ENTRY O0406 20120527 O048O040600000001 SUBENT O0406001 20120527 O048O040600100001 BIB 10 45 O040600100002 TITLE Investigation of isotopic effects in nuclear reactions O040600100003 induced by 660-MeV protons. O040600100004 AUTHOR (V.I.Bogatin,V.K.Bondarev,V.F.Litvin,O.V.Lozhkin, O040600100005 N.A.Perfilov,Yu.P.Yakovlev,V.P.Bochin) O040600100006 INSTITUTE (4RUSRI ) O040600100007 REFERENCE (J,YF,19,32,1974) O040600100008 (J,SNP,19,16,1974) English transl. O040600100009 DETECTOR (TELES,SIBAR,SOLST).Telescope consisted from 3 O040600100010 surface-barrier silicon detectors-dE/dx detector, O040600100011 thickness 23 and 40 mum, detector E ,thickness 800 mumO040600100012 and anticoincidence detector, thickness 500 mum. O040600100013 FACILITY (SYNCY,4ZZZDUB) O040600100014 METHOD (SITA) O040600100015 (EDE) O040600100016 (BCINT) Ionization chamber was calibrated by O040600100017 monitor reactions. O040600100018 Three independent series of measurements were obtained O040600100019 with 58Ni and 64Ni , and three series with 1l2Sn and O040600100020 124Sn. In order to detect possible systematic errors, O040600100021 the measurements were repeated after long time O040600100022 intervals and under different experimental conditions O040600100023 (different targets positioned differently in the O040600100024 chamber, different proton beam intensity, and O040600100025 recalibration of the monitor). O040600100026 MONITOR (13-AL-27(P,X)11-NA-24,CUM,SIG) O040600100027 (6-C-12(P,N+P)6-C-11,,SIG) O040600100028 The proton beam was monitored with an ionization O040600100029 chamber that had been calibrated by means of the O040600100030 reactions 27Al(p,3pn)24Na and 12C(p,pn)llC. O040600100031 COMMENT /by Authors/.Two isotopic effects are detected- O040600100032 a correlation between the absolute production cross O040600100033 sections for the product isotope particles and the O040600100034 mass number of the target nuclear isotopes and a O040600100035 variation of shape of the particle energy spectra when O040600100036 substituting one target isotope for another. O040600100037 Dependence of the ratio of the production cross O040600100038 sections on the product particle isospin and on the O040600100039 difference between their separation energies for two O040600100040 target isotopes is found. O040600100041 HISTORY (19980205C) O040600100042 (19980302U) Last checking has been done. O040600100043 (20000426A) DATE is corrected O040600100044 (20120527A)SD: Updated to new date formats; BIB update;O040600100045 corrected according to last EXFOR rules and Dict. O040600100046 Ref. on English transl. (SNP,19,16,1974) added. O040600100047 ENDBIB 45 0 O040600100048 COMMON 1 3 O040600100049 EN O040600100050 MEV O040600100051 600. O040600100052 ENDCOMMON 3 0 O040600100053 ENDSUBENT 52 0 O040600199999 SUBENT O0406002 20120527 O048O040600200001 BIB 5 8 O040600200002 REACTION (28-NI-58(P,X)2-HE-4,,DA/DE,,REL) Fig.2a/1 O040600200003 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040600200004 chemically pure separated nickel; 8.133 mg/cm2 thick O040600200005 EN-SEC (E,A) O040600200006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600200007 (ERR-DIG).Data-point reader uncertainty. O040600200008 (E-ERR-DIG).Data-point reader uncertainty. O040600200009 STATUS (CURVE).By CAJAD from Fig.2a/1 of YF,19,32,1974 O040600200010 ENDBIB 8 0 O040600200011 COMMON 3 3 O040600200012 ANG E-ERR-DIG ERR-DIG O040600200013 ADEG MEV PER-CENT O040600200014 90. 0.16 1.4 O040600200015 ENDCOMMON 3 0 O040600200016 DATA 3 61 O040600200017 E DATA DATA-ERR O040600200018 MEV ARB-UNITS PER-CENT O040600200019 3.96 96.3 O040600200020 4.9 558. 4. O040600200021 5.32 1114. O040600200022 5.92 1292. O040600200023 6.5 1417. O040600200024 6.85 1484. O040600200025 7.3 1511. O040600200026 7.98 1523. O040600200027 8.55 1620. 2.5 O040600200028 8.88 1594. O040600200029 9.31 1506. O040600200030 9.86 1462. O040600200031 10.4 1331. O040600200032 10.94 1245. O040600200033 11.37 1176. O040600200034 11.9 1080. O040600200035 12.33 1011. O040600200036 12.86 920. O040600200037 13.28 837. O040600200038 13.82 762. O040600200039 14.25 726. O040600200040 14.77 643. O040600200041 15.09 596. O040600200042 15.75 573. O040600200043 16.16 503. O040600200044 16.8 457. O040600200045 17.22 408. O040600200046 17.53 379. O040600200047 17.98 386. O040600200048 18.53 368. 4. O040600200049 18.94 328. O040600200050 19.48 302. O040600200051 20.12 274. O040600200052 20.54 247. O040600200053 21.12 271. O040600200054 21.66 254. O040600200055 21.95 212.5 O040600200056 22.5 208. O040600200057 22.78 169.5 O040600200058 23.28 137.9 O040600200059 23.45 167.7 O040600200060 23.64 149.9 O040600200061 24.2 151.1 O040600200062 24.82 127.6 O040600200063 25.4 138.6 O040600200064 25.7 122.7 O040600200065 26.41 138.4 O040600200066 26.49 122.5 O040600200067 26.69 114.7 O040600200068 27.35 110.4 O040600200069 27.77 98.6 O040600200070 28.09 96. 9. O040600200071 28.97 91.3 O040600200072 29.11 99.3 O040600200073 29.66 95.5 O040600200074 30.23 101.9 O040600200075 30.79 100.9 O040600200076 31.32 91.8 O040600200077 31.76 90.8 O040600200078 32.44 92.4 O040600200079 32.87 87.3 O040600200080 ENDDATA 63 0 O040600200081 ENDSUBENT 80 0 O040600299999 SUBENT O0406003 20120527 O048O040600300001 BIB 5 8 O040600300002 REACTION (28-NI-64(P,X)2-HE-4,,DA/DE,,REL) Fig.2a/2 O040600300003 SAMPLE (28-NI-64,ENR=0.898) target was metal foil of O040600300004 chemically pure separated nickel; 9.678 mg/cm2 thick O040600300005 EN-SEC (E,A) O040600300006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600300007 (ERR-DIG).Data-point reader uncertainty. O040600300008 (E-ERR-DIG).Data-point reader uncertainty. O040600300009 STATUS (CURVE).By CAJAD from Fig.2a/2 of YF,19,32,1974 O040600300010 ENDBIB 8 0 O040600300011 COMMON 3 3 O040600300012 ANG E-ERR-DIG ERR-DIG O040600300013 ADEG MEV PER-CENT O040600300014 90. 0.16 1.4 O040600300015 ENDCOMMON 3 0 O040600300016 DATA 3 58 O040600300017 E DATA DATA-ERR O040600300018 MEV ARB-UNITS PER-CENT O040600300019 3.77 72.1 O040600300020 4.7 402. 