ENTRY K2293 20110502 K010K229300000001 SUBENT K2293001 20110502 K010K229300100001 BIB 12 20 K229300100002 TITLE Study on effective average (g,n) cross section for K229300100003 89Y, 90Zr, 93Nb, and 133Cs and (g,3n) cross section K229300100004 for 99Tc K229300100005 AUTHOR (A.K.Md.L.Rahman, K.Kato, H.Arima, N.Shigyo, K229300100006 K.Ishibashi, J.Hori, K.Nakajima) K229300100007 INSTITUTE (2JPNKYU) Department of Applied Quantum Physics and K229300100008 Nuclear Engineering K229300100009 (2JPNKTO) Research Reactor Institute K229300100010 REFERENCE (J,NST,47,(7),618,201007) K229300100011 MONITOR (79-AU-197(G,N)79-AU-196,,SIG) K229300100012 MONIT-REF (L0021001,A.Veyssierre+,J,NP/A,159,561,197012) K229300100013 The photon flux was normalized with the Saclay data. K229300100014 INC-SOURCE (BRST) Pt radiator K229300100015 SAMPLE Physical-form of target is solid. K229300100016 FACILITY (LINAC,2JPNKTO) Research Reactor Institute K229300100017 DETECTOR Au foil was used for flux monitor. K229300100018 (HPGE) K229300100019 CORRECTION Contribution of secondary neutron reaction K229300100020 197Au(n,2n)196Au (0.02%) was considered. K229300100021 HISTORY (20101203C) Ayano Makinaga K229300100022 ENDBIB 20 0 K229300100023 NOCOMMON 0 0 K229300100024 ENDSUBENT 23 0 K229300199999 SUBENT K2293002 20110502 K010K229300200001 BIB 7 16 K229300200002 REACTION (39-Y-89(G,N)39-Y-88,,SIG,,BRA) K229300200003 DECAY-DATA (79-AU-196,,DG,355.73,0.87) K229300200004 (79-AU-198,,DG,411.80,0.956) K229300200005 (39-Y-88,,DG,898.,0.937, K229300200006 DG,1836.,0.99) K229300200007 INC-SOURCE Beam intensity is 13.10 micro-Ampere. K229300200008 SAMPLE - Chemical-form of target: Y2O3 K229300200009 - Target-thickness: 0.03475 g and 9-mm-diameter K229300200010 pellets K229300200011 METHOD (ACTIV) Irradiation time is 1390 sec. K229300200012 ERR-ANALYS (ERR-T) Total uncertainty K229300200013 (ERR-1) Sample weight K229300200014 (ERR-2) Efficiency calibration K229300200015 (ERR-3) Flux energy distribution K229300200016 (ERR-S) Counting statistics K229300200017 STATUS (TABLE) Tabulated in Table 2 of J,NST,vol.47,p618,2010 K229300200018 ENDBIB 16 0 K229300200019 COMMON 3 3 K229300200020 ERR-1 ERR-2 ERR-3 K229300200021 PER-CENT PER-CENT PER-CENT K229300200022 0.2 1.8 2.0 K229300200023 ENDCOMMON 3 0 K229300200024 DATA 4 1 K229300200025 EN-MAX DATA ERR-T ERR-S K229300200026 MEV B B PER-CENT K229300200027 32. 0.0776 0.0021 0.5 K229300200028 ENDDATA 3 0 K229300200029 ENDSUBENT 28 0 K229300299999 SUBENT K2293003 20110502 K010K229300300001 BIB 8 15 K229300300002 REACTION (40-ZR-90(G,N)40-ZR-89,,SIG,,BRA) K229300300003 DECAY-DATA (79-AU-196,,DG,355.73,0.87) K229300300004 (79-AU-198,,DG,411.80,0.956) K229300300005 INC-SOURCE Beam intensity is 13.08 micro-Ampere. K229300300006 SAMPLE Target-thickness: 9-mm-diameter foil. The thickness is K229300300007 0.05 mm K229300300008 METHOD (ACTIV) Irradiation time is 3660 sec. K229300300009 CORRECTION Corrected for 91Zr(g,2n)89Zr contribution K229300300010 (9.00+/-1.41%) K229300300011 ERR-ANALYS (ERR-T) Total uncertainty K229300300012 (ERR-1) Sample weight K229300300013 (ERR-2) Efficiency calibration K229300300014 (ERR-3) Flux energy distribution K229300300015 (ERR-S) Counting statistics K229300300016 STATUS (TABLE) Tabulated in Table 2 of J,NST,vol.47,p618,2010 K229300300017 ENDBIB 15 0 K229300300018 COMMON 3 3 K229300300019 ERR-1 ERR-2 ERR-3 K229300300020 PER-CENT PER-CENT PER-CENT K229300300021 0.2 3.3 2.5 K229300300022 ENDCOMMON 3 0 K229300300023 DATA 4 1 K229300300024 EN-MAX DATA ERR-T ERR-S K229300300025 MEV B B PER-CENT K229300300026 32. 