ENTRY O0399 20020909 0000O039900000001 SUBENT O0399001 20020909 0000O039900100001 BIB 15 45 O039900100002 TITLE Production of Nuclides with Atomic Mass 43<=A<=51 O039900100003 In the Interaction of 1-28.5 GeV Protons with O039900100004 V, Ag, In, Pb and U Targets. O039900100005 AUTHOR (Y.Y.CHU, G.FRIEDLANDER, L.HUSAIN) O039900100006 INSTITUTE (1USABNL) O039900100007 REFERENCE (J,PR/C,15,352,1977) O039900100008 REL-REF (N,C0354001,J.R.GLOVER,J,PR,126,1540,1962) O039900100009 (N,,Y.Y.CHU+,J,NP/B,40,428,1972) O039900100010 Corrections For Secondary Particles. O039900100011 HISTORY (19980114C) O039900100012 (20020909A) Corrections For New Rules O039900100013 (20020909U) Last checking has been done. O039900100014 SAMPLE Standard Target Assemblies Consisted of a 25 Mum O039900100015 ( OR 50 MUM) Thick Target Foil Sandwiched Between Two O039900100016 Stacks of Three 25 Mum Aluminium Foils. O039900100017 For Vanadium, Silver and Indium Targets, Three Target O039900100018 Foils were Used, Only the Middle One Being Used For O039900100019 Chemical Processing and the Other Two Serving As Guard O039900100020 Foils. O039900100021 ADD-RES (COMP).The Measured Results and Total Isobaric Yields O039900100022 Evaluated by Using a Nonlinear Least Squares Program. O039900100023 FACILITY (SYNCY,1USABNL) The Brookhaven Cosmotron For 1, 2 and O039900100024 3 GeV. O039900100025 (SYNCH,1USABNL).The Brookhaven Alternating Gradient O039900100026 Synchrotron. O039900100027 METHOD (STTA) O039900100028 (CHSEP) O039900100029 (INTB) Irradiations were Performed in the Circulating O039900100030 Beams. The Lengths of Irradiations Ranged from Several O039900100031 Minutes to Two Hours. O039900100032 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) O039900100033 MONIT-REF (B0022001,J.B.CUMMING,J,ARN,13,261,1963) O039900100034 CORRECTION For the Contributions of Secondary Particles to 24-Na O039900100035 Production in the Monitor Foils were Made Only For Pb O039900100036 And U Targets at 3 and 28.5 GeV Proton Energies. O039900100037 Correction Factor Per 100 Milligramm/Cm**2 Target O039900100038 Thickness are 3.5% and 4% For Pb and U Targets at 3 O039900100039 GeV, respectively and 14% For Both Pb and U Targets at O039900100040 28.5 GeV. O039900100041 ERR-ANALYS (ERR-T) The Errors Quoted Include Counting Statistics, O039900100042 Uncertainties in Counter Efficiencies, Chemical Yield O039900100043 Determinations, and Summing Corrections. The O039900100044 Uncertainties of the Radiation Abundances and the O039900100045 Monitor Cross Sections are not Reflected Therein. O039900100046 STATUS (TABLE) O039900100047 ENDBIB 45 0 O039900100048 NOCOMMON 0 0 O039900100049 ENDSUBENT 48 0 O039900199999 SUBENT O0399002 20020909 0000O039900200001 BIB 4 4 O039900200002 REACTION (23-V-0(P,X)21-SC-43,CUM,SIG) O039900200003 RAD-DET (21-SC-43,AR) O039900200004 DETECTOR (GELI) O039900200005 DECAY-DATA (21-SC-43,3.89HR,AR,511.,1.76) O039900200006 ENDBIB 4 0 O039900200007 NOCOMMON 0 0 O039900200008 DATA 4 1 O039900200009 EN DATA ERR-T MONIT O039900200010 GEV MB MB MB O039900200011 28.5 2.18 0.22 8.6 O039900200012 ENDDATA 3 0 O039900200013 ENDSUBENT 12 0 O039900299999 SUBENT O0399003 20020909 0000O039900300001 BIB 5 7 O039900300002 REACTION (23-V-0(P,X)21-SC-44-G,IND,SIG) O039900300003 RAD-DET (21-SC-44-G,AR) O039900300004 (21-SC-44-G,DG) O039900300005 DECAY-DATA (21-SC-44-G,3.90HR,AR,511.,1.88,DG,1159.,1.) O039900300006 DETECTOR (GELI) O039900300007 COMMENT - By Compiler - Radioactive Decay of 44-Ti is O039900300008 Negligible. O039900300009 ENDBIB 7 0 O039900300010 NOCOMMON 0 0 O039900300011 DATA 4 1 O039900300012 EN DATA ERR-T MONIT O039900300013 GEV MB MB MB O039900300014 28.5 4.95 0.45 8.6 O039900300015 ENDDATA 3 0 O039900300016 ENDSUBENT 15 0 O039900399999 SUBENT O0399004 20020909 0000O039900400001 BIB 4 4 O039900400002 REACTION (23-V-0(P,X)21-SC-44-M,IND,SIG) O039900400003 DECAY-DATA (21-SC-44-M,2.44D,DG,271.,0.88) O039900400004 RAD-DET (21-SC-44-M,DG) O039900400005 DETECTOR (GELI) O039900400006 ENDBIB 4 0 O039900400007 NOCOMMON 0 0 O039900400008 DATA 4 1 O039900400009 EN DATA ERR-T MONIT O039900400010 GEV MB MB MB O039900400011 28.5 4.4 0.44 8.6 O039900400012 ENDDATA 3 0 O039900400013 ENDSUBENT 12 0 O039900499999 SUBENT O0399005 20020909 0000O039900500001 BIB 4 4 O039900500002 REACTION (23-V-0(P,X)21-SC-46-G,M+,SIG) Shielded. O039900500003 RAD-DET (21-SC-46-G,DG) O039900500004 DECAY-DATA (21-SC-46-G,83.9D,DG,889.,1.,DG,1120.,1.) O039900500005 DETECTOR (GELI) O039900500006 ENDBIB 4 0 O039900500007 NOCOMMON 0 0 O039900500008 DATA 4 1 O039900500009 EN DATA ERR-T MONIT O039900500010 GEV MB MB MB O039900500011 28.5 14.4 1.4 8.6 O039900500012 ENDDATA 3 0 O039900500013 ENDSUBENT 12 0 O039900599999 SUBENT O0399006 20020909 0000O039900600001 BIB 4 4 O039900600002 REACTION (23-V-0(P,X)21-SC-47,IND,SIG) O039900600003 RAD-DET (21-SC-47,DG) O039900600004 DECAY-DATA (21-SC-47,3.4D,DG,160.,0.7) O039900600005 DETECTOR (GELI) O039900600006 ENDBIB 4 0 O039900600007 NOCOMMON 0 0 O039900600008 DATA 4 1 O039900600009 EN DATA ERR-T MONIT O039900600010 GEV MB MB MB O039900600011 28.5 10.2 1. 