ENTRY O0221 19970116 0000O022100000001 SUBENT O0221001 19970116 0000O022100100001 BIB 10 17 O022100100002 TITLE Cross Sections For Binary and Ternary Fission Induced O022100100003 By High-Energy Protons in Uranium and Lead. O022100100004 AUTHOR (G.REMY,J.RALAROSY,R.STEIN,M.DEBEAUVAIS,J.TRIPIER) O022100100005 INSTITUTE (2FR STR) O022100100006 REFERENCE (J,NP/A,163,583,71) O022100100007 HISTORY (960604C) O022100100008 (970116U) Last checking has been done. O022100100009 DETECTOR (TRD).A Solid State Plastic Detector (MAKROFOL). O022100100010 FACILITY (SYNCY,2ZZZCER) 0.59, 18. And 23. GeV O022100100011 (SYNCY,2FR SAC) 2. And 3. GeV. O022100100012 METHOD (ACTIV,EXTB,CHSEP,BCINT) O022100100013 SAMPLE The Thickness of a Target Layer was Determined by O022100100014 Weighing and Also by an Optical Method.This Procedure O022100100015 Leads to an Error of the Estimated Number of Target O022100100016 Nuclei Lying Between 5 and 10%.Only Spectroscopically O022100100017 Pure Target Materials have Been Used. O022100100018 STATUS (TABLE) O022100100019 ENDBIB 17 0 O022100100020 NOCOMMON 0 0 O022100100021 ENDSUBENT 20 0 O022100199999 SUBENT O0221002 19970116 0000O022100200001 BIB 2 6 O022100200002 REACTION (92-U-0(P,F),BIN,SIG,,,EXP) O022100200003 ERR-ANALYS The Errors Presented by Authors are Due to Statistical O022100200004 And Counting Errors,Uncertainties in the Thicknesses O022100200005 Of the Target Layers (5 TO 10%) And the Errors in the O022100200006 Integrated Proton Fluxes (ABOUT 10%). O022100200007 (ERR-T).The Uncertainty is Reported by Authors. O022100200008 ENDBIB 6 0 O022100200009 NOCOMMON 0 0 O022100200010 DATA 3 5 O022100200011 EN DATA ERR-T O022100200012 GEV MB MB O022100200013 0.6 1204. 133. O022100200014 2.0 1337. 130. O022100200015 3.0 1321. 100. O022100200016 18. 832. 120. O022100200017 23. 779. 125. O022100200018 ENDDATA 7 0 O022100200019 ENDSUBENT 18 0 O022100299999 SUBENT O0221003 19970116 0000O022100300001 BIB 2 6 O022100300002 REACTION (82-PB-0(P,F),BIN,SIG,,,EXP) O022100300003 ERR-ANALYS The Errors Presented by Authors are Due to Statistical O022100300004 And Counting Errors,Uncertainties in the Thicknesses O022100300005 Of the Target Layers (5 TO 10%) And the Errors in the O022100300006 Integrated Proton Fluxes (ABOUT 10%). O022100300007 (ERR-T).The Uncertainty is Reported by Authors. O022100300008 ENDBIB 6 0 O022100300009 NOCOMMON 0 0 O022100300010 DATA 3 5 O022100300011 EN DATA ERR-T O022100300012 GEV MB MB O022100300013 0.6 134. 18. O022100300014 2.0 139. 20. O022100300015 3.0 135. 26. O022100300016 18. 117. 16. O022100300017 23. 107. 14. O022100300018 ENDDATA 7 0 O022100300019 ENDSUBENT 18 0 O022100399999 SUBENT O0221004 19970116 0000O022100400001 BIB 3 14 O022100400002 REACTION (92-U-0(P,F),TER,SIG,,,EXP) O022100400003 ERR-ANALYS The Loss of Ternary Events Due to the Etching Effect O022100400004 Has Been Estimated on the Assumptions That Ternary O022100400005 Events are Coplanar,the Distribution of the Normal to O022100400006 That Plane is Isotopic and the Mean Range of Fragments O022100400007 Is the Same As of Those Coming from the Binary Events, O022100400008 I.E. About 15 Mum.In this Case the Correction Turns O022100400009 Out to be 6%.Since the Correction For Loss is O022100400010 Approximately the Sama As That For Accidental O022100400011 Coincidence,Respectively 6% and 5%,the Data is ReportedO022100400012 By Authors have not Been Corrected at All.This Leads O022100400013 To a Systematic Error of About 1%. O022100400014 (ERR-T).The Uncertainty is Reported by Authors. O022100400015 FLAG (1.).Indicates Poor Statistics at these Energies. O022100400016 ENDBIB 14 0 O022100400017 NOCOMMON 0 0 O022100400018 DATA 4 5 O022100400019 EN DATA ERR-T FLAG O022100400020 GEV MB MB NO-DIM O022100400021 0.6 0.6 1. O022100400022 2.0 6.3 1. O022100400023 3.0 10.6 2.5 O022100400024 18. 16.6 4.5 O022100400025 23. 13.2 3.0 O022100400026 ENDDATA 7 0 O022100400027 ENDSUBENT 26 0 O022100499999 SUBENT O0221005 19970116 0000O022100500001 BIB 3 14 O022100500002 REACTION (82-PB-0(P,F),TER,SIG,,,EXP) O022100500003 ERR-ANALYS The Loss of Ternary Events Due to the Etching Effect O022100500004 Has Been Estimated on the Assumptions That Ternary O022100500005 Events are Coplanar,the Distribution of the Normal to O022100500006 That Plane is Isotopic and the Mean Range of Fragments O022100500007 Is the Same As of Those Coming from the Binary Events, O022100500008 I.E. About 15 Mum.In this Case the Correction Turns O022100500009 Out to be 6%.Since the Correction For Loss is O022100500010 Approximately the Sama As That For Accidental O022100500011 Coincidence,Respectively 6% and 5%,the Data is ReportedO022100500012 By Authors have not Been Corrected at All.This Leads O022100500013 To a Systematic Error of About 1%. O022100500014 (ERR-T).The Uncertainty is Reported by Authors. O022100500015 FLAG (1.).Indicates Poor Statistics at these Energies. O022100500016 ENDBIB 14 0 O022100500017 NOCOMMON 0 0 O022100500018 DATA 4 5 O022100500019 EN DATA ERR-T FLAG O022100500020 GEV MB MB NO-DIM O022100500021 0.6 0.2 1. O022100500022 2.0 1.1 1. O022100500023 3.0 2.4 0.6 O022100500024 18. 4.2 0.8 O022100500025 23. 3.2 0.6 O022100500026 ENDDATA 7 0 O022100500027 ENDSUBENT 26 0 O022100599999 ENDENTRY 5 0 O022199999999