ENTRY K2023 20070712 K002K202300000001 SUBENT K2023001 20070712 K002K202300100001 BIB 11 46 K202300100002 TITLE Target-dependence of light fragment production in K202300100003 photonuclear reactions at intermediate energies K202300100004 AUTHOR (H.Matsumura, K.Washiyama, H.Haba, Y.Miyamoto, Y.Oura, K202300100005 K.Sakamoto, S.Shibata, M.Furukawa, I.Fujiwara, K202300100006 H.Nagai, T.Kobayashi, K.Kobayashi) K202300100007 INSTITUTE (2JPNKNZ) Division of Physical Sciences, Graduate K202300100008 School of Natural Science and Technology K202300100009 (2JPNTMU) Department of Chemistry, Graduate School of K202300100010 Schience K202300100011 (2JPNKNZ) Department of Chemistry, Faculty of Science K202300100012 (2JPNKTO) Research Reactor Institute K202300100013 (2JPNJPN) Faculty of Environmental and Information K202300100014 Sciences, Yokkaichi University K202300100015 (2JPNJPN) School of Economics, Otemon Gakuin K202300100016 University, Ibaragi K202300100017 (2JPNJPN) College of Humanities and Sciences, Nihon K202300100018 University K202300100019 (2JPNTOK) Research Center for Nuclear Science and K202300100020 Technology K202300100021 REFERENCE (J,RCA,88,(6),313,200006) K202300100022 Main reference. See also TITLE and AUTHOR. K202300100023 (T,MATSUMURA,2000) K202300100024 H.Matsumura, Uncertainty in detector efficiency K202300100025 INC-SOURCE Beam intensity: 1e+09 to 1e+10 equivalent quanta per K202300100026 second K202300100027 (BRST) By internal target of Pt with 0.05 mm thickness K202300100028 METHOD (ACTIV) Irradiated for 0.5-8 hours, typically 4 hours K202300100029 (STTA) Stacked by sandwiching with Al plates K202300100030 FACILITY (SYNCH,2JPNKEK) 1.3 GeV electron synchrotron at K202300100031 Tanashi Branch K202300100032 ERR-ANALYS Uncertainty in beam-intensity calibration is not K202300100033 included in tabulated errors. K202300100034 (ERR-1) Unertainty in beam-intensity calibration in K202300100035 bremsstrahlung irradiation K202300100036 COMMENT Authors give yield with unit of [micro-barn/equivalent K202300100037 quantum]. K202300100038 Energy repetition in some data tables are from more K202300100039 than one mesurements. K202300100040 Contributions from the secondary reactions were K202300100041 assumed to be negligible by authors. K202300100042 STATUS (TABLE) Data (appendix, p323-328 in reference) K202300100043 received by e-mail from H.Matsumura K202300100044 (2007.01.26) K202300100045 (APRVD) Proofread by Hiroshi Matsumura (2007.05.17) K202300100046 HISTORY (20070126R) On. Receved by e-mail from H.Matsumura K202300100047 (20070208C) On K202300100048 ENDBIB 46 0 K202300100049 COMMON 1 3 K202300100050 ERR-1 K202300100051 PER-CENT K202300100052 15. K202300100053 ENDCOMMON 3 0 K202300100054 ENDSUBENT 53 0 K202300199999 SUBENT K2023002 20070712 K002K202300200001 BIB 5 9 K202300200002 REACTION (5-B-0(G,X)4-BE-7,IND,SIG,,BRA) K202300200003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300200004 SAMPLE - Chemical-form of target is element. K202300200005 - Physical-form of target is solid. K202300200006 - Target-thickness is 500 mg/cm**2. Typical thickness K202300200007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300200008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300200009 not included in tabulated errors. K202300200010 (ERR-2) Uncertainty in detector efficiency K202300200011 ENDBIB 9 0 K202300200012 COMMON 1 3 K202300200013 ERR-2 K202300200014 PER-CENT K202300200015 7. K202300200016 ENDCOMMON 3 0 K202300200017 DATA 3 7 K202300200018 EN-MAX DATA ERR-T K202300200019 MEV MICRO-B MICRO-B K202300200020 1000. 376. 69. K202300200021 850. 268. 48. K202300200022 700. 298. 75. K202300200023 600. 337. 62. K202300200024 475. 222. 45. K202300200025 400. 285. 59. K202300200026 325. 243. 65. K202300200027 ENDDATA 9 0 K202300200028 ENDSUBENT 27 0 K202300299999 SUBENT K2023003 20070712 K002K202300300001 BIB 5 9 K202300300002 REACTION (6-C-0(G,X)4-BE-7,IND,SIG,,BRA) K202300300003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300300004 SAMPLE - Chemical-form of target is element. K202300300005 - Physical-form of target is solid. K202300300006 - Target-thickness is 300 mg/cm**2. Typical thickness K202300300007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300300008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300300009 not included in tabulated errors. K202300300010 (ERR-2) Uncertainty in detector efficiency K202300300011 ENDBIB 9 0 K202300300012 COMMON 1 3 K202300300013 ERR-2 K202300300014 PER-CENT K202300300015 7. K202300300016 ENDCOMMON 3 0 K202300300017 DATA 3 7 K202300300018 EN-MAX DATA ERR-T K202300300019 MEV MICRO-B MICRO-B K202300300020 1000. 639. 84. K202300300021 1000. 732. 76. K202300300022 700. 644. 66. K202300300023 600. 570. 110. K202300300024 550. 596. 65. K202300300025 450. 627. 69. K202300300026 400. 590. 110. K202300300027 ENDDATA 9 0 K202300300028 ENDSUBENT 27 0 K202300399999 SUBENT K2023004 20070712 K002K202300400001 BIB 6 10 K202300400002 REACTION (8-O-0(G,X)4-BE-7,IND,SIG,,BRA) K202300400003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300400004 SAMPLE - Chemical-form of target: H2O K202300400005 - Physical-form of target is liquid. K202300400006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202300400007 METHOD (CHSEP) K202300400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300400010 not included in tabulated errors. K202300400011 (ERR-2) Uncertainty in detector efficiency K202300400012 ENDBIB 10 0 K202300400013 COMMON 1 3 K202300400014 ERR-2 K202300400015 PER-CENT K202300400016 7. K202300400017 ENDCOMMON 3 0 K202300400018 DATA 3 7 K202300400019 EN-MAX DATA ERR-T K202300400020 MEV MICRO-B MICRO-B K202300400021 1000. 378. 38. K202300400022 850. 315. 34. K202300400023 700. 290. 30. K202300400024 600. 295. 31. K202300400025 475. 244. 25. K202300400026 400. 229. 26. K202300400027 325. 169. 18. K202300400028 ENDDATA 9 0 K202300400029 ENDSUBENT 28 0 K202300499999 SUBENT K2023005 20070712 K002K202300500001 BIB 6 12 K202300500002 REACTION (11-NA-23(G,X)4-BE-7,IND,SIG,,BRA) K202300500003 Measured with NaCl target (Contribution of Cl is K202300500004 subtracted.) K202300500005 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300500006 SAMPLE - Chemical-form of target: NaCl K202300500007 - Physical-form of target is solid. K202300500008 - Target-thickness is 1000 mg/cm**2. Typical thickness K202300500009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300500010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300500011 not included in tabulated errors. K202300500012 (ERR-2) Uncertainty in detector efficiency K202300500013 STATUS (COREL,K2023009) Contribution of Cl in target K202300500014 ENDBIB 12 0 K202300500015 COMMON 1 3 K202300500016 ERR-2 K202300500017 PER-CENT K202300500018 7. K202300500019 ENDCOMMON 3 0 K202300500020 DATA 3 4 K202300500021 EN-MAX DATA ERR-T K202300500022 MEV MICRO-B MICRO-B K202300500023 1000. 174. 21. K202300500024 700. 102. 14. K202300500025 550. 127. 15. K202300500026 450. 83. 11. K202300500027 ENDDATA 6 0 K202300500028 ENDSUBENT 27 0 K202300599999 SUBENT K2023006 20070712 K002K202300600001 BIB 5 9 K202300600002 REACTION (13-AL-27(G,X)4-BE-7,IND,SIG,,BRA) K202300600003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300600004 SAMPLE - Chemical-form of target is element. K202300600005 - Physical-form of target is solid. K202300600006 - Target-thickness is 270 mg/cm**2. Typical thickness K202300600007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300600008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300600009 not included in tabulated errors. K202300600010 (ERR-2) Uncertainty in detector efficiency K202300600011 ENDBIB 9 0 K202300600012 COMMON 1 3 K202300600013 ERR-2 K202300600014 PER-CENT K202300600015 7. K202300600016 ENDCOMMON 3 0 K202300600017 DATA 3 39 K202300600018 EN-MAX DATA ERR-T K202300600019 MEV MICRO-B MICRO-B K202300600020 1100. 131. 16. K202300600021 1000. 153. 16. K202300600022 1000. 133. 14. K202300600023 1000. 172. 18. K202300600024 950. 113. 14. K202300600025 950. 116. 15. K202300600026 950. 142. 18. K202300600027 900. 119. 13. K202300600028 850. 118. 13. K202300600029 850. 119. 12. K202300600030 800. 106. 13. K202300600031 800. 96. 13. K202300600032 750. 126. 23. K202300600033 700. 130. 17. K202300600034 700. 121. 16. K202300600035 700. 123. 17. K202300600036 700. 109. 14. K202300600037 650. 79. 11. K202300600038 600. 108. 12. K202300600039 600. 108. 12. K202300600040 600. 90.8 9.9 K202300600041 550. 73.8 8.6 K202300600042 550. 77. 10. K202300600043 550. 97. 11. K202300600044 500. 72. 13. K202300600045 500. 70.5 7.7 K202300600046 475. 66.7 8.5 K202300600047 475. 80.2 9.0 K202300600048 450. 77. 13. K202300600049 450. 81. 10. K202300600050 400. 65.1 9.2 K202300600051 400. 67. 11. K202300600052 400. 58.0 8.5 K202300600053 400. 57.2 8.5 K202300600054 400. 68.2 9.4 K202300600055 350. 43.8 6.5 K202300600056 350. 43.3 5.5 K202300600057 300. 43.5 6.4 K202300600058 250. 18.2 4.0 K202300600059 ENDDATA 41 0 K202300600060 ENDSUBENT 59 0 K202300699999 SUBENT K2023007 20070712 K002K202300700001 BIB 5 9 K202300700002 REACTION (14-SI-0(G,X)4-BE-7,IND,SIG,,BRA) K202300700003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300700004 SAMPLE - Chemical-form of target is element. K202300700005 - Physical-form of target is solid. K202300700006 - Target-thickness is 300 mg/cm**2. Typical thickness K202300700007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300700008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300700009 not included in tabulated errors. K202300700010 (ERR-2) Uncertainty in detector efficiency K202300700011 ENDBIB 9 0 K202300700012 COMMON 1 3 K202300700013 ERR-2 K202300700014 PER-CENT K202300700015 7. K202300700016 ENDCOMMON 3 0 K202300700017 DATA 3 13 K202300700018 EN-MAX DATA ERR-T K202300700019 MEV MICRO-B MICRO-B K202300700020 1000. 195. 21. K202300700021 1000. 176. 20. K202300700022 1000. 227. 24. K202300700023 750. 136. 16. K202300700024 700. 118. 13. K202300700025 700. 121. 16. K202300700026 700. 152. 16. K202300700027 600. 121. 16. K202300700028 550. 132. 14. K202300700029 500. 90. 11. K202300700030 450. 101. 11. K202300700031 400. 76.4 8.6 K202300700032 320. 34.0 8.1 K202300700033 ENDDATA 15 0 K202300700034 ENDSUBENT 33 0 K202300799999 SUBENT K2023008 20070712 K002K202300800001 BIB 5 9 K202300800002 REACTION (16-S-0(G,X)4-BE-7,IND,SIG,,BRA) K202300800003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300800004 SAMPLE - Chemical-form of target is element. K202300800005 - Physical-form of target is solid. K202300800006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202300800007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300800008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300800009 not included in tabulated errors. K202300800010 (ERR-2) Uncertainty in detector efficiency K202300800011 ENDBIB 9 0 K202300800012 COMMON 1 3 K202300800013 ERR-2 K202300800014 PER-CENT K202300800015 7. K202300800016 ENDCOMMON 3 0 K202300800017 DATA 3 4 K202300800018 EN-MAX DATA ERR-T K202300800019 MEV MICRO-B MICRO-B K202300800020 1000. 160. 16. K202300800021 700. 109. 12. K202300800022 550. 99. 11. K202300800023 450. 73.0 8.2 K202300800024 ENDDATA 6 0 K202300800025 ENDSUBENT 24 0 K202300899999 SUBENT K2023009 20070712 K002K202300900001 BIB 5 11 K202300900002 REACTION (17-CL-0(G,X)4-BE-7,IND,SIG,,BRA) K202300900003 Measured with FeCl3 target (Contribution of Fe is K202300900004 subtracted.) K202300900005 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202300900006 SAMPLE - Chemical-form of target: FeCl3 K202300900007 - Physical-form of target is solid. K202300900008 - Target-thickness is 1000 mg/cm**2. Typical thickness K202300900009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202300900010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202300900011 not included in tabulated errors. K202300900012 (ERR-2) Uncertainty in detector efficiency K202300900013 ENDBIB 11 0 K202300900014 COMMON 1 3 K202300900015 ERR-2 K202300900016 PER-CENT K202300900017 7. K202300900018 ENDCOMMON 3 0 K202300900019 DATA 3 4 K202300900020 EN-MAX DATA ERR-T K202300900021 MEV MICRO-B MICRO-B K202300900022 1000. 113. 13. K202300900023 700. 82.3 9.9 K202300900024 550. 61.1 7.3 K202300900025 450. 51.1 7.1 K202300900026 ENDDATA 6 0 K202300900027 ENDSUBENT 26 0 K202300999999 SUBENT K2023010 20070712 K002K202301000001 BIB 5 9 K202301000002 REACTION (26-FE-0(G,X)4-BE-7,IND,SIG,,BRA) K202301000003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301000004 SAMPLE - Chemical-form of target is element. K202301000005 - Physical-form of target is solid. K202301000006 - Target-thickness is 900 mg/cm**2. Typical thickness K202301000007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301000008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301000009 not included in tabulated errors. K202301000010 (ERR-2) Uncertainty in detector efficiency K202301000011 ENDBIB 9 0 K202301000012 COMMON 1 3 K202301000013 ERR-2 K202301000014 PER-CENT K202301000015 7. K202301000016 ENDCOMMON 3 0 K202301000017 DATA 3 14 K202301000018 EN-MAX DATA ERR-T K202301000019 MEV MICRO-B MICRO-B K202301000020 1000. 