8.6 O039900600012 ENDDATA 3 0 O039900600013 ENDSUBENT 12 0 O039900699999 SUBENT O0399007 20020909 0000O039900700001 BIB 4 6 O039900700002 REACTION (23-V-0(P,X)21-SC-48,,SIG) Shielded O039900700003 RAD-DET (21-SC-48,DG) O039900700004 DECAY-DATA (21-SC-48,43.67HR,DG,984.,1., O039900700005 DG,1038.,0.98, O039900700006 DG,1314.,1.) O039900700007 DETECTOR (GELI) O039900700008 ENDBIB 6 0 O039900700009 NOCOMMON 0 0 O039900700010 DATA 4 1 O039900700011 EN DATA ERR-T MONIT O039900700012 GEV MB MB MB O039900700013 28.5 4.32 0.43 8.6 O039900700014 ENDDATA 3 0 O039900700015 ENDSUBENT 14 0 O039900799999 SUBENT O0399008 20020909 0000O039900800001 BIB 4 4 O039900800002 REACTION (47-AG-0(P,X)21-SC-43,CUM,SIG) O039900800003 RAD-DET (21-SC-43,AR) O039900800004 DETECTOR (GELI) O039900800005 DECAY-DATA (21-SC-43,3.89HR,AR,511.,1.76) O039900800006 ENDBIB 4 0 O039900800007 NOCOMMON 0 0 O039900800008 DATA 4 3 O039900800009 EN DATA ERR-T MONIT O039900800010 GEV MB MB MB O039900800011 6. 0.72 0.08 8.7 O039900800012 18. 0.68 0.08 8.6 O039900800013 28.5 0.89 0.08 8.6 O039900800014 ENDDATA 5 0 O039900800015 ENDSUBENT 14 0 O039900899999 SUBENT O0399009 20020909 0000O039900900001 BIB 4 4 O039900900002 REACTION (47-AG-0(P,X)21-SC-44-G,IND,SIG) O039900900003 RAD-DET (21-SC-44-G,DG) O039900900004 DECAY-DATA (21-SC-44-G,3.90HR,AR,511.,1.88,DG,1159.,1.) O039900900005 DETECTOR (GELI) O039900900006 ENDBIB 4 0 O039900900007 NOCOMMON 0 0 O039900900008 DATA 4 2 O039900900009 EN DATA ERR-T MONIT O039900900010 GEV MB MB MB O039900900011 6. 1.07 0.1 8.7 O039900900012 28.5 1.21 0.12 8.6 O039900900013 ENDDATA 4 0 O039900900014 ENDSUBENT 13 0 O039900999999 SUBENT O0399010 20020909 0000O039901000001 BIB 4 4 O039901000002 REACTION (47-AG-0(P,X)21-SC-44-M,IND,SIG) O039901000003 RAD-DET (21-SC-44-M,DG) O039901000004 DECAY-DATA (21-SC-44-M,2.44D,DG,271.,0.88) O039901000005 DETECTOR (GELI) O039901000006 ENDBIB 4 0 O039901000007 NOCOMMON 0 0 O039901000008 DATA 4 4 O039901000009 EN DATA ERR-T MONIT O039901000010 GEV MB MB MB O039901000011 6. 2. 0.2 8.7 O039901000012 10. 1.88 0.2 8.6 O039901000013 18. 2.07 0.22 8.6 O039901000014 28.5 2.13 0.21 8.6 O039901000015 ENDDATA 6 0 O039901000016 ENDSUBENT 15 0 O039901099999 SUBENT O0399011 20020909 0000O039901100001 BIB 4 4 O039901100002 REACTION (47-AG-0(P,X)21-SC-46-G,M+,SIG) Shielded. O039901100003 RAD-DET (21-SC-46-G,DG) O039901100004 DECAY-DATA (21-SC-46-G,83.9D,DG,889.,1.,DG,1120.,1.) O039901100005 DETECTOR (GELI) O039901100006 ENDBIB 4 0 O039901100007 NOCOMMON 0 0 O039901100008 DATA 4 4 O039901100009 EN DATA ERR-T MONIT O039901100010 GEV MB MB MB O039901100011 6. 2.79 0.28 8.7 O039901100012 10. 2.79 0.3 8.6 O039901100013 18. 3.1 0.3 8.6 O039901100014 28.5 3.04 0.3 8.6 O039901100015 ENDDATA 6 0 O039901100016 ENDSUBENT 15 0 O039901199999 SUBENT O0399012 20020909 0000O039901200001 BIB 5 6 O039901200002 REACTION (47-AG-0(P,X)21-SC-47,IND,SIG) O039901200003 COMMENT - By Compiler - Method to Exclude 47-Sc Production Due O039901200004 To Radioactive Decay of 47-Ca is not Described. O039901200005 RAD-DET (21-SC-47,DG) O039901200006 DECAY-DATA (21-SC-47,3.4D,DG,160.,0.7) O039901200007 DETECTOR (GELI) O039901200008 ENDBIB 6 0 O039901200009 NOCOMMON 0 0 O039901200010 DATA 4 4 O039901200011 EN DATA ERR-T MONIT O039901200012 GEV MB MB MB O039901200013 6. 1.62 0.16 8.7 O039901200014 10. 1.56 0.16 8.6 O039901200015 18. 1.7 0.17 8.6 O039901200016 28.5 1.44 0.14 8.6 O039901200017 ENDDATA 6 0 O039901200018 ENDSUBENT 17 0 O039901299999 SUBENT O0399013 20020909 0000O039901300001 BIB 4 6 O039901300002 REACTION (47-AG-0(P,X)21-SC-48,,SIG) Shielded O039901300003 RAD-DET (21-SC-48,DG) O039901300004 DECAY-DATA (21-SC-48,43.67HR,DG,984.,1., O039901300005 DG,1038.,0.98, O039901300006 DG,1314.,1.) O039901300007 DETECTOR (GELI) O039901300008 ENDBIB 6 0 O039901300009 NOCOMMON 0 0 O039901300010 DATA 4 4 O039901300011 EN DATA ERR-T MONIT O039901300012 GEV MB MB MB O039901300013 6. 0.37 0.04 8.7 O039901300014 10. 0.37 0.05 8.6 O039901300015 18. 