4. O040600300021 5.23 803. O040600300022 5.85 1004. O040600300023 6.45 1154. O040600300024 7.11 1142. O040600300025 7.25 1242. O040600300026 7.92 1240. O040600300027 8.03 1240. O040600300028 8.36 1228. O040600300029 8.81 1250. O040600300030 9.38 1296. O040600300031 10.13 1146. O040600300032 10.45 1083. O040600300033 10.99 1023. O040600300034 11.18 914. O040600300035 11.63 913. O040600300036 12.49 808. O040600300037 12.78 689. O040600300038 13.35 714. O040600300039 13.67 675. O040600300040 14.09 620. O040600300041 14.63 580. O040600300042 14.94 518. O040600300043 15.48 494. O040600300044 16.23 437. O040600300045 16.44 421. O040600300046 16.98 394. O040600300047 17.4 362. O040600300048 17.96 361. O040600300049 18.69 296. 5. O040600300050 18.89 278. O040600300051 19.44 262. O040600300052 20.11 264. O040600300053 20.3 232. O040600300054 20.84 219. O040600300055 21.41 229. O040600300056 21.93 200.9 O040600300057 22.44 166.5 O040600300058 22.87 158.7 O040600300059 23.84 139. O040600300060 24.21 156.9 O040600300061 24.75 145.4 O040600300062 25.38 126.3 O040600300063 25.83 127.3 O040600300064 26.7 120.2 O040600300065 27.27 126. 8. O040600300066 27.89 104.3 O040600300067 28.46 106.1 O040600300068 28.88 97.5 O040600300069 29.56 102. O040600300070 29.73 124.1 O040600300071 30.26 112.9 O040600300072 30.84 122.7 O040600300073 31.31 87.6 O040600300074 31.8 102.6 O040600300075 32.35 98.7 O040600300076 32.72 76.6 O040600300077 ENDDATA 60 0 O040600300078 ENDSUBENT 77 0 O040600399999 SUBENT O0406004 20120527 O048O040600400001 BIB 5 7 O040600400002 REACTION (28-NI-58(P,X)2-HE-3,,DA/DE,,REL) Fig. 2a/3 O040600400003 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040600400004 chemically pure separated nickel; 8.133 mg/cm2 thick O040600400005 EN-SEC (E,HE3) O040600400006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600400007 (E-ERR-DIG).Data-point reader uncertainty. O040600400008 STATUS (CURVE).By CAJAD from Fig.2a/3 of YF,19,32,1974 O040600400009 ENDBIB 7 0 O040600400010 COMMON 2 3 O040600400011 ANG E-ERR-DIG O040600400012 ADEG MEV O040600400013 90. 0.16 O040600400014 ENDCOMMON 3 0 O040600400015 DATA 3 34 O040600400016 E DATA DATA-ERR O040600400017 MEV ARB-UNITS PER-CENT O040600400018 7.59 174. 6. O040600400019 8.18 191. 6. O040600400020 8.61 186. 8. O040600400021 9.16 177. 5. O040600400022 9.48 166. 5. O040600400023 10.14 162. 6. O040600400024 10.58 156. 6. O040600400025 11.12 146. 5. O040600400026 11.55 138. 5. O040600400027 11.98 133. 6. O040600400028 12.42 128. 5. O040600400029 13.1 131. 7. O040600400030 13.43 130. 7. O040600400031 13.98 125. 7. O040600400032 14.28 110. 8. O040600400033 14.93 103. 8. O040600400034 15.48 100. 9. O040600400035 15.91 93. 8. O040600400036 16.44 86. 7. O040600400037 16.77 85. 7. O040600400038 17.33 83. 8. O040600400039 17.79 88. 8. O040600400040 18.45 86. 8. O040600400041 18.78 82. 9. O040600400042 19.3 73. 11. O040600400043 19.82 63. 10. O040600400044 20.48 62. 10. O040600400045 20.82 63. 10. O040600400046 21.29 67. 9. O040600400047 21.71 62. 13. O040600400048 22.36 57. 11. O040600400049 22.9 53. 9. O040600400050 23.31 47. 11. O040600400051 23.86 45. 11. O040600400052 ENDDATA 36 0 O040600400053 ENDSUBENT 52 0 O040600499999 SUBENT O0406005 20120527 O048O040600500001 BIB 5 7 O040600500002 REACTION (28-NI-64(P,X)2-HE-3,,DA/DE,,REL) Fig. 2a/4 O040600500003 SAMPLE (28-NI-64,ENR=0.898) target was metal foil of O040600500004 chemically pure separated nickel; 9.678 mg/cm2 thick O040600500005 EN-SEC (E,HE3) O040600500006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600500007 (E-ERR-DIG).Data-point reader uncertainty. O040600500008 STATUS (CURVE).By CAJAD from Fig.2a/4 of YF,19,32,1974 O040600500009 ENDBIB 7 0 O040600500010 COMMON 2 3 O040600500011 ANG E-ERR-DIG O040600500012 ADEG MEV O040600500013 90. 0.16 O040600500014 ENDCOMMON 3 0 O040600500015 DATA 3 33 O040600500016 E DATA DATA-ERR O040600500017 MEV ARB-UNITS PER-CENT O040600500018 7.57 107. 8. O040600500019 7.93 119. 8. O040600500020 8.47 109. 7. O040600500021 9.02 107. 10. O040600500022 9.31 93. 10. O040600500023 9.87 93. 10. O040600500024 10.31 89. 8. O040600500025 10.86 88. 8. O040600500026 11.39 78. 10. O040600500027 11.94 75. 9. O040600500028 12.26 72. 8. O040600500029 12.82 72. 11. O040600500030 13.4 77. 10. O040600500031 13.72 75. 9. O040600500032 14.4 78. 10. O040600500033 14.7 67. 9. O040600500034 15.47 65. 11. O040600500035 15.78 59. 10. O040600500036 16.44 57. 12. O040600500037 16.88 56. 11. O040600500038 17.24 60. 12. O040600500039 17.87 53. 11. O040600500040 18.18 47. 13. O040600500041 18.58 41. 12. O040600500042 19.28 45. 13. O040600500043 19.63 49. 12. O040600500044 20.52 48. 13. O040600500045 20.85 46. 11. O040600500046 21.29 45. 11. O040600500047 21.72 43. 14. O040600500048 22.23 36. 14. O040600500049 22.57 37. 14. O040600500050 23.25 37. 14. O040600500051 ENDDATA 35 0 O040600500052 ENDSUBENT 51 0 O040600599999 SUBENT O0406006 20120527 O048O040600600001 BIB 5 8 O040600600002 REACTION (50-SN-112(P,X)2-HE-4,,DA/DE,,REL) O040600600003 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040600600004 chemically pure separated nickel; 8.347 mg/cm2 thick O040600600005 EN-SEC (E,A) O040600600006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600600007 (ERR-DIG).Data-point reader uncertainty. O040600600008 (E-ERR-DIG).Data-point reader uncertainty. O040600600009 STATUS (CURVE).By CAJAD from Fig.2b/1 of YF,19,32,1974 O040600600010 ENDBIB 8 0 O040600600011 COMMON 3 3 O040600600012 ANG E-ERR-DIG ERR-DIG O040600600013 ADEG MEV PER-CENT O040600600014 90. 0.16 1.4 O040600600015 ENDCOMMON 3 0 O040600600016 DATA 3 51 O040600600017 E DATA DATA-ERR O040600600018 MEV ARB-UNITS PER-CENT O040600600019 7.85 1088. O040600600020 8.19 2470. O040600600021 8.62 2930. 3. O040600600022 9.52 3560. O040600600023 9.85 3890. O040600600024 10.53 4280. O040600600025 10.99 4450. O040600600026 11.46 4330. O040600600027 12.04 4420. O040600600028 12.52 4090. O040600600029 12.76 3860. O040600600030 13.35 3580. O040600600031 13.83 3250. O040600600032 14.31 2960. O040600600033 14.9 2710. O040600600034 15.5 2440. O040600600035 15.86 2240. O040600600036 16.35 1980. O040600600037 16.6 1731. O040600600038 17.07 1619. O040600600039 17.67 1430. O040600600040 18.38 1377. O040600600041 18.64 1158. O040600600042 19.12 1033. O040600600043 19.72 939. O040600600044 20.07 878. O040600600045 20.66 829. O040600600046 21.14 768. O040600600047 21.74 679. O040600600048 22.22 617. O040600600049 22.81 572. O040600600050 23.29 529. O040600600051 23.77 463. O040600600052 24.25 442. O040600600053 24.83 438. O040600600054 25.18 417. O040600600055 25.78 372. 