ENTRY O0368 20220106 O086O036800000001 SUBENT O0368001 20220106 O086O036800100001 BIB 14 34 O036800100002 TITLE Proton total reaction cross sections at 16.4 MeV. O036800100003 AUTHOR (R.E.Pollock, G.Schrank) O036800100004 INSTITUTE (1USAPTN) O036800100005 REFERENCE (J,PR,140,B575,1965) O036800100006 SAMPLE Foil targets of a few thousandths of an inch thickness O036800100007 were selected to give energy losses between 0.6 to 1.0 O036800100008 MeV. The average thickness was determined by weighing. O036800100009 ADD-RES (COMP).Optical model analysis. O036800100010 DETECTOR (SCIN) Plastic scintillator NE102. O036800100011 FACILITY (CYCLO,1USAPTN) O036800100012 METHOD (EXTB) O036800100013 (TRN) Attenuation method O036800100014 COMMENT /By authors/.Total reaction cross sections for protons O036800100015 of a laboratory energy of 16.4 MeV at the center of O036800100016 foil targets of C, Mg, Al, Ni, Cu and Pb have been O036800100017 measured by a beam attenuation method. O036800100018 CORRECTION -By authors. The correction makes use of the fractionalO036800100019 area per unit energy at the valley position in the 'C' O036800100020 spectrum, average over many recorded. O036800100021 Correction on 'C' energy shift. O036800100022 Correction on counting rate. O036800100023 Correction on 'B' energy shift. O036800100024 Correction on target elastic scattering. O036800100025 Correction on target inelastic scattering. O036800100026 Correction on backscatter from the 'C' counter. O036800100027 ERR-ANALYS (ERR-T) Total error O036800100028 (ERR-1,1.,2.) Uncertainty in target thickness O036800100029 STATUS (TABLE) Abstract from Phys.Rev.,140(1965)B575 O036800100030 HISTORY (19970702C) O036800100031 (20040630A) Reference is corrected. Updated too O036800100032 (20071128U) Reference was changed from O036800100033 PR,B140,575,1965 to PR,140,B575,1965 as it coded in O036800100034 Phys.Rev. O036800100035 (20220106A) SD: Correction in Subent 002. O036800100036 ENDBIB 34 0 O036800100037 NOCOMMON 0 0 O036800100038 ENDSUBENT 37 0 O036800199999 SUBENT O0368002 20220106 O086O036800200001 BIB 3 3 O036800200002 REACTION (6-C-12(P,NON),,SIG) O036800200003 SAMPLE Carbon target, thickness 23.72+-0.06 mg/cm**2,was used.O036800200004 HISTORY (20220106A) SD: Data corrected according to abstract. O036800200005 ENDBIB 3 0 O036800200006 NOCOMMON 0 0 O036800200007 DATA 3 1 O036800200008 EN DATA ERR-T O036800200009 MEV MB MB O036800200010 16.48 368. 30. O036800200011 ENDDATA 3 0 O036800200012 ENDSUBENT 11 0 O036800299999 SUBENT O0368003 20040701 0000O036800300001 BIB 3 3 O036800300002 REACTION (12-MG-0(P,NON),,SIG) O036800300003 SAMPLE Magnesium target, thickness 26.9+-0.3 Md/cm**2,was usedO036800300004 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O036800300005 ENDBIB 3 0 O036800300006 NOCOMMON 0 0 O036800300007 DATA 3 1 O036800300008 EN DATA ERR-T O036800300009 MEV MB MB O036800300010 16.47 712. 56. O036800300011 ENDDATA 3 0 O036800300012 ENDSUBENT 11 0 O036800399999 SUBENT O0368004 20040701 0000O036800400001 BIB 3 3 O036800400002 REACTION (13-AL-27(P,NON),,SIG) O036800400003 SAMPLE Aluminium target,thickness 43.6+-0.26 mg/cm**2,was usedO036800400004 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O036800400005 ENDBIB 3 0 O036800400006 NOCOMMON 0 0 O036800400007 DATA 3 1 O036800400008 EN DATA ERR-T O036800400009 MEV MB MB O036800400010 16.29 701. 34. O036800400011 ENDDATA 3 0 O036800400012 ENDSUBENT 11 0 O036800499999 SUBENT O0368005 20040701 0000O036800500001 BIB 3 3 O036800500002 REACTION (28-NI-0(P,NON),,SIG) O036800500003 SAMPLE Nickel target, thickness 47.6+-0.5 mg/cm**2,was used. O036800500004 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O036800500005 ENDBIB 3 0 O036800500006 NOCOMMON 0 0 O036800500007 DATA 3 1 O036800500008 EN DATA ERR-T O036800500009 MEV MB MB O036800500010 16.33 898. 53. O036800500011 ENDDATA 3 0 O036800500012 ENDSUBENT 11 0 O036800599999 SUBENT O0368006 20040701 0000O036800600001 BIB 3 3 O036800600002 REACTION (29-CU-0(P,NON),,SIG) O036800600003 SAMPLE Copper target, thickness 42.9+-0.4 mg/cm**2,was used. O036800600004 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O036800600005 ENDBIB 3 0 O036800600006 NOCOMMON 0 0 O036800600007 DATA 3 1 O036800600008 EN DATA ERR-T O036800600009 MEV MB MB O036800600010 16.37 955. 64. O036800600011 ENDDATA 3 0 O036800600012 ENDSUBENT 11 0 O036800699999 SUBENT O0368007 20040701 0000O036800700001 BIB 3 3 O036800700002 REACTION (82-PB-0(P,NON),,SIG) O036800700003 SAMPLE Lead target, thickness 70.8+-0.7 mg/cm**2, was used. O036800700004 ERR-ANALYS (ERR-T).The uncertainty is reported by authors. O036800700005 ENDBIB 3 0 O036800700006 NOCOMMON 0 0 O036800700007 DATA 3 1 O036800700008 EN DATA ERR-T O036800700009 MEV MB MB O036800700010 16.31 1330. 180. O036800700011 ENDDATA 3 0 O036800700012 ENDSUBENT 11 0 O036800799999 ENDENTRY 7 0 O036899999999