ENTRY K2385 20150519 K015K238500000001 SUBENT K2385001 20150519 K015K238500100001 BIB 12 30 K238500100002 TITLE Total and partial photoneutron cross sections for Pb K238500100003 isotopes K238500100004 AUTHOR (T.Kondo, H.Utsunomiya, S.Goriely, I.Daoutidis, K238500100005 C.Iwamoto, H.Akimune, A.Okamoto, T.Yamagata, M.Kamata,K238500100006 O.Itoh, H.Toyokawa, Y.-W.Lui, H.Harada, F.Kitatani, K238500100007 S.Hilaire, A.J.Koning) K238500100008 INSTITUTE (2JPNKON) Department of Physics K238500100009 (2BLGBRU) Institut di Astronomie et di Astrophysique K238500100010 (2JPNAIS) K238500100011 (1USATAM) Cyclotron Institute K238500100012 (2JPNJAE) K238500100013 (2FR BRC) K238500100014 (2NEDNRG) K238500100015 REFERENCE (J,PR/C,86,014316,2012) K238500100016 PART-DET (N) K238500100017 INC-SOURCE (LCS) Lambda=532 nm photons at 24W and 1064 nm photons K238500100018 at 40W. K238500100019 SAMPLE - Chemical-form of target is element. K238500100020 - Physical-form of target is solid. K238500100021 METHOD (RINGR) The average neutron energy was determined. K238500100022 FACILITY (ESTRG,2JPNAIS) Tsukuba Electron Ring for Acceleration K238500100023 and Storage (TERAS) storage ring. K238500100024 DETECTOR Efficiency: The detection efficiency was 60-74% in the K238500100025 energy range less than 1 MeV. K238500100026 ERR-ANALYS (ERR-1) neutron detection efficiency K238500100027 (ERR-2) number of incident gamma rays K238500100028 HISTORY (20120820C) M.O. & A.Makinaga K238500100029 (20141025R) Received by e-mail from H. Utsunomiya K238500100030 (20150519A) MA: HISTORY: information of author's K238500100031 contribution added. K238500100032 ENDBIB 30 0 K238500100033 COMMON 2 3 K238500100034 ERR-1 ERR-2 K238500100035 PER-CENT PER-CENT K238500100036 3.2 3.0 K238500100037 ENDCOMMON 3 0 K238500100038 ENDSUBENT 37 0 K238500199999 SUBENT K2385002 20130906 K013K238500200001 BIB 6 18 K238500200002 REACTION (82-PB-208(G,N)82-PB-207,,SIG) K238500200003 SAMPLE Target-thickness is 1.99E+03 mg/cm**2. K238500200004 (82-PB-208,ENR=0.997) K238500200005 DETECTOR (PROPC) A high-efficiency 4pi neutron detector K238500200006 composed of triple rings of 20 3He K238500200007 proportional counters altogether embedded in a K238500200008 polyethylene moderator was used for neutron K238500200009 detection. K238500200010 (NAICR) The number of the LCS gamma rays incident on K238500200011 the targets was determined from pileup- and K238500200012 single-photon spectra. K238500200013 (HPGE) The LCS gamma-ray beam was measured with a 120% K238500200014 high-purity germanium detector (HPGe) at a K238500200015 reduced laser power. K238500200016 ERR-ANALYS (ERR-S) Statistical uncertainty K238500200017 ADD-RES Total (E1+M1) cross sections at 4 energies (7.51, K238500200018 7.77, 8.16, 8.32 MeV) shown in Fig.3 K238500200019 STATUS (TABLE) Plotted in Fig.3 of PRC, 86, 014316(2012) K238500200020 ENDBIB 18 0 K238500200021 NOCOMMON 0 0 K238500200022 DATA 3 12 K238500200023 EN DATA ERR-S K238500200024 MEV MB MB K238500200025 7.53 36.19 1.93 K238500200026 7.83 24.33 0.48 K238500200027 8.25 24.76 0.44 K238500200028 8.54 38.92 1.20 K238500200029 8.85 48.47 1.28 K238500200030 9.32 77.42 1.74 K238500200031 9.84 93.02 5.83 K238500200032 9.98 112.93 6.87 K238500200033 10.57 193.52 7.46 K238500200034 11.11 240.38 10.87 K238500200035 11.55 335.68 14.25 K238500200036 12.24 424.48 15.20 K238500200037 ENDDATA 14 0 K238500200038 ENDSUBENT 37 0 K238500299999 SUBENT K2385003 20130906 K013K238500300001 BIB 6 18 K238500300002 REACTION (82-PB-207(G,N)82-PB-206,,SIG) K238500300003 SAMPLE Target-thickness is 1.98E+03 mg/cm**2. K238500300004 (82-PB-207,ENR=0.991) K238500300005 DETECTOR (PROPC) A high-efficiency 4pi neutron detector K238500300006 composed of triple