72.4 9.5 K202301000021 1000. 74. 16. K202301000022 1000. 84.2 9.6 K202301000023 900. 67. 15. K202301000024 850. 43.4 6.2 K202301000025 850. 52.1 6.7 K202301000026 700. 37.5 9.5 K202301000027 700. 42.2 6.0 K202301000028 600. 19.3 6.1 K202301000029 550. 39. 14. K202301000030 550. 46.6 6.3 K202301000031 475. 18.9 6.8 K202301000032 450. 33.7 5.3 K202301000033 400. 21.1 6.0 K202301000034 ENDDATA 16 0 K202301000035 ENDSUBENT 34 0 K202301099999 SUBENT K2023011 20070712 K002K202301100001 BIB 6 10 K202301100002 REACTION (27-CO-59(G,X)4-BE-7,IND,SIG,,BRA) K202301100003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301100004 SAMPLE - Chemical-form of target is element. K202301100005 - Physical-form of target is solid. K202301100006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202301100007 METHOD (CHSEP) K202301100008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301100009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301100010 not included in tabulated errors. K202301100011 (ERR-2) Uncertainty in detector efficiency K202301100012 ENDBIB 10 0 K202301100013 COMMON 1 3 K202301100014 ERR-2 K202301100015 PER-CENT K202301100016 7. K202301100017 ENDCOMMON 3 0 K202301100018 DATA 3 5 K202301100019 EN-MAX DATA ERR-T K202301100020 MEV MICRO-B MICRO-B K202301100021 1000. 73.5 9.7 K202301100022 850. 57.2 8.6 K202301100023 600. 43.6 9.5 K202301100024 475. 33.7 8.5 K202301100025 400. 42. 12. K202301100026 ENDDATA 7 0 K202301100027 ENDSUBENT 26 0 K202301199999 SUBENT K2023012 20070712 K002K202301200001 BIB 6 11 K202301200002 REACTION (29-CU-0(G,X)4-BE-7,IND,SIG,,BRA) K202301200003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301200004 SAMPLE - Chemical-form of target is element. K202301200005 - Physical-form of target is solid. K202301200006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202301200007 thickness K202301200008 METHOD (CHSEP) Nondestructive measurement was also done K202301200009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301200010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301200011 not included in tabulated errors. K202301200012 (ERR-2) Uncertainty in detector efficiency K202301200013 ENDBIB 11 0 K202301200014 COMMON 1 3 K202301200015 ERR-2 K202301200016 PER-CENT K202301200017 7. K202301200018 ENDCOMMON 3 0 K202301200019 DATA 3 24 K202301200020 EN-MAX DATA ERR-T K202301200021 MEV MICRO-B MICRO-B K202301200022 1100. 69. 15. K202301200023 1000. 52.0 8.8 K202301200024 1000. 50.1 6.2 K202301200025 1000. 43. 19. K202301200026 900. 35.6 5.2 K202301200027 850. 43.1 5.8 K202301200028 800. 41.6 6.8 K202301200029 800. 47.0 6.0 K202301200030 700. 28.2 7.7 K202301200031 700. 41. 13. K202301200032 700. 37.5 9.0 K202301200033 600. 27.2 5.6 K202301200034 600. 32. 10. K202301200035 600. 28.7 6.9 K202301200036 600. 27. 11. K202301200037 550. 21.3 5.7 K202301200038 475. 31.2 5.9 K202301200039 475. 20.3 6.0 K202301200040 400. 14.8 4.4 K202301200041 400. 13.6 2.9 K202301200042 400. 12.1 2.4 K202301200043 315. 11.0 8.4 K202301200044 300. 10.9 6.0 K202301200045 250. 9.6 4.4 K202301200046 ENDDATA 26 0 K202301200047 ENDSUBENT 46 0 K202301299999 SUBENT K2023013 20070712 K002K202301300001 BIB 6 10 K202301300002 REACTION (39-Y-89(G,X)4-BE-7,IND,SIG,,BRA) K202301300003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301300004 SAMPLE - Chemical-form of target is element. K202301300005 - Physical-form of target is solid. K202301300006 - Target-thickness is 900 mg/cm**2. Typical thickness K202301300007 METHOD (CHSEP) K202301300008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301300009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301300010 not included in tabulated errors. K202301300011 (ERR-2) Uncertainty in detector efficiency K202301300012 ENDBIB 10 0 K202301300013 COMMON 1 3 K202301300014 ERR-2 K202301300015 PER-CENT K202301300016 7. K202301300017 ENDCOMMON 3 0 K202301300018 DATA 3 10 K202301300019 EN-MAX DATA ERR-T K202301300020 MEV MICRO-B MICRO-B K202301300021 1000. 46.9 5.4 K202301300022 950. 71. 10. K202301300023 900. 56.0 8.3 K202301300024 800. 49.1 5.7 K202301300025 700. 46.1 7.8 K202301300026 650. 32.8 5.0 K202301300027 550. 38.1 4.5 K202301300028 500. 33.8 5.0 K202301300029 450. 31.6 3.6 K202301300030 400. 23.8 3.5 K202301300031 ENDDATA 12 0 K202301300032 ENDSUBENT 31 0 K202301399999 SUBENT K2023014 20070712 K002K202301400001 BIB 6 10 K202301400002 REACTION (47-AG-0(G,X)4-BE-7,IND,SIG,,BRA) K202301400003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301400004 SAMPLE - Chemical-form of target is element. K202301400005 - Physical-form of target is solid. K202301400006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202301400007 METHOD (CHSEP) K202301400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301400010 not included in tabulated errors. K202301400011 (ERR-2) Uncertainty in detector efficiency K202301400012 ENDBIB 10 0 K202301400013 COMMON 1 3 K202301400014 ERR-2 K202301400015 PER-CENT K202301400016 7. K202301400017 ENDCOMMON 3 0 K202301400018 DATA 3 19 K202301400019 EN-MAX DATA ERR-T K202301400020 MEV MICRO-B MICRO-B K202301400021 1100. 29.3 3.1 K202301400022 1000. 37.4 4.0 K202301400023 1000. 34.3 3.6 K202301400024 950. 44.0 5.1 K202301400025 900. 29.4 3.5 K202301400026 850. 32.9 4.7 K202301400027 800. 27.9 3.5 K202301400028 700. 22.8 6.7 K202301400029 700. 20.9 2.6 K202301400030 700. 25.9 2.8 K202301400031 650. 17.7 2.9 K202301400032 600. 19.5 2.7 K202301400033 550. 16.4 2.3 K202301400034 475. 11.3 3.7 K202301400035 400. 13.1 2.6 K202301400036 400. 9.1 1.5 K202301400037 350. 2.5 2.1 K202301400038 325. 10.9 5.7 K202301400039 250. 3.9 3.0 K202301400040 ENDDATA 21 0 K202301400041 ENDSUBENT 40 0 K202301499999 SUBENT K2023015 20070712 K002K202301500001 BIB 6 10 K202301500002 REACTION (49-IN-0(G,X)4-BE-7,IND,SIG,,BRA) K202301500003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301500004 SAMPLE - Chemical-form of target is element. K202301500005 - Physical-form of target is solid. K202301500006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202301500007 METHOD (CHSEP) K202301500008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301500009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301500010 not included in tabulated errors. K202301500011 (ERR-2) Uncertainty in detector efficiency K202301500012 ENDBIB 10 0 K202301500013 COMMON 1 3 K202301500014 ERR-2 K202301500015 PER-CENT K202301500016 7. K202301500017 ENDCOMMON 3 0 K202301500018 DATA 3 8 K202301500019 EN-MAX DATA ERR-T K202301500020 MEV MICRO-B MICRO-B K202301500021 1000. 22.6 2.6 K202301500022 1000. 35.5 3.9 K202301500023 950. 32.9 3.9 K202301500024 900. 23.8 3.0 K202301500025 800. 20.0 2.5 K202301500026 700. 18.0 2.0 K202301500027 500. 8.3 1.1 K202301500028 400. 11.0 1.5 K202301500029 ENDDATA 10 0 K202301500030 ENDSUBENT 29 0 K202301599999 SUBENT K2023016 20070712 K002K202301600001 BIB 6 10 K202301600002 REACTION (59-PR-141(G,X)4-BE-7,IND,SIG,,BRA) K202301600003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301600004 SAMPLE - Chemical-form of target is element. K202301600005 - Physical-form of target is solid. K202301600006 - Target-thickness is 1400 mg/cm**2. Typical thickness K202301600007 METHOD (CHSEP) K202301600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301600010 not included in tabulated errors. K202301600011 (ERR-2) Uncertainty in detector efficiency K202301600012 ENDBIB 10 0 K202301600013 COMMON 1 3 K202301600014 ERR-2 K202301600015 PER-CENT K202301600016 7. K202301600017 ENDCOMMON 3 0 K202301600018 DATA 3 9 K202301600019 EN-MAX DATA ERR-T K202301600020 MEV MICRO-B MICRO-B K202301600021 1000. 24.5 3.7 K202301600022 950. 29.3 8.5 K202301600023 900. 17.5 3.5 K202301600024 800. 20.2 3.2 K202301600025 700. 22.4 5.5 K202301600026 650. 14.5 3.2 K202301600027 550. 19.5 2.3 K202301600028 500. 12.8 2.2 K202301600029 450. 15.1 2.2 K202301600030 ENDDATA 11 0 K202301600031 ENDSUBENT 30 0 K202301699999 SUBENT K2023017 20070712 K002K202301700001 BIB 6 10 K202301700002 REACTION (65-TB-159(G,X)4-BE-7,IND,SIG,,BRA) K202301700003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301700004 SAMPLE - Chemical-form of target is element. K202301700005 - Physical-form of target is solid. K202301700006 - Target-thickness is 1700 mg/cm**2. Typical thickness K202301700007 METHOD (CHSEP) K202301700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301700010 not included in tabulated errors. K202301700011 (ERR-2) Uncertainty in detector efficiency K202301700012 ENDBIB 10 0 K202301700013 COMMON 1 3 K202301700014 ERR-2 K202301700015 PER-CENT K202301700016 7. K202301700017 ENDCOMMON 3 0 K202301700018 DATA 3 5 K202301700019 EN-MAX DATA ERR-T K202301700020 MEV MICRO-B MICRO-B K202301700021 1000. 30.8 3.5 K202301700022 950. 36.0 5.7 K202301700023 700. 19.8 2.5 K202301700024 600. 18.9 2.6 K202301700025 500. 11.0 1.9 K202301700026 ENDDATA 7 0 K202301700027 ENDSUBENT 26 0 K202301799999 SUBENT K2023018 20070712 K002K202301800001 BIB 6 10 K202301800002 REACTION (67-HO-165(G,X)4-BE-7,IND,SIG,,BRA) K202301800003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301800004 SAMPLE - Chemical-form of target is element. K202301800005 - Physical-form of target is solid. K202301800006 - Target-thickness is 1900 mg/cm**2. Typical thickness K202301800007 METHOD (CHSEP) K202301800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301800010 not included in tabulated errors. K202301800011 (ERR-2) Uncertainty in detector efficiency K202301800012 ENDBIB 10 0 K202301800013 COMMON 1 3 K202301800014 ERR-2 K202301800015 PER-CENT K202301800016 7. K202301800017 ENDCOMMON 3 0 K202301800018 DATA 3 11 K202301800019 EN-MAX DATA ERR-T K202301800020 MEV MICRO-B MICRO-B K202301800021 1000. 27.8 3.3 K202301800022 950. 35. 12. K202301800023 900. 25.4 3.7 K202301800024 850. 29.4 4.4 K202301800025 800. 31.5 4.2 K202301800026 700. 24.5 5.2 K202301800027 650. 20.3 3.6 K202301800028 550. 33.9 3.8 K202301800029 500. 22.7 4.1 K202301800030 450. 30.5 3.4 K202301800031 400. 11.0 1.8 K202301800032 ENDDATA 13 0 K202301800033 ENDSUBENT 32 0 K202301899999 SUBENT K2023019 20070712 K002K202301900001 BIB 6 10 K202301900002 REACTION (79-AU-197(G,X)4-BE-7,IND,SIG,,BRA) K202301900003 DECAY-DATA (4-BE-7,53.29D,DG,477.6,0.1052) K202301900004 SAMPLE - Chemical-form of target is element. K202301900005 - Physical-form of target is solid. K202301900006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202301900007 METHOD (CHSEP) K202301900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202301900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202301900010 not included in tabulated errors. K202301900011 (ERR-2) Uncertainty in detector efficiency K202301900012 ENDBIB 10 0 K202301900013 COMMON 1 3 K202301900014 ERR-2 K202301900015 PER-CENT K202301900016 7. K202301900017 ENDCOMMON 3 0 K202301900018 DATA 3 9 K202301900019 EN-MAX DATA ERR-T K202301900020 MEV MICRO-B MICRO-B K202301900021 1100. 16.1 1.9 K202301900022 1000. 12.1 1.4 K202301900023 950. 12.3 1.8 K202301900024 900. 6.9 1.6 K202301900025 800. 8.0 1.8 K202301900026 700. 7.9 3.2 K202301900027 650. 8.6 2.5 K202301900028 550. 6.0 0.8 K202301900029 500. 4.9 0.7 K202301900030 ENDDATA 11 0 K202301900031 ENDSUBENT 30 0 K202301999999 SUBENT K2023020 20070712 K002K202302000001 BIB 6 14 K202302000002 REACTION (8-O-0(G,X)4-BE-10,IND,SIG,,BRA) K202302000003 PART-DET (4-BE-10) K202302000004 SAMPLE - Chemical-form of target: H2O K202302000005 - Physical-form of target is liquid. K202302000006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202302000007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302000008 at Research Center for Nuclear Science K202302000009 and Technology, Univ. of Tokyo K202302000010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302000011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302000012 not included in tabulated errors. K202302000013 (ERR-2) Uncertainty in amount of beryllium carrier K202302000014 added K202302000015 (ERR-3) Uncertainty in measurement of standard sample K202302000016 ENDBIB 14 0 K202302000017 COMMON 2 3 K202302000018 ERR-2 ERR-3 K202302000019 PER-CENT PER-CENT K202302000020 1. 3. K202302000021 ENDCOMMON 3 0 K202302000022 DATA 3 7 K202302000023 EN-MAX DATA ERR-T K202302000024 MEV MICRO-B MICRO-B K202302000025 1000. 89.3 8.8 K202302000026 850. 69.7 6.5 K202302000027 700. 56.0 6.3 K202302000028 600. 62.1 6.9 K202302000029 475. 49.0 5.0 K202302000030 400. 41.9 7.5 K202302000031 325. 