ENTRY O0145 19950629 0000O014500000001 SUBENT O0145001 19950629 0000O014500100001 BIB 13 23 O014500100002 TITLE BACKWARD EMISSION OF ENERGETIC PROTONS. O014500100003 AUTHOR (M.AVAN,A.BALDIT,J.CASTOR,G.CHAIGNE,A.DEVAUX, O014500100004 J.FARGEIX,P.FORCE,G.LANDAUD,G.ROCHE,J.VICENTE, O014500100005 J.P.DIDELEZ,F.REIDE,S.A.GURVITZ) O014500100006 INSTITUTE (2FR CLE) O014500100007 (2FR PAR) O014500100008 (3ISLWZI) O014500100009 REFERENCE (J,PR/C,30,521,84) O014500100010 HISTORY (950629C) O014500100011 (950919U). LAST CHECKING HAS BEEN DONE. O014500100012 SAMPLE VARIOUS TARGETS (LI-6,AL-27,NI-58 AND AU-197) WERE O014500100013 USED AS REPRESENTATIVES OF LIGHT, MEDIUM AND HEAVY O014500100014 NUCLEI. O014500100015 FACILITY (SYNCY,2FR PAR) O014500100016 METHOD (BCINT,TOF) O014500100017 PART-DET (P) O014500100018 DETECTOR (MWPC).TWO MULTIWIRE PROPORTIONAL COUNTERS WAS USED. O014500100019 ADD-RES (COMP).THE QUASI-TWO-BODY-SCALING APPROACH. O014500100020 STATUS (CURVE).BY CAJAD. O014500100021 ERR-ANALYS THE UNCERTAINTY IN ABSOLUTE NORMALIZATION DUE TO TARGETO014500100022 THICKNESS,BEAM MONITORING AND EFFICIENCY OF THE SYSTEM O014500100023 AS A FUNCTION OF PROTON ENERGY (BY FAR THE LARGEST O014500100024 CONTRIBUTION) IS ESTIMATED TO BE LOWER THAN 5%. O014500100025 ENDBIB 23 0 O014500100026 COMMON 1 3 O014500100027 EN O014500100028 MEV O014500100029 200. O014500100030 ENDCOMMON 3 0 O014500100031 ENDSUBENT 30 0 O014500199999 SUBENT O0145002 19950629 0000O014500200001 BIB 3 7 O014500200002 REACTION (3-LI-6(P,X)1-H-1,,DA/DE,,,EXP) O014500200003 EN-SEC (E,P) O014500200004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500200005 (ERR-S).THE UNCERTAINTY IS REPORTED BY AUTHORS. ERROR O014500200006 BARS, PURELY STATISTICAL, ARE SHOWN WHEN LARGER THAN O014500200007 THE POINT. O014500200008 (E-ERR).DATA-POINT READER UNCERTAINTY. O014500200009 ENDBIB 7 0 O014500200010 COMMON 3 3 O014500200011 ANG E-ERR DATA-ERR O014500200012 ADEG MEV PER-CENT O014500200013 102. 0.4 2.8 O014500200014 ENDCOMMON 3 0 O014500200015 DATA 3 26 O014500200016 E DATA ERR-S O014500200017 MEV MUB/SR/MEV PER-CENT O014500200018 81.4 0.885 O014500200019 82.4 0.726 O014500200020 85.1 0.684 O014500200021 87.8 0.595 O014500200022 89.4 0.488 O014500200023 92. 0.488 O014500200024 93.1 0.451 O014500200025 95. 0.377 O014500200026 97.4 0.329 O014500200027 98.5 0.329 O014500200028 101.1 0.329 O014500200029 103. 