5. O040600600056 26.38 325. O040600600057 26.86 304. O040600600058 27.43 317. O040600600059 27.79 305. O040600600060 28.38 283. O040600600061 28.85 280. O040600600062 29.2 270. O040600600063 29.78 267. O040600600064 30.37 255. O040600600065 30.84 248. O040600600066 31.42 253. O040600600067 31.88 250. O040600600068 32.36 234. O040600600069 32.73 204.9 O040600600070 ENDDATA 53 0 O040600600071 ENDSUBENT 70 0 O040600699999 SUBENT O0406007 20120527 O048O040600700001 BIB 5 8 O040600700002 REACTION (50-SN-124(P,X)2-HE-4,,DA/DE,,REL) O040600700003 SAMPLE (50-SN-124,ENR=0.953) target was metal foil of O040600700004 chemically pure separated nickel; 8.084 mg/cm2 thick O040600700005 EN-SEC (E,A) O040600700006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600700007 (ERR-DIG).Data-point reader uncertainty. O040600700008 (E-ERR-DIG).Data-point reader uncertainty. O040600700009 STATUS (CURVE).By CAJAD from Fig.2b/2 of YF,19,32,1974 O040600700010 ENDBIB 8 0 O040600700011 COMMON 3 3 O040600700012 ANG E-ERR-DIG ERR-DIG O040600700013 ADEG MEV PER-CENT O040600700014 90. 0.16 1.4 O040600700015 ENDCOMMON 3 0 O040600700016 DATA 3 51 O040600700017 E DATA DATA-ERR O040600700018 MEV ARB-UNITS PER-CENT O040600700019 7.79 776. O040600700020 8.28 1345. O040600700021 8.72 1600. 3. O040600700022 9.26 2018. O040600700023 9.83 2240. O040600700024 10.16 2450. O040600700025 10.85 2480. O040600700026 11.66 2580. O040600700027 11.78 2580. O040600700028 12.36 2480. O040600700029 12.83 2480. O040600700030 13.42 2340. O040600700031 13.78 2190. O040600700032 14.25 2012. O040600700033 14.85 1777. O040600700034 15.45 1631. O040600700035 15.7 1453. O040600700036 16.29 1386. O040600700037 16.76 1309. O040600700038 17.13 1167. O040600700039 17.73 1031. O040600700040 18.09 964. O040600700041 18.8 885. O040600700042 19.15 836. O040600700043 19.75 752. O040600700044 20.23 664. O040600700045 20.71 633. O040600700046 21.41 593. O040600700047 21.79 499. O040600700048 22.26 467. O040600700049 22.74 428. O040600700050 23.21 416. O040600700051 23.8 401. O040600700052 24.28 368. O040600700053 24.74 372. O040600700054 25.23 310. O040600700055 25.81 313. 5. O040600700056 26.28 298. O040600700057 26.65 266. O040600700058 27.34 271. O040600700059 27.74 195.8 O040600700060 28.17 244. O040600700061 28.63 257. O040600700062 29.21 254. O040600700063 29.9 257. O040600700064 30.15 243. O040600700065 30.76 198.5 O040600700066 31.34 198.7 O040600700067 31.92 202.7 O040600700068 32.49 214.9 O040600700069 32.86 187.9 O040600700070 ENDDATA 53 0 O040600700071 ENDSUBENT 70 0 O040600799999 SUBENT O0406008 20120527 O048O040600800001 BIB 5 7 O040600800002 REACTION (50-SN-112(P,X)2-HE-3,,DA/DE,,REL) O040600800003 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040600800004 chemically pure separated nickel; 8.347 mg/cm2 thick O040600800005 EN-SEC (E,HE3) O040600800006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600800007 (E-ERR-DIG).Data-point reader uncertainty. O040600800008 STATUS (CURVE).By CAJAD from Fig.2b/3 of YF,19,32,1974 O040600800009 ENDBIB 7 0 O040600800010 COMMON 2 3 O040600800011 ANG E-ERR-DIG O040600800012 ADEG MEV O040600800013 90. 0.16 O040600800014 ENDCOMMON 3 0 O040600800015 DATA 3 32 O040600800016 E DATA DATA-ERR O040600800017 MEV ARB-UNITS PER-CENT O040600800018 7.41 104. 7. O040600800019 7.82 145. 6. O040600800020 8.39 160. 6. O040600800021 8.84 177. 6. O040600800022 9.33 149. 5. O040600800023 9.91 144. 6. O040600800024 10.22 193. 7. O040600800025 11.02 201. 5. O040600800026 11.48 213. 6. O040600800027 11.74 172. 5. O040600800028 12.55 176. 7. O040600800029 12.91 166. 5. O040600800030 13.49 165. 5. O040600800031 13.86 144. 7. O040600800032 14.3 168. 7. O040600800033 14.79 148. 5. O040600800034 15.48 153. 5. O040600800035 16.08 136. 7. O040600800036 16.34 114. 7. O040600800037 16.79 119. 6. O040600800038 17.38 118. 7. O040600800039 17.83 123. 7. O040600800040 18.31 115. 8. O040600800041 18.89 111. 7. O040600800042 19.25 106. 7. O040600800043 19.95 103. 8. O040600800044 20.22 81. 9. O040600800045 20.89 94. 7. O040600800046 21.5 81. 9. O040600800047 21.86 76. 8. O040600800048 22.18 87. 8. O040600800049 23.01 79. 9. O040600800050 ENDDATA 34 0 O040600800051 ENDSUBENT 50 0 O040600899999 SUBENT O0406009 20120527 O048O040600900001 BIB 5 7 O040600900002 REACTION (50-SN-124(P,X)2-HE-3,,DA/DE,,REL) Fig.2B/4 O040600900003 SAMPLE (50-SN-124,ENR=0.953) target was metal foil of O040600900004 chemically pure separated nickel; 8.084 mg/cm2 thick O040600900005 EN-SEC (E,HE3) O040600900006 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040600900007 (E-ERR-DIG).Data-point reader uncertainty. O040600900008 STATUS (CURVE).By CAJAD from Fig.2b/4 of YF,19,32,1974 O040600900009 ENDBIB 7 0 O040600900010 COMMON 2 3 O040600900011 ANG E-ERR-DIG O040600900012 ADEG MEV O040600900013 90. 0.16 O040600900014 ENDCOMMON 3 0 O040600900015 DATA 3 33 O040600900016 E DATA DATA-ERR O040600900017 MEV ARB-UNITS PER-CENT O040600900018 6.98 69. 9. O040600900019 7.06 41. 12. O040600900020 7.45 63. 10. O040600900021 7.87 82. 10. O040600900022 8.32 86. 9. O040600900023 9. 86. 10. O040600900024 9.43 106. 8. O040600900025 9.89 102. 9. O040600900026 10.24 102. 8. O040600900027 10.91 115. 10. O040600900028 11.49 107. 7. O040600900029 11.85 101. 9. O040600900030 12.21 91. 9. O040600900031 13.01 91. 9. O040600900032 13.38 80. 9. O040600900033 13.82 85. 9. O040600900034 14.25 101. 9. O040600900035 14.86 84. 10. O040600900036 15.24 67. 10. O040600900037 16.14 75. 9. O040600900038 16.28 65. 9. O040600900039 16.85 66. 11. O040600900040 17.22 56. 11. O040600900041 17.77 65. 11. O040600900042 18.34 63. 11. O040600900043 18.82 58. 10. O040600900044 19.41 50. 12. O040600900045 19.84 62. 11. O040600900046 20.33 49. 6. O040600900047 20.67 51. 8. O040600900048 21.25 50. 