33.8 4.9 K202302000032 ENDDATA 9 0 K202302000033 ENDSUBENT 32 0 K202302099999 SUBENT K2023021 20070712 K002K202302100001 BIB 6 14 K202302100002 REACTION (16-S-0(G,X)4-BE-10,IND,SIG,,BRA) K202302100003 PART-DET (4-BE-10) K202302100004 SAMPLE - Chemical-form of target is element. K202302100005 - Physical-form of target is solid. K202302100006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202302100007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302100008 at Research Center for Nuclear Science K202302100009 and Technology, Univ. of Tokyo K202302100010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302100011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302100012 not included in tabulated errors. K202302100013 (ERR-2) Uncertainty in amount of beryllium carrier K202302100014 added K202302100015 (ERR-3) Uncertainty in measurement of standard sample K202302100016 ENDBIB 14 0 K202302100017 COMMON 2 3 K202302100018 ERR-2 ERR-3 K202302100019 PER-CENT PER-CENT K202302100020 1. 3. K202302100021 ENDCOMMON 3 0 K202302100022 DATA 3 4 K202302100023 EN-MAX DATA ERR-T K202302100024 MEV MICRO-B MICRO-B K202302100025 1000. 19.2 1.5 K202302100026 700. 14.2 1.3 K202302100027 550. 9.5 0.9 K202302100028 450. 7.7 0.8 K202302100029 ENDDATA 6 0 K202302100030 ENDSUBENT 29 0 K202302199999 SUBENT K2023022 20070712 K002K202302200001 BIB 6 14 K202302200002 REACTION (26-FE-0(G,X)4-BE-10,IND,SIG,,BRA) K202302200003 PART-DET (4-BE-10) K202302200004 SAMPLE - Chemical-form of target is element. K202302200005 - Physical-form of target is solid. K202302200006 - Target-thickness is 900 mg/cm**2. Typical thickness K202302200007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302200008 at Research Center for Nuclear Science K202302200009 and Technology, Univ. of Tokyo K202302200010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302200011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302200012 not included in tabulated errors. K202302200013 (ERR-2) Uncertainty in amount of beryllium carrier K202302200014 added K202302200015 (ERR-3) Uncertainty in measurement of standard sample K202302200016 ENDBIB 14 0 K202302200017 COMMON 2 3 K202302200018 ERR-2 ERR-3 K202302200019 PER-CENT PER-CENT K202302200020 1. 3. K202302200021 ENDCOMMON 3 0 K202302200022 DATA 3 10 K202302200023 EN-MAX DATA ERR-T K202302200024 MEV MICRO-B MICRO-B K202302200025 1000. 17. 2. K202302200026 900. 16. 2. K202302200027 850. 13. 1. K202302200028 850. 11.1 1.3 K202302200029 700. 10. 4. K202302200030 600. 7.4 2.4 K202302200031 550. 6.5 1.0 K202302200032 475. 6. 1. K202302200033 400. 5.9 2.1 K202302200034 350. 10. 6. K202302200035 ENDDATA 12 0 K202302200036 ENDSUBENT 35 0 K202302299999 SUBENT K2023023 20070712 K002K202302300001 BIB 6 14 K202302300002 REACTION (27-CO-59(G,X)4-BE-10,IND,SIG,,BRA) K202302300003 PART-DET (4-BE-10) K202302300004 SAMPLE - Chemical-form of target is element. K202302300005 - Physical-form of target is solid. K202302300006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202302300007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302300008 at Research Center for Nuclear Science K202302300009 and Technology, Univ. of Tokyo K202302300010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302300011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302300012 not included in tabulated errors. K202302300013 (ERR-2) Uncertainty in amount of beryllium carrier K202302300014 added K202302300015 (ERR-3) Uncertainty in measurement of standard sample K202302300016 ENDBIB 14 0 K202302300017 COMMON 2 3 K202302300018 ERR-2 ERR-3 K202302300019 PER-CENT PER-CENT K202302300020 1. 3. K202302300021 ENDCOMMON 3 0 K202302300022 DATA 3 1 K202302300023 EN-MAX DATA ERR-T K202302300024 MEV MICRO-B MICRO-B K202302300025 475. 7.5 1.2 K202302300026 ENDDATA 3 0 K202302300027 ENDSUBENT 26 0 K202302399999 SUBENT K2023024 20070712 K002K202302400001 BIB 6 15 K202302400002 REACTION (29-CU-0(G,X)4-BE-10,IND,SIG,,BRA) K202302400003 PART-DET (4-BE-10) K202302400004 SAMPLE - Chemical-form of target is element. K202302400005 - Physical-form of target is solid. K202302400006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202302400007 thickness K202302400008 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302400009 at Research Center for Nuclear Science K202302400010 and Technology, Univ. of Tokyo K202302400011 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302400012 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302400013 not included in tabulated errors. K202302400014 (ERR-2) Uncertainty in amount of beryllium carrier K202302400015 added K202302400016 (ERR-3) Uncertainty in measurement of standard sample K202302400017 ENDBIB 15 0 K202302400018 COMMON 2 3 K202302400019 ERR-2 ERR-3 K202302400020 PER-CENT PER-CENT K202302400021 1. 3. K202302400022 ENDCOMMON 3 0 K202302400023 DATA 3 9 K202302400024 EN-MAX DATA ERR-T K202302400025 MEV MICRO-B MICRO-B K202302400026 1000. 14.6 1.8 K202302400027 900. 16.0 1.5 K202302400028 850. 13.3 1.2 K202302400029 700. 10.7 1.3 K202302400030 600. 6.0 2.4 K202302400031 550. 6.8 2.7 K202302400032 475. 8.8 2.4 K202302400033 400. 5.2 2.9 K202302400034 325. 9.3 6.2 K202302400035 ENDDATA 11 0 K202302400036 ENDSUBENT 35 0 K202302499999 SUBENT K2023025 20070712 K002K202302500001 BIB 6 14 K202302500002 REACTION (39-Y-89(G,X)4-BE-10,IND,SIG,,BRA) K202302500003 PART-DET (4-BE-10) K202302500004 SAMPLE - Chemical-form of target is element. K202302500005 - Physical-form of target is solid. K202302500006 - Target-thickness is 900 mg/cm**2. Typical thickness K202302500007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302500008 at Research Center for Nuclear Science K202302500009 and Technology, Univ. of Tokyo K202302500010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302500011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302500012 not included in tabulated errors. K202302500013 (ERR-2) Uncertainty in amount of beryllium carrier K202302500014 added K202302500015 (ERR-3) Uncertainty in measurement of standard sample K202302500016 ENDBIB 14 0 K202302500017 COMMON 2 3 K202302500018 ERR-2 ERR-3 K202302500019 PER-CENT PER-CENT K202302500020 1. 3. K202302500021 ENDCOMMON 3 0 K202302500022 DATA 3 7 K202302500023 EN-MAX DATA ERR-T K202302500024 MEV MICRO-B MICRO-B K202302500025 1000. 24.3 2.7 K202302500026 900. 24. 3. K202302500027 800. 19.6 2.4 K202302500028 700. 18. 2. K202302500029 650. 15.5 1.5 K202302500030 500. 12.8 1.4 K202302500031 400. 14. 5. K202302500032 ENDDATA 9 0 K202302500033 ENDSUBENT 32 0 K202302599999 SUBENT K2023026 20070712 K002K202302600001 BIB 6 14 K202302600002 REACTION (47-AG-0(G,X)4-BE-10,IND,SIG,,BRA) K202302600003 PART-DET (4-BE-10) K202302600004 SAMPLE - Chemical-form of target is element. K202302600005 - Physical-form of target is solid. K202302600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202302600007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302600008 at Research Center for Nuclear Science K202302600009 and Technology, Univ. of Tokyo K202302600010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302600011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302600012 not included in tabulated errors. K202302600013 (ERR-2) Uncertainty in amount of beryllium carrier K202302600014 added K202302600015 (ERR-3) Uncertainty in measurement of standard sample K202302600016 ENDBIB 14 0 K202302600017 COMMON 2 3 K202302600018 ERR-2 ERR-3 K202302600019 PER-CENT PER-CENT K202302600020 1. 3. K202302600021 ENDCOMMON 3 0 K202302600022 DATA 3 12 K202302600023 EN-MAX DATA ERR-T K202302600024 MEV MICRO-B MICRO-B K202302600025 1100. 17.3 1.5 K202302600026 1000. 21.8 2.1 K202302600027 900. 24.0 2.5 K202302600028 850. 18.0 1.8 K202302600029 800. 15.8 1.5 K202302600030 700. 14.3 1.7 K202302600031 700. 12.1 1.5 K202302600032 650. 11.0 1.2 K202302600033 550. 11.2 1.5 K202302600034 475. 6.9 1.6 K202302600035 350. 2.2 0.7 K202302600036 325. 7.7 3.8 K202302600037 ENDDATA 14 0 K202302600038 ENDSUBENT 37 0 K202302699999 SUBENT K2023027 20070712 K002K202302700001 BIB 6 14 K202302700002 REACTION (49-IN-0(G,X)4-BE-10,IND,SIG,,BRA) K202302700003 PART-DET (4-BE-10) K202302700004 SAMPLE - Chemical-form of target is element. K202302700005 - Physical-form of target is solid. K202302700006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202302700007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302700008 at Research Center for Nuclear Science K202302700009 and Technology, Univ. of Tokyo K202302700010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302700011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302700012 not included in tabulated errors. K202302700013 (ERR-2) Uncertainty in amount of beryllium carrier K202302700014 added K202302700015 (ERR-3) Uncertainty in measurement of standard sample K202302700016 ENDBIB 14 0 K202302700017 COMMON 2 3 K202302700018 ERR-2 ERR-3 K202302700019 PER-CENT PER-CENT K202302700020 1. 3. K202302700021 ENDCOMMON 3 0 K202302700022 DATA 3 8 K202302700023 EN-MAX DATA ERR-T K202302700024 MEV MICRO-B MICRO-B K202302700025 1000. 24.1 2.2 K202302700026 1000. 27.8 2.6 K202302700027 950. 26.1 2.4 K202302700028 900. 24.1 2.1 K202302700029 800. 18.1 1.6 K202302700030 700. 14.0 1.2 K202302700031 500. 8.4 0.9 K202302700032 400. 3.8 2.4 K202302700033 ENDDATA 10 0 K202302700034 ENDSUBENT 33 0 K202302799999 SUBENT K2023028 20070712 K002K202302800001 BIB 6 14 K202302800002 REACTION (59-PR-141(G,X)4-BE-10,IND,SIG,,BRA) K202302800003 PART-DET (4-BE-10) K202302800004 SAMPLE - Chemical-form of target is element. K202302800005 - Physical-form of target is solid. K202302800006 - Target-thickness is 1400 mg/cm**2. Typical thickness K202302800007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302800008 at Research Center for Nuclear Science K202302800009 and Technology, Univ. of Tokyo K202302800010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302800011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302800012 not included in tabulated errors. K202302800013 (ERR-2) Uncertainty in amount of beryllium carrier K202302800014 added K202302800015 (ERR-3) Uncertainty in measurement of standard sample K202302800016 ENDBIB 14 0 K202302800017 COMMON 2 3 K202302800018 ERR-2 ERR-3 K202302800019 PER-CENT PER-CENT K202302800020 1. 3. K202302800021 ENDCOMMON 3 0 K202302800022 DATA 3 8 K202302800023 EN-MAX DATA ERR-T K202302800024 MEV MICRO-B MICRO-B K202302800025 1000. 28.6 3.2 K202302800026 900. 27.7 3.1 K202302800027 800. 20.0 1.8 K202302800028 700. 21. 3. K202302800029 650. 14.6 2.1 K202302800030 550. 14.6 1.5 K202302800031 500. 12.3 1.7 K202302800032 450. 17.5 2.6 K202302800033 ENDDATA 10 0 K202302800034 ENDSUBENT 33 0 K202302899999 SUBENT K2023029 20070712 K002K202302900001 BIB 6 14 K202302900002 REACTION (65-TB-159(G,X)4-BE-10,IND,SIG,,BRA) K202302900003 PART-DET (4-BE-10) K202302900004 SAMPLE - Chemical-form of target is element. K202302900005 - Physical-form of target is solid. K202302900006 - Target-thickness is 1700 mg/cm**2. Typical thickness K202302900007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202302900008 at Research Center for Nuclear Science K202302900009 and Technology, Univ. of Tokyo K202302900010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202302900011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202302900012 not included in tabulated errors. K202302900013 (ERR-2) Uncertainty in amount of beryllium carrier K202302900014 added K202302900015 (ERR-3) Uncertainty in measurement of standard sample K202302900016 ENDBIB 14 0 K202302900017 COMMON 2 3 K202302900018 ERR-2 ERR-3 K202302900019 PER-CENT PER-CENT K202302900020 1. 3. K202302900021 ENDCOMMON 3 0 K202302900022 DATA 3 4 K202302900023 EN-MAX DATA ERR-T K202302900024 MEV MICRO-B MICRO-B K202302900025 1000. 38.1 4.2 K202302900026 700. 19.0 2.9 K202302900027 600. 24.5 3.1 K202302900028 500. 13.1 1.9 K202302900029 ENDDATA 6 0 K202302900030 ENDSUBENT 29 0 K202302999999 SUBENT K2023030 20070712 K002K202303000001 BIB 6 14 K202303000002 REACTION (67-HO-165(G,X)4-BE-10,IND,SIG,,BRA) K202303000003 PART-DET (4-BE-10) K202303000004 SAMPLE - Chemical-form of target is element. K202303000005 - Physical-form of target is solid. K202303000006 - Target-thickness is 1900 mg/cm**2. Typical thickness K202303000007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202303000008 at Research Center for Nuclear Science K202303000009 and Technology, Univ. of Tokyo K202303000010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202303000011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303000012 not included in tabulated errors. K202303000013 (ERR-2) Uncertainty in amount of beryllium carrier K202303000014 added K202303000015 (ERR-3) Uncertainty in measurement of standard sample K202303000016 ENDBIB 14 0 K202303000017 COMMON 2 3 K202303000018 ERR-2 ERR-3 K202303000019 PER-CENT PER-CENT K202303000020 1. 