0.41 0.05 8.6 O039901300016 28.5 0.44 0.04 8.6 O039901300017 ENDDATA 6 0 O039901300018 ENDSUBENT 17 0 O039901399999 SUBENT O0399014 20020909 0000O039901400001 BIB 4 4 O039901400002 REACTION (49-IN-0(P,X)21-SC-43,CUM,SIG) O039901400003 RAD-DET (21-SC-43,AR) O039901400004 DETECTOR (GELI) O039901400005 DECAY-DATA (21-SC-43,3.89HR,AR,511.,1.76) O039901400006 ENDBIB 4 0 O039901400007 NOCOMMON 0 0 O039901400008 DATA 4 1 O039901400009 EN DATA ERR-T MONIT O039901400010 GEV MB MB MB O039901400011 28.5 0.57 0.06 8.6 O039901400012 ENDDATA 3 0 O039901400013 ENDSUBENT 12 0 O039901499999 SUBENT O0399015 20020909 0000O039901500001 BIB 4 5 O039901500002 REACTION (49-IN-0(P,X)21-SC-44-G,IND,SIG) O039901500003 RAD-DET (21-SC-44-G,AR) O039901500004 (21-SC-44-G,DG) O039901500005 DECAY-DATA (21-SC-44-G,3.90HR,AR,511.,1.88,DG,1159.,1.) O039901500006 DETECTOR (GELI) O039901500007 ENDBIB 5 0 O039901500008 NOCOMMON 0 0 O039901500009 DATA 4 1 O039901500010 EN DATA ERR-T MONIT O039901500011 GEV MB MB MB O039901500012 28.5 0.95 0.09 8.6 O039901500013 ENDDATA 3 0 O039901500014 ENDSUBENT 13 0 O039901599999 SUBENT O0399016 20020909 0000O039901600001 BIB 4 4 O039901600002 REACTION (49-IN-0(P,X)21-SC-44-M,IND,SIG) O039901600003 RAD-DET (21-SC-44-M,DG) O039901600004 DECAY-DATA (21-SC-44-M,2.44D,DG,271.,0.88) O039901600005 DETECTOR (GELI) O039901600006 ENDBIB 4 0 O039901600007 NOCOMMON 0 0 O039901600008 DATA 4 1 O039901600009 EN DATA ERR-T MONIT O039901600010 GEV MB MB MB O039901600011 28.5 1.62 0.16 8.6 O039901600012 ENDDATA 3 0 O039901600013 ENDSUBENT 12 0 O039901699999 SUBENT O0399017 20020909 0000O039901700001 BIB 4 4 O039901700002 REACTION (49-IN-0(P,X)21-SC-46-G,M+,SIG) Shielded. O039901700003 RAD-DET (21-SC-46-G,DG) O039901700004 DECAY-DATA (21-SC-46-G,83.9D,DG,889.,1.,DG,1120.,1.) O039901700005 DETECTOR (GELI) O039901700006 ENDBIB 4 0 O039901700007 NOCOMMON 0 0 O039901700008 DATA 4 1 O039901700009 EN DATA ERR-T MONIT O039901700010 GEV MB MB MB O039901700011 28.5 2.96 0.3 8.6 O039901700012 ENDDATA 3 0 O039901700013 ENDSUBENT 12 0 O039901799999 SUBENT O0399018 20020909 0000O039901800001 BIB 5 6 O039901800002 REACTION (49-IN-0(P,X)21-SC-47,IND,SIG) O039901800003 RAD-DET (21-SC-47,DG) O039901800004 DECAY-DATA (21-SC-47,3.4D,DG,160.,0.7) O039901800005 DETECTOR (GELI) O039901800006 COMMENT - By Compiler - Method to Exclude 47-Sc Production Due O039901800007 To Radioactive Decay of 47-Ca is not Described. O039901800008 ENDBIB 6 0 O039901800009 NOCOMMON 0 0 O039901800010 DATA 4 1 O039901800011 EN DATA ERR-T MONIT O039901800012 GEV MB MB MB O039901800013 28.5 1.59 0.16 8.6 O039901800014 ENDDATA 3 0 O039901800015 ENDSUBENT 14 0 O039901899999 SUBENT O0399019 20020909 0000O039901900001 BIB 4 6 O039901900002 REACTION (49-IN-0(P,X)21-SC-48,,SIG) Shielded O039901900003 RAD-DET (21-SC-48,DG) O039901900004 DECAY-DATA (21-SC-48,43.67HR,DG,984.,1., O039901900005 DG,1038.,0.98, O039901900006 DG,1314.,1.) O039901900007 DETECTOR (GELI) O039901900008 ENDBIB 6 0 O039901900009 NOCOMMON 0 0 O039901900010 DATA 4 1 O039901900011 EN DATA ERR-T MONIT O039901900012 GEV MB MB MB O039901900013 28.5 0.48 0.05 8.6 O039901900014 ENDDATA 3 0 O039901900015 ENDSUBENT 14 0 O039901999999 SUBENT O0399020 20020909 0000O039902000001 BIB 4 4 O039902000002 REACTION (82-PB-0(P,X)20-CA-45,CUM,SIG) O039902000003 RAD-DET (20-CA-45,B-) O039902000004 DETECTOR (PROPC) O039902000005 DECAY-DATA (20-CA-45,164.D,B-,257.,1.) O039902000006 ENDBIB 4 0 O039902000007 NOCOMMON 0 0 O039902000008 DATA 4 4 O039902000009 EN DATA ERR-T MONIT O039902000010 GEV MB MB MB O039902000011 1. 0.26 0.04 10.5 O039902000012 2. 0.62 0.1 9.5 O039902000013 3. 1.39 0.2 9.1 O039902000014 28.5 3.25 0.35 8.6 O039902000015 ENDDATA 6 0 O039902000016 ENDSUBENT 15 0 O039902099999 SUBENT O0399021 20020909 0000O039902100001 BIB 5 14 O039902100002 REACTION (82-PB-0(P,X)20-CA-47,CUM,SIG) O039902100003 RAD-DET (20-CA-47,DG) O039902100004 DECAY-DATA (20-CA-47,4.53D,DG,1297.,0.74) O039902100005 DETECTOR (GELI) O039902100006 (NAICR) O039902100007 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902100008 Targets at 1, 2, and 3 GeV were Made with Na-IO039902100009 Detectors and Most of the Later Measurements at 3 GeVO039902100010 And Higher were Made with Ge-Li Detectors. WheneverO039902100011 The Measurements were Repeated with Ge-Li Detectors,O039902100012 The Agreement with Earlier Result Using Na-I DetectorsO039902100013 Was Almost Always Within Experimental UncertaintiesO039902100014 +-15%, Thus Lending Confidence to All Earlier ResultsO039902100015 Obtained with Na-I Detectors. O039902100016 ENDBIB 14 0 O039902100017 NOCOMMON 0 0 O039902100018 DATA 4 4 O039902100019 EN DATA ERR-T MONIT O039902100020 GEV MB MB MB O039902100021 1. 0.068 0.01 10.5 O039902100022 2. 0.15 0.02 9.5 O039902100023 3. 