rings of 20 3He K238500300007 proportional counters altogether embedded in a K238500300008 polyethylene moderator was used for neutron K238500300009 detection. K238500300010 (NAICR) The number of the LCS gamma rays incident on K238500300011 the targets was determined from pileup- and K238500300012 single-photon spectra measured. K238500300013 (HPGE) The LCS gamma-ray beam was measured with a 120% K238500300014 high-purity germanium detector (HPGe) at a K238500300015 reduced laser power. K238500300016 ERR-ANALYS (ERR-S) Statistical uncertainty K238500300017 ADD-RES Total (E1+M1) cross sections at 4 energies (7.02, K238500300018 7.24, 7.52, 8.11 MeV) shown in Fig.5 K238500300019 STATUS (TABLE) Plotted in Fig.5 of PRC, 86, 014316(2012) K238500300020 ENDBIB 18 0 K238500300021 NOCOMMON 0 0 K238500300022 DATA 3 14 K238500300023 EN DATA ERR-S K238500300024 MEV MB MB K238500300025 6.84 12.38 1.05 K238500300026 6.99 17.82 1.16 K238500300027 7.26 23.56 0.59 K238500300028 7.64 25.78 0.55 K238500300029 8.40 24.71 0.47 K238500300030 8.69 34.79 0.77 K238500300031 8.82 31.20 0.91 K238500300032 9.23 61.62 1.24 K238500300033 9.77 74.62 3.46 K238500300034 9.89 96.24 4.27 K238500300035 10.50 147.34 5.92 K238500300036 11.07 210.35 8.10 K238500300037 11.53 283.04 10.60 K238500300038 12.22 401.73 14.86 K238500300039 ENDDATA 16 0 K238500300040 ENDSUBENT 39 0 K238500399999 SUBENT K2385004 20130906 K013K238500400001 BIB 5 16 K238500400002 REACTION (82-PB-206(G,N)82-PB-205,,SIG) K238500400003 SAMPLE Target-thickness is 1.56E+03 mg/cm**2. K238500400004 (82-PB-206,ENR=0.993) K238500400005 DETECTOR (PROPC) A high-efficiency 4pi neutron detector K238500400006 composed of triple rings of 20 3He K238500400007 proportional counters altogether embedded in a K238500400008 polyethylene moderator was used for neutron K238500400009 detection. K238500400010 (NAICR) The number of the LCS gamma rays incident on K238500400011 the targets was determined from pileup- and K238500400012 single-photon spectra measured. K238500400013 (HPGE) The LCS gamma-ray beam was measured with a 120% K238500400014 high-purity germanium detector (HPGe) at a K238500400015 reduced laser power. K238500400016 ERR-ANALYS (ERR-S) Statistical uncertainty K238500400017 STATUS (TABLE) Plotted in Fig.8 of PRC, 86, 014316(2012) K238500400018 ENDBIB 16 0 K238500400019 NOCOMMON 0 0 K238500400020 DATA 3 11 K238500400021 EN DATA ERR-S K238500400022 MEV MB MB K238500400023 8.14 24.88 1.98 K238500400024 8.45 23.49 0.56 K238500400025 8.74 37.71 1.40 K238500400026 9.07 48.10 1.00 K238500400027 9.46 66.51 1.40 K238500400028 9.94 86.75 3.28 K238500400029 10.11 100.88 4.83 K238500400030 10.65 171.65 7.73 K238500400031 11.17 228.15 9.11 K238500400032 11.62 275.53 11.18 K238500400033 12.24 408.42 17.67 K238500400034 ENDDATA 13 0 K238500400035 ENDSUBENT 34 0 K238500499999 SUBENT K2385005 20130906 K013K238500500001 BIB 6 11 K238500500002 REACTION (82-PB-208(G,N)82-PB-207,EP,SIG) K238500500003 INC-SOURCE (POLIS) K238500500004 SAMPLE Target-thickness: 9587 mg K238500500005 (82-PB-208,ENR=0.985) K238500500006 DETECTOR (LONGC) Five 3He proportional counters, polyethylene K238500500007 moderator, and twelve neutron-guiding holes. K238500500008 ERR-ANALYS (ERR-SYS) from polarization and neutron detection K238500500009 efficiency and number of gamma rays K238500500010 (ERR-S) from neutron yields for vertical and K238500500011 horizontal detectors K238500500012 STATUS (TABLE) Presented in Table I of PRC, 86, 014316(2012) K238500500013 ENDBIB 11 0 K238500500014 COMMON 3 3 K238500500015 POL-BM POL-BM-ERR POLAR K238500500016 NO-DIM NO-DIM NO-DIM K238500500017 0.934 0.007 1. K238500500018 ENDCOMMON 3 0 K238500500019 DATA 4 4 K238500500020 EN DATA ERR-S ERR-SYS