3. K202303000021 ENDCOMMON 3 0 K202303000022 DATA 3 7 K202303000023 EN-MAX DATA ERR-T K202303000024 MEV MICRO-B MICRO-B K202303000025 1000. 44.4 4.4 K202303000026 900. 36.8 4.2 K202303000027 850. 27.2 2.7 K202303000028 800. 28.4 2.4 K202303000029 700. 27.3 4.1 K202303000030 650. 18.0 1.9 K202303000031 400. 17.0 3.5 K202303000032 ENDDATA 9 0 K202303000033 ENDSUBENT 32 0 K202303099999 SUBENT K2023031 20070712 K002K202303100001 BIB 6 14 K202303100002 REACTION (79-AU-197(G,X)4-BE-10,IND,SIG,,BRA) K202303100003 PART-DET (4-BE-10) K202303100004 SAMPLE - Chemical-form of target is element. K202303100005 - Physical-form of target is solid. K202303100006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202303100007 FACILITY (ACCEL,2JPNTOK) Used for accelerator mass spectrometry K202303100008 at Research Center for Nuclear Science K202303100009 and Technology, Univ. of Tokyo K202303100010 DETECTOR (SIBAR) Used in accelerator mass spectroscopy K202303100011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303100012 not included in tabulated errors. K202303100013 (ERR-2) Uncertainty in amount of beryllium carrier K202303100014 added K202303100015 (ERR-3) Uncertainty in measurement of standard sample K202303100016 ENDBIB 14 0 K202303100017 COMMON 2 3 K202303100018 ERR-2 ERR-3 K202303100019 PER-CENT PER-CENT K202303100020 1. 3. K202303100021 ENDCOMMON 3 0 K202303100022 DATA 3 9 K202303100023 EN-MAX DATA ERR-T K202303100024 MEV MICRO-B MICRO-B K202303100025 1100. 40.3 3.5 K202303100026 950. 21.3 2.2 K202303100027 900. 28.4 3.2 K202303100028 800. 23.1 2.0 K202303100029 700. 25.1 3.8 K202303100030 650. 15.0 1.5 K202303100031 550. 13.6 1.6 K202303100032 500. 17.2 1.5 K202303100033 400. 7.9 4.8 K202303100034 ENDDATA 11 0 K202303100035 ENDSUBENT 34 0 K202303199999 SUBENT K2023032 20070712 K002K202303200001 BIB 6 12 K202303200002 REACTION (11-NA-23(G,X)11-NA-22,CUM,SIG,,BRA) K202303200003 Measured with NaCl target (Contribution of Cl is K202303200004 subtracted.) K202303200005 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303200006 SAMPLE - Chemical-form of target: NaCl K202303200007 - Physical-form of target is solid. K202303200008 - Target-thickness is 1000 mg/cm**2. Typical thickness K202303200009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303200010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303200011 not included in tabulated errors. K202303200012 (ERR-2) Uncertainty in detector efficiency K202303200013 STATUS (COREL,K2023036) Contribution of Cl in target K202303200014 ENDBIB 12 0 K202303200015 COMMON 1 3 K202303200016 ERR-2 K202303200017 PER-CENT K202303200018 7. K202303200019 ENDCOMMON 3 0 K202303200020 DATA 3 4 K202303200021 EN-MAX DATA ERR-T K202303200022 MEV MICRO-B MICRO-B K202303200023 1000. 5430. 390. K202303200024 700. 4500. 320. K202303200025 550. 4210. 380. K202303200026 450. 5260. 380. K202303200027 ENDDATA 6 0 K202303200028 ENDSUBENT 27 0 K202303299999 SUBENT K2023033 20070712 K002K202303300001 BIB 5 9 K202303300002 REACTION (13-AL-27(G,X)11-NA-22,CUM,SIG,,BRA) K202303300003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303300004 SAMPLE - Chemical-form of target is element. K202303300005 - Physical-form of target is solid. K202303300006 - Target-thickness is 270 mg/cm**2. Typical thickness K202303300007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303300008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303300009 not included in tabulated errors. K202303300010 (ERR-2) Uncertainty in detector efficiency K202303300011 ENDBIB 9 0 K202303300012 COMMON 1 3 K202303300013 ERR-2 K202303300014 PER-CENT K202303300015 7. K202303300016 ENDCOMMON 3 0 K202303300017 DATA 3 23 K202303300018 EN-MAX DATA ERR-T K202303300019 MEV MICRO-B MICRO-B K202303300020 1000. 804. 65. K202303300021 1000. 837. 68. K202303300022 900. 707. 52. K202303300023 900. 655. 60. K202303300024 850. 697. 57. K202303300025 850. 717. 58. K202303300026 825. 730. 55. K202303300027 700. 844. 69. K202303300028 700. 734. 62. K202303300029 700. 600. 54. K202303300030 600. 778. 64. K202303300031 600. 725. 59. K202303300032 550. 571. 42. K202303300033 525. 687. 57. K202303300034 475. 596. 48. K202303300035 475. 596. 45. K202303300036 450. 548. 49. K202303300037 425. 612. 50. K202303300038 400. 691. 57. K202303300039 400. 679. 56. K202303300040 280. 406. 34. K202303300041 275. 427. 49. K202303300042 250. 366. 44. K202303300043 ENDDATA 25 0 K202303300044 ENDSUBENT 43 0 K202303399999 SUBENT K2023034 20070712 K002K202303400001 BIB 5 9 K202303400002 REACTION (14-SI-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303400003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303400004 SAMPLE - Chemical-form of target is element. K202303400005 - Physical-form of target is solid. K202303400006 - Target-thickness is 300 mg/cm**2. Typical thickness K202303400007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303400008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303400009 not included in tabulated errors. K202303400010 (ERR-2) Uncertainty in detector efficiency K202303400011 ENDBIB 9 0 K202303400012 COMMON 1 3 K202303400013 ERR-2 K202303400014 PER-CENT K202303400015 7. K202303400016 ENDCOMMON 3 0 K202303400017 DATA 3 13 K202303400018 EN-MAX DATA ERR-T K202303400019 MEV MICRO-B MICRO-B K202303400020 1000. 884. 76. K202303400021 1000. 992. 86. K202303400022 1000. 606. 46. K202303400023 750. 750. 140. K202303400024 700. 714. 79. K202303400025 700. 752. 98. K202303400026 600. 691. 67. K202303400027 550. 462. 36. K202303400028 500. 720. 150. K202303400029 450. 413. 33. K202303400030 400. 508. 48. K202303400031 320. 360. 30. K202303400032 250. 264. 60. K202303400033 ENDDATA 15 0 K202303400034 ENDSUBENT 33 0 K202303499999 SUBENT K2023035 20070712 K002K202303500001 BIB 5 9 K202303500002 REACTION (16-S-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303500003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303500004 SAMPLE - Chemical-form of target is element. K202303500005 - Physical-form of target is solid. K202303500006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202303500007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303500008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303500009 not included in tabulated errors. K202303500010 (ERR-2) Uncertainty in detector efficiency K202303500011 ENDBIB 9 0 K202303500012 COMMON 1 3 K202303500013 ERR-2 K202303500014 PER-CENT K202303500015 7. K202303500016 ENDCOMMON 3 0 K202303500017 DATA 3 4 K202303500018 EN-MAX DATA ERR-T K202303500019 MEV MICRO-B MICRO-B K202303500020 1000. 306. 23. K202303500021 700. 231. 18. K202303500022 550. 227. 17. K202303500023 450. 196. 16. K202303500024 ENDDATA 6 0 K202303500025 ENDSUBENT 24 0 K202303599999 SUBENT K2023036 20070712 K002K202303600001 BIB 5 14 K202303600002 REACTION 1(17-CL-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303600003 Measured with FeCl3 target (Contribution of Fe is K202303600004 subtracted.) K202303600005 2(17-CL-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303600006 Measured with CuCl2 target (Contribution of Cu is K202303600007 subtracted.) K202303600008 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303600009 SAMPLE - Chemical-form of target: FeCl3, CuCl2 K202303600010 - Physical-form of target is solid. K202303600011 - Target-thickness is 1000 mg/cm**2. Typical thickness K202303600012 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303600013 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303600014 not included in tabulated errors. K202303600015 (ERR-2) Uncertainty in detector efficiency K202303600016 ENDBIB 14 0 K202303600017 COMMON 1 3 K202303600018 ERR-2 K202303600019 PER-CENT K202303600020 7. K202303600021 ENDCOMMON 3 0 K202303600022 DATA 5 12 K202303600023 EN-MAX DATA 1ERR-T 1DATA 2ERR-T 2 K202303600024 MEV MICRO-B MICRO-B MICRO-B MICRO-B K202303600025 1000. 143. 11. 165. 13. K202303600026 900. 144. 16. K202303600027 800. 157. 20. K202303600028 700. 101. 8. K202303600029 600. 142. 17. K202303600030 550. 97. 8. 95. 12. K202303600031 500. 85. 9. K202303600032 450. 69. 6. K202303600033 400. 66. 8. K202303600034 365. 70. 11. K202303600035 315. 34. 14. K202303600036 250. 12.9 1.1 K202303600037 ENDDATA 14 0 K202303600038 ENDSUBENT 37 0 K202303699999 SUBENT K2023037 20070712 K002K202303700001 BIB 5 9 K202303700002 REACTION (20-CA-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303700003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303700004 SAMPLE - Chemical-form of target: CaCO3 K202303700005 - Physical-form of target is solid. K202303700006 - Target-thickness is 800 mg/cm**2. Typical thickness K202303700007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303700008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303700009 not included in tabulated errors. K202303700010 (ERR-2) Uncertainty in detector efficiency K202303700011 ENDBIB 9 0 K202303700012 COMMON 1 3 K202303700013 ERR-2 K202303700014 PER-CENT K202303700015 7. K202303700016 ENDCOMMON 3 0 K202303700017 DATA 3 8 K202303700018 EN-MAX DATA ERR-T K202303700019 MEV MICRO-B MICRO-B K202303700020 1200. 146. 17. K202303700021 950. 101. 10. K202303700022 950. 119. 16. K202303700023 900. 117. 12. K202303700024 750. 85. 29. K202303700025 750. 89. 18. K202303700026 650. 79. 9. K202303700027 550. 60. 11. K202303700028 ENDDATA 10 0 K202303700029 ENDSUBENT 28 0 K202303799999 SUBENT K2023038 20070712 K002K202303800001 BIB 5 9 K202303800002 REACTION (23-V-0(G,X)11-NA-22,CUM,SIG,,BRA) K202303800003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303800004 SAMPLE - Chemical-form of target: V2O5 K202303800005 - Physical-form of target is solid. K202303800006 - Target-thickness is 800 mg/cm**2. Typical thickness K202303800007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303800008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303800009 not included in tabulated errors. K202303800010 (ERR-2) Uncertainty in detector efficiency K202303800011 ENDBIB 9 0 K202303800012 COMMON 1 3 K202303800013 ERR-2 K202303800014 PER-CENT K202303800015 7. K202303800016 ENDCOMMON 3 0 K202303800017 DATA 3 2 K202303800018 EN-MAX DATA ERR-T K202303800019 MEV MICRO-B MICRO-B K202303800020 1000. 13.7 3.3 K202303800021 850. 11.3 4.3 K202303800022 ENDDATA 4 0 K202303800023 ENDSUBENT 22 0 K202303899999 SUBENT K2023039 20070712 K002K202303900001 BIB 5 9 K202303900002 REACTION (25-MN-55(G,X)11-NA-22,CUM,SIG,,BRA) K202303900003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202303900004 SAMPLE - Chemical-form of target: MnO K202303900005 - Physical-form of target is solid. K202303900006 - Target-thickness is 800 mg/cm**2. Typical thickness K202303900007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202303900008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202303900009 not included in tabulated errors. K202303900010 (ERR-2) Uncertainty in detector efficiency K202303900011 ENDBIB 9 0 K202303900012 COMMON 1 3 K202303900013 ERR-2 K202303900014 PER-CENT K202303900015 7. K202303900016 ENDCOMMON 3 0 K202303900017 DATA 3 5 K202303900018 EN-MAX DATA ERR-T K202303900019 MEV MICRO-B MICRO-B K202303900020 1000. 11.7 2.5 K202303900021 1000. 9.9 1.7 K202303900022 700. 5.7 1.0 K202303900023 600. 6.4 3.9 K202303900024 550. 1.58 0.52 K202303900025 ENDDATA 7 0 K202303900026 ENDSUBENT 25 0 K202303999999 SUBENT K2023040 20070712 K002K202304000001 BIB 5 9 K202304000002 REACTION (26-FE-0(G,X)11-NA-22,CUM,SIG,,BRA) K202304000003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304000004 SAMPLE - Chemical-form of target is element. K202304000005 - Physical-form of target is solid. K202304000006 - Target-thickness is 900 mg/cm**2. Typical thickness K202304000007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304000008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304000009 not included in tabulated errors. K202304000010 (ERR-2) Uncertainty in detector efficiency K202304000011 ENDBIB 9 0 K202304000012 COMMON 1 3 K202304000013 ERR-2 K202304000014 PER-CENT K202304000015 7. K202304000016 ENDCOMMON 3 0 K202304000017 DATA 3 8 K202304000018 EN-MAX DATA ERR-T K202304000019 MEV MICRO-B MICRO-B K202304000020 1000. 7.3 2.5 K202304000021 1000. 7.1 1.5 K202304000022 850. 6.5 1.6 K202304000023 850. 6.9 1.9 K202304000024 700. 2.8 1.1 K202304000025 600. 3.5 2.8 K202304000026 550. 3.2 0.7 K202304000027 450. 2.3 0.6 K202304000028 ENDDATA 10 0 K202304000029 ENDSUBENT 28 0 K202304099999 SUBENT K2023041 20070712 K002K202304100001 BIB 5 9 K202304100002 REACTION (27-CO-59(G,X)11-NA-22,CUM,SIG,,BRA) K202304100003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304100004 SAMPLE - Chemical-form of target is element. K202304100005 - Physical-form of target is solid. K202304100006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202304100007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304100008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304100009 not included in tabulated errors. K202304100010 (ERR-2) Uncertainty in detector efficiency K202304100011 ENDBIB 9 0 K202304100012 COMMON 1 3 K202304100013 ERR-2 K202304100014 PER-CENT K202304100015 7. K202304100016 ENDCOMMON 3 0 K202304100017 DATA 3 7 K202304100018 EN-MAX DATA ERR-T K202304100019 MEV MICRO-B MICRO-B K202304100020 1200. 