0.26 0.04 9.1 O039902100024 28.5 0.56 0.06 8.6 O039902100025 ENDDATA 6 0 O039902100026 ENDSUBENT 25 0 O039902199999 SUBENT O0399022 20020909 0000O039902200001 BIB 4 11 O039902200002 REACTION (82-PB-0(P,X)21-SC-43,CUM,SIG) O039902200003 RAD-DET (21-SC-43,AR) O039902200004 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902200005 Targets at 1, 2, and 3 GeV were Made with Na-IO039902200006 Detectors and Most of the Later Measurements at 3 GeVO039902200007 And Higher were Made with Ge-Li Detectors. WheneverO039902200008 The Measurements were Repeated with Ge-Li Detectors,O039902200009 The Agreement with Earlier Result Using Na-I DetectorsO039902200010 Was Almost Always Within Experimental UncertaintiesO039902200011 +-15%, Thus Lending Confidence to All Earlier ResultsO039902200012 DECAY-DATA (21-SC-43,3.89HR,AR,511.,1.76) O039902200013 ENDBIB 11 0 O039902200014 NOCOMMON 0 0 O039902200015 DATA 4 3 O039902200016 EN DATA ERR-T MONIT O039902200017 GEV MB MB MB O039902200018 2. 0.18 0.07 9.5 O039902200019 3. 0.29 0.11 9.1 O039902200020 28.5 0.46 0.05 8.6 O039902200021 ENDDATA 5 0 O039902200022 ENDSUBENT 21 0 O039902299999 SUBENT O0399023 20020909 0000O039902300001 BIB 4 12 O039902300002 REACTION (82-PB-0(P,X)21-SC-44-G,IND,SIG) O039902300003 RAD-DET (21-SC-44-G,AR) O039902300004 (21-SC-44-G,DG) O039902300005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902300006 Targets at 1, 2, and 3 GeV were Made with Na-IO039902300007 Detectors and Most of the Later Measurements at 3 GeVO039902300008 And Higher were Made with Ge-Li Detectors. WheneverO039902300009 The Measurements were Repeated with Ge-Li Detectors,O039902300010 The Agreement with Earlier Result Using Na-I DetectorsO039902300011 Was Almost Always Within Experimental UncertaintiesO039902300012 +-15%, Thus Lending Confidence to All Earlier ResultsO039902300013 DECAY-DATA (21-SC-44-G,3.90HR,AR,511.,1.88,DG,1159.,1.) O039902300014 ENDBIB 12 0 O039902300015 NOCOMMON 0 0 O039902300016 DATA 4 3 O039902300017 EN DATA ERR-T MONIT O039902300018 GEV MB MB MB O039902300019 2. 0.06 0.03 9.5 O039902300020 3. 0.1 0.04 9.1 O039902300021 28.5 0.71 0.07 8.6 O039902300022 ENDDATA 5 0 O039902300023 ENDSUBENT 22 0 O039902399999 SUBENT O0399024 20020909 0000O039902400001 BIB 4 11 O039902400002 REACTION (82-PB-0(P,X)21-SC-44-M,IND,SIG) O039902400003 RAD-DET (21-SC-44-M,DG) O039902400004 DECAY-DATA (21-SC-44-M,2.44D,DG,271.,0.88) O039902400005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902400006 Targets at 1, 2, and 3 GeV were Made with Na-IO039902400007 Detectors and Most of the Later Measurements at 3 GeVO039902400008 And Higher were Made with Ge-Li Detectors. WheneverO039902400009 The Measurements were Repeated with Ge-Li Detectors,O039902400010 The Agreement with Earlier Result Using Na-I DetectorsO039902400011 Was Almost Always Within Experimental UncertaintiesO039902400012 +-15%, Thus Lending Confidence to All Earlier ResultsO039902400013 ENDBIB 11 0 O039902400014 NOCOMMON 0 0 O039902400015 DATA 4 4 O039902400016 EN DATA ERR-T MONIT O039902400017 GEV MB MB MB O039902400018 1. 0.08 0.02 10.5 O039902400019 2. 0.16 0.03 9.5 O039902400020 3. 0.47 0.09 9.1 O039902400021 28.5 1.21 0.13 8.6 O039902400022 ENDDATA 6 0 O039902400023 ENDSUBENT 22 0 O039902499999 SUBENT O0399025 20020909 0000O039902500001 BIB 4 11 O039902500002 REACTION (82-PB-0(P,X)21-SC-46-G,M+,SIG) Shielded. O039902500003 RAD-DET (21-SC-46-G,DG) O039902500004 DECAY-DATA (21-SC-46-G,83.9D,DG,889.,1.,DG,1120.,1.) O039902500005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902500006 Targets at 1, 2, and 3 GeV were Made with Na-IO039902500007 Detectors and Most of the Later Measurements at 3 GeVO039902500008 And Higher were Made with Ge-Li Detectors. WheneverO039902500009 The Measurements were Repeated with Ge-Li Detectors,O039902500010 The Agreement with Earlier Result Using Na-I DetectorsO039902500011 Was Almost Always Within Experimental UncertaintiesO039902500012 +-15%, Thus Lending Confidence to All Earlier ResultsO039902500013 ENDBIB 11 0 O039902500014 NOCOMMON 0 0 O039902500015 DATA 4 4 O039902500016 EN DATA ERR-T MONIT O039902500017 GEV MB MB MB O039902500018 1. 0.57 0.09 10.5 O039902500019 2. 0.75 0.11 9.5 O039902500020 3. 1.67 0.25 9.1 O039902500021 28.5 3.9 0.44 8.6 O039902500022 ENDDATA 6 0 O039902500023 ENDSUBENT 22 0 O039902599999 SUBENT O0399026 20020909 0000O039902600001 BIB 4 13 O039902600002 REACTION (82-PB-0(P,X)21-SC-47,IND,SIG) O039902600003 RAD-DET (21-SC-47,DG) O039902600004 DECAY-DATA (21-SC-47,3.4D,DG,160.,0.7) O039902600005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902600006 Targets at 1, 2, and 3 GeV were Made with Na-IO039902600007 Detectors and Most of the Later Measurements at 3 GeVO039902600008 And Higher were Made with Ge-Li Detectors. WheneverO039902600009 The Measurements were Repeated with Ge-Li Detectors,O039902600010 The Agreement with Earlier Result Using Na-I DetectorsO039902600011 Was Almost Always Within Experimental UncertaintiesO039902600012 +-15%, Thus Lending Confidence to All Earlier ResultsO039902600013 - By Compiler - Method to Exclude 47-Sc Production Due O039902600014 To Radioactive Decay of 47-Ca is not Described. O039902600015 ENDBIB 13 0 O039902600016 NOCOMMON 0 0 O039902600017 DATA 4 4 O039902600018 EN DATA ERR-T MONIT O039902600019 GEV MB MB MB O039902600020 1. 