0.303 O014500200030 106.5 0.269 O014500200031 106.8 0.221 O014500200032 109.1 0.181 O014500200033 110.7 0.149 O014500200034 113.4 0.122 O014500200035 115.8 0.924 E-01 O014500200036 117.1 0.773 E-01 O014500200037 119.8 0.552 E-01 O014500200038 121.4 0.552 E-01 O014500200039 122.5 0.418 E-01 9. O014500200040 124.1 0.452 E-01 5. O014500200041 127.8 0.418 E-01 10. O014500200042 129.4 0.281 E-01 10. O014500200043 130.5 0.138 E-01 19. O014500200044 ENDDATA 28 0 O014500200045 ENDSUBENT 44 0 O014500299999 SUBENT O0145003 19950629 0000O014500300001 BIB 3 7 O014500300002 REACTION (13-AL-27(P,X)1-H-1,,DA/DE,,,EXP) O014500300003 EN-SEC (E,P) O014500300004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500300005 (ERR-S).THE UNCERTAINTY IS REPORTED BY AUTHORS. ERROR O014500300006 BARS, PURELY STATISTICAL, ARE SHOWN WHEN LARGER THAN O014500300007 THE POINT. O014500300008 (E-ERR).DATA-POINT READER UNCERTAINTY. O014500300009 ENDBIB 7 0 O014500300010 COMMON 3 3 O014500300011 ANG E-ERR DATA-ERR O014500300012 ADEG MEV PER-CENT O014500300013 102. 0.4 2.8 O014500300014 ENDCOMMON 3 0 O014500300015 DATA 3 47 O014500300016 E DATA ERR-S O014500300017 MEV MUB/SR/MEV PER-CENT O014500300018 89.4 14.2 O014500300019 92.9 11.7 O014500300020 93.1 10.8 O014500300021 95.8 9.56 O014500300022 97.4 8.83 O014500300023 98.5 7.84 O014500300024 101.1 7.24 O014500300025 103.8 6.43 O014500300026 105.7 5.82 O014500300027 106.5 5.27 O014500300028 109.1 4.77 O014500300029 111.8 4.32 O014500300030 113.7 3.55 O014500300031 114.5 3.24 O014500300032 118.7 2.91 O014500300033 119.8 2.39 O014500300034 121.4 2.2 O014500300035 122.5 1.81 O014500300036 125.2 1.6 O014500300037 127.8 1.32 O014500300038 130.5 1.22 O014500300039 132.1 1.08 O014500300040 133.2 0.978 O014500300041 135.8 0.818 O014500300042 137.4 0.671 O014500300043 140.1 0.595 O014500300044 141.2 0.488 O014500300045 143.8 0.37 O014500300046 146.5 0.329 O014500300047 146.7 0.269 O014500300048 149.2 0.221 O014500300049 150.8 0.181 O014500300050 153.5 0.137 O014500300051 155.9 0.113 O014500300052 157.2 0.82 E-01 O014500300053 159.1 0.621 E-01 O014500300054 161.5 0.51 E-01 O014500300055 162.5 0.371 E-01 O014500300056 165.2 0.281 E-01 O014500300057 166.8 0.205 E-01 O014500300058 167.9 0.155 E-01 O014500300059 170.5 0.1043E-01 O014500300060 173.2 0.76 E-02 11. O014500300061 175.9 0.511 E-02 10. O014500300062 177.5 0.231 E-02 11. O014500300063 180.2 0.218 E-02 26. O014500300064 181.2 0.156 E-02 30. O014500300065 ENDDATA 49 0 O014500300066 ENDSUBENT 65 0 O014500399999 SUBENT O0145004 19950629 0000O014500400001 BIB 3 7 O014500400002 REACTION (28-NI-58(P,X)1-H-1,,DA/DE,,,EXP) O014500400003 EN-SEC (E,P) O014500400004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500400005 (ERR-S).THE UNCERTAINTY IS REPORTED BY AUTHORS. ERROR O014500400006 BARS, PURELY STATISTICAL, ARE SHOWN WHEN LARGER THAN O014500400007 THE POINT. O014500400008 (E-ERR).DATA-POINT READER UNCERTAINTY. O014500400009 ENDBIB 7 0 O014500400010 COMMON 3 3 O014500400011 ANG E-ERR DATA-ERR O014500400012 ADEG MEV PER-CENT O014500400013 102. 