10. O040600900049 21.71 48. 8. O040600900050 22.3 46. 11. O040600900051 ENDDATA 35 0 O040600900052 ENDSUBENT 51 0 O040600999999 SUBENT O0406010 20120527 O048O040601000001 BIB 6 13 O040601000002 REACTION ((28-NI-58(P,X)2-HE-4,,DA/DE)/ O040601000003 (28-NI-64(P,X)2-HE-4,,DA/DE)) O040601000004 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601000005 chemically pure separated nickel; 8.133 mg/cm2 thick O040601000006 (28-NI-64,ENR=0.898) target was metal foil of O040601000007 chemically pure separated nickel; 9.678 mg/cm2 thick O040601000008 EN-SEC (E,A) O040601000009 COMMENT - By Compiler - These data are presented on figure 4 O040601000010 too, but data points on figure 4 are different from O040601000011 the data in figure 3. Difference reason is unknown. O040601000012 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040601000013 (E-ERR-DIG).Data-point reader uncertainty. O040601000014 STATUS (CURVE).By CAJAD from Fig.3/2 of YF,19,32,1974 O040601000015 ENDBIB 13 0 O040601000016 COMMON 2 3 O040601000017 ANG E-ERR-DIG O040601000018 ADEG MEV O040601000019 90. 0.16 O040601000020 ENDCOMMON 3 0 O040601000021 DATA 3 15 O040601000022 E DATA DATA-ERR O040601000023 MEV NO-DIM NO-DIM O040601000024 4.22 1.33 4.E-02 O040601000025 6.01 1.28 3.E-02 O040601000026 8.13 1.28 3.E-02 O040601000027 10.26 1.24 4.E-02 O040601000028 12.16 1.22 5.E-02 O040601000029 14.17 1.15 5.E-02 O040601000030 16.07 1.07 5.E-02 O040601000031 18.2 1.16 6.E-02 O040601000032 20.32 1.13 7.E-02 O040601000033 22.23 1.17 9.E-02 O040601000034 24.24 1.06 9.E-02 O040601000035 26.36 0.88 9.E-02 O040601000036 28.04 0.9 9.E-02 O040601000037 30.06 0.92 9.E-02 O040601000038 32.29 0.92 0.11 O040601000039 ENDDATA 17 0 O040601000040 ENDSUBENT 39 0 O040601099999 SUBENT O0406011 20120527 O048O040601100001 BIB 5 10 O040601100002 REACTION ((50-SN-112(P,X)2-HE-4,,DA/DE)/ O040601100003 (50-SN-124(P,X)2-HE-4,,DA/DE)) O040601100004 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040601100005 chemically pure separated nickel; 8.347 mg/cm2 thick O040601100006 (50-SN-124,ENR=0.953) target was metal foil of O040601100007 chemically pure separated nickel; 8.084 mg/cm2 thick O040601100008 EN-SEC (E,A) O040601100009 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040601100010 (E-ERR-DIG).Data-point reader uncertainty. O040601100011 STATUS (CURVE).By CAJAD from Fig.3/1 of YF,19,32,1974 O040601100012 ENDBIB 10 0 O040601100013 COMMON 2 3 O040601100014 ANG E-ERR-DIG O040601100015 ADEG MEV O040601100016 90. 0.16 O040601100017 ENDCOMMON 3 0 O040601100018 DATA 3 13 O040601100019 E DATA DATA-ERR O040601100020 MEV NO-DIM NO-DIM O040601100021 8.44 1.77 4.E-02 O040601100022 10.44 1.75 3.E-02 O040601100023 12.33 1.62 3.E-02 O040601100024 14.11 1.5 4.E-02 O040601100025 16.11 1.417 3.E-02 O040601100026 18.44 1.35 5.E-02 O040601100027 20.22 1.3 4.E-02 O040601100028 22.33 1.31 6.E-02 O040601100029 24.22 1.21 6.E-02 O040601100030 26.33 1.15 7.E-02 O040601100031 28.33 1.23 8.E-02 O040601100032 30.22 1.16 8.E-02 O040601100033 32.11 1.12 8.E-02 O040601100034 ENDDATA 15 0 O040601100035 ENDSUBENT 34 0 O040601199999 SUBENT O0406012 20120527 O048O040601200001 BIB 5 10 O040601200002 REACTION ((28-NI-58(P,X)2-HE-4,,DA/DE)/ O040601200003 (28-NI-64(P,X)2-HE-4,,DA/DE)) Fig. 4/1 O040601200004 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601200005 chemically pure separated nickel; 8.133 mg/cm2 thick O040601200006 (28-NI-64,ENR=0.898) target was metal foil of O040601200007 chemically pure separated nickel; 9.678 mg/cm2 thick O040601200008 EN-SEC (E,A) O040601200009 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040601200010 (E-ERR-DIG).Data-point reader uncertainty. O040601200011 STATUS (CURVE).By CAJAD from Fig.4/1 of YF,19,32,1974 O040601200012 ENDBIB 10 0 O040601200013 COMMON 2 3 O040601200014 ANG E-ERR-DIG O040601200015 ADEG MEV O040601200016 150. 0.21 O040601200017 ENDCOMMON 3 0 O040601200018 DATA 3 6 O040601200019 E DATA DATA-ERR O040601200020 MEV NO-DIM NO-DIM O040601200021 4.87 1.34 0.12 O040601200022 7. 1.3 7.E-02 O040601200023 8.96 1.29 7.E-02 O040601200024 10.91 1.3 7.E-02 O040601200025 13.11 1.13 8.E-02 O040601200026 15.05 1.15 0.13 O040601200027 ENDDATA 8 0 O040601200028 ENDSUBENT 27 0 O040601299999 SUBENT O0406013 20120527 O048O040601300001 BIB 5 10 O040601300002 REACTION ((28-NI-58(P,X)2-HE-4,,DA/DE)/ O040601300003 (28-NI-64(P,X)2-HE-4,,DA/DE)) O040601300004 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601300005 chemically pure separated nickel; 8.133 mg/cm2 thick O040601300006 (28-NI-64,ENR=0.898) target was metal foil of O040601300007 chemically pure separated nickel; 9.678 mg/cm2 thick O040601300008 EN-SEC (E,A) O040601300009 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040601300010 (E-ERR-DIG).Data-point reader uncertainty. O040601300011 STATUS (CURVE).By CAJAD from Fig.4/2 of YF,19,32,1974 O040601300012 ENDBIB 10 0 O040601300013 COMMON 2 3 O040601300014 ANG E-ERR-DIG O040601300015 ADEG MEV O040601300016 120. 0.21 O040601300017 ENDCOMMON 3 0 O040601300018 DATA 3 6 O040601300019 E DATA DATA-ERR O040601300020 MEV NO-DIM NO-DIM O040601300021 5.23 1.36 5.E-02 O040601300022 7.34 1.297 1.7E-02 O040601300023 9.72 1.288 1.E-02 O040601300024 11.52 1.254 1.4E-02 O040601300025 13.61 1.227 1.5E-02 O040601300026 15.25 1.22 3.E-02 O040601300027 ENDDATA 8 0 O040601300028 ENDSUBENT 27 0 O040601399999 SUBENT O0406014 20120527 O048O040601400001 BIB 5 10 O040601400002 REACTION ((28-NI-58(P,X)2-HE-4,,DA/DE)/ O040601400003 (28-NI-64(P,X)2-HE-4,,DA/DE)) O040601400004 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601400005 chemically pure separated nickel; 8.133 mg/cm2 thick O040601400006 (28-NI-64,ENR=0.898) target was metal foil of O040601400007 chemically pure separated nickel; 9.678 mg/cm2 thick O040601400008 EN-SEC (E,A) O040601400009 ERR-ANALYS (DATA-ERR).The Uncertainty from error bars on fig. O040601400010 (E-ERR-DIG).Data-point reader uncertainty. O040601400011 STATUS (CURVE).By CAJAD from Fig.4/4 of YF,19,32,1974 O040601400012 ENDBIB 10 0 O040601400013 COMMON 2 3 O040601400014 ANG E-ERR-DIG O040601400015 ADEG MEV O040601400016 60. 