0.19 0.04 10.5 O039902600021 2. 0.87 0.12 9.5 O039902600022 3. 2.02 0.31 9.1 O039902600023 28.5 3.16 0.3 8.6 O039902600024 ENDDATA 6 0 O039902600025 ENDSUBENT 24 0 O039902699999 SUBENT O0399027 20020909 0000O039902700001 BIB 4 13 O039902700002 REACTION (82-PB-0(P,X)21-SC-48,,SIG) Shielded. O039902700003 RAD-DET (21-SC-48,DG) O039902700004 DECAY-DATA (21-SC-48,43.67HR,DG,984.,1., O039902700005 DG,1038.,0.98, O039902700006 DG,1314.,1.) O039902700007 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902700008 Targets at 1, 2, and 3 GeV were Made with Na-IO039902700009 Detectors and Most of the Later Measurements at 3 GeVO039902700010 And Higher were Made with Ge-Li Detectors. WheneverO039902700011 The Measurements were Repeated with Ge-Li Detectors,O039902700012 The Agreement with Earlier Result Using Na-I DetectorsO039902700013 Was Almost Always Within Experimental UncertaintiesO039902700014 +-15%, Thus Lending Confidence to All Earlier ResultsO039902700015 ENDBIB 13 0 O039902700016 NOCOMMON 0 0 O039902700017 DATA 4 4 O039902700018 EN DATA ERR-T MONIT O039902700019 GEV MB MB MB O039902700020 1. 0.14 0.025 10.5 O039902700021 2. 0.35 0.05 9.5 O039902700022 3. 0.68 0.1 9.1 O039902700023 28.5 1.3 0.13 8.6 O039902700024 ENDDATA 6 0 O039902700025 ENDSUBENT 24 0 O039902799999 SUBENT O0399028 20020909 0000O039902800001 BIB 4 4 O039902800002 REACTION (82-PB-0(P,X)21-SC-49,CUM,SIG) O039902800003 RAD-DET (21-SC-49,B-) O039902800004 DETECTOR (PROPC) O039902800005 DECAY-DATA (21-SC-49,57.5MIN,B-,2010.,1.) O039902800006 ENDBIB 4 0 O039902800007 NOCOMMON 0 0 O039902800008 DATA 4 3 O039902800009 EN DATA ERR-T MONIT O039902800010 GEV MB MB MB O039902800011 1. 0.16 0.03 10.5 O039902800012 2. 0.3 0.06 9.5 O039902800013 3. 1.27 0.25 9.1 O039902800014 ENDDATA 5 0 O039902800015 ENDSUBENT 14 0 O039902899999 SUBENT O0399029 20020909 0000O039902900001 BIB 4 11 O039902900002 REACTION (82-PB-0(P,X)23-V-47,CUM,SIG) O039902900003 RAD-DET (23-V-47,AR) O039902900004 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039902900005 Targets at 1, 2, and 3 GeV were Made with Na-IO039902900006 Detectors and Most of the Later Measurements at 3 GeVO039902900007 And Higher were Made with Ge-Li Detectors. WheneverO039902900008 The Measurements were Repeated with Ge-Li Detectors,O039902900009 The Agreement with Earlier Result Using Na-I DetectorsO039902900010 Was Almost Always Within Experimental UncertaintiesO039902900011 +-15%, Thus Lending Confidence to All Earlier ResultsO039902900012 DECAY-DATA (23-V-47,32.MIN,AR,511.,1.92) O039902900013 ENDBIB 11 0 O039902900014 NOCOMMON 0 0 O039902900015 DATA 4 4 O039902900016 EN DATA ERR-T MONIT O039902900017 GEV MB MB MB O039902900018 1. 0.039 0.01 10.5 O039902900019 2. 0.096 0.02 9.5 O039902900020 3. 0.33 0.08 9.1 O039902900021 28.5 0.43 0.04 8.6 O039902900022 ENDDATA 6 0 O039902900023 ENDSUBENT 22 0 O039902999999 SUBENT O0399030 20020909 0000O039903000001 BIB 4 11 O039903000002 REACTION (82-PB-0(P,X)23-V-48,IND,SIG) O039903000003 RAD-DET (23-V-48,DG) O039903000004 DECAY-DATA (23-V-48,16.1D,DG,984.,1.,DG,1314.,1.) O039903000005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903000006 Targets at 1, 2, and 3 GeV were Made with Na-IO039903000007 Detectors and Most of the Later Measurements at 3 GeVO039903000008 And Higher were Made with Ge-Li Detectors. WheneverO039903000009 The Measurements were Repeated with Ge-Li Detectors,O039903000010 The Agreement with Earlier Result Using Na-I DetectorsO039903000011 Was Almost Always Within Experimental UncertaintiesO039903000012 +-15%, Thus Lending Confidence to All Earlier ResultsO039903000013 ENDBIB 11 0 O039903000014 NOCOMMON 0 0 O039903000015 DATA 4 3 O039903000016 EN DATA ERR-T MONIT O039903000017 GEV MB MB MB O039903000018 2. 0.48 0.11 9.5 O039903000019 3. 0.36 0.09 9.1 O039903000020 28.5 1.99 0.19 8.6 O039903000021 ENDDATA 5 0 O039903000022 ENDSUBENT 21 0 O039903099999 SUBENT O0399031 20020909 0000O039903100001 BIB 3 3 O039903100002 REACTION (82-PB-0(P,X)24-CR-51,CUM,SIG) O039903100003 RAD-DET (24-CR-51,DG) O039903100004 DECAY-DATA (24-CR-51,27.8D,DG,320.,0.098) O039903100005 ENDBIB 3 0 O039903100006 NOCOMMON 0 0 O039903100007 DATA 4 2 O039903100008 EN DATA ERR-T MONIT O039903100009 GEV MB MB MB O039903100010 2. 0.6 0.18 9.5 O039903100011 3. 