ENTRY O0213 19970624 0000O021300000001 SUBENT O0213001 19970624 0000O021300100001 BIB 11 33 O021300100002 TITLE Reaction Cross Sections For Protons in the Energy O021300100003 Range 220-570 MeV. O021300100004 AUTHOR (P.U.RENBERG,D.F.MEASDAY,M.PEPIN,P.SCHWALLER,B.FAVIER, O021300100005 C.RICHARD-SERRE) O021300100006 INSTITUTE (2ZZZCER) O021300100007 (2SWTZUR).Swiss Institute of Nuclear Research,Zurich. O021300100008 (2FR GRE). Grenoble University. O021300100009 REFERENCE (J,NP/A,183,81,72) O021300100010 HISTORY (960523C) O021300100011 (961208A). Correction of Cross Sections For Compounds. O021300100012 (970624A). Correction of Reaction Lines and Misc-Col. O021300100013 (970624U) Last checking has been done. O021300100014 ADD-RES (COMP).The Semi-Classical Theory. O021300100015 DETECTOR (SCIN).Circular Scintillators,Each 3 mm Thick with O021300100016 A Diameter of 3 Cm. The Transmission Counters ConsistedO021300100017 Of Four Closely Spaced Circular Counters with GraduallyO021300100018 Increasing Diameters,Each 5 mm Thick. Close to the LastO021300100019 Counter a 50*50 Cm**2 Copper Plate of Variable O021300100020 Thickness was Mounted,Followed by a Fifth Counter,45 CmO021300100021 In Diameter. At the Rear of the Telescope was Placed anO021300100022 Efficiency Counter,3 mm Thick and 6 Cm in Diameter. AllO021300100023 Counters were Viewed by 56 Avp Photomultipliers. The O021300100024 Telescope Assembly was Mounted on a Trolley Movable on O021300100025 A Rail in the Beam Direction Thus Allowing a Variation O021300100026 Of the Range of Solid Angles. O021300100027 FACILITY (SYNCY,2ZZZCER).The Cern 600 MeV Synchrocyclotron. O021300100028 METHOD (EXTB,INTB) O021300100029 SAMPLE All Targets had Dimensions in the Plane Perpendicular O021300100030 To the Beam Such That All Particles Passing Through O021300100031 The Beam Defining Counters Traversed the Full Target O021300100032 Lengths Even If They were Elastically Scattered Off a O021300100033 Target Nucleus. O021300100034 ERR-ANALYS (ERR-T).The Uncertainty is Reported by Authors. O021300100035 ENDBIB 33 0 O021300100036 NOCOMMON 0 0 O021300100037 ENDSUBENT 36 0 O021300199999 SUBENT O0213002 19970624 0000O021300200001 BIB 3 4 O021300200002 REACTION (4-BE-9(P,NON),,SIG,,,EXP) O021300200003 SAMPLE Natural Beryllium Target,Thickness 5.01 Cm,was Used. O021300200004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300200005 Detector For Energy Separation. O021300200006 ENDBIB 4 0 O021300200007 NOCOMMON 0 0 O021300200008 DATA 4 8 O021300200009 EN DATA ERR-T MISC O021300200010 MEV MB MB G/CM-SQ O021300200011 553. 190.1 6.2 0. O021300200012 553. 195.4 6.2 44.5 O021300200013 464. 189.3 6.2 0. O021300200014 464. 195.1 6.3 35.6 O021300200015 346. 185.9 6.3 0. O021300200016 346. 188.1 6.4 22.3 O021300200017 232. 190.6 6.8 0. O021300200018 232. 