0.0678 0.0031 0.3 K229300300027 ENDDATA 3 0 K229300300028 ENDSUBENT 27 0 K229300399999 SUBENT K2293004 20110502 K010K229300400001 BIB 7 14 K229300400002 REACTION (41-NB-93(G,N)41-NB-92-M,,SIG,,BRA) K229300400003 DECAY-DATA (79-AU-196,,DG,355.73,0.87) K229300400004 (79-AU-198,,DG,411.80,0.956) K229300400005 (41-NB-92-M,10.15D,DG,934.4,0.99) K229300400006 INC-SOURCE Beam intensity is 37 micro-Ampere. K229300400007 SAMPLE Target-thickness: 9-mm-diameter foil. The thickness is K229300400008 0.0254 mm K229300400009 METHOD (ACTIV) Irradiation time is 900 sec. K229300400010 ERR-ANALYS (ERR-T) Total uncertainty K229300400011 (ERR-1) Sample weight K229300400012 (ERR-2) Efficiency calibration K229300400013 (ERR-3) Flux energy distribution K229300400014 (ERR-S) Counting statistics K229300400015 STATUS (TABLE) Tabulated in Table 2 of J,NST,vol.47,p618,2010 K229300400016 ENDBIB 14 0 K229300400017 COMMON 3 3 K229300400018 ERR-1 ERR-2 ERR-3 K229300400019 PER-CENT PER-CENT PER-CENT K229300400020 0.22 4.0 5.0 K229300400021 ENDCOMMON 3 0 K229300400022 DATA 4 1 K229300400023 EN-MAX DATA ERR-T ERR-S K229300400024 MEV B B PER-CENT K229300400025 32. 0.0299 0.0019 0.9 K229300400026 ENDDATA 3 0 K229300400027 ENDSUBENT 26 0 K229300499999 SUBENT K2293005 20110502 K010K229300500001 BIB 7 13 K229300500002 REACTION (55-CS-133(G,N)55-CS-132,,SIG,,BRA) K229300500003 DECAY-DATA (79-AU-196,,DG,355.73,0.87) K229300500004 (79-AU-198,,DG,411.80,0.956) K229300500005 INC-SOURCE Beam intensity is 13.10 micro-Ampere. K229300500006 SAMPLE - Chemical-form of target: CsBr K229300500007 - Target-thickness: 0.03517 g. 9-mm-diameter pellet. K229300500008 METHOD (ACTIV) Irradiation time is 1390 sec. K229300500009 ERR-ANALYS (ERR-T) Total uncertainty K229300500010 (ERR-1) Sample weight K229300500011 (ERR-2) Efficiency calibration K229300500012 (ERR-3) Flux energy distribution K229300500013 (ERR-S) Counting statistics K229300500014 STATUS (TABLE) Tabulated in Table 2 of J,NST,vol.47,p618,2010 K229300500015 ENDBIB 13 0 K229300500016 COMMON 3 3 K229300500017 ERR-1 ERR-2 ERR-3 K229300500018 PER-CENT PER-CENT PER-CENT K229300500019 0.03 2.1 2. K229300500020 ENDCOMMON 3 0 K229300500021 DATA 4 1 K229300500022 EN-MAX DATA ERR-T ERR-S K229300500023 MEV B B PER-CENT K229300500024 32. 0.1032 0.0030 0.1 K229300500025 ENDDATA 3 0 K229300500026 ENDSUBENT 25 0 K229300599999 SUBENT K2293006 20110502 K010K229300600001 BIB 8 16 K229300600002 REACTION (43-TC-99(G,3N)43-TC-96,,SIG,,BRA) K229300600003 DECAY-DATA (79-AU-196,,DG,355.73,0.87) K229300600004 (79-AU-198,,DG,411.80,0.956) K229300600005 (43-TC-96,,DG,778.,0.9976) K229300600006 PART-DET (DG) K229300600007 INC-SOURCE Beam intensity is 24.8 micro-Ampere. K229300600008 SAMPLE - Chemical-form of target: TcO2 K229300600009 - Target-thickness: 72.5 mg. K229300600010 METHOD (ACTIV) Irradiation time is 3600 sec. K229300600011 ERR-ANALYS (ERR-T) Total uncertainty K229300600012 (ERR-1) Flux at the target position K229300600013 (ERR-2) Flux energy distribution K229300600014 (ERR-3) Efficiency calibration K229300600015 (ERR-4) Sample activity K229300600016 (ERR-S) Counting statistics K229300600017 STATUS (TABLE) Tabulated in Table 4 of J,NST,vol.47,p618,2010 K229300600018 ENDBIB 16 0 K229300600019 COMMON 3 3 K229300600020 ERR-1 ERR-2 ERR-3 K229300600021 PER-CENT PER-CENT PER-CENT K229300600022 0.1 2.0 5.0 K229300600023 ENDCOMMON 3 0 K229300600024 DATA 5 1 K229300600025 EN-MAX DATA ERR-T ERR-S ERR-4 K229300600026 MEV MB MB PER-CENT PER-CENT K229300600027 36. 2.30 0.17 0.7 5.4 K229300600028 ENDDATA 3 0 K229300600029 ENDSUBENT 28 0 K229300699999 ENDENTRY 6 0 K229399999999