1.15 0.23 9.1 O039903100012 ENDDATA 4 0 O039903100013 ENDSUBENT 12 0 O039903199999 SUBENT O0399032 20020909 0000O039903200001 BIB 4 4 O039903200002 REACTION (92-U-0(P,X)20-CA-45,CUM,SIG) O039903200003 RAD-DET (20-CA-45,B-) O039903200004 DETECTOR (PROPC) O039903200005 DECAY-DATA (20-CA-45,164.D,B-,257.,1.) O039903200006 ENDBIB 4 0 O039903200007 NOCOMMON 0 0 O039903200008 DATA 4 4 O039903200009 EN DATA ERR-T MONIT O039903200010 GEV MB MB MB O039903200011 1. 1.42 0.2 10.5 O039903200012 2. 2.59 0.26 9.5 O039903200013 3. 3.5 0.5 9.1 O039903200014 28.5 11.21 0.7 8.6 O039903200015 ENDDATA 6 0 O039903200016 ENDSUBENT 15 0 O039903299999 SUBENT O0399033 20020909 0000O039903300001 BIB 3 3 O039903300002 REACTION (92-U-0(P,X)20-CA-47,CUM,SIG) O039903300003 RAD-DET (20-CA-47,DG) O039903300004 DECAY-DATA (20-CA-47,4.53D,DG,1297.,0.74) O039903300005 ENDBIB 3 0 O039903300006 NOCOMMON 0 0 O039903300007 DATA 4 4 O039903300008 EN DATA ERR-T MONIT O039903300009 GEV MB MB MB O039903300010 1. 0.35 0.05 10.5 O039903300011 2. 0.8 0.08 9.5 O039903300012 3. 0.94 0.1 9.1 O039903300013 28.5 2.01 0.14 8.6 O039903300014 ENDDATA 6 0 O039903300015 ENDSUBENT 14 0 O039903399999 SUBENT O0399034 20020909 0000O039903400001 BIB 4 11 O039903400002 REACTION (92-U-0(P,X)21-SC-43,CUM,SIG) O039903400003 RAD-DET (21-SC-43,AR) O039903400004 DECAY-DATA (21-SC-43,3.89HR,AR,511.,1.76) O039903400005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903400006 Targets at 1, 2, and 3 GeV were Made with Na-IO039903400007 Detectors and Most of the Later Measurements at 3 GeVO039903400008 And Higher were Made with Ge-Li Detectors. WheneverO039903400009 The Measurements were Repeated with Ge-Li Detectors,O039903400010 The Agreement with Earlier Result Using Na-I DetectorsO039903400011 Was Almost Always Within Experimental UncertaintiesO039903400012 +-15%, Thus Lending Confidence to All Earlier ResultsO039903400013 ENDBIB 11 0 O039903400014 NOCOMMON 0 0 O039903400015 DATA 4 4 O039903400016 EN DATA ERR-T MONIT O039903400017 GEV MB MB MB O039903400018 1. 0.12 0.03 10.5 O039903400019 2. 0.26 0.07 9.5 O039903400020 3. 0.51 0.13 9.1 O039903400021 28.5 0.96 0.1 8.6 O039903400022 ENDDATA 6 0 O039903400023 ENDSUBENT 22 0 O039903499999 SUBENT O0399035 20020909 0000O039903500001 BIB 4 12 O039903500002 REACTION (92-U-0(P,X)21-SC-44-G,IND,SIG) O039903500003 RAD-DET (21-SC-44-G,DG) O039903500004 (21-SC-44-G,AR) O039903500005 DECAY-DATA (21-SC-44-G,3.90HR,AR,511.,1.88,DG,1159.,1.) O039903500006 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903500007 Targets at 1, 2, and 3 GeV were Made with Na-IO039903500008 Detectors and Most of the Later Measurements at 3 GeVO039903500009 And Higher were Made with Ge-Li Detectors. WheneverO039903500010 The Measurements were Repeated with Ge-Li Detectors,O039903500011 The Agreement with Earlier Result Using Na-I DetectorsO039903500012 Was Almost Always Within Experimental UncertaintiesO039903500013 +-15%, Thus Lending Confidence to All Earlier ResultsO039903500014 ENDBIB 12 0 O039903500015 NOCOMMON 0 0 O039903500016 DATA 4 4 O039903500017 EN DATA ERR-T MONIT O039903500018 GEV MB MB MB O039903500019 1. 0.0056 0.002 10.5 O039903500020 2. 0.079 0.02 9.5 O039903500021 3. 0.21 0.07 9.1 O039903500022 28.5 0.32 0.03 8.6 O039903500023 ENDDATA 6 0 O039903500024 ENDSUBENT 23 0 O039903599999 SUBENT O0399036 20020909 0000O039903600001 BIB 4 11 O039903600002 REACTION (92-U-0(P,X)21-SC-44-M,IND,SIG) O039903600003 RAD-DET (21-SC-44-M,DG) O039903600004 DECAY-DATA (21-SC-44-M,2.44D,DG,271.,0.88) O039903600005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903600006 Targets at 1, 2, and 3 GeV were Made with Na-IO039903600007 Detectors and Most of the Later Measurements at 3 GeVO039903600008 And Higher were Made with Ge-Li Detectors. WheneverO039903600009 The Measurements were Repeated with Ge-Li Detectors,O039903600010 The Agreement with Earlier Result Using Na-I DetectorsO039903600011 Was Almost Always Within Experimental UncertaintiesO039903600012 +-15%, Thus Lending Confidence to All Earlier ResultsO039903600013 ENDBIB 11 0 O039903600014 NOCOMMON 0 0 O039903600015 DATA 4 4 O039903600016 EN DATA ERR-T MONIT O039903600017 GEV MB MB MB O039903600018 1. 0.066 0.013 10.5 O039903600019 2. 0.33 0.05 9.5 O039903600020 3. 