ENTRY L0198 20150119 L026L019800000001 SUBENT L0198001 20150119 L026L019800100001 BIB 9 25 L019800100002 TITLE Validating resonance properties using nuclear L019800100003 resonance fluorescence L019800100004 AUTHOR (C.T.Angell,R.Hajima,T.Hayakawa,T.Shizuma, L019800100005 H.J.Karwowski,J.Silano) L019800100006 INSTITUTE (2JPNJAE,1USANCA,1USATNL) L019800100007 REFERENCE (J,PR/C,90,054315,2014) L019800100008 FACILITY (ESTRG,1USATNL) Experiment performed at the High L019800100009 Intensity Gamma-Ray Source (HIGS) at Triangle L019800100010 University Nuclear Laboratory in Durham L019800100011 SAMPLE Al scattering target with thickness of 2.53 cm. L019800100012 DETECTOR (HPGE) Scattered photons were measured by four 60% L019800100013 HPGe detectors which were on average of 12 cm from L019800100014 the target, at a scattering angle of 120deg, with two L019800100015 in the horizontal plane, and two in the vertical L019800100016 plane. They were shielded with 2.5-cm Pb on the L019800100017 sides, and Pb (0.55 cm) and Cu (0.4 cm) filters were L019800100018 placed in front of the detectors to reduce the L019800100019 intensity of low energy photons hitting the detector. L019800100020 INC-SOURCE (LCS) A circular polarized gamma-ray beam was produced L019800100021 by Compton backscattering of laser photons from L019800100022 relativistic electrons in a storage ring. The levels L019800100023 were simultaneously excited by NRF using the high-flux L019800100024 of 1E+8 photons/s circularly polarized L019800100025 quasimonoenergetic gamma-ray beam L019800100026 HISTORY (20150119C) Compiled by S.H. L019800100027 ENDBIB 25 0 L019800100028 NOCOMMON 0 0 L019800100029 ENDSUBENT 28 0 L019800199999 SUBENT L0198002 20150119 L026L019800200001 BIB 5 11 L019800200002 REACTION (13-AL-27(G,EL),,ARE) L019800200003 STATUS (TABLE) Data taken from tab. 1 of the reference L019800200004 ERR-ANALYS (ERR-S) Statistical uncertainty L019800200005 (ERR-1) Reducible systematic uncertainty due to beam L019800200006 profile ratio and subtraction of Compton scattering L019800200007 spectrum in monitor detector. L019800200008 (ERR-2) Irreducible statistical uncertainty, due to L019800200009 normalization to 2.982 MeV level and thick target L019800200010 correction. L019800200011 MONITOR (13-AL-27(G,EL),,ARE) L019800200012 CORRECTION Thick target correction was made. L019800200013 ENDBIB 11 0 L019800200014 COMMON 1 3 L019800200015 EN-RES-NRM L019800200016 MEV L019800200017 2.982 L019800200018 ENDCOMMON 3 0 L019800200019 DATA 7 1 L019800200020 EN-RES DATA ERR-S ERR-1 ERR-2 MONIT L019800200021 MONIT-ERR L019800200022 MEV B*EV B*EV B*EV B*EV B*EV L019800200023 B*EV L019800200024 3.004 3.30 0.04 0.02 0.09 31.9 L019800200025 0.7 L019800200026 ENDDATA 6 0 L019800200027 ENDSUBENT 26 0 L019800299999 ENDENTRY 2 0 L019899999999