0.21 O040601400017 ENDCOMMON 3 0 O040601400018 DATA 3 14 O040601400019 E DATA DATA-ERR O040601400020 MEV NO-DIM NO-DIM O040601400021 4.93 1.29 6.E-02 O040601400022 6.96 1.16 4.E-02 O040601400023 9.1 1.1 4.E-02 O040601400024 11.03 1.14 4.E-02 O040601400025 12.98 1.15 4.E-02 O040601400026 14.95 1.12 4.E-02 O040601400027 16.91 1.12 5.E-02 O040601400028 18.93 0.98 5.E-02 O040601400029 20.98 1.09 8.E-02 O040601400030 22.94 1.08 9.E-02 O040601400031 25.26 0.96 8.E-02 O040601400032 27.07 0.94 8.E-02 O040601400033 29.42 1.06 8.E-02 O040601400034 31.29 0.93 0.1 O040601400035 ENDDATA 16 0 O040601400036 ENDSUBENT 35 0 O040601499999 SUBENT O0406015 20120527 O048O040601500001 BIB 5 17 O040601500002 REACTION 1(28-NI-58(P,X)1-H-2,PAR,DA) O040601500003 2(28-NI-64(P,X)1-H-2,PAR,DA) O040601500004 3((28-NI-58(P,X)1-H-2,PAR,DA)/ O040601500005 (28-NI-64(P,X)1-H-2,PAR,DA)) O040601500006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601500007 chemically pure separated nickel; 8.133 mg/cm2 thick O040601500008 (28-NI-64,ENR=0.898) target was metal foil of O040601500009 chemically pure separated nickel; 9.678 mg/cm2 thick O040601500010 EN-SEC (E-MIN,D) O040601500011 (E-MAX,D) O040601500012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040601500013 sections comprise about 10%, including the errors of O040601500014 the monitoring reactions O040601500015 (ERR-S) Statistical errors. The deviations of all O040601500016 measurements from their means lie within the limits of O040601500017 the statistical errors given in the table O040601500018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040601500019 ENDBIB 17 0 O040601500020 COMMON 4 3 O040601500021 E-MIN E-MAX ANG ERR-T O040601500022 MEV MEV ADEG PER-CENT O040601500023 5. 14. 90. 10. O040601500024 ENDCOMMON 3 0 O040601500025 DATA 6 1 O040601500026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040601500027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040601500028 9.71 0.28 8.49 0.24 1.14 0.05O040601500029 ENDDATA 3 0 O040601500030 ENDSUBENT 29 0 O040601599999 SUBENT O0406016 20120527 O048O040601600001 BIB 5 17 O040601600002 REACTION 1(28-NI-58(P,X)1-H-3,PAR,DA) O040601600003 2(28-NI-64(P,X)1-H-3,PAR,DA) O040601600004 3((28-NI-58(P,X)1-H-3,PAR,DA)/ O040601600005 (28-NI-64(P,X)1-H-3,PAR,DA)) O040601600006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601600007 chemically pure separated nickel; 8.133 mg/cm2 thick O040601600008 (28-NI-64,ENR=0.898) target was metal foil of O040601600009 chemically pure separated nickel; 9.678 mg/cm2 thick O040601600010 EN-SEC (E-MIN,T) O040601600011 (E-MAX,T) O040601600012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040601600013 sections comprise about 10%, including the errors of O040601600014 the monitoring reactions O040601600015 (ERR-S) Statistical errors. The deviations of all O040601600016 measurements from their means lie within the limits of O040601600017 the statistical errors given in the table O040601600018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040601600019 ENDBIB 17 0 O040601600020 COMMON 4 3 O040601600021 E-MIN E-MAX ANG ERR-T O040601600022 MEV MEV ADEG PER-CENT O040601600023 5. 17. 90. 10. O040601600024 ENDCOMMON 3 0 O040601600025 DATA 6 1 O040601600026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040601600027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040601600028 4.64 0.14 7.06 0.24 0.66 0.03O040601600029 ENDDATA 3 0 O040601600030 ENDSUBENT 29 0 O040601699999 SUBENT O0406017 20120527 O048O040601700001 BIB 5 17 O040601700002 REACTION 1(28-NI-58(P,X)2-HE-3,PAR,DA) O040601700003 2(28-NI-64(P,X)2-HE-3,PAR,DA) O040601700004 3((28-NI-58(P,X)2-HE-3,PAR,DA)/ O040601700005 (28-NI-64(P,X)2-HE-3,PAR,DA)) O040601700006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601700007 chemically pure separated nickel; 8.133 mg/cm2 thick O040601700008 (28-NI-64,ENR=0.898) target was metal foil of O040601700009 chemically pure separated nickel; 9.678 mg/cm2 thick O040601700010 EN-SEC (E-MIN,HE3) O040601700011 (E-MAX,HE3) O040601700012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040601700013 sections comprise about 10%, including the errors of O040601700014 the monitoring reactions O040601700015 (ERR-S) Statistical errors. The deviations of all O040601700016 measurements from their means lie within the limits of O040601700017 the statistical errors given in the table O040601700018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040601700019 ENDBIB 17 0 O040601700020 COMMON 4 3 O040601700021 E-MIN E-MAX ANG ERR-T O040601700022 MEV MEV ADEG PER-CENT O040601700023 7. 32. 90. 10. O040601700024 ENDCOMMON 3 0 O040601700025 DATA 6 1 O040601700026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040601700027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040601700028 6.05 0.14 3.96 0.12 1.52 0.08O040601700029 ENDDATA 3 0 O040601700030 ENDSUBENT 29 0 O040601799999 SUBENT O0406018 20120527 O048O040601800001 BIB 5 17 O040601800002 REACTION 1(28-NI-58(P,X)2-HE-4,PAR,DA) O040601800003 2(28-NI-64(P,X)2-HE-4,PAR,DA) O040601800004 3((28-NI-58(P,X)2-HE-4,PAR,DA)/ O040601800005 (28-NI-64(P,X)2-HE-4,PAR,DA)) O040601800006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601800007 chemically pure separated nickel; 8.133 mg/cm2 thick O040601800008 (28-NI-64,ENR=0.898) target was metal foil of O040601800009 chemically pure separated nickel; 9.678 mg/cm2 thick O040601800010 EN-SEC (E-MIN,A) O040601800011 (E-MAX,A) O040601800012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040601800013 sections comprise about 10%, including the errors of O040601800014 the monitoring reactions O040601800015 (ERR-S) Statistical errors. The deviations of all O040601800016 measurements from their means lie within the limits of O040601800017 the statistical errors given in the table O040601800018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040601800019 ENDBIB 17 0 O040601800020 COMMON 4 3 O040601800021 E-MIN E-MAX ANG ERR-T O040601800022 MEV MEV ADEG PER-CENT O040601800023 8. 33. 90. 10. O040601800024 ENDCOMMON 3 0 O040601800025 DATA 6 1 O040601800026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040601800027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040601800028 28.1 0.3 24. 