189.4 6.9 13.4 O021300200019 ENDDATA 10 0 O021300200020 ENDSUBENT 19 0 O021300299999 SUBENT O0213003 19970624 0000O021300300001 BIB 3 4 O021300300002 REACTION (6-C-12(P,NON),,SIG,,,EXP) O021300300003 SAMPLE Natural Carbon Target,Thickness 5.00 Cm,was Used. O021300300004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300300005 Detector For Energy Separation. O021300300006 ENDBIB 4 0 O021300300007 NOCOMMON 0 0 O021300300008 DATA 4 8 O021300300009 EN DATA ERR-T MISC O021300300010 MEV MB MB G/CM-SQ O021300300011 552. 229.2 5.4 0. O021300300012 552. 232.8 5. 44.5 O021300300013 464. 228.5 5.1 0. O021300300014 464. 231.7 5.1 35.6 O021300300015 345. 218.8 5.1 0. O021300300016 345. 219.5 5.3 22.3 O021300300017 231. 215.2 5.4 0. O021300300018 231. 218. 5.4 13.4 O021300300019 ENDDATA 10 0 O021300300020 ENDSUBENT 19 0 O021300399999 SUBENT O0213004 19970624 0000O021300400001 BIB 3 4 O021300400002 REACTION (13-AL-27(P,NON),,SIG,,,EXP) O021300400003 SAMPLE Natural Aluminium Target,Thickness 3.00 Cm,was Used. O021300400004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300400005 Detector For Energy Separation. O021300400006 ENDBIB 4 0 O021300400007 NOCOMMON 0 0 O021300400008 DATA 4 8 O021300400009 EN DATA ERR-T MISC O021300400010 MEV MB MB G/CM-SQ O021300400011 554. 424.8 8. 0. O021300400012 554. 433.2 7.7 44.5 O021300400013 466. 421.4 8.2 0. O021300400014 466. 423.9 7.4 35.6 O021300400015 348. 401.8 7. 0. O021300400016 348. 402.1 7. 22.3 O021300400017 234. 400.8 7.1 0. O021300400018 234. 399.6 7.4 13.4 O021300400019 ENDDATA 10 0 O021300400020 ENDSUBENT 19 0 O021300499999 SUBENT O0213005 19970624 0000O021300500001 BIB 3 4 O021300500002 REACTION (26-FE-0(P,NON),,SIG,,,EXP) O021300500003 SAMPLE Natural Iron Target,Thickness 1.50 Cm,was Used. O021300500004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300500005 Detector For Energy Separation. O021300500006 ENDBIB 4 0 O021300500007 NOCOMMON 0 0 O021300500008 DATA 4 8 O021300500009 EN DATA ERR-T MISC O021300500010 MEV MB MB G/CM-SQ O021300500011 552. 702. 12. 0. O021300500012 552. 712. 13. 44.5 O021300500013 463. 701. 13. 0. O021300500014 463. 711. 14. 35.6 O021300500015 345. 678. 11. 0. O021300500016 345. 679. 12. 22.3 O021300500017 230. 683. 12. 0. O021300500018 230. 685. 13. 13.4 O021300500019 ENDDATA 10 0 O021300500020 ENDSUBENT 19 0 O021300599999 SUBENT O0213006 19970624 0000O021300600001 BIB 3 4 O021300600002 REACTION (29-CU-0(P,NON),,SIG,,,EXP) O021300600003 SAMPLE Natural Copper Target,Thickness 2.00 Cm,was Used. O021300600004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300600005 Detector For Energy Separation. O021300600006 ENDBIB 4 0 O021300600007 NOCOMMON 0 0 O021300600008 DATA 4 8 O021300600009 EN DATA ERR-T MISC O021300600010 MEV MB MB G/CM-SQ O021300600011 548. 777. 17. 0. O021300600012 548. 788. 17. 44.5 O021300600013 459. 775. 17. 0. O021300600014 459. 787. 17. 35.6 O021300600015 340. 751. 17. 0. O021300600016 340. 760. 17. 22.3 O021300600017 225. 761. 17. 0. O021300600018 225. 768. 17. 13.4 O021300600019 ENDDATA 10 0 O021300600020 ENDSUBENT 19 0 O021300699999 SUBENT O0213007 19970624 0000O021300700001 BIB 3 4 O021300700002 REACTION (32-GE-0(P,NON),,SIG,,,EXP) O021300700003 SAMPLE Natural Gellium Target,Thickness 1.50 Cm,was Used. O021300700004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300700005 Detector For Energy Separation. O021300700006 ENDBIB 4 0 O021300700007 NOCOMMON 0 0 O021300700008 DATA 4 10 O021300700009 EN DATA ERR-T MISC O021300700010 MEV MB MB G/CM-SQ O021300700011 568. 