8.8 2.6 K202304100021 1000. 8.6 0.7 K202304100022 1000. 11. 7. K202304100023 900. 7.9 1.7 K202304100024 850. 6.4 1.7 K202304100025 850. 3.4 1.9 K202304100026 825. 3.6 3.4 K202304100027 ENDDATA 9 0 K202304100028 ENDSUBENT 27 0 K202304199999 SUBENT K2023042 20070712 K002K202304200001 BIB 5 10 K202304200002 REACTION (29-CU-0(G,X)11-NA-22,CUM,SIG,,BRA) K202304200003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304200004 SAMPLE - Chemical-form of target is element. K202304200005 - Physical-form of target is solid. K202304200006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202304200007 thickness K202304200008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304200009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304200010 not included in tabulated errors. K202304200011 (ERR-2) Uncertainty in detector efficiency K202304200012 ENDBIB 10 0 K202304200013 COMMON 1 3 K202304200014 ERR-2 K202304200015 PER-CENT K202304200016 7. K202304200017 ENDCOMMON 3 0 K202304200018 DATA 3 3 K202304200019 EN-MAX DATA ERR-T K202304200020 MEV MICRO-B MICRO-B K202304200021 1000. 5.1 2.6 K202304200022 1000. 4.5 1.4 K202304200023 850. 1.6 1.3 K202304200024 ENDDATA 5 0 K202304200025 ENDSUBENT 24 0 K202304299999 SUBENT K2023043 20070712 K002K202304300001 BIB 6 10 K202304300002 REACTION (39-Y-89(G,X)11-NA-22,CUM,SIG,,BRA) K202304300003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304300004 SAMPLE - Chemical-form of target: Y2O3 K202304300005 - Physical-form of target is solid. K202304300006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202304300007 METHOD (CHSEP) K202304300008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304300009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304300010 not included in tabulated errors. K202304300011 (ERR-2) Uncertainty in detector efficiency K202304300012 ENDBIB 10 0 K202304300013 COMMON 1 3 K202304300014 ERR-2 K202304300015 PER-CENT K202304300016 7. K202304300017 ENDCOMMON 3 0 K202304300018 DATA 3 3 K202304300019 EN-MAX DATA ERR-T K202304300020 MEV MICRO-B MICRO-B K202304300021 1000. 1.28 0.33 K202304300022 900. 1.04 0.32 K202304300023 800. 0.52 0.17 K202304300024 ENDDATA 5 0 K202304300025 ENDSUBENT 24 0 K202304399999 SUBENT K2023044 20070712 K002K202304400001 BIB 6 10 K202304400002 REACTION (47-AG-0(G,X)11-NA-22,CUM,SIG,,BRA) K202304400003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304400004 SAMPLE - Chemical-form of target is element. K202304400005 - Physical-form of target is solid. K202304400006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202304400007 METHOD (CHSEP) K202304400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304400010 not included in tabulated errors. K202304400011 (ERR-2) Uncertainty in detector efficiency K202304400012 ENDBIB 10 0 K202304400013 COMMON 1 3 K202304400014 ERR-2 K202304400015 PER-CENT K202304400016 7. K202304400017 ENDCOMMON 3 0 K202304400018 DATA 3 2 K202304400019 EN-MAX DATA ERR-T K202304400020 MEV MICRO-B MICRO-B K202304400021 1000. 0.90 0.24 K202304400022 900. 0.58 0.17 K202304400023 ENDDATA 4 0 K202304400024 ENDSUBENT 23 0 K202304499999 SUBENT K2023045 20070712 K002K202304500001 BIB 6 10 K202304500002 REACTION (49-IN-0(G,X)11-NA-22,CUM,SIG,,BRA) K202304500003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304500004 SAMPLE - Chemical-form of target is element. K202304500005 - Physical-form of target is solid. K202304500006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202304500007 METHOD (CHSEP) K202304500008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304500009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304500010 not included in tabulated errors. K202304500011 (ERR-2) Uncertainty in detector efficiency K202304500012 ENDBIB 10 0 K202304500013 COMMON 1 3 K202304500014 ERR-2 K202304500015 PER-CENT K202304500016 7. K202304500017 ENDCOMMON 3 0 K202304500018 DATA 3 2 K202304500019 EN-MAX DATA ERR-T K202304500020 MEV MICRO-B MICRO-B K202304500021 1000. 0.53 0.18 K202304500022 1000. 0.29 0.10 K202304500023 ENDDATA 4 0 K202304500024 ENDSUBENT 23 0 K202304599999 SUBENT K2023046 20070712 K002K202304600001 BIB 6 10 K202304600002 REACTION (65-TB-159(G,X)11-NA-22,CUM,SIG,,BRA) K202304600003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304600004 SAMPLE - Chemical-form of target: Tb4O7 K202304600005 - Physical-form of target is solid. K202304600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202304600007 METHOD (CHSEP) K202304600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304600010 not included in tabulated errors. K202304600011 (ERR-2) Uncertainty in detector efficiency K202304600012 ENDBIB 10 0 K202304600013 COMMON 1 3 K202304600014 ERR-2 K202304600015 PER-CENT K202304600016 7. K202304600017 ENDCOMMON 3 0 K202304600018 DATA 3 1 K202304600019 EN-MAX DATA ERR-T K202304600020 MEV MICRO-B MICRO-B K202304600021 1000. 0.65 0.21 K202304600022 ENDDATA 3 0 K202304600023 ENDSUBENT 22 0 K202304699999 SUBENT K2023047 20070712 K002K202304700001 BIB 6 10 K202304700002 REACTION (67-HO-165(G,X)11-NA-22,CUM,SIG,,BRA) K202304700003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304700004 SAMPLE - Chemical-form of target: Ho2O3 K202304700005 - Physical-form of target is solid. K202304700006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202304700007 METHOD (CHSEP) K202304700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304700010 not included in tabulated errors. K202304700011 (ERR-2) Uncertainty in detector efficiency K202304700012 ENDBIB 10 0 K202304700013 COMMON 1 3 K202304700014 ERR-2 K202304700015 PER-CENT K202304700016 7. K202304700017 ENDCOMMON 3 0 K202304700018 DATA 3 1 K202304700019 EN-MAX DATA ERR-T K202304700020 MEV MICRO-B MICRO-B K202304700021 1000. 0.53 0.18 K202304700022 ENDDATA 3 0 K202304700023 ENDSUBENT 22 0 K202304799999 SUBENT K2023048 20070712 K002K202304800001 BIB 6 10 K202304800002 REACTION (79-AU-197(G,X)11-NA-22,CUM,SIG,,BRA) K202304800003 DECAY-DATA (11-NA-22,2.6019YR,DG,1274.5,0.99944) K202304800004 SAMPLE - Chemical-form of target is element. K202304800005 - Physical-form of target is solid. K202304800006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202304800007 METHOD (CHSEP) K202304800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304800010 not included in tabulated errors. K202304800011 (ERR-2) Uncertainty in detector efficiency K202304800012 ENDBIB 10 0 K202304800013 COMMON 1 3 K202304800014 ERR-2 K202304800015 PER-CENT K202304800016 7. K202304800017 ENDCOMMON 3 0 K202304800018 DATA 3 3 K202304800019 EN-MAX DATA ERR-T K202304800020 MEV MICRO-B MICRO-B K202304800021 1100. 0.37 0.11 K202304800022 1000. 0.38 0.13 K202304800023 900. 0.34 0.10 K202304800024 ENDDATA 5 0 K202304800025 ENDSUBENT 24 0 K202304899999 SUBENT K2023049 20070712 K002K202304900001 BIB 5 10 K202304900002 REACTION (14-SI-0(G,X)11-NA-24,CUM,SIG,,BRA) K202304900003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202304900004 DG,2754.0,0.99944) K202304900005 SAMPLE - Chemical-form of target is element. K202304900006 - Physical-form of target is solid. K202304900007 - Target-thickness is 300 mg/cm**2. Typical thickness K202304900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202304900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202304900010 not included in tabulated errors. K202304900011 (ERR-2) Uncertainty in detector efficiency K202304900012 ENDBIB 10 0 K202304900013 COMMON 1 3 K202304900014 ERR-2 K202304900015 PER-CENT K202304900016 7. K202304900017 ENDCOMMON 3 0 K202304900018 DATA 3 26 K202304900019 EN-MAX DATA ERR-T K202304900020 MEV MICRO-B MICRO-B K202304900021 1000. 277. 28. K202304900022 1000. 280. 29. K202304900023 1000. 291. 30. K202304900024 900. 265. 28. K202304900025 900. 294. 30. K202304900026 850. 286. 33. K202304900027 700. 237. 25. K202304900028 700. 236. 26. K202304900029 700. 236. 24. K202304900030 650. 233. 32. K202304900031 650. 285. 49. K202304900032 600. 231. 24. K202304900033 550. 239. 24. K202304900034 500. 225. 24. K202304900035 450. 213. 25. K202304900036 450. 207. 21. K202304900037 450. 208. 22. K202304900038 450. 171. 18. K202304900039 400. 176. 18. K202304900040 320. 152. 17. K202304900041 320. 159. 19. K202304900042 320. 146. 16. K202304900043 320. 142. 24. K202304900044 250. 120. 23. K202304900045 250. 110. 16. K202304900046 250. 109. 16. K202304900047 ENDDATA 28 0 K202304900048 ENDSUBENT 47 0 K202304999999 SUBENT K2023050 20070712 K002K202305000001 BIB 5 10 K202305000002 REACTION (16-S-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305000003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305000004 DG,2754.0,0.99944) K202305000005 SAMPLE - Chemical-form of target is element. K202305000006 - Physical-form of target is solid. K202305000007 - Target-thickness is 1000 mg/cm**2. Typical thickness K202305000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305000010 not included in tabulated errors. K202305000011 (ERR-2) Uncertainty in detector efficiency K202305000012 ENDBIB 10 0 K202305000013 COMMON 1 3 K202305000014 ERR-2 K202305000015 PER-CENT K202305000016 7. K202305000017 ENDCOMMON 3 0 K202305000018 DATA 3 4 K202305000019 EN-MAX DATA ERR-T K202305000020 MEV MICRO-B MICRO-B K202305000021 1000. 195. 20. K202305000022 700. 152. 15. K202305000023 550. 144. 15. K202305000024 450. 124. 13. K202305000025 ENDDATA 6 0 K202305000026 ENDSUBENT 25 0 K202305099999 SUBENT K2023051 20070712 K002K202305100001 BIB 5 15 K202305100002 REACTION 1(17-CL-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305100003 Measured with FeCl3 and CuCl2 targets (Contribution of K202305100004 Fe and Cu is subtracted.) K202305100005 2(17-CL-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305100006 Measured with SrCl2 target (Contribution of Sr is K202305100007 assumed to be negligible.) K202305100008 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305100009 DG,2754.0,0.99944) K202305100010 SAMPLE - Chemical-form of target: FeCl3, CuCl2, SrCl2 K202305100011 - Physical-form of target is solid. K202305100012 - Target-thickness is 1000 mg/cm**2. Typical thickness K202305100013 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305100014 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305100015 not included in tabulated errors. K202305100016 (ERR-2) Uncertainty in detector efficiency K202305100017 ENDBIB 15 0 K202305100018 COMMON 1 3 K202305100019 ERR-2 K202305100020 PER-CENT K202305100021 7. K202305100022 ENDCOMMON 3 0 K202305100023 DATA 5 14 K202305100024 EN-MAX DATA 1ERR-T 1DATA 2ERR-T 2 K202305100025 MEV MICRO-B MICRO-B MICRO-B MICRO-B K202305100026 1000. 210. 21. K202305100027 1000. 241. 25. K202305100028 900. 194. 20. 185. 19. K202305100029 800. 223. 23. K202305100030 700. 163. 27. 189. 20. K202305100031 600. 180. 18. K202305100032 550. 152. 16. 178. 20. K202305100033 550. 125. 13. K202305100034 500. 153. 17. K202305100035 450. 121. 12. 123. 14. K202305100036 365.5 103. 11. K202305100037 315. 75. 9. K202305100038 275. 83. 11. 59.0 7.5 K202305100039 250. 20. 2. 40.5 7.0 K202305100040 ENDDATA 16 0 K202305100041 ENDSUBENT 40 0 K202305199999 SUBENT K2023052 20070712 K002K202305200001 BIB 5 10 K202305200002 REACTION (19-K-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305200003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305200004 DG,2754.0,0.99944) K202305200005 SAMPLE - Chemical-form of target: K2CO3 K202305200006 - Physical-form of target is solid. K202305200007 - Target-thickness is 800 mg/cm**2. Typical thickness K202305200008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305200009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305200010 not included in tabulated errors. K202305200011 (ERR-2) Uncertainty in detector efficiency K202305200012 ENDBIB 10 0 K202305200013 COMMON 1 3 K202305200014 ERR-2 K202305200015 PER-CENT K202305200016 7. K202305200017 ENDCOMMON 3 0 K202305200018 DATA 3 36 K202305200019 EN-MAX DATA ERR-T K202305200020 MEV MICRO-B MICRO-B K202305200021 1200. 100. 10. K202305200022 1200. 95.9 9.8 K202305200023 1000. 107. 11. K202305200024 1000. 113. 12. K202305200025 950. 91.8 9.4 K202305200026 950. 98. 10. K202305200027 900. 107. 11. K202305200028 825. 104. 11. K202305200029 750. 85.3 8.8 K202305200030 750. 90.2 9.3 K202305200031 750. 83.5 8.9 K202305200032 750. 90.7 9.4 K202305200033 700. 83.3 8.5 K202305200034 650. 88.2 9.0 K202305200035 550. 59.3 6.1 K202305200036 550. 59.3 6.1 K202305200037 525. 