0.3 1.17 0.03O040601800029 ENDDATA 3 0 O040601800030 ENDSUBENT 29 0 O040601899999 SUBENT O0406019 20120527 O048O040601900001 BIB 6 19 O040601900002 REACTION 1(28-NI-58(P,X)2-HE-6,PAR,DA) O040601900003 2(28-NI-64(P,X)2-HE-6,PAR,DA) O040601900004 3((28-NI-58(P,X)2-HE-6,PAR,DA)/ O040601900005 (28-NI-64(P,X)2-HE-6,PAR,DA)) O040601900006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040601900007 chemically pure separated nickel; 8.133 mg/cm2 thick O040601900008 (28-NI-64,ENR=0.898) target was metal foil of O040601900009 chemically pure separated nickel; 9.678 mg/cm2 thick O040601900010 EN-SEC (E-MIN,2-HE-6) O040601900011 (E-MAX,2-HE-6) O040601900012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040601900013 sections comprise about 10%, including the errors of O040601900014 the monitoring reactions O040601900015 (ERR-S) Statistical errors. The deviations of all O040601900016 measurements from their means lie within the limits of O040601900017 the statistical errors given in the table O040601900018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040601900019 HISTORY (20120527A) SD: DATA-MAX => DATA-APRX as it is given inO040601900020 the Table 1 of YF,19,32,1974 O040601900021 ENDBIB 19 0 O040601900022 COMMON 4 3 O040601900023 E-MIN E-MAX ANG ERR-T O040601900024 MEV MEV ADEG PER-CENT O040601900025 8. 33. 90. 10. O040601900026 ENDCOMMON 3 0 O040601900027 DATA 4 1 O040601900028 DATA-APRX 1DATA-APRX 2DATA 3ERR-S 3 O040601900029 MB/SR MB/SR NO-DIM NO-DIM O040601900030 0.22 0.44 0.5 0.1 O040601900031 ENDDATA 3 0 O040601900032 ENDSUBENT 31 0 O040601999999 SUBENT O0406020 20120527 O048O040602000001 BIB 5 17 O040602000002 REACTION 1(28-NI-58(P,X)3-LI-6,PAR,DA) O040602000003 2(28-NI-64(P,X)3-LI-6,PAR,DA) O040602000004 3((28-NI-58(P,X)3-LI-6,PAR,DA)/ O040602000005 (28-NI-64(P,X)3-LI-6,PAR,DA)) O040602000006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040602000007 chemically pure separated nickel; 8.133 mg/cm2 thick O040602000008 (28-NI-64,ENR=0.898) target was metal foil of O040602000009 chemically pure separated nickel; 9.678 mg/cm2 thick O040602000010 EN-SEC (E-MIN,3-LI-6) O040602000011 (E-MAX,3-LI-6) O040602000012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602000013 sections comprise about 10%, including the errors of O040602000014 the monitoring reactions O040602000015 (ERR-S) Statistical errors. The deviations of all O040602000016 measurements from their means lie within the limits of O040602000017 the statistical errors given in the table O040602000018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040602000019 ENDBIB 17 0 O040602000020 COMMON 4 3 O040602000021 E-MIN E-MAX ANG ERR-T O040602000022 MEV MEV ADEG PER-CENT O040602000023 9.5 34. 90. 10. O040602000024 ENDCOMMON 3 0 O040602000025 DATA 6 1 O040602000026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602000027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602000028 0.79 0.04 0.59 0.03 1.34 0.13O040602000029 ENDDATA 3 0 O040602000030 ENDSUBENT 29 0 O040602099999 SUBENT O0406021 20120527 O048O040602100001 BIB 5 17 O040602100002 REACTION 1(28-NI-58(P,X)3-LI-7,PAR,DA) O040602100003 2(28-NI-64(P,X)3-LI-7,PAR,DA) O040602100004 3((28-NI-58(P,X)3-LI-7,PAR,DA)/ O040602100005 (28-NI-64(P,X)3-LI-7,PAR,DA)) O040602100006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040602100007 chemically pure separated nickel; 8.133 mg/cm2 thick O040602100008 (28-NI-64,ENR=0.898) target was metal foil of O040602100009 chemically pure separated nickel; 9.678 mg/cm2 thick O040602100010 EN-SEC (E-MIN,3-LI-7) O040602100011 (E-MAX,3-LI-7) O040602100012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602100013 sections comprise about 10%, including the errors of O040602100014 the monitoring reactions O040602100015 (ERR-S) Statistical errors. The deviations of all O040602100016 measurements from their means lie within the limits of O040602100017 the statistical errors given in the table O040602100018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040602100019 ENDBIB 17 0 O040602100020 COMMON 4 3 O040602100021 E-MIN E-MAX ANG ERR-T O040602100022 MEV MEV ADEG PER-CENT O040602100023 9.5 34. 90. 10. O040602100024 ENDCOMMON 3 0 O040602100025 DATA 6 1 O040602100026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602100027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602100028 0.32 0.02 0.37 0.02 0.87 0.12O040602100029 ENDDATA 3 0 O040602100030 ENDSUBENT 29 0 O040602199999 SUBENT O0406022 20120527 O048O040602200001 BIB 6 16 O040602200002 REACTION ((28-NI-58(P,X)3-LI-8,PAR,DA)/ O040602200003 (28-NI-64(P,X)3-LI-8,PAR,DA)) O040602200004 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040602200005 chemically pure separated nickel; 8.133 mg/cm2 thick O040602200006 (28-NI-64,ENR=0.898) target was metal foil of O040602200007 chemically pure separated nickel; 9.678 mg/cm2 thick O040602200008 EN-SEC (E-MIN,3-LI-8) O040602200009 DETECTOR (PLATE) The ratio for 8Li was obtained by using nuclearO040602200010 emulsions as detectors in the reaction chamber; this O040602200011 enabled to obtain the ratio of 8Li production cross O040602200012 sections from 58Ni and 64Ni practically without a O040602200013 low-energy cutoff O040602200014 ERR-ANALYS (ERR-S) Statistical errors. The deviations of all O040602200015 measurements from their means lie within the limits of O040602200016 the statistical errors given in the table O040602200017 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040602200018 ENDBIB 16 0 O040602200019 NOCOMMON 0 0 O040602200020 DATA 4 1 O040602200021 E-MIN ANG DATA ERR-S O040602200022 MEV ADEG NO-DIM NO-DIM O040602200023 2. 90. 