876. 17. 0. O021300700012 568. 877. 18. 44.5 O021300700013 498. 880. 17. 0. O021300700014 498. 887. 17. 44.5 O021300700015 412. 858. 16. 0. O021300700016 412. 867. 17. 26.7 O021300700017 347. 850. 17. 0. O021300700018 347. 857. 20. 26.7 O021300700019 237. 844. 16. 0. O021300700020 237. 854. 16. 8.9 O021300700021 ENDDATA 12 0 O021300700022 ENDSUBENT 21 0 O021300799999 SUBENT O0213008 19970624 0000O021300800001 BIB 3 5 O021300800002 REACTION (11-NA-CMP(P,NON),,SIG,,,EXP) O021300800003 SAMPLE The Cylindrical Nai Target,Thickness 2.58 Cm,was O021300800004 Covered on the Flat Sides by 50 Mum Aluminium Foils. O021300800005 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300800006 Detector For Energy Separation. O021300800007 ENDBIB 5 0 O021300800008 NOCOMMON 0 0 O021300800009 DATA 4 10 O021300800010 EN DATA ERR-T MISC O021300800011 MEV MB MB G/CM-SQ O021300800012 567. 1678. 41. 0. O021300800013 567. 1704. 43. 44.5 O021300800014 497. 1685. 37. 0. O021300800015 497. 1701. 38. 44.5 O021300800016 412. 1626. 37. 0. O021300800017 412. 1638. 38. 26.7 O021300800018 346. 1612. 37. 0. O021300800019 346. 1646. 38. 26.7 O021300800020 236. 1619. 38. 0. O021300800021 236. 1636. 42. 8.9 O021300800022 ENDDATA 12 0 O021300800023 ENDSUBENT 22 0 O021300899999 SUBENT O0213009 19970624 0000O021300900001 BIB 3 4 O021300900002 REACTION (50-SN-0(P,NON),,SIG,,,EXP) O021300900003 SAMPLE Natural Tin Target,Thickness 3.00 Cm,was Used. O021300900004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021300900005 Detector For Energy Separation. O021300900006 ENDBIB 4 0 O021300900007 NOCOMMON 0 0 O021300900008 DATA 4 8 O021300900009 EN DATA ERR-T MISC O021300900010 MEV MB MB G/CM-SQ O021300900011 546. 1175. 23. 0. O021300900012 546. 1201. 23. 44.5 O021300900013 456. 1186. 22. 0. O021300900014 456. 1191. 22. 35.6 O021300900015 337. 1152. 22. 0. O021300900016 337. 1161. 23. 22.3 O021300900017 221. 1173. 23. 0. O021300900018 221. 1187. 23. 13.4 O021300900019 ENDDATA 10 0 O021300900020 ENDSUBENT 19 0 O021300999999 SUBENT O0213010 19970624 0000O021301000001 BIB 3 4 O021301000002 REACTION (82-PB-0(P,NON),,SIG,,,EXP) O021301000003 SAMPLE Natural Lead Target,Thickness 1.80 Cm,was Used. O021301000004 MISC-COL (MISC).The Amounts of Cu Absorber (G/CM**2) Used in theO021301000005 Detector For Energy Separation. O021301000006 ENDBIB 4 0 O021301000007 NOCOMMON 0 0 O021301000008 DATA 4 8 O021301000009 EN DATA ERR-T MISC O021301000010 MEV MB MB G/CM-SQ O021301000011 549. 1732. 48. 0. O021301000012 549. 1781. 46. 44.5 O021301000013 460. 1770. 47. 0. O021301000014 460. 1789. 46. 35.6 O021301000015 341. 1703. 47. 0. O021301000016 341. 1719. 47. 22.3 O021301000017 226. 1737. 47. 0. O021301000018 226. 1767. 48. 