74.9 7.7 K202305200038 500. 53.4 5.5 K202305200039 450. 51.3 5.3 K202305200040 450. 50.5 5.9 K202305200041 425. 55.6 5.7 K202305200042 375. 32.5 3.4 K202305200043 375. 32.9 3.4 K202305200044 350. 25.7 3.3 K202305200045 350. 26.5 2.9 K202305200046 320. 23.4 2.9 K202305200047 320. 25.0 2.8 K202305200048 300. 21.3 2.2 K202305200049 280. 17.1 2.0 K202305200050 275. 12.9 1.4 K202305200051 275. 13.3 1.5 K202305200052 260. 12.8 1.4 K202305200053 250. 11. 2. K202305200054 250. 10.2 1.3 K202305200055 250. 9.6 1.3 K202305200056 250. 9.9 1.2 K202305200057 ENDDATA 38 0 K202305200058 ENDSUBENT 57 0 K202305299999 SUBENT K2023053 20070712 K002K202305300001 BIB 5 10 K202305300002 REACTION (20-CA-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305300003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305300004 DG,2754.0,0.99944) K202305300005 SAMPLE - Chemical-form of target: CaCO3 K202305300006 - Physical-form of target is solid. K202305300007 - Target-thickness is 800 mg/cm**2. Typical thickness K202305300008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305300009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305300010 not included in tabulated errors. K202305300011 (ERR-2) Uncertainty in detector efficiency K202305300012 ENDBIB 10 0 K202305300013 COMMON 1 3 K202305300014 ERR-2 K202305300015 PER-CENT K202305300016 7. K202305300017 ENDCOMMON 3 0 K202305300018 DATA 3 27 K202305300019 EN-MAX DATA ERR-T K202305300020 MEV MICRO-B MICRO-B K202305300021 1200. 117. 13. K202305300022 1000. 77.3 8.2 K202305300023 1000. 68.5 7.1 K202305300024 950. 70.8 7.5 K202305300025 950. 69.8 7.4 K202305300026 900. 62.5 6.4 K202305300027 825. 63.6 6.5 K202305300028 750. 56.9 6.0 K202305300029 750. 53.5 5.5 K202305300030 750. 58.5 6.4 K202305300031 750. 52.5 6.1 K202305300032 650. 47.0 5.1 K202305300033 550. 43.4 5.0 K202305300034 525. 41.7 4.3 K202305300035 450. 34.7 4.3 K202305300036 450. 29.5 3.3 K202305300037 425. 29.8 3.1 K202305300038 375. 16.0 1.7 K202305300039 375. 23.3 3.0 K202305300040 350. 11. 2. K202305300041 350. 27. 5. K202305300042 300. 8.4 1.7 K202305300043 280. 5.5 0.7 K202305300044 275. 8.5 1.4 K202305300045 260. 6.4 0.9 K202305300046 250. 7.1 1.9 K202305300047 250. 4.9 0.8 K202305300048 ENDDATA 29 0 K202305300049 ENDSUBENT 48 0 K202305399999 SUBENT K2023054 20070712 K002K202305400001 BIB 5 10 K202305400002 REACTION (23-V-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305400003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305400004 DG,2754.0,0.99944) K202305400005 SAMPLE - Chemical-form of target: V2O5 K202305400006 - Physical-form of target is solid. K202305400007 - Target-thickness is 800 mg/cm**2. Typical thickness K202305400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305400010 not included in tabulated errors. K202305400011 (ERR-2) Uncertainty in detector efficiency K202305400012 ENDBIB 10 0 K202305400013 COMMON 1 3 K202305400014 ERR-2 K202305400015 PER-CENT K202305400016 7. K202305400017 ENDCOMMON 3 0 K202305400018 DATA 3 6 K202305400019 EN-MAX DATA ERR-T K202305400020 MEV MICRO-B MICRO-B K202305400021 1000. 25.2 2.7 K202305400022 850. 21. 3. K202305400023 700. 15.0 2.3 K202305400024 600. 14.0 1.7 K202305400025 475. 9.4 1.5 K202305400026 400. 4.36 0.67 K202305400027 ENDDATA 8 0 K202305400028 ENDSUBENT 27 0 K202305499999 SUBENT K2023055 20070712 K002K202305500001 BIB 5 10 K202305500002 REACTION (25-MN-55(G,X)11-NA-24,CUM,SIG,,BRA) K202305500003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305500004 DG,2754.0,0.99944) K202305500005 SAMPLE - Chemical-form of target: MnO K202305500006 - Physical-form of target is solid. K202305500007 - Target-thickness is 800 mg/cm**2. Typical thickness K202305500008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305500009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305500010 not included in tabulated errors. K202305500011 (ERR-2) Uncertainty in detector efficiency K202305500012 ENDBIB 10 0 K202305500013 COMMON 1 3 K202305500014 ERR-2 K202305500015 PER-CENT K202305500016 7. K202305500017 ENDCOMMON 3 0 K202305500018 DATA 3 10 K202305500019 EN-MAX DATA ERR-T K202305500020 MEV MICRO-B MICRO-B K202305500021 1000. 20.9 2.7 K202305500022 1000. 21.1 2.2 K202305500023 900. 15.8 1.6 K202305500024 825. 15.0 1.6 K202305500025 700. 7.6 2.1 K202305500026 700. 10.4 1.1 K202305500027 600. 7.9 1.1 K202305500028 550. 6.99 0.72 K202305500029 525. 5.80 0.67 K202305500030 425. 4.2 0.6 K202305500031 ENDDATA 12 0 K202305500032 ENDSUBENT 31 0 K202305599999 SUBENT K2023056 20070712 K002K202305600001 BIB 5 10 K202305600002 REACTION (26-FE-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305600003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305600004 DG,2754.0,0.99944) K202305600005 SAMPLE - Chemical-form of target is element. K202305600006 - Physical-form of target is solid. K202305600007 - Target-thickness is 900 mg/cm**2. Typical thickness K202305600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305600010 not included in tabulated errors. K202305600011 (ERR-2) Uncertainty in detector efficiency K202305600012 ENDBIB 10 0 K202305600013 COMMON 1 3 K202305600014 ERR-2 K202305600015 PER-CENT K202305600016 7. K202305600017 ENDCOMMON 3 0 K202305600018 DATA 3 18 K202305600019 EN-MAX DATA ERR-T K202305600020 MEV MICRO-B MICRO-B K202305600021 1000. 13.5 1.4 K202305600022 1000. 16. 3. K202305600023 1000. 16.6 1.7 K202305600024 900. 13.6 1.5 K202305600025 850. 8.1 1.2 K202305600026 850. 11.1 1.6 K202305600027 700. 9.0 1.2 K202305600028 700. 14. 3. K202305600029 700. 8.18 0.85 K202305600030 600. 6.36 0.75 K202305600031 550. 6.4 0.8 K202305600032 550. 5.80 0.60 K202305600033 475. 4.0 0.6 K202305600034 450. 3.09 0.33 K202305600035 400. 2.54 0.40 K202305600036 350. 1.0 0.3 K202305600037 325. 1.0 0.4 K202305600038 250. 0.2 0.1 K202305600039 ENDDATA 20 0 K202305600040 ENDSUBENT 39 0 K202305699999 SUBENT K2023057 20070712 K002K202305700001 BIB 5 10 K202305700002 REACTION (27-CO-59(G,X)11-NA-24,CUM,SIG,,BRA) K202305700003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305700004 DG,2754.0,0.99944) K202305700005 SAMPLE - Chemical-form of target is element. K202305700006 - Physical-form of target is solid. K202305700007 - Target-thickness is 1000 mg/cm**2. Typical thickness K202305700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305700010 not included in tabulated errors. K202305700011 (ERR-2) Uncertainty in detector efficiency K202305700012 ENDBIB 10 0 K202305700013 COMMON 1 3 K202305700014 ERR-2 K202305700015 PER-CENT K202305700016 7. K202305700017 ENDCOMMON 3 0 K202305700018 DATA 3 13 K202305700019 EN-MAX DATA ERR-T K202305700020 MEV MICRO-B MICRO-B K202305700021 1000. 10.3 1.2 K202305700022 1000. 11.1 1.3 K202305700023 850. 8.21 0.96 K202305700024 800. 7.28 0.75 K202305700025 700. 6. 2. K202305700026 600. 3.5 0.5 K202305700027 600. 4.16 0.55 K202305700028 500. 4.35 0.79 K202305700029 475. 2.7 0.7 K202305700030 400. 1.8 0.4 K202305700031 400. 2.84 0.38 K202305700032 365.5 2.17 0.38 K202305700033 315. 2.54 0.46 K202305700034 ENDDATA 15 0 K202305700035 ENDSUBENT 34 0 K202305799999 SUBENT K2023058 20070712 K002K202305800001 BIB 5 10 K202305800002 REACTION (28-NI-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305800003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305800004 DG,2754.0,0.99944) K202305800005 SAMPLE - Chemical-form of target is element. K202305800006 - Physical-form of target is solid. K202305800007 - Target-thickness is 120 mg/cm**2. Typical thickness K202305800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305800010 not included in tabulated errors. K202305800011 (ERR-2) Uncertainty in detector efficiency K202305800012 ENDBIB 10 0 K202305800013 COMMON 1 3 K202305800014 ERR-2 K202305800015 PER-CENT K202305800016 7. K202305800017 ENDCOMMON 3 0 K202305800018 DATA 3 4 K202305800019 EN-MAX DATA ERR-T K202305800020 MEV MICRO-B MICRO-B K202305800021 1000. 10.6 1.5 K202305800022 700. 7.1 0.9 K202305800023 600. 5. 3. K202305800024 550. 4.6 0.8 K202305800025 ENDDATA 6 0 K202305800026 ENDSUBENT 25 0 K202305899999 SUBENT K2023059 20070712 K002K202305900001 BIB 5 11 K202305900002 REACTION (29-CU-0(G,X)11-NA-24,CUM,SIG,,BRA) K202305900003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202305900004 DG,2754.0,0.99944) K202305900005 SAMPLE - Chemical-form of target is element. K202305900006 - Physical-form of target is solid. K202305900007 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202305900008 thickness K202305900009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202305900010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202305900011 not included in tabulated errors. K202305900012 (ERR-2) Uncertainty in detector efficiency K202305900013 ENDBIB 11 0 K202305900014 COMMON 1 3 K202305900015 ERR-2 K202305900016 PER-CENT K202305900017 7. K202305900018 ENDCOMMON 3 0 K202305900019 DATA 3 28 K202305900020 EN-MAX DATA ERR-T K202305900021 MEV MICRO-B MICRO-B K202305900022 1200. 7.8 1.3 K202305900023 1000. 6.70 0.70 K202305900024 1000. 6.65 0.83 K202305900025 1000. 7.19 0.84 K202305900026 1000. 6.40 0.85 K202305900027 950. 6.34 0.91 K202305900028 900. 7.0 1.1 K202305900029 900. 5.0 0.7 K202305900030 850. 5.1 1.0 K202305900031 825. 5.51 0.67 K202305900032 825. 6.87 0.84 K202305900033 800. 5.8 1.3 K202305900034 750. 3.8 0.9 K202305900035 750. 5.3 1.1 K202305900036 700. 3.1 0.7 K202305900037 700. 3.32 0.46 K202305900038 650. 2.65 0.57 K202305900039 600. 1.86 0.27 K202305900040 600. 3.23 0.65 K202305900041 550. 2.12 0.26 K202305900042 550. 1.7 0.9 K202305900043 525. 1.7 0.3 K202305900044 525. 1.5 0.6 K202305900045 475. 1.6 0.4 K202305900046 425. 1.6 0.5 K202305900047 400. 0.77 0.16 K202305900048 350. 0.45 0.08 K202305900049 300. 0.18 0.08 K202305900050 ENDDATA 30 0 K202305900051 ENDSUBENT 50 0 K202305999999 SUBENT K2023060 20070712 K002K202306000001 BIB 6 11 K202306000002 REACTION (39-Y-89(G,X)11-NA-24,CUM,SIG,,BRA) K202306000003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306000004 DG,2754.0,0.99944) K202306000005 SAMPLE - Chemical-form of target: Y2O3 K202306000006 - Physical-form of target is solid. K202306000007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202306000008 METHOD (CHSEP) K202306000009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306000010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306000011 not included in tabulated errors. K202306000012 (ERR-2) Uncertainty in detector efficiency K202306000013 ENDBIB 11 0 K202306000014 COMMON 1 3 K202306000015 ERR-2 K202306000016 PER-CENT K202306000017 7. K202306000018 ENDCOMMON 3 0 K202306000019 DATA 3 7 K202306000020 EN-MAX DATA ERR-T K202306000021 MEV MICRO-B MICRO-B K202306000022 1000. 2.23 0.24 K202306000023 1000. 1.41 0.15 K202306000024 950. 1.3 0.2 K202306000025 900. 1.50 0.18 K202306000026 800. 1.1 0.2 K202306000027 550. 0.42 0.07 K202306000028 400. 0.15 0.03 K202306000029 ENDDATA 9 0 K202306000030 ENDSUBENT 29 0 K202306099999 SUBENT K2023061 20070712 K002K202306100001 BIB 6 11 K202306100002 REACTION (47-AG-0(G,X)11-NA-24,CUM,SIG,,BRA) K202306100003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306100004 DG,2754.0,0.99944) K202306100005 SAMPLE - Chemical-form of target is element. K202306100006 - Physical-form of target is solid. K202306100007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202306100008 METHOD (CHSEP) K202306100009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306100010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306100011 not included in tabulated errors. K202306100012 (ERR-2) Uncertainty in detector efficiency K202306100013 ENDBIB 11 0 K202306100014 COMMON 1 3 K202306100015 ERR-2 K202306100016 PER-CENT K202306100017 7. K202306100018 ENDCOMMON 3 0 K202306100019 DATA 3 14 K202306100020 EN-MAX DATA ERR-T K202306100021 MEV MICRO-B MICRO-B K202306100022 1100. 1.78 0.21 K202306100023 1000. 1.3 0.2 K202306100024 1000. 2.03 0.22 K202306100025 950. 1.8 0.2 K202306100026 900. 1.81 0.20 K202306100027 800. 1.8 0.3 K202306100028 700. 0.82 0.12 K202306100029 700. 0.57 0.07 K202306100030 650. 0.6 0.1 K202306100031 550. 0.56 0.09 K202306100032 400. 0.28 0.11 K202306100033 400. 0.22 0.04 K202306100034 350. 0.16 0.03 K202306100035 300. 0.09 0.04 K202306100036 ENDDATA 16 0 K202306100037 ENDSUBENT 36 0 K202306199999 SUBENT K2023062 20070712 K002K202306200001 BIB 6 11 K202306200002 REACTION (49-IN-0(G,X)11-NA-24,CUM,SIG,,BRA) K202306200003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306200004 DG,2754.0,0.99944) K202306200005 SAMPLE - Chemical-form of target is element. K202306200006 - Physical-form of target is solid. K202306200007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202306200008 METHOD (CHSEP) K202306200009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306200010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306200011 not included in tabulated errors. K202306200012 (ERR-2) Uncertainty in detector efficiency K202306200013 ENDBIB 11 0 K202306200014 COMMON 1 3 K202306200015 ERR-2 K202306200016 PER-CENT K202306200017 7. K202306200018 ENDCOMMON 3 0 K202306200019 DATA 3 8 K202306200020 EN-MAX DATA ERR-T K202306200021 MEV MICRO-B MICRO-B K202306200022 1000. 