0.52 0.1 O040602200024 ENDDATA 3 0 O040602200025 ENDSUBENT 24 0 O040602299999 SUBENT O0406023 20120527 O048O040602300001 BIB 5 17 O040602300002 REACTION 1(28-NI-58(P,X)4-BE-7,PAR,DA) O040602300003 2(28-NI-64(P,X)4-BE-7,PAR,DA) O040602300004 3((28-NI-58(P,X)4-BE-7,PAR,DA)/ O040602300005 (28-NI-64(P,X)4-BE-7,PAR,DA)) O040602300006 SAMPLE (28-NI-58,ENR=0.953) target was metal foil of O040602300007 chemically pure separated nickel; 8.133 mg/cm2 thick O040602300008 (28-NI-64,ENR=0.898) target was metal foil of O040602300009 chemically pure separated nickel; 9.678 mg/cm2 thick O040602300010 EN-SEC (E-MIN,4-BE-7) O040602300011 (E-MAX,4-BE-7) O040602300012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602300013 sections comprise about 10%, including the errors of O040602300014 the monitoring reactions O040602300015 (ERR-S) Statistical errors. The deviations of all O040602300016 measurements from their means lie within the limits of O040602300017 the statistical errors given in the table O040602300018 STATUS (TABLE) Tbl.1 from YF,19,32,1974 O040602300019 ENDBIB 17 0 O040602300020 COMMON 4 3 O040602300021 E-MIN E-MAX ANG ERR-T O040602300022 MEV MEV ADEG PER-CENT O040602300023 11. 36. 90. 10. O040602300024 ENDCOMMON 3 0 O040602300025 DATA 6 1 O040602300026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602300027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602300028 0.23 0.02 0.104 0.01 2.2 0.5O040602300029 ENDDATA 3 0 O040602300030 ENDSUBENT 29 0 O040602399999 SUBENT O0406024 20120527 O048O040602400001 BIB 5 17 O040602400002 REACTION 1(50-SN-112(P,X)1-H-2,PAR,DA) O040602400003 2(50-SN-124(P,X)1-H-2,PAR,DA) O040602400004 3((50-SN-112(P,X)1-H-2,PAR,DA)/ O040602400005 (50-SN-124(P,X)1-H-2,PAR,DA)) O040602400006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602400007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602400008 (50-SN-124,ENR=0.953) target was metal foil of O040602400009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602400010 EN-SEC (E-MIN,D) O040602400011 (E-MAX,D) O040602400012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602400013 sections comprise about 10%, including the errors of O040602400014 the monitoring reactions O040602400015 (ERR-S) Statistical errors. The deviations of all O040602400016 measurements from their means lie within the limits of O040602400017 the statistical errors given in the table O040602400018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602400019 ENDBIB 17 0 O040602400020 COMMON 4 3 O040602400021 E-MIN E-MAX ANG ERR-T O040602400022 MEV MEV ADEG PER-CENT O040602400023 5. 14. 90. 10. O040602400024 ENDCOMMON 3 0 O040602400025 DATA 6 1 O040602400026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602400027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602400028 14.2 0.5 11.34 0.6 1.25 0.13O040602400029 ENDDATA 3 0 O040602400030 ENDSUBENT 29 0 O040602499999 SUBENT O0406025 20120527 O048O040602500001 BIB 5 17 O040602500002 REACTION 1(50-SN-112(P,X)1-H-3,PAR,DA) O040602500003 2(50-SN-124(P,X)1-H-3,PAR,DA) O040602500004 3((50-SN-112(P,X)1-H-3,PAR,DA)/ O040602500005 (50-SN-124(P,X)1-H-3,PAR,DA)) O040602500006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602500007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602500008 (50-SN-124,ENR=0.953) target was metal foil of O040602500009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602500010 EN-SEC (E-MIN,T) O040602500011 (E-MAX,T) O040602500012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602500013 sections comprise about 10%, including the errors of O040602500014 the monitoring reactions O040602500015 (ERR-S) Statistical errors. The deviations of all O040602500016 measurements from their means lie within the limits of O040602500017 the statistical errors given in the table O040602500018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602500019 ENDBIB 17 0 O040602500020 COMMON 4 3 O040602500021 E-MIN E-MAX ANG ERR-T O040602500022 MEV MEV ADEG PER-CENT O040602500023 5. 17. 90. 10. O040602500024 ENDCOMMON 3 0 O040602500025 DATA 6 1 O040602500026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602500027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602500028 11.05 0.19 14.53 0.7 0.76 0.06O040602500029 ENDDATA 3 0 O040602500030 ENDSUBENT 29 0 O040602599999 SUBENT O0406026 20120527 O048O040602600001 BIB 5 17 O040602600002 REACTION 1(50-SN-112(P,X)2-HE-3,PAR,DA) O040602600003 2(50-SN-124(P,X)2-HE-3,PAR,DA) O040602600004 3((50-SN-112(P,X)2-HE-3,PAR,DA)/ O040602600005 (50-SN-124(P,X)2-HE-3,PAR,DA)) O040602600006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602600007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602600008 (50-SN-124,ENR=0.953) target was metal foil of O040602600009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602600010 EN-SEC (E-MIN,HE3) O040602600011 (E-MAX,HE3) O040602600012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602600013 sections comprise about 10%, including the errors of O040602600014 the monitoring reactions O040602600015 (ERR-S) Statistical errors. The deviations of all O040602600016 measurements from their means lie within the limits of O040602600017 the statistical errors given in the table O040602600018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602600019 ENDBIB 17 0 O040602600020 COMMON 4 3 O040602600021 E-MIN E-MAX ANG ERR-T O040602600022 MEV MEV ADEG PER-CENT O040602600023 7. 32. 90. 10. O040602600024 ENDCOMMON 3 0 O040602600025 DATA 6 1 O040602600026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602600027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602600028 14.03 0.14 8.11 0.13 1.73 0.17O040602600029 ENDDATA 3 0 O040602600030 ENDSUBENT 29 0 O040602699999 SUBENT O0406027 20120527 O048O040602700001 BIB 5 17 O040602700002 REACTION 1(50-SN-112(P,X)2-HE-4,PAR,DA) O040602700003 2(50-SN-124(P,X)2-HE-4,PAR,DA) O040602700004 3((50-SN-112(P,X)2-HE-4,PAR,DA)/ O040602700005 (50-SN-124(P,X)2-HE-4,PAR,DA)) O040602700006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602700007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602700008 (50-SN-124,ENR=0.953) target was metal foil of O040602700009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602700010 EN-SEC (E-MIN,A) O040602700011 (E-MAX,A) O040602700012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602700013 sections comprise about 10%, including the errors of O040602700014 the monitoring reactions O040602700015 (ERR-S) Statistical errors. The deviations of all O040602700016 measurements from their means lie within the limits of O040602700017 the statistical errors given in the table O040602700018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602700019 ENDBIB 17 0 O040602700020 COMMON 4 3 O040602700021 E-MIN E-MAX ANG ERR-T O040602700022 MEV MEV ADEG PER-CENT O040602700023 8. 