9 23.6 3. O046000600045 115.5 20. 4. O046000600046 120.7 16.2 4. O046000600047 126.4 10.8 4. O046000600048 131.5 7.57 4. O046000600049 136.2 5.56 4. O046000600050 139.2 4.94 3. O046000600051 145.3 5.6 4. O046000600052 149.9 6.64 4. O046000600053 154. 8.7 3. O046000600054 159.6 10.8 4. O046000600055 165.1 12.8 4. O046000600056 ENDDATA 31 0 O046000600057 ENDSUBENT 56 0 O046000699999 SUBENT O0460007 20050204 0000O046000700001 BIB 7 17 O046000700002 REACTION (28-NI-60(P,EL)28-NI-60,,POL/DA) O046000700003 FACILITY (LINAC,2UK NIN) O046000700004 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000700005 SAMPLE A self-supporting,isotopically enriched target Ni-60, O046000700006 thickness 5.3 mg/cm**2,was used. O046000700007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000700008 measurments to be made at four scattering angles O046000700009 simultaneously. O046000700010 (SCIN) Two scintillation detectors mounted at + and - O046000700011 17 degrees. The counting rates in these detectors O046000700012 served as relative monitor of the incident beam O046000700013 intensity, and in addition, the ratio of their countingO046000700014 rates provided a check on the centering of the beam O046000700015 spot on the target. O046000700016 PART-DET (P) O046000700017 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000700018 (ERR-DIG).Data-point reader uncertainty. O046000700019 ENDBIB 17 0 O046000700020 COMMON 3 3 O046000700021 EN ANG-ERR-D ERR-DIG O046000700022 MEV ADEG NO-DIM O046000700023 10. 0.7 1.6E-02 O046000700024 ENDCOMMON 3 0 O046000700025 DATA 3 28 O046000700026 ANG-CM DATA-CM ERR-T O046000700027 ADEG NO-DIM NO-DIM O046000700028 26.4 2.2E-02 O046000700029 30. 1.9E-02 O046000700030 35.6 1.1E-02 O046000700031 40.3 -1.8E-02 O046000700032 44.9 -4.8E-02 O046000700033 49.5 -8.8E-02 O046000700034 55.2 -0.14 4.E-02 O046000700035 65. -0.197 1.8E-02 O046000700036 70. -3.7E-02 1.8E-02 O046000700037 75.6 0.239 1.8E-02 O046000700038 80.6 0.398 1.8E-02 O046000700039 84.7 0.42 2.E-02 O046000700040 91.4 0.361 2.2E-02 O046000700041 96.1 0.279 1.8E-02 O046000700042 100.7 0.197 1.8E-02 O046000700043 105.4 0.115 1.8E-02 O046000700044 110.6 1.2E-02 1.8E-02 O046000700045 116.3 -0.101 1.8E-02 O046000700046 120.4 -0.204 1.8E-02 O046000700047 126.1 -0.275 1.8E-02 O046000700048 129.7 -0.337 1.8E-02 O046000700049 135.3 -0.198 1.8E-02 O046000700050 139.7 0.172 2.6E-02 O046000700051 144.7 0.531 2.2E-02 O046000700052 150.3 0.72 3.E-02 O046000700053 155.4 0.72 3.E-02 O046000700054 160.6 0.643 2.2E-02 O046000700055 165.8 0.519 2.2E-02 O046000700056 ENDDATA 30 0 O046000700057 ENDSUBENT 56 0 O046000799999 SUBENT O0460008 20050204 0000O046000800001 BIB 8 17 O046000800002 REACTION (28-NI-60(P,INL)28-NI-60,PAR,DA) O046000800003 FACILITY (LINAC,2UK NIN) O046000800004 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000800005 SAMPLE A self-supporting,isotopically enriched target Ni-60, O046000800006 thickness 5.3 mg/cm**2,was used. O046000800007 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000800008 measurments to be made at four scattering angles O046000800009 simultaneously. O046000800010 (SCIN) Two scintillation detectors mounted at + and - O046000800011 17 degrees. The counting rates in these detectors O046000800012 served as relative monitor of the incident beam O046000800013 intensity, and in addition, the ratio of their countingO046000800014 rates provided a check on the centering of the beam O046000800015 spot on the target. O046000800016 PART-DET (P) O046000800017 EN-SEC (E-LVL,28-NI-60) O046000800018 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000800019 ENDBIB 17 0 O046000800020 COMMON 3 3 O046000800021 EN E-LVL ANG-ERR-D O046000800022 MEV MEV ADEG O046000800023 10. 