ENTRY M0871 20180213 M094M087100000001 SUBENT M0871001 20180213 M094M087100100001 BIB 10 23 M087100100002 TITLE Study of the isomeric ratios in M087100100003 107Ag(gamma,n)106m,gAg reaction of natural silver M087100100004 induced by Bremsstrahlung with end-point energies in M087100100005 the giant dipole resonance region. M087100100006 AUTHOR (Tran Duc Thiep,Truong Thi An,Phan Viet Cuong, M087100100007 Nguyen The Vinh,Bui Minh Hue,A.G.Belov,O.D.Maslov) M087100100008 REFERENCE (J,JRN,299,477,2014) M087100100009 #doi:10.1007/s10967-013-2727-0 M087100100010 INSTITUTE (3VN IPH,4ZZZDUB) M087100100011 FACILITY (MICRT,4ZZZDUB) Electron accelerator Microtron MT-25 M087100100012 of the Flerov Laboratory of Nuclear Reaction, Joint M087100100013 Institute for Nuclear Research, Dubna, Russia. M087100100014 INC-SOURCE (BRST) M087100100015 SAMPLE Natural silver metal with purity of 99.99 % in disk M087100100016 shape 1 cm in diameter. M087100100017 DETECTOR (HPGE) High-energy resolution (1.80 keV at gamma ray M087100100018 1332 keV of 60Co) HP(Ge) semiconductor detector M087100100019 Canberra. M087100100020 METHOD (ACTIV) Induced gamma-activity was measured. M087100100021 HISTORY (20140314C) Data were compiled at MSU SINP CDFE by M087100100022 V.Varlamov. M087100100023 (20180213U) Corrected by SD and VV: REFERENCE (Vol. M087100100024 numb. corrected), STATUS. M087100100025 ENDBIB 23 0 M087100100026 NOCOMMON 0 0 M087100100027 ENDSUBENT 26 0 M087100199999 SUBENT M0871002 20180213 M094M087100200001 BIB 6 23 M087100200002 REACTION (47-AG-107(G,N)47-AG-106-M/G,,SIG/RAT,,BRA) M087100200003 DECAY-DATA (47-AG-106-M,8.28D,DG,221.7,.0661) M087100200004 (47-AG-106-G,24.MIN,DG,621.9,.0032), M087100200005 ERR-ANALYS Data for uncertainty sources are presented in the M087100200006 Table 3: M087100200007 (ERR-S) Statistical, 1.%. M087100200008 (ERR-1) Detector efficiency, 2.%. M087100200009 (ERR-2,.17,.24) Half-life, from .17 to .24%. M087100200010 (ERR-3) Branching ratio, 2.5% M087100200011 (ERR-4) Sample to detector, 1.%. M087100200012 (ERR-5) Gamma ray selection, 1.%. M087100200013 (ERR-6) Electron beam variation, 1.%. M087100200014 (ERR-7) Coincidence summing, 1.%. M087100200015 (ERR-8) Gamma ray self-absorption, 1.%. M087100200016 (ERR-9) Irradiation and cooling time, 1.%. M087100200017 (ERR-SYS) Systematics, 3.%. M087100200018 (ERR-T) Total uncertainties, ~ 6.5%. M087100200019 CRITIQUE In contradiction to content of the Table 3 the total M087100200020 uncertainties of the isomeric ratio is defined as M087100200021 "~ 6.5%" because correct individual data for ERR-T M087100200022 are presented in the Table 4. M087100200023 STATUS (TABLE) Data from Table 4. M087100200024 HISTORY (20180213U) Corrected by SD and VV: STATUS. M087100200025 ENDBIB 23 0 M087100200026 COMMON 11 6 M087100200027 ERR-S ERR-1 ERR-3 ERR-4 ERR-3 ERR-5 M087100200028 ERR-6 ERR-7 ERR-8 ERR-9 ERR-SYS M087100200029 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT M087100200030 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT M087100200031 1. 2. 2.5 5. 1. 1. M087100200032 1. 1. 1. 1. 3. M087100200033 ENDCOMMON 6 0 M087100200034 DATA 3 11 M087100200035 EN-MAX DATA ERR-T M087100200036 MEV NO-DIM NO-DIM M087100200037 14. .0260 .0017 M087100200038 15. .0210 .0014 M087100200039 16. .0160 .0011 M087100200040 17. .015 .001 M087100200041 18. .0140 .0009 M087100200042 19. .0130 .0009 M087100200043 20. .0120 .0008 M087100200044 21. .0110 .0007 M087100200045 22. .0100 .0006 M087100200046 23. .0110 .0007 M087100200047 24. .0100 .0006 M087100200048 ENDDATA 13 0 M087100200049 ENDSUBENT 48 0 M087100299999 ENDENTRY 2 0 M087199999999