33. 90. 10. O040602700024 ENDCOMMON 3 0 O040602700025 DATA 6 1 O040602700026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-T 3O040602700027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602700028 161.5 1. 99.5 0.5 1.62 0.05O040602700029 ENDDATA 3 0 O040602700030 ENDSUBENT 29 0 O040602799999 SUBENT O0406028 20120527 O048O040602800001 BIB 5 17 O040602800002 REACTION 1(50-SN-112(P,X)2-HE-6,PAR,DA) O040602800003 2(50-SN-124(P,X)2-HE-6,PAR,DA) O040602800004 3((50-SN-112(P,X)2-HE-6,PAR,DA)/ O040602800005 (50-SN-124(P,X)2-HE-6,PAR,DA)) O040602800006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602800007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602800008 (50-SN-124,ENR=0.953) target was metal foil of O040602800009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602800010 EN-SEC (E-MIN,2-HE-6) O040602800011 (E-MAX,2-HE-6) O040602800012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602800013 sections comprise about 10%, including the errors of O040602800014 the monitoring reactions O040602800015 (ERR-S) Statistical errors. The deviations of all O040602800016 measurements from their means lie within the limits of O040602800017 the statistical errors given in the table O040602800018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602800019 ENDBIB 17 0 O040602800020 COMMON 4 3 O040602800021 E-MIN E-MAX ANG ERR-T O040602800022 MEV MEV ADEG PER-CENT O040602800023 8. 33. 90. 10. O040602800024 ENDCOMMON 3 0 O040602800025 DATA 4 1 O040602800026 DATA-MIN 1DATA-MIN 2DATA 3ERR-S 3 O040602800027 MB/SR MB/SR NO-DIM NO-DIM O040602800028 0.045 0.15 0.3 0.1 O040602800029 ENDDATA 3 0 O040602800030 ENDSUBENT 29 0 O040602899999 SUBENT O0406029 20120527 O048O040602900001 BIB 5 17 O040602900002 REACTION 1(50-SN-112(P,X)3-LI-6,PAR,DA) O040602900003 2(50-SN-124(P,X)3-LI-6,PAR,DA) O040602900004 3((50-SN-112(P,X)3-LI-6,PAR,DA)/ O040602900005 (50-SN-124(P,X)3-LI-6,PAR,DA)) O040602900006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040602900007 chemically pure separated nickel; 8.347 mg/cm2 thick O040602900008 (50-SN-124,ENR=0.953) target was metal foil of O040602900009 chemically pure separated nickel; 8.084 mg/cm2 thick O040602900010 EN-SEC (E-MIN,3-LI-6) O040602900011 (E-MAX,3-LI-6) O040602900012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040602900013 sections comprise about 10%, including the errors of O040602900014 the monitoring reactions O040602900015 (ERR-S) Statistical errors. The deviations of all O040602900016 measurements from their means lie within the limits of O040602900017 the statistical errors given in the table O040602900018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040602900019 ENDBIB 17 0 O040602900020 COMMON 4 3 O040602900021 E-MIN E-MAX ANG ERR-T O040602900022 MEV MEV ADEG PER-CENT O040602900023 16. 36. 90. 10. O040602900024 ENDCOMMON 3 0 O040602900025 DATA 6 1 O040602900026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040602900027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040602900028 0.452 0.01 0.358 0.01 1.26 0.07O040602900029 ENDDATA 3 0 O040602900030 ENDSUBENT 29 0 O040602999999 SUBENT O0406030 20120527 O048O040603000001 BIB 5 17 O040603000002 REACTION 1(50-SN-112(P,X)3-LI-7,PAR,DA) O040603000003 2(50-SN-124(P,X)3-LI-7,PAR,DA) O040603000004 3((50-SN-112(P,X)3-LI-7,PAR,DA)/ O040603000005 (50-SN-124(P,X)3-LI-7,PAR,DA)) O040603000006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040603000007 chemically pure separated nickel; 8.347 mg/cm2 thick O040603000008 (50-SN-124,ENR=0.953) target was metal foil of O040603000009 chemically pure separated nickel; 8.084 mg/cm2 thick O040603000010 EN-SEC (E-MIN,3-LI-7) O040603000011 (E-MAX,3-LI-7) O040603000012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040603000013 sections comprise about 10%, including the errors of O040603000014 the monitoring reactions O040603000015 (ERR-S) Statistical errors. The deviations of all O040603000016 measurements from their means lie within the limits of O040603000017 the statistical errors given in the table O040603000018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040603000019 ENDBIB 17 0 O040603000020 COMMON 4 3 O040603000021 E-MIN E-MAX ANG ERR-T O040603000022 MEV MEV ADEG PER-CENT O040603000023 16. 36. 90. 10. O040603000024 ENDCOMMON 3 0 O040603000025 DATA 6 1 O040603000026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040603000027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040603000028 0.337 0.01 0.527 0.01 0.64 0.04O040603000029 ENDDATA 3 0 O040603000030 ENDSUBENT 29 0 O040603099999 SUBENT O0406031 20120527 O048O040603100001 BIB 5 17 O040603100002 REACTION 1(50-SN-112(P,X)3-LI-8,PAR,DA) O040603100003 2(50-SN-124(P,X)3-LI-8,PAR,DA) O040603100004 3((50-SN-112(P,X)3-LI-8,PAR,DA)/ O040603100005 (50-SN-124(P,X)3-LI-8,PAR,DA)) O040603100006 SAMPLE (50-SN-112,ENR=0.799) target was metal foil of O040603100007 chemically pure separated nickel; 8.347 mg/cm2 thick O040603100008 (50-SN-124,ENR=0.953) target was metal foil of O040603100009 chemically pure separated nickel; 8.084 mg/cm2 thick O040603100010 EN-SEC (E-MIN,3-LI-8) O040603100011 (E-MAX,3-LI-8) O040603100012 ERR-ANALYS (ERR-T).The errors in determining absolute cross O040603100013 sections comprise about 10%, including the errors of O040603100014 the monitoring reactions O040603100015 (ERR-S) Statistical errors. The deviations of all O040603100016 measurements from their means lie within the limits of O040603100017 the statistical errors given in the table O040603100018 STATUS (TABLE) Tbl.2 from YF,19,32,1974 O040603100019 ENDBIB 17 0 O040603100020 COMMON 4 3 O040603100021 E-MIN E-MAX ANG ERR-T O040603100022 MEV MEV ADEG PER-CENT O040603100023 16. 36. 90. 10. O040603100024 ENDCOMMON 3 0 O040603100025 DATA 6 1 O040603100026 DATA 1ERR-S 1DATA 2ERR-S 2DATA 3ERR-S 3O040603100027 MB/SR MB/SR MB/SR MB/SR NO-DIM NO-DIM O040603100028 0.0343 0.003 0.098 0.006 0.35 0.06 O040603100029 ENDDATA 3 0 O040603100030 ENDSUBENT 29 0 O040603199999 ENDENTRY 31 0 O040699999999