1.50 0.17 K202306200023 1000. 1.59 0.17 K202306200024 950. 1.55 0.16 K202306200025 900. 1.3 0.2 K202306200026 800. 0.87 0.13 K202306200027 700. 0.53 0.06 K202306200028 500. 0.30 0.04 K202306200029 400. 0.20 0.03 K202306200030 ENDDATA 10 0 K202306200031 ENDSUBENT 30 0 K202306299999 SUBENT K2023063 20070712 K002K202306300001 BIB 6 11 K202306300002 REACTION (65-TB-159(G,X)11-NA-24,CUM,SIG,,BRA) K202306300003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306300004 DG,2754.0,0.99944) K202306300005 SAMPLE - Chemical-form of target: Tb4O7 K202306300006 - Physical-form of target is solid. K202306300007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202306300008 METHOD (CHSEP) K202306300009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306300010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306300011 not included in tabulated errors. K202306300012 (ERR-2) Uncertainty in detector efficiency K202306300013 ENDBIB 11 0 K202306300014 COMMON 1 3 K202306300015 ERR-2 K202306300016 PER-CENT K202306300017 7. K202306300018 ENDCOMMON 3 0 K202306300019 DATA 3 5 K202306300020 EN-MAX DATA ERR-T K202306300021 MEV MICRO-B MICRO-B K202306300022 1000. 2.03 0.23 K202306300023 950. 2.2 0.3 K202306300024 900. 2.15 0.23 K202306300025 800. 1.3 0.2 K202306300026 550. 0.57 0.06 K202306300027 ENDDATA 7 0 K202306300028 ENDSUBENT 27 0 K202306399999 SUBENT K2023064 20070712 K002K202306400001 BIB 6 11 K202306400002 REACTION (67-HO-165(G,X)11-NA-24,CUM,SIG,,BRA) K202306400003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306400004 DG,2754.0,0.99944) K202306400005 SAMPLE - Chemical-form of target: Ho2O3 K202306400006 - Physical-form of target is solid. K202306400007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202306400008 METHOD (CHSEP) K202306400009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306400010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306400011 not included in tabulated errors. K202306400012 (ERR-2) Uncertainty in detector efficiency K202306400013 ENDBIB 11 0 K202306400014 COMMON 1 3 K202306400015 ERR-2 K202306400016 PER-CENT K202306400017 7. K202306400018 ENDCOMMON 3 0 K202306400019 DATA 3 9 K202306400020 EN-MAX DATA ERR-T K202306400021 MEV MICRO-B MICRO-B K202306400022 1000. 2.25 0.30 K202306400023 1000. 2.26 0.23 K202306400024 950. 2.3 0.3 K202306400025 900. 1.92 0.22 K202306400026 800. 1.3 0.2 K202306400027 700. 0.8 0.5 K202306400028 600. 0.87 0.21 K202306400029 600. 0.83 0.10 K202306400030 400. 0.25 0.05 K202306400031 ENDDATA 11 0 K202306400032 ENDSUBENT 31 0 K202306499999 SUBENT K2023065 20070712 K002K202306500001 BIB 6 11 K202306500002 REACTION (79-AU-197(G,X)11-NA-24,CUM,SIG,,BRA) K202306500003 DECAY-DATA (11-NA-24,14.959HR,DG,1368.6,1.00, K202306500004 DG,2754.0,0.99944) K202306500005 SAMPLE - Chemical-form of target is element. K202306500006 - Physical-form of target is solid. K202306500007 - Target-thickness is 3000 mg/cm**2. Typical thickness K202306500008 METHOD (CHSEP) K202306500009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306500010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306500011 not included in tabulated errors. K202306500012 (ERR-2) Uncertainty in detector efficiency K202306500013 ENDBIB 11 0 K202306500014 COMMON 1 3 K202306500015 ERR-2 K202306500016 PER-CENT K202306500017 7. K202306500018 ENDCOMMON 3 0 K202306500019 DATA 3 12 K202306500020 EN-MAX DATA ERR-T K202306500021 MEV MICRO-B MICRO-B K202306500022 1100. 2.55 0.27 K202306500023 1000. 1.98 0.22 K202306500024 1000. 2.1 0.3 K202306500025 950. 2.1 0.2 K202306500026 900. 2.05 0.22 K202306500027 800. 1.3 0.2 K202306500028 700. 1.31 0.17 K202306500029 650. 0.77 0.10 K202306500030 600. 0.82 0.23 K202306500031 550. 0.52 0.06 K202306500032 500. 0.48 0.07 K202306500033 400. 0.32 0.05 K202306500034 ENDDATA 14 0 K202306500035 ENDSUBENT 34 0 K202306599999 SUBENT K2023066 20070712 K002K202306600001 BIB 5 9 K202306600002 REACTION (14-SI-30(G,X)12-MG-28,CUM,SIG,,BRA) K202306600003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202306600004 SAMPLE - Chemical-form of target is element. K202306600005 - Physical-form of target is solid. K202306600006 - Target-thickness is 300 mg/cm**2. Typical thickness K202306600007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306600008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306600009 not included in tabulated errors. K202306600010 (ERR-2) Uncertainty in detector efficiency K202306600011 ENDBIB 9 0 K202306600012 COMMON 1 3 K202306600013 ERR-2 K202306600014 PER-CENT K202306600015 7. K202306600016 ENDCOMMON 3 0 K202306600017 DATA 3 7 K202306600018 EN-MAX DATA ERR-T K202306600019 MEV MICRO-B MICRO-B K202306600020 1000. 207. 23. K202306600021 1000. 171. 22. K202306600022 700. 172. 19. K202306600023 600. 168. 28. K202306600024 550. 169. 19. K202306600025 450. 147. 19. K202306600026 400. 122. 16. K202306600027 ENDDATA 9 0 K202306600028 ENDSUBENT 27 0 K202306699999 SUBENT K2023067 20070712 K002K202306700001 BIB 5 9 K202306700002 REACTION (16-S-0(G,X)12-MG-28,CUM,SIG,,BRA) K202306700003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202306700004 SAMPLE - Chemical-form of target is element. K202306700005 - Physical-form of target is solid. K202306700006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202306700007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306700008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306700009 not included in tabulated errors. K202306700010 (ERR-2) Uncertainty in detector efficiency K202306700011 ENDBIB 9 0 K202306700012 COMMON 1 3 K202306700013 ERR-2 K202306700014 PER-CENT K202306700015 7. K202306700016 ENDCOMMON 3 0 K202306700017 DATA 3 4 K202306700018 EN-MAX DATA ERR-T K202306700019 MEV MICRO-B MICRO-B K202306700020 1000. 5.33 0.57 K202306700021 700. 4.41 0.48 K202306700022 550. 4.37 0.51 K202306700023 450. 3.34 0.43 K202306700024 ENDDATA 6 0 K202306700025 ENDSUBENT 24 0 K202306799999 SUBENT K2023068 20070712 K002K202306800001 BIB 5 9 K202306800002 REACTION (17-CL-0(G,X)12-MG-28,CUM,SIG,,BRA) K202306800003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202306800004 SAMPLE - Chemical-form of target: NaCl K202306800005 - Physical-form of target is solid. K202306800006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202306800007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306800008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306800009 not included in tabulated errors. K202306800010 (ERR-2) Uncertainty in detector efficiency K202306800011 ENDBIB 9 0 K202306800012 COMMON 1 3 K202306800013 ERR-2 K202306800014 PER-CENT K202306800015 7. K202306800016 ENDCOMMON 3 0 K202306800017 DATA 3 4 K202306800018 EN-MAX DATA ERR-T K202306800019 MEV MICRO-B MICRO-B K202306800020 1000. 21.1 2.2 K202306800021 700. 15.6 1.6 K202306800022 550. 15.9 1.7 K202306800023 450. 12.7 1.4 K202306800024 ENDDATA 6 0 K202306800025 ENDSUBENT 24 0 K202306899999 SUBENT K2023069 20070712 K002K202306900001 BIB 5 9 K202306900002 REACTION (19-K-0(G,X)12-MG-28,CUM,SIG,,BRA) K202306900003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202306900004 SAMPLE - Chemical-form of target: K2CO3 K202306900005 - Physical-form of target is solid. K202306900006 - Target-thickness is 800 mg/cm**2. Typical thickness K202306900007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202306900008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202306900009 not included in tabulated errors. K202306900010 (ERR-2) Uncertainty in detector efficiency K202306900011 ENDBIB 9 0 K202306900012 COMMON 1 3 K202306900013 ERR-2 K202306900014 PER-CENT K202306900015 7. K202306900016 ENDCOMMON 3 0 K202306900017 DATA 3 33 K202306900018 EN-MAX DATA ERR-T K202306900019 MEV MICRO-B MICRO-B K202306900020 1200. 8.83 0.95 K202306900021 1200. 8.87 0.96 K202306900022 1000. 7.77 0.84 K202306900023 1000. 8.7 1.1 K202306900024 950. 6.22 0.78 K202306900025 950. 5.94 0.80 K202306900026 900. 7.47 0.84 K202306900027 825. 7.99 0.83 K202306900028 750. 6.17 0.84 K202306900029 750. 7.06 0.84 K202306900030 750. 6.6 0.9 K202306900031 750. 7.12 0.78 K202306900032 700. 6.66 0.76 K202306900033 650. 5.90 0.77 K202306900034 550. 4.80 0.63 K202306900035 550. 5.41 0.66 K202306900036 525. 6.06 0.70 K202306900037 500. 3.48 0.58 K202306900038 450. 4.00 0.61 K202306900039 450. 4.6 0.9 K202306900040 425. 4.5 0.6 K202306900041 375. 3.4 0.5 K202306900042 375. 3.0 0.6 K202306900043 350. 3.0 0.7 K202306900044 320. 2.4 0.7 K202306900045 300. 2.0 0.4 K202306900046 280. 1.7 0.3 K202306900047 275. 1.8 0.5 K202306900048 275. 1.6 0.7 K202306900049 260. 1.1 0.3 K202306900050 250. 2.1 0.8 K202306900051 250. 0.9 0.5 K202306900052 250. 1.4 0.8 K202306900053 ENDDATA 35 0 K202306900054 ENDSUBENT 53 0 K202306999999 SUBENT K2023070 20070712 K002K202307000001 BIB 5 9 K202307000002 REACTION (20-CA-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307000003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307000004 SAMPLE - Chemical-form of target: CaCO3 K202307000005 - Physical-form of target is solid. K202307000006 - Target-thickness is 800 mg/cm**2. Typical thickness K202307000007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307000008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307000009 not included in tabulated errors. K202307000010 (ERR-2) Uncertainty in detector efficiency K202307000011 ENDBIB 9 0 K202307000012 COMMON 1 3 K202307000013 ERR-2 K202307000014 PER-CENT K202307000015 7. K202307000016 ENDCOMMON 3 0 K202307000017 DATA 3 19 K202307000018 EN-MAX DATA ERR-T K202307000019 MEV MICRO-B MICRO-B K202307000020 1200. 3.69 0.46 K202307000021 1000. 2.6 0.5 K202307000022 950. 4.5 1.0 K202307000023 950. 3.6 0.8 K202307000024 900. 3.41 0.55 K202307000025 825. 3.12 0.37 K202307000026 750. 2.9 0.4 K202307000027 750. 2.8 0.6 K202307000028 750. 4. 2. K202307000029 750. 5.0 1.3 K202307000030 650. 2.6 0.7 K202307000031 550. 1.9 0.4 K202307000032 525. 2.2 0.4 K202307000033 450. 1.4 0.6 K202307000034 450. 1.9 0.9 K202307000035 425. 1.8 0.3 K202307000036 375. 1.5 0.7 K202307000037 375. 1.9 0.4 K202307000038 300. 2.2 0.9 K202307000039 ENDDATA 21 0 K202307000040 ENDSUBENT 39 0 K202307099999 SUBENT K2023071 20070712 K002K202307100001 BIB 5 9 K202307100002 REACTION (23-V-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307100003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307100004 SAMPLE - Chemical-form of target: V2O5 K202307100005 - Physical-form of target is solid. K202307100006 - Target-thickness is 800 mg/cm**2. Typical thickness K202307100007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307100008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307100009 not included in tabulated errors. K202307100010 (ERR-2) Uncertainty in detector efficiency K202307100011 ENDBIB 9 0 K202307100012 COMMON 1 3 K202307100013 ERR-2 K202307100014 PER-CENT K202307100015 7. K202307100016 ENDCOMMON 3 0 K202307100017 DATA 3 2 K202307100018 EN-MAX DATA ERR-T K202307100019 MEV MICRO-B MICRO-B K202307100020 1000. 8.5 1.6 K202307100021 600. 3.4 0.7 K202307100022 ENDDATA 4 0 K202307100023 ENDSUBENT 22 0 K202307199999 SUBENT K2023072 20070712 K002K202307200001 BIB 5 9 K202307200002 REACTION (25-MN-55(G,X)12-MG-28,CUM,SIG,,BRA) K202307200003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307200004 SAMPLE - Chemical-form of target: MnO K202307200005 - Physical-form of target is solid. K202307200006 - Target-thickness is 800 mg/cm**2. Typical thickness K202307200007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307200008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307200009 not included in tabulated errors. K202307200010 (ERR-2) Uncertainty in detector efficiency K202307200011 ENDBIB 9 0 K202307200012 COMMON 1 3 K202307200013 ERR-2 K202307200014 PER-CENT K202307200015 7. K202307200016 ENDCOMMON 3 0 K202307200017 DATA 3 5 K202307200018 EN-MAX DATA ERR-T K202307200019 MEV MICRO-B MICRO-B K202307200020 1000. 3.69 0.50 K202307200021 1000. 4.7 0.9 K202307200022 700. 2.01 0.23 K202307200023 600. 1.6 0.6 K202307200024 550. 1.68 0.21 K202307200025 ENDDATA 7 0 K202307200026 ENDSUBENT 25 0 K202307299999 SUBENT K2023073 20070712 K002K202307300001 BIB 5 9 K202307300002 REACTION (26-FE-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307300003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307300004 SAMPLE - Chemical-form of target is element. K202307300005 - Physical-form of target is solid. K202307300006 - Target-thickness is 900 mg/cm**2. Typical thickness K202307300007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307300008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307300009 not included in tabulated errors. K202307300010 (ERR-2) Uncertainty in detector efficiency K202307300011 ENDBIB 9 0 K202307300012 COMMON 1 3 K202307300013 ERR-2 K202307300014 PER-CENT K202307300015 7. K202307300016 ENDCOMMON 3 0 K202307300017 DATA 3 4 K202307300018 EN-MAX DATA ERR-T K202307300019 MEV MICRO-B MICRO-B K202307300020 1000. 