1.33 0.7 O046000800024 ENDCOMMON 3 0 O046000800025 DATA 3 29 O046000800026 ANG-CM DATA-CM ERR-T O046000800027 ADEG MB/SR PER-CENT O046000800028 25.4 10.2 4. O046000800029 31.8 10.9 5. O046000800030 36.6 10.6 6. O046000800031 41. 10.3 5. O046000800032 46.8 9.5 5. O046000800033 51. 8.1 4. O046000800034 57.3 7.3 5. O046000800035 61.9 5.61 5. O046000800036 66.7 5.04 5. O046000800037 71.4 3.96 3. O046000800038 76.6 3.32 6. O046000800039 82.3 3.02 5. O046000800040 86.7 2.94 5. O046000800041 92.1 3.05 6. O046000800042 97.4 3.17 5. O046000800043 102.8 3.26 5. O046000800044 107.1 3.08 5. O046000800045 112.5 3. 4. O046000800046 117.3 2.92 4. O046000800047 122.1 2.69 4. O046000800048 126.9 2.51 4. O046000800049 131.2 2.25 5. O046000800050 136.6 2.25 5. O046000800051 141.9 2.31 6. O046000800052 146.8 2.25 5. O046000800053 151.6 2.3 5. O046000800054 157. 2.33 5. O046000800055 161.9 2.3 4. O046000800056 167.2 2.32 6. O046000800057 ENDDATA 31 0 O046000800058 ENDSUBENT 57 0 O046000899999 SUBENT O0460009 20050204 0000O046000900001 BIB 9 20 O046000900002 REACTION (28-NI-60(P,INL)28-NI-60,PAR,POL/DA,,ASY) O046000900003 COMMENT -By compiler. Attention! According to original text O046000900004 (see P.275) the figure contains data for polarization,O046000900005 but Y-axis on the figure is named "asymmetry". O046000900006 FACILITY (LINAC,2UK NIN) O046000900007 INC-SOURCE (POLIS) Beam pollarization is 0.5 O046000900008 SAMPLE A self-supporting,isotopically enriched target Ni-60, O046000900009 thickness 5.3 mg/cm**2,was used. O046000900010 DETECTOR (SILI).A four 5 mm deep Si(Li) detectors, enabling O046000900011 measurments to be made at four scattering angles O046000900012 simultaneously. O046000900013 (SCIN) Two scintillation detectors mounted at + and - O046000900014 17 degrees. The counting rates in these detectors O046000900015 served as relative monitor of the incident beam O046000900016 intensity, and in addition, the ratio of their countingO046000900017 rates provided a check on the centering of the beam O046000900018 spot on the target. O046000900019 PART-DET (P) O046000900020 EN-SEC (E-LVL,28-NI-60) O046000900021 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046000900022 ENDBIB 20 0 O046000900023 COMMON 3 3 O046000900024 EN E-LVL ANG-ERR-D O046000900025 MEV MEV ADEG O046000900026 10. 1.33 0.7 O046000900027 ENDCOMMON 3 0 O046000900028 DATA 3 29 O046000900029 ANG-CM DATA-CM ERR-T O046000900030 ADEG NO-DIM NO-DIM O046000900031 24.2 6.E-02 4.E-02 O046000900032 30.6 0.11 4.E-02 O046000900033 35.5 8.6E-02 2.8E-02 O046000900034 40.9 0.1 2.8E-02 O046000900035 45.2 9.5E-02 2.3E-02 O046000900036 50.6 4.E-02 3.E-02 O046000900037 55.9 4.E-02 1.6E-02 O046000900038 61.3 1.1E-02 1.4E-02 O046000900039 67.1 -1.5E-02 1.4E-02 O046000900040 71.5 -3.5E-02 1.2E-02 O046000900041 76.3 -6.9E-02 1.9E-02 O046000900042 81.6 -9.9E-02 1.6E-02 O046000900043 86. -0.11 2.1E-02 O046000900044 91.4 -9.5E-02 1.6E-02 O046000900045 96.8 -8.1E-02 1.6E-02 O046000900046 101.7 -4.7E-02 1.9E-02 O046000900047 106.2 -3.E-03 2.1E-02 O046000900048 112. 