0.56 0.1 9.1 O039903600021 28.5 1.57 0.17 8.6 O039903600022 ENDDATA 6 0 O039903600023 ENDSUBENT 22 0 O039903699999 SUBENT O0399037 20020909 0000O039903700001 BIB 4 11 O039903700002 REACTION (92-U-0(P,X)21-SC-46-G,M+,SIG) Shielded. O039903700003 RAD-DET (21-SC-46-G,DG) O039903700004 DECAY-DATA (21-SC-46-G,83.9D,DG,889.,1.,DG,1120.,1.) O039903700005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903700006 Targets at 1, 2, and 3 GeV were Made with Na-IO039903700007 Detectors and Most of the Later Measurements at 3 GeVO039903700008 And Higher were Made with Ge-Li Detectors. WheneverO039903700009 The Measurements were Repeated with Ge-Li Detectors,O039903700010 The Agreement with Earlier Result Using Na-I DetectorsO039903700011 Was Almost Always Within Experimental UncertaintiesO039903700012 +-15%, Thus Lending Confidence to All Earlier ResultsO039903700013 ENDBIB 11 0 O039903700014 NOCOMMON 0 0 O039903700015 DATA 4 4 O039903700016 EN DATA ERR-T MONIT O039903700017 GEV MB MB MB O039903700018 1. 1.17 0.16 10.5 O039903700019 2. 2.41 0.24 9.5 O039903700020 3. 4.03 0.4 9.1 O039903700021 28.5 7.7 0.34 8.6 O039903700022 ENDDATA 6 0 O039903700023 ENDSUBENT 22 0 O039903799999 SUBENT O0399038 20020909 0000O039903800001 BIB 4 13 O039903800002 REACTION (92-U-0(P,X)21-SC-47,IND,SIG) O039903800003 RAD-DET (21-SC-47,DG) O039903800004 DECAY-DATA (21-SC-47,3.4D,DG,160.,0.7) O039903800005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903800006 Targets at 1, 2, and 3 GeV were Made with Na-IO039903800007 Detectors and Most of the Later Measurements at 3 GeVO039903800008 And Higher were Made with Ge-Li Detectors. WheneverO039903800009 The Measurements were Repeated with Ge-Li Detectors,O039903800010 The Agreement with Earlier Result Using Na-I DetectorsO039903800011 Was Almost Always Within Experimental UncertaintiesO039903800012 +-15%, Thus Lending Confidence to All Earlier ResultsO039903800013 - By Compiler - Method to Exclude 47-Sc Production Due O039903800014 To Radioactive Decay of 47-Ca is not Described. O039903800015 ENDBIB 13 0 O039903800016 NOCOMMON 0 0 O039903800017 DATA 4 4 O039903800018 EN DATA ERR-T MONIT O039903800019 GEV MB MB MB O039903800020 1. 1.23 0.16 10.5 O039903800021 2. 3. 0.3 9.5 O039903800022 3. 3.57 0.35 9.1 O039903800023 28.5 5.98 0.5 8.6 O039903800024 ENDDATA 6 0 O039903800025 ENDSUBENT 24 0 O039903899999 SUBENT O0399039 20020909 0000O039903900001 BIB 4 13 O039903900002 REACTION (92-U-0(P,X)21-SC-48,,SIG) Shielded O039903900003 RAD-DET (21-SC-48,DG) O039903900004 DECAY-DATA (21-SC-48,43.67HR,DG,984.,1., O039903900005 DG,1038.,0.98, O039903900006 DG,1314.,1.) O039903900007 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039903900008 Targets at 1, 2, and 3 GeV were Made with Na-IO039903900009 Detectors and Most of the Later Measurements at 3 GeVO039903900010 And Higher were Made with Ge-Li Detectors. WheneverO039903900011 The Measurements were Repeated with Ge-Li Detectors,O039903900012 The Agreement with Earlier Result Using Na-I DetectorsO039903900013 Was Almost Always Within Experimental UncertaintiesO039903900014 +-15%, Thus Lending Confidence to All Earlier ResultsO039903900015 ENDBIB 13 0 O039903900016 NOCOMMON 0 0 O039903900017 DATA 4 4 O039903900018 EN DATA ERR-T MONIT O039903900019 GEV MB MB MB O039903900020 1. 0.88 0.13 10.5 O039903900021 2. 1.52 0.14 9.5 O039903900022 3. 1.55 0.14 9.1 O039903900023 28.5 3.1 0.21 8.6 O039903900024 ENDDATA 6 0 O039903900025 ENDSUBENT 24 0 O039903999999 SUBENT O0399040 20020909 0000O039904000001 BIB 4 4 O039904000002 REACTION (92-U-0(P,X)21-SC-49,CUM,SIG) O039904000003 RAD-DET (21-SC-49,B-) O039904000004 DETECTOR (PROPC) O039904000005 DECAY-DATA (21-SC-49,57.5MIN,B-,2010.,1.) O039904000006 ENDBIB 4 0 O039904000007 NOCOMMON 0 0 O039904000008 DATA 4 3 O039904000009 EN DATA ERR-T MONIT O039904000010 GEV MB MB MB O039904000011 1. 0.89 0.13 10.5 O039904000012 2. 1.2 0.18 9.5 O039904000013 3. 1.94 0.28 9.1 O039904000014 ENDDATA 5 0 O039904000015 ENDSUBENT 14 0 O039904099999 SUBENT O0399041 20020909 0000O039904100001 BIB 4 11 O039904100002 REACTION (92-U-0(P,X)23-V-47,CUM,SIG) O039904100003 RAD-DET (23-V-47,AR) O039904100004 DECAY-DATA (23-V-47,32.MIN,AR,511.,1.92) O039904100005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039904100006 Targets at 1, 2, and 3 GeV were Made with Na-IO039904100007 Detectors and Most of the Later Measurements at 3 GeVO039904100008 And Higher were Made with Ge-Li Detectors. WheneverO039904100009 The Measurements were Repeated with Ge-Li Detectors,O039904100010 The Agreement with Earlier Result Using Na-I DetectorsO039904100011 Was Almost Always Within Experimental UncertaintiesO039904100012 +-15%, Thus Lending Confidence to All Earlier ResultsO039904100013 ENDBIB 11 0 O039904100014 NOCOMMON 0 0 O039904100015 DATA 4 4 O039904100016 EN DATA ERR-T MONIT O039904100017 GEV MB MB MB O039904100018 1. 0.1 0.02 10.5 O039904100019 2. 0.31 0.06 9.5 O039904100020 3. 