K238500500021 MEV MB MB MB K238500500022 7.51 39.31 2.56 2.59 K238500500023 7.77 28.52 1.38 1.82 K238500500024 8.16 28.20 1.28 1.79 K238500500025 8.32 33.19 0.82 2.13 K238500500026 ENDDATA 6 0 K238500500027 ENDSUBENT 26 0 K238500599999 SUBENT K2385006 20130906 K013K238500600001 BIB 7 13 K238500600002 REACTION (82-PB-208(G,N)82-PB-207,MP,SIG) K238500600003 INC-SOURCE (POLIS) K238500600004 SAMPLE Target-thickness: 9587 mg K238500600005 (82-PB-208,ENR=0.985) K238500600006 DETECTOR (LONGC) Five 3He proportional counters, polyethylene K238500600007 moderator, and twelve neutron-guiding holes. K238500600008 ERR-ANALYS (ERR-SYS) from polarization and neutron detection K238500600009 efficiency and number of gamma rays K238500600010 (ERR-S) from neutron yields for vertical and K238500600011 horizontal detectors K238500600012 COMMENT systematic uncertainty of the neutron yields are also K238500600013 included. K238500600014 STATUS (TABLE) Presented in Table I of PRC, 86, 014316(2012) K238500600015 ENDBIB 13 0 K238500600016 COMMON 3 3 K238500600017 POL-BM POL-BM-ERR POLAR K238500600018 NO-DIM NO-DIM NO-DIM K238500600019 0.934 0.007 1. K238500600020 ENDCOMMON 3 0 K238500600021 DATA 4 4 K238500600022 EN DATA ERR-S ERR-SYS K238500600023 MEV MB MB MB K238500600024 7.51 0.66 1.29 0.08 K238500600025 7.77 1.90 0.73 0.22 K238500600026 8.16 3.09 0.69 0.36 K238500600027 8.32 1.86 0.42 0.21 K238500600028 ENDDATA 6 0 K238500600029 ENDSUBENT 28 0 K238500699999 SUBENT K2385007 20130906 K013K238500700001 BIB 6 11 K238500700002 REACTION (82-PB-207(G,N)82-PB-206,EP,SIG) K238500700003 INC-SOURCE (POLIS) K238500700004 SAMPLE Target-thickness: 3482 mg K238500700005 (82-PB-207,ENR=0.991) K238500700006 DETECTOR (LONGC) Five 3He proportional counters, polyethylene K238500700007 moderator, and twelve neutron-guiding holes. K238500700008 ERR-ANALYS (ERR-SYS) from polarization and neutron detection K238500700009 efficiency and number of gamma rays K238500700010 (ERR-S) from neutron yields for vertical and K238500700011 horizontal detectors K238500700012 STATUS (TABLE) Presented in Table II of PRC, 86, 014316(2012) K238500700013 ENDBIB 11 0 K238500700014 COMMON 3 3 K238500700015 POL-BM POL-BM-ERR POLAR K238500700016 NO-DIM NO-DIM NO-DIM K238500700017 0.934 0.007 1. K238500700018 ENDCOMMON 3 0 K238500700019 DATA 4 4 K238500700020 EN DATA ERR-S ERR-SYS K238500700021 MEV MB MB MB K238500700022 7.02 16.03 1.63 1.04 K238500700023 7.24 24.53 2.22 1.56 K238500700024 7.52 25.80 1.69 1.63 K238500700025 8.11 31.03 6.56 2.16 K238500700026 ENDDATA 6 0 K238500700027 ENDSUBENT 26 0 K238500799999 SUBENT K2385008 20130906 K013K238500800001 BIB 6 11 K238500800002 REACTION (82-PB-207(G,N)82-PB-206,MP,SIG) K238500800003 INC-SOURCE (POLIS) K238500800004 SAMPLE Target-thickness: 3482 mg K238500800005 (82-PB-207,ENR=0.991) K238500800006 DETECTOR (LONGC) Five 3He proportional counters, polyethylene K238500800007 moderator, and twelve neutron-guiding holes. K238500800008 ERR-ANALYS (ERR-SYS) from polarization and neutron detection K238500800009 efficiency and number of gamma rays K238500800010 (ERR-S) from neutron yields for vertical and K238500800011 horizontal detectors K238500800012 STATUS (TABLE) Presented in Table II of PRC, 86, 014316(2012) K238500800013 ENDBIB 11 0 K238500800014 COMMON 3 3 K238500800015 POL-BM POL-BM-ERR POLAR K238500800016 NO-DIM NO-DIM NO-DIM K238500800017 0.934 0.007 1. K238500800018 ENDCOMMON 3 0 K238500800019 DATA 4 4 K238500800020 EN DATA ERR-S ERR-SYS K238500800021 MEV MB MB MB K238500800022 7.02 2.97 0.98 0.35 K238500800023 7.24 2.99 1.24 0.34 K238500800024 7.52 2.65 0.91 0.30 K238500800025 8.11 -0.94 3.03 0.11 K238500800026 ENDDATA 6 0 K238500800027 ENDSUBENT 26 0 K238500899999 ENDENTRY 8 0 K238599999999