13.4 O021301000019 ENDDATA 10 0 O021301000020 ENDSUBENT 19 0 O021301099999 SUBENT O0213011 19970624 0000O021301100001 BIB 2 4 O021301100002 REACTION 1(1-H-PLE(P,NON),,SIG,,,EXP) O021301100003 2(6-C-0(P,NON),,SIG,,,CALC) From Polyethylene Target. O021301100004 3(1-H-1(P,NON),,SIG,,,CALC) O021301100005 SAMPLE Ch(2) Target,Thickness 4.95 Cm,was Used. O021301100006 ENDBIB 4 0 O021301100007 COMMON 3 3 O021301100008 ERR-T 1ERR-T 2ERR-T 3 O021301100009 MB MB MB O021301100010 7. 5. 4. O021301100011 ENDCOMMON 3 0 O021301100012 DATA 4 4 O021301100013 EN DATA 1DATA 2DATA 3 O021301100014 MEV MB MB MB O021301100015 552. 247. 233. 7. O021301100016 464. 240. 232. 4. O021301100017 343. 222. 220. 1. O021301100018 231. 216. 218. -1. O021301100019 ENDDATA 6 0 O021301100020 ENDSUBENT 19 0 O021301199999 SUBENT O0213012 19970624 0000O021301200001 BIB 2 4 O021301200002 REACTION 1(5-B-CMP(P,NON),,SIG,,,EXP) O021301200003 C(6-C-0(P,NON),,SIG,,,CALC) O021301200004 B(5-B-0(P,NON),,SIG,,,CALC) O021301200005 SAMPLE B(4)C Target,Thickness 3.04 Cm,was Used. O021301200006 ENDBIB 4 0 O021301200007 COMMON 1 3 O021301200008 ERR-T C O021301200009 MB O021301200010 5. O021301200011 ENDCOMMON 3 0 O021301200012 DATA 6 5 O021301200013 EN DATA 1ERR-T 1DATA CDATA BERR-T BO021301200014 MEV MB MB MB MB MB O021301200015 565. 1087. 25. 234. 213. 6.O021301200016 497. 1070. 24. 231. 210. 6.O021301200017 410. 1050. 24. 227. 206. 6.O021301200018 345. 1017. 27. 224. 198. 7.O021301200019 235. 1006. 28. 219. 197. 7.O021301200020 ENDDATA 7 0 O021301200021 ENDSUBENT 20 0 O021301299999 SUBENT O0213013 19970624 0000O021301300001 BIB 2 6 O021301300002 REACTION 1(1-H-WTR(P,NON),,SIG,,,EXP) O021301300003 H(1-H-1(P,NON),,SIG,,,CALC) O021301300004 O(8-O-0(P,NON),,SIG,,,CALC) O021301300005 SAMPLE H(2)O Target Consisted of Distilled Water in an O021301300006 Aluminium Cylinder with Two 200 Mum Thick Polyethylene O021301300007 Windows. O021301300008 ENDBIB 6 0 O021301300009 COMMON 1 3 O021301300010 ERR-T H O021301300011 MB O021301300012 4. O021301300013 ENDCOMMON 3 0 O021301300014 DATA 6 4 O021301300015 EN DATA 1ERR-T 1DATA HDATA OERR-T OO021301300016 MEV MB MB MB MB MB O021301300017 552. 304. 13. 7. 290. 15.O021301300018 464. 296. 13. 4. 288. 15.O021301300019 345. 284. 12. 1. 282. 14.O021301300020 231. 295. 12. 295. 12.O021301300021 ENDDATA 6 0 O021301300022 ENDSUBENT 21 0 O021301399999 SUBENT O0213014 19970624 0000O021301400001 BIB 2 4 O021301400002 REACTION 1(11-NA-CMP(P,NON),,SIG,,,EXP) O021301400003 N(11-NA-23(P,NON),,SIG,,,CALC) O021301400004 I(53-I-127(P,NON),,SIG,,,CALC) O021301400005 SAMPLE Na-I Thickness is 2.58 Cm. O021301400006 ENDBIB 4 0 O021301400007 COMMON 1 3 O021301400008 ERR-T N O021301400009 MB O021301400010 10. O021301400011 ENDCOMMON 3 0 O021301400012 DATA 6 5 O021301400013 EN DATA 1ERR-T 1DATA NDATA IERR-T IO021301400014 MEV MB MB MB MB MB O021301400015 567. 1704. 43. 379. 1325. 44.O021301400016 497. 1701. 38. 376. 1325. 39.O021301400017 412. 1638. 38. 366. 1272. 39.O021301400018 346. 1646. 38. 359. 1287. 39.O021301400019 236. 1636. 42. 357. 1279. 43.O021301400020 ENDDATA 7 0 O021301400021 ENDSUBENT 20 0 O021301499999 ENDENTRY 14 0 O021399999999