7.E-03 1.6E-02 O046000900049 117.4 -4.E-03 1.4E-02 O046000900050 121.8 -4.E-03 1.4E-02 O046000900051 127.7 -6.E-03 2.1E-02 O046000900052 131.6 -9.E-03 2.1E-02 O046000900053 135.9 -2.E-02 2.3E-02 O046000900054 141.8 -2.E-02 1.2E-02 O046000900055 146.7 -4.E-02 1.4E-02 O046000900056 151.1 -2.1E-02 1.9E-02 O046000900057 156.5 -8.E-03 2.1E-02 O046000900058 161.4 3.E-03 2.1E-02 O046000900059 166.2 3.E-03 1.6E-02 O046000900060 ENDDATA 31 0 O046000900061 ENDSUBENT 60 0 O046000999999 SUBENT O0460010 20050204 0000O046001000001 BIB 8 14 O046001000002 REACTION (26-FE-54(P,G+P)26-FE-54,PAR,DA/DA,G/P,NCP/REL) O046001000003 FACILITY (CYCLO,2UK BIR) The Nuffield cyclotron. O046001000004 SAMPLE The isotopically enriched target Fe-54, 1 mg/cm**2 O046001000005 thickness, was used. O046001000006 DETECTOR (NAICR).7.62*7.62 cm cylindrical Na-I(Tl) scintillator O046001000007 for the gamma. O046001000008 (SIBAR).Two Si surface barrier detectors for protons. O046001000009 PART-DET (P) O046001000010 (G) O046001000011 EN-SEC (E-LVL,26-FE-54) O046001000012 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046001000013 COMMENT - By authors - outgoing proton angle was varied and O046001000014 the gamma detector was held fixed along the direction O046001000015 K/in*K/out. O046001000016 ENDBIB 14 0 O046001000017 COMMON 5 3 O046001000018 EN E-LVL ANG-ERR-D ANG1 ANG-AZ-RL O046001000019 MEV MEV ADEG ADEG ADEG O046001000020 10.1 1.41 0.7 90. 90. O046001000021 ENDCOMMON 3 0 O046001000022 DATA 3 18 O046001000023 ANG2-CM DATA ERR-T O046001000024 ADEG ARB-UNITS ARB-UNITS O046001000025 30.8 0.56 5.E-02 O046001000026 38.8 0.6 4.E-02 O046001000027 47.2 0.52 4.E-02 O046001000028 54.9 0.9 4.E-02 O046001000029 64.1 1.32 6.E-02 O046001000030 72. 1.34 9.E-02 O046001000031 80.5 1.36 4.E-02 O046001000032 87.9 1.26 5.E-02 O046001000033 96.4 1.28 5.E-02 O046001000034 103.9 1.35 7.E-02 O046001000035 112.9 1.45 8.E-02 O046001000036 121.4 1.52 6.E-02 O046001000037 128.3 1.32 5.E-02 O046001000038 136.8 1.36 7.E-02 O046001000039 141.2 1.29 4.E-02 O046001000040 146. 0.95 4.E-02 O046001000041 149.5 0.95 4.E-02 O046001000042 154. 0.91 4.E-02 O046001000043 ENDDATA 20 0 O046001000044 ENDSUBENT 43 0 O046001099999 SUBENT O0460011 20050204 0000O046001100001 BIB 8 14 O046001100002 REACTION (28-NI-60(P,G+P)28-NI-60,PAR,DA/DA,G/P,NCP/REL) O046001100003 FACILITY (CYCLO,2UK BIR).The Nuffield cyclotron. O046001100004 SAMPLE The isotopically enriched target Ni-60,2 mg/cm**2 O046001100005 thickness,was used. O046001100006 DETECTOR (NAICR).7.62*7.62 cm cylindrical NaI(Tl) scintillator O046001100007 for the gamma. O046001100008 (SIBAR).Two Si surface barrier detectors for protons. O046001100009 PART-DET (P) O046001100010 (G) O046001100011 EN-SEC (E-LVL,28-NI-60) O046001100012 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O046001100013 COMMENT - By authors - outgoing proton angle was varied and O046001100014 the gamma detector was held fixed along the direction O046001100015 K/in*K/out. O046001100016 ENDBIB 14 0 O046001100017 COMMON 5 3 O046001100018 EN E-LVL ANG-ERR-D ANG1 ANG-AZ-RL O046001100019 MEV MEV ADEG ADEG ADEG O046001100020 10.1 1.33 0.7 90. 90. O046001100021 ENDCOMMON 3 0 O046001100022 DATA 3 16 O046001100023 ANG2-CM DATA ERR-T O046001100024 ADEG ARB-UNITS ARB-UNITS O046001100025 30.6 0.21 5.E-02 O046001100026 38.6 0.19 4.E-02 O046001100027 46.6 0.3 3.E-02 O046001100028 54.1 0.403 3.E-02 O046001100029 64.1 0.45 3.E-02 O046001100030 73.1 0.51 4.E-02 O046001100031 79.7 0.69 5.E-02 O046001100032 87.6 0.58 4.E-02 O046001100033 95.6 0.61 3.E-02 O046001100034 103.6 0.61 4.E-02 O046001100035 112.1 0.74 3.E-02 O046001100036 120.8 1.08 4.E-02 O046001100037 127.7 1.1 5.E-02 O046001100038 136.3 1.22 8.E-02 O046001100039 146.7 1.08 6.E-02 O046001100040 153.4 0.73 4.E-02 O046001100041 ENDDATA 18 0 O046001100042 ENDSUBENT 41 0 O046001199999 ENDENTRY 11 0 O046099999999