ENTRY L0177 20121113 L021L017700000001 SUBENT L0177001 20121113 L021L017700100001 BIB 10 27 L017700100002 TITLE Compton scattering from 6Li at 60 MeV L017700100003 AUTHOR (L.S.Myers,M.W.Ahmed,G.Feldman,S.S.Henshaw,M.A.Kovash, L017700100004 J.M.Mueller,H.R.Weller) L017700100005 INSTITUTE (1USATNL,1USAGWU,1USAKTY,1USANCC) L017700100006 REFERENCE (J,PR/C,86,044614,2012) L017700100007 FACILITY (ESTRG,1USATNL)Experiment performed at the Duke L017700100008 University electron storage ring using High-Intensity L017700100009 Gamma-ray Source (HIgS). L017700100010 DETECTOR (NAICR) Array of eight large-volume NaI(Tl) detectors L017700100011 placed at roughly equally spaced angles from 40deg to L017700100012 160deg.Each NaI(Tl) detector core measures L017700100013 approximately 25.4 cm in diameter and 30.5 cm long. L017700100014 Surrounding the core detector is a segmented NaI(Tl) L017700100015 annular detector that is 7.5 cm thick and 30.5 cm L017700100016 long and is designed as an anticoincidence shield. L017700100017 The detector-response line shapes from the core L017700100018 detectors had a full width at half maximum of approx. L017700100019 6% at 60 MeV L017700100020 METHOD (TOF) Time of flight method was used to select prompt L017700100021 gamma ray events to reduce background L017700100022 INC-SOURCE (LCS) Photons were produced via Compton L017700100023 backscattering of free-electron laser (FEL) photons L017700100024 from relativistic electrons in one of the two L017700100025 straight sections of electron storage ring. L017700100026 ERR-ANALYS (ERR-S) Statistical uncertainty L017700100027 (ERR-SYS) Systematic uncertainty L017700100028 HISTORY (20121113C) Compiled by S.H. L017700100029 ENDBIB 27 0 L017700100030 COMMON 2 3 L017700100031 EN EN-RSL L017700100032 MEV MEV L017700100033 60.0 2.7 L017700100034 ENDCOMMON 3 0 L017700100035 ENDSUBENT 34 0 L017700199999 SUBENT L0177002 20121113 L021L017700200001 BIB 3 5 L017700200002 REACTION (8-O-16(G,EL)8-O-16,,DA) L017700200003 STATUS (TABLE) Data taken from tab. 1 of the reference L017700200004 SAMPLE The oxygen target consisted of distilled water in a L017700200005 Lucite cylinder 10.0 cm long and 5.0 cm in diameter, L017700200006 yielding an oxygen target thickness of 10.0+-0.1 g/cm2.L017700200007 ENDBIB 5 0 L017700200008 NOCOMMON 0 0 L017700200009 DATA 4 8 L017700200010 ANG DATA ERR-S ERR-SYS L017700200011 ADEG NB/SR NB/SR NB/SR L017700200012 40.0 1427.0 50.0 48.0 L017700200013 55.0 1143.0 50.0 39.0 L017700200014 75.0 843.0 49.0 29.0 L017700200015 90.0 915.0 44.0 31.0 L017700200016 110.0 854.0 48.0 29.0 L017700200017 125.0 992.0 39.0 34.0 L017700200018 145.0 1256.0 51.0 43.0 L017700200019 159.0 1262.0 47.0 43.0 L017700200020 ENDDATA 10 0 L017700200021 ENDSUBENT 20 0 L017700299999 SUBENT L0177003 20121113 L021L017700300001 BIB 3 6 L017700300002 REACTION (3-LI-6(G,EL)3-LI-6,,DA) L017700300003 STATUS (TABLE) Data taken from tab. 1 of the reference L017700300004 SAMPLE The 6Li target cell consists of a polyvinyl chloride L017700300005 cylinder with PVC and Al foil end caps. It measures L017700300006 12.7 cm in length with a diameter of 4.1 cm for a L017700300007 target thickness of 5.84+-0.06 g/cm2. L017700300008 ENDBIB 6 0 L017700300009 NOCOMMON 0 0 L017700300010 DATA 4 8 L017700300011 ANG DATA ERR-S ERR-SYS L017700300012 ADEG NB/SR NB/SR NB/SR L017700300013 40.0 196.0 10.0 6.0 L017700300014 55.0 176.0 8.0 6.0 L017700300015 75.0 125.0 7.0 4.0 L017700300016 90.0 135.0 7.0 4.0 L017700300017 110.0 139.0 8.0 5.0 L017700300018 125.0 177.0 9.0 6.0 L017700300019 145.0 178.0 9.0 6.0 L017700300020 159.0 198.0 8.0 6.0 L017700300021 ENDDATA 10 0 L017700300022 ENDSUBENT 21 0 L017700399999 ENDENTRY 3 0 L017799999999