1.13 0.22 9.1 O039904100021 28.5 0.23 0.02 8.6 O039904100022 ENDDATA 6 0 O039904100023 ENDSUBENT 22 0 O039904199999 SUBENT O0399042 20020909 0000O039904200001 BIB 4 11 O039904200002 REACTION (92-U-0(P,X)23-V-48,IND,SIG) O039904200003 RAD-DET (23-V-48,DG) O039904200004 DECAY-DATA (23-V-48,16.1D,DG,984.,1.,DG,1314.,1.) O039904200005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039904200006 Targets at 1, 2, and 3 GeV were Made with Na-IO039904200007 Detectors and Most of the Later Measurements at 3 GeVO039904200008 And Higher were Made with Ge-Li Detectors. WheneverO039904200009 The Measurements were Repeated with Ge-Li Detectors,O039904200010 The Agreement with Earlier Result Using Na-I DetectorsO039904200011 Was Almost Always Within Experimental UncertaintiesO039904200012 +-15%, Thus Lending Confidence to All Earlier ResultsO039904200013 ENDBIB 11 0 O039904200014 NOCOMMON 0 0 O039904200015 DATA 4 4 O039904200016 EN DATA ERR-T MONIT O039904200017 GEV MB MB MB O039904200018 1. 0.31 0.04 10.5 O039904200019 2. 0.38 0.05 9.5 O039904200020 3. 0.49 0.07 9.1 O039904200021 28.5 2.34 0.24 8.6 O039904200022 ENDDATA 6 0 O039904200023 ENDSUBENT 22 0 O039904299999 SUBENT O0399043 20020909 0000O039904300001 BIB 4 5 O039904300002 REACTION (92-U-0(P,X)23-V-49,CUM,SIG) O039904300003 RAD-DET (23-V-49,XR) K X-Ray of Daughter Product. O039904300004 DECAY-DATA (23-V-49,300.0D,XR,4.5,0.158) O039904300005 DETECTOR (PROPC) Large Gas Proportional Counter with a Thin O039904300006 Beryllium Window. O039904300007 ENDBIB 5 0 O039904300008 NOCOMMON 0 0 O039904300009 DATA 4 3 O039904300010 EN DATA ERR-T MONIT O039904300011 GEV MB MB MB O039904300012 1. 2.08 1.03 10.5 O039904300013 2. 2.6 1.03 9.5 O039904300014 3. 4.04 1.61 9.1 O039904300015 ENDDATA 5 0 O039904300016 ENDSUBENT 15 0 O039904399999 SUBENT O0399044 20020909 0000O039904400001 BIB 4 11 O039904400002 REACTION (92-U-0(P,X)24-CR-48,CUM,SIG) O039904400003 RAD-DET (24-CR-48,DG) O039904400004 DECAY-DATA (24-CR-48,24.HR,DG,116.,0.98,DG,309.,0.99) O039904400005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039904400006 Targets at 1, 2, and 3 GeV were Made with Na-IO039904400007 Detectors and Most of the Later Measurements at 3 GeVO039904400008 And Higher were Made with Ge-Li Detectors. WheneverO039904400009 The Measurements were Repeated with Ge-Li Detectors,O039904400010 The Agreement with Earlier Result Using Na-I DetectorsO039904400011 Was Almost Always Within Experimental UncertaintiesO039904400012 +-15%, Thus Lending Confidence to All Earlier ResultsO039904400013 ENDBIB 11 0 O039904400014 NOCOMMON 0 0 O039904400015 DATA 4 3 O039904400016 EN DATA ERR-T MONIT O039904400017 GEV MB MB MB O039904400018 1. 0.00046 0.00021 10.5 O039904400019 2. 0.0046 0.0021 9.5 O039904400020 3. 0.0079 0.004 9.1 O039904400021 ENDDATA 5 0 O039904400022 ENDSUBENT 21 0 O039904499999 SUBENT O0399045 20020909 0000O039904500001 BIB 4 11 O039904500002 REACTION (92-U-0(P,X)24-CR-49,CUM,SIG) O039904500003 RAD-DET (24-CR-49,AR) O039904500004 DECAY-DATA (24-CR-49,41.9MIN,AR,511.,1.86) O039904500005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039904500006 Targets at 1, 2, and 3 GeV were Made with Na-IO039904500007 Detectors and Most of the Later Measurements at 3 GeVO039904500008 And Higher were Made with Ge-Li Detectors. WheneverO039904500009 The Measurements were Repeated with Ge-Li Detectors,O039904500010 The Agreement with Earlier Result Using Na-I DetectorsO039904500011 Was Almost Always Within Experimental UncertaintiesO039904500012 +-15%, Thus Lending Confidence to All Earlier ResultsO039904500013 ENDBIB 11 0 O039904500014 NOCOMMON 0 0 O039904500015 DATA 4 3 O039904500016 EN DATA ERR-T MONIT O039904500017 GEV MB MB MB O039904500018 1. 0.049 0.011 10.5 O039904500019 2. 0.063 0.013 9.5 O039904500020 3. 0.074 0.015 9.1 O039904500021 ENDDATA 5 0 O039904500022 ENDSUBENT 21 0 O039904599999 SUBENT O0399046 20020909 0000O039904600001 BIB 4 11 O039904600002 REACTION (92-U-0(P,X)24-CR-51,CUM,SIG) O039904600003 RAD-DET (24-CR-51,DG) O039904600004 DECAY-DATA (24-CR-51,27.8D,DG,320.,0.098) O039904600005 COMMENT - By Authors - Early G-Ray Measurements on Pb and U O039904600006 Targets at 1, 2, and 3 GeV were Made with Na-IO039904600007 Detectors and Most of the Later Measurements at 3 GeVO039904600008 And Higher were Made with Ge-Li Detectors. WheneverO039904600009 The Measurements were Repeated with Ge-Li Detectors,O039904600010 The Agreement with Earlier Result Using Na-I DetectorsO039904600011 Was Almost Always Within Experimental UncertaintiesO039904600012 +-15%, Thus Lending Confidence to All Earlier ResultsO039904600013 ENDBIB 11 0 O039904600014 NOCOMMON 0 0 O039904600015 DATA 4 3 O039904600016 EN DATA ERR-T MONIT O039904600017 GEV MB MB MB O039904600018 1. 1.11 0.22 10.5 O039904600019 2. 1.41 0.21 9.5 O039904600020 3. 2.31 0.35 9.1 O039904600021 ENDDATA 5 0 O039904600022 ENDSUBENT 21 0 O039904699999 ENDENTRY 46 0 O039999999999