0.4 2.8 O014500400014 ENDCOMMON 3 0 O014500400015 DATA 3 33 O014500400016 E DATA ERR-S O014500400017 MEV MUB/SR/MEV PER-CENT O014500400018 118.5 5.27 O014500400019 119.8 4.87 O014500400020 121.4 4.32 O014500400021 122.5 3.99 O014500400022 125.2 3.55 O014500400023 127.8 3.21 O014500400024 129.7 2.69 O014500400025 132.1 2.39 O014500400026 133.2 1.96 O014500400027 135.8 1.6 O014500400028 137.4 1.48 O014500400029 139.8 1.22 O014500400030 141.2 0.997 O014500400031 143.8 0.885 O014500400032 146.5 0.671 O014500400033 147.8 0.595 O014500400034 149.2 0.488 O014500400035 150.8 0.401 O014500400036 154.5 0.329 O014500400037 156.1 0.269 O014500400038 157.2 0.204 O014500400039 159.1 0.149 O014500400040 161.5 0.122 O014500400041 162.5 0.82 E-01 O014500400042 165.2 0.673 E-01 O014500400043 167.1 0.452 E-01 O014500400044 169.5 0.371 E-01 O014500400045 170.5 0.304 E-01 O014500400046 173.2 0.205 E-01 11. O014500400047 175.9 0.13 E-01 9. O014500400048 177.5 0.1043E-01 20. O014500400049 180.2 0.623 E-02 21. O014500400050 181.2 0.282 E-02 25. O014500400051 ENDDATA 35 0 O014500400052 ENDSUBENT 51 0 O014500499999 SUBENT O0145005 19950629 0000O014500500001 BIB 3 7 O014500500002 REACTION (79-AU-197(P,X)1-H-1,,DA/DE,,,EXP) O014500500003 EN-SEC (E,P) O014500500004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500500005 (ERR-S).THE UNCERTAINTY IS REPORTED BY AUTHORS. ERROR O014500500006 BARS, PURELY STATISTICAL, ARE SHOWN WHEN LARGER THAN O014500500007 THE POINT. O014500500008 (E-ERR).DATA-POINT READER UNCERTAINTY. O014500500009 ENDBIB 7 0 O014500500010 COMMON 3 3 O014500500011 ANG E-ERR DATA-ERR O014500500012 ADEG MEV PER-CENT O014500500013 102. 0.4 2.8 O014500500014 ENDCOMMON 3 0 O014500500015 DATA 3 53 O014500500016 E DATA ERR-S O014500500017 MEV MUB/SR/MEV PER-CENT O014500500018 81.4 95.3 O014500500019 82.4 95.3 O014500500020 85.1 84.6 O014500500021 87.8 78.1 O014500500022 89.4 69.4 O014500500023 93.1 69.4 O014500500024 93.4 64.1 O014500500025 95. 56.9 O014500500026 97.4 52.6 O014500500027 98.5 46.7 O014500500028 101.1 43.1 O014500500029 102.7 38.3 O014500500030 105.4 35.4 O014500500031 106.5 31.4 O014500500032 109.1 25.7 O014500500033 111. 25.7 O014500500034 113.4 23.8 O014500500035 114.5 21.1 O014500500036 117.1 19.5 O014500500037 119.8 16. O014500500038 121.4 14.2 O014500500039 122.5 14.2 O014500500040 125.2 11.7 O014500500041 127.8 9.56 O014500500042 129.7 9. O014500500043 130.5 7.84 O014500500044 133.2 6.43 O014500500045 135. 5.94 O014500500046 137.4 5.27 O014500500047 138.5 4.32 O014500500048 141.2 3.99 O014500500049 143. 3.34 O014500500050 145.7 2.74 O014500500051 146.5 2.39 O014500500052 149.2 1.96 O014500500053 150.8 1.6 O014500500054 153.5 1.24 O014500500055 154.5 1.08 O014500500056 157.2 0.885 O014500500057 158.8 0.684 O014500500058 161.5 0.55 O014500500059 162.5 0.488 O014500500060 164.4 0.329 O014500500061 166.8 0.269 O014500500062 167.9 0.204 O014500500063 170.5 0.14 O014500500064 173.2 0.942 E-01 O014500500065 174.8 0.82 E-01 O014500500066 177.2 0.621 E-01 13. O014500500067 178.6 0.371 E-01 11. O014500500068 181.2 0.371 E-01 8. O014500500069 183.9 0.193 E-01 21. O014500500070 185.2 0.76 E-02 28. O014500500071 ENDDATA 55 0 O014500500072 ENDSUBENT 71 0 O014500599999 SUBENT O0145006 19950629 0000O014500600001 BIB 3 7 O014500600002 REACTION (13-AL-27(P,X)1-H-1,,DA/DE,,,EXP) O014500600003 EN-SEC (E,P) O014500600004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500600005 (ERR-S).THE UNCERTAINTY IS REPORTED BY AUTHORS. ERROR O014500600006 BARS, PURELY STATISTICAL, ARE SHOWN WHEN LARGER THAN O014500600007 THE POINT. O014500600008 (E-ERR).DATA-POINT READER UNCERTAINTY. O014500600009 ENDBIB 7 0 O014500600010 COMMON 3 3 O014500600011 ANG E-ERR DATA-ERR O014500600012 ADEG MEV PER-CENT O014500600013 106. 0.4 2.8 O014500600014 ENDCOMMON 3 0 O014500600015 DATA 3 32 O014500600016 E DATA ERR-S O014500600017 MEV MUB/SR/MEV PER-CENT O014500600018 119. 1.82 O014500600019 121.4 1.82 O014500600020 121.7 1.37 O014500600021 124.3 1.22 O014500600022 127. 1.1 O014500600023 129.6 0.92 O014500600024 131.2 0.668 O014500600025 132.3 0.617 O014500600026 134.9 0.505 O014500600027 136.8 0.448 O014500600028 139.2 0.367 O014500600029 140.2 0.3 O014500600030 142.9 0.246 O014500600031 145.5 0.227 O014500600032 147.1 0.165 O014500600033 148.2 0.135 O014500600034 150.8 0.111 O014500600035 153.5 0.835 E-01 O014500600036 155.1 0.684 E-01 O014500600037 157.7 0.497 E-01 O014500600038 158.8 0.407 E-01 O014500600039 161.4 0.273 E-01 O014500600040 163. 0.206 E-01 O014500600041 165.7 0.15 E-01 O014500600042 166.7 0.1003E-01 O014500600043 168.3 0.773 E-02 O014500600044 170.9 0.508 E-02 O014500600045 173.3 0.416 E-02 14. O014500600046 174.7 0.247 E-02 16. O014500600047 177.3 0.111 E-02 21. O014500600048 179.2 0.84 E-03 30. O014500600049 181.5 0.745 E-03 28. O014500600050 ENDDATA 34 0 O014500600051 ENDSUBENT 50 0 O014500699999 SUBENT O0145007 19950629 0000O014500700001 BIB 4 7 O014500700002 REACTION (1-H-1(P,EL)1-H-1,,DA,,,EXP) O014500700003 SAMPLE A POLYETHYLENE TARGET (CH2) WAS USED. O014500700004 ERR-ANALYS (DATA-ERR).DATA-POINT READER UNCERTAINTY. O014500700005 (ANG-ERR).DATA-POINT READER UNCERTAINTY. O014500700006 COMMENT * BY AUTHORS* OUR EXPERIMENTAL DATA ARE IN GOOD O014500700007 AGREEMENT WITH THOSE CALCULATED FROM PHASE SHIFTO014500700008 ANALYSIS. O014500700009 ENDBIB 7 0 O014500700010 COMMON 2 3 O014500700011 ANG-ERR DATA-ERR O014500700012 ADEG MB/SR O014500700013 0.004 0.06 O014500700014 ENDCOMMON 3 0 O014500700015 DATA 2 6 O014500700016 ANG DATA O014500700017 ADEG MB/SR O014500700018 18.51 15.71 O014500700019 19.5 15.3 O014500700020 20.48 14.89 O014500700021 21.59 14.75 O014500700022 22.45 14.46 O014500700023 23.56 13.93 O014500700024 ENDDATA 8 0 O014500700025 ENDSUBENT 24 0 O014500799999 ENDENTRY 7 0 O014599999999