2.19 0.27 K202307300021 700. 1.43 0.20 K202307300022 550. 0.78 0.14 K202307300023 450. 0.47 0.11 K202307300024 ENDDATA 6 0 K202307300025 ENDSUBENT 24 0 K202307399999 SUBENT K2023074 20070712 K002K202307400001 BIB 5 9 K202307400002 REACTION (27-CO-59(G,X)12-MG-28,CUM,SIG,,BRA) K202307400003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307400004 SAMPLE - Chemical-form of target is element. K202307400005 - Physical-form of target is solid. K202307400006 - Target-thickness is 1000 mg/cm**2. Typical thickness K202307400007 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307400008 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307400009 not included in tabulated errors. K202307400010 (ERR-2) Uncertainty in detector efficiency K202307400011 ENDBIB 9 0 K202307400012 COMMON 1 3 K202307400013 ERR-2 K202307400014 PER-CENT K202307400015 7. K202307400016 ENDCOMMON 3 0 K202307400017 DATA 3 2 K202307400018 EN-MAX DATA ERR-T K202307400019 MEV MICRO-B MICRO-B K202307400020 1000. 2.3 0.6 K202307400021 600. 1.3 0.3 K202307400022 ENDDATA 4 0 K202307400023 ENDSUBENT 22 0 K202307499999 SUBENT K2023075 20070712 K002K202307500001 BIB 6 11 K202307500002 REACTION (29-CU-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307500003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307500004 SAMPLE - Chemical-form of target is element. K202307500005 - Physical-form of target is solid. K202307500006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202307500007 thickness K202307500008 METHOD (CHSEP) K202307500009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307500010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307500011 not included in tabulated errors. K202307500012 (ERR-2) Uncertainty in detector efficiency K202307500013 ENDBIB 11 0 K202307500014 COMMON 1 3 K202307500015 ERR-2 K202307500016 PER-CENT K202307500017 7. K202307500018 ENDCOMMON 3 0 K202307500019 DATA 3 4 K202307500020 EN-MAX DATA ERR-T K202307500021 MEV MICRO-B MICRO-B K202307500022 1000. 1.08 0.14 K202307500023 950. 1.07 0.15 K202307500024 700. 0.42 0.07 K202307500025 550. 0.27 0.06 K202307500026 ENDDATA 6 0 K202307500027 ENDSUBENT 26 0 K202307599999 SUBENT K2023076 20070712 K002K202307600001 BIB 6 10 K202307600002 REACTION (39-Y-89(G,X)12-MG-28,CUM,SIG,,BRA) K202307600003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307600004 SAMPLE - Chemical-form of target: Y2O3 K202307600005 - Physical-form of target is solid. K202307600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202307600007 METHOD (CHSEP) K202307600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307600010 not included in tabulated errors. K202307600011 (ERR-2) Uncertainty in detector efficiency K202307600012 ENDBIB 10 0 K202307600013 COMMON 1 3 K202307600014 ERR-2 K202307600015 PER-CENT K202307600016 7. K202307600017 ENDCOMMON 3 0 K202307600018 DATA 3 2 K202307600019 EN-MAX DATA ERR-T K202307600020 MEV MICRO-B MICRO-B K202307600021 1000. 0.22 0.03 K202307600022 950. 0.24 0.05 K202307600023 ENDDATA 4 0 K202307600024 ENDSUBENT 23 0 K202307699999 SUBENT K2023077 20070712 K002K202307700001 BIB 6 10 K202307700002 REACTION (47-AG-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307700003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307700004 SAMPLE - Chemical-form of target is element. K202307700005 - Physical-form of target is solid. K202307700006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202307700007 METHOD (CHSEP) K202307700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307700010 not included in tabulated errors. K202307700011 (ERR-2) Uncertainty in detector efficiency K202307700012 ENDBIB 10 0 K202307700013 COMMON 1 3 K202307700014 ERR-2 K202307700015 PER-CENT K202307700016 7. K202307700017 ENDCOMMON 3 0 K202307700018 DATA 3 3 K202307700019 EN-MAX DATA ERR-T K202307700020 MEV MICRO-B MICRO-B K202307700021 1100. 0.22 0.03 K202307700022 950. 0.27 0.04 K202307700023 700. 0.088 0.013 K202307700024 ENDDATA 5 0 K202307700025 ENDSUBENT 24 0 K202307799999 SUBENT K2023078 20070712 K002K202307800001 BIB 6 10 K202307800002 REACTION (49-IN-0(G,X)12-MG-28,CUM,SIG,,BRA) K202307800003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307800004 SAMPLE - Chemical-form of target is element. K202307800005 - Physical-form of target is solid. K202307800006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202307800007 METHOD (CHSEP) K202307800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307800010 not included in tabulated errors. K202307800011 (ERR-2) Uncertainty in detector efficiency K202307800012 ENDBIB 10 0 K202307800013 COMMON 1 3 K202307800014 ERR-2 K202307800015 PER-CENT K202307800016 7. K202307800017 ENDCOMMON 3 0 K202307800018 DATA 3 3 K202307800019 EN-MAX DATA ERR-T K202307800020 MEV MICRO-B MICRO-B K202307800021 1000. 0.29 0.03 K202307800022 950. 0.19 0.04 K202307800023 700. 0.097 0.016 K202307800024 ENDDATA 5 0 K202307800025 ENDSUBENT 24 0 K202307899999 SUBENT K2023079 20070712 K002K202307900001 BIB 6 10 K202307900002 REACTION (65-TB-159(G,X)12-MG-28,CUM,SIG,,BRA) K202307900003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202307900004 SAMPLE - Chemical-form of target: Tb4O7 K202307900005 - Physical-form of target is solid. K202307900006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202307900007 METHOD (CHSEP) K202307900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202307900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202307900010 not included in tabulated errors. K202307900011 (ERR-2) Uncertainty in detector efficiency K202307900012 ENDBIB 10 0 K202307900013 COMMON 1 3 K202307900014 ERR-2 K202307900015 PER-CENT K202307900016 7. K202307900017 ENDCOMMON 3 0 K202307900018 DATA 3 2 K202307900019 EN-MAX DATA ERR-T K202307900020 MEV MICRO-B MICRO-B K202307900021 950. 0.82 0.12 K202307900022 550. 0.22 0.03 K202307900023 ENDDATA 4 0 K202307900024 ENDSUBENT 23 0 K202307999999 SUBENT K2023080 20070712 K002K202308000001 BIB 6 10 K202308000002 REACTION (67-HO-165(G,X)12-MG-28,CUM,SIG,,BRA) K202308000003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202308000004 SAMPLE - Chemical-form of target: Ho2O3 K202308000005 - Physical-form of target is solid. K202308000006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202308000007 METHOD (CHSEP) K202308000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308000010 not included in tabulated errors. K202308000011 (ERR-2) Uncertainty in detector efficiency K202308000012 ENDBIB 10 0 K202308000013 COMMON 1 3 K202308000014 ERR-2 K202308000015 PER-CENT K202308000016 7. K202308000017 ENDCOMMON 3 0 K202308000018 DATA 3 4 K202308000019 EN-MAX DATA ERR-T K202308000020 MEV MICRO-B MICRO-B K202308000021 1000. 0.85 0.09 K202308000022 950. 0.87 0.11 K202308000023 600. 0.30 0.04 K202308000024 400. 0.098 0.035 K202308000025 ENDDATA 6 0 K202308000026 ENDSUBENT 25 0 K202308099999 SUBENT K2023081 20070712 K002K202308100001 BIB 6 10 K202308100002 REACTION (79-AU-197(G,X)12-MG-28,CUM,SIG,,BRA) K202308100003 DECAY-DATA (12-MG-28,20.91HR,DG,1778.9,1.00) K202308100004 SAMPLE - Chemical-form of target is element. K202308100005 - Physical-form of target is solid. K202308100006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202308100007 METHOD (CHSEP) K202308100008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308100009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308100010 not included in tabulated errors. K202308100011 (ERR-2) Uncertainty in detector efficiency K202308100012 ENDBIB 10 0 K202308100013 COMMON 1 3 K202308100014 ERR-2 K202308100015 PER-CENT K202308100016 7. K202308100017 ENDCOMMON 3 0 K202308100018 DATA 3 7 K202308100019 EN-MAX DATA ERR-T K202308100020 MEV MICRO-B MICRO-B K202308100021 1100. 0.99 0.11 K202308100022 1000. 0.89 0.11 K202308100023 950. 0.87 0.11 K202308100024 700. 0.45 0.08 K202308100025 550. 0.29 0.03 K202308100026 500. 0.26 0.03 K202308100027 400. 0.10 0.03 K202308100028 ENDDATA 9 0 K202308100029 ENDSUBENT 28 0 K202308199999 SUBENT K2023082 20070712 K002K202308200001 BIB 6 13 K202308200002 REACTION (29-CU-0(G,X)17-CL-39,CUM,SIG,,BRA) K202308200003 DECAY-DATA (17-CL-39,55.6MIN,DG,250.3,0.463, K202308200004 DG,1267.2,0.536, K202308200005 DG,1517.5,0.392) K202308200006 SAMPLE - Chemical-form of target is element. K202308200007 - Physical-form of target is solid. K202308200008 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202308200009 thickness K202308200010 METHOD (CHSEP) K202308200011 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308200012 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308200013 not included in tabulated errors. K202308200014 (ERR-2) Uncertainty in detector efficiency K202308200015 ENDBIB 13 0 K202308200016 COMMON 1 3 K202308200017 ERR-2 K202308200018 PER-CENT K202308200019 7. K202308200020 ENDCOMMON 3 0 K202308200021 DATA 3 9 K202308200022 EN-MAX DATA ERR-T K202308200023 MEV MICRO-B MICRO-B K202308200024 1100. 3.86 0.44 K202308200025 1000. 2.71 0.29 K202308200026 900. 3.96 0.43 K202308200027 800. 3.41 0.35 K202308200028 700. 2.50 0.30 K202308200029 650. 2.57 0.26 K202308200030 400. 0.87 0.23 K202308200031 350. 0.23 0.17 K202308200032 300. 0.28 0.13 K202308200033 ENDDATA 11 0 K202308200034 ENDSUBENT 33 0 K202308299999 SUBENT K2023083 20070712 K002K202308300001 BIB 6 12 K202308300002 REACTION (39-Y-89(G,X)17-CL-39,CUM,SIG,,BRA) K202308300003 DECAY-DATA (17-CL-39,55.6MIN,DG,250.3,0.463, K202308300004 DG,1267.2,0.536, K202308300005 DG,1517.5,0.392) K202308300006 SAMPLE - Chemical-form of target: Y2O3 K202308300007 - Physical-form of target is solid. K202308300008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202308300009 METHOD (CHSEP) K202308300010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308300011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308300012 not included in tabulated errors. K202308300013 (ERR-2) Uncertainty in detector efficiency K202308300014 ENDBIB 12 0 K202308300015 COMMON 1 3 K202308300016 ERR-2 K202308300017 PER-CENT K202308300018 7. K202308300019 ENDCOMMON 3 0 K202308300020 DATA 3 2 K202308300021 EN-MAX DATA ERR-T K202308300022 MEV MICRO-B MICRO-B K202308300023 950. 0.25 0.06 K202308300024 800. 0.23 0.03 K202308300025 ENDDATA 4 0 K202308300026 ENDSUBENT 25 0 K202308399999 SUBENT K2023084 20070712 K002K202308400001 BIB 6 12 K202308400002 REACTION (65-TB-159(G,X)17-CL-39,CUM,SIG,,BRA) K202308400003 DECAY-DATA (17-CL-39,55.6MIN,DG,250.3,0.463, K202308400004 DG,1267.2,0.536, K202308400005 DG,1517.5,0.392) K202308400006 SAMPLE - Chemical-form of target: Tb4O7 K202308400007 - Physical-form of target is solid. K202308400008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202308400009 METHOD (CHSEP) K202308400010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308400011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308400012 not included in tabulated errors. K202308400013 (ERR-2) Uncertainty in detector efficiency K202308400014 ENDBIB 12 0 K202308400015 COMMON 1 3 K202308400016 ERR-2 K202308400017 PER-CENT K202308400018 7. K202308400019 ENDCOMMON 3 0 K202308400020 DATA 3 3 K202308400021 EN-MAX DATA ERR-T K202308400022 MEV MICRO-B MICRO-B K202308400023 950. 0.42 0.05 K202308400024 900. 0.28 0.05 K202308400025 800. 0.25 0.03 K202308400026 ENDDATA 5 0 K202308400027 ENDSUBENT 26 0 K202308499999 SUBENT K2023085 20070712 K002K202308500001 BIB 6 12 K202308500002 REACTION (67-HO-165(G,X)17-CL-39,CUM,SIG,,BRA) K202308500003 DECAY-DATA (17-CL-39,55.6MIN,DG,250.3,0.463, K202308500004 DG,1267.2,0.536, K202308500005 DG,1517.5,0.392) K202308500006 SAMPLE - Chemical-form of target: Ho2O3 K202308500007 - Physical-form of target is solid. K202308500008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202308500009 METHOD (CHSEP) K202308500010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308500011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308500012 not included in tabulated errors. K202308500013 (ERR-2) Uncertainty in detector efficiency K202308500014 ENDBIB 12 0 K202308500015 COMMON 1 3 K202308500016 ERR-2 K202308500017 PER-CENT K202308500018 7. K202308500019 ENDCOMMON 3 0 K202308500020 DATA 3 4 K202308500021 EN-MAX DATA ERR-T K202308500022 MEV MICRO-B MICRO-B K202308500023 950. 0.80 0.09 K202308500024 900. 0.63 0.07 K202308500025 800. 0.59 0.06 K202308500026 600. 0.42 0.05 K202308500027 ENDDATA 6 0 K202308500028 ENDSUBENT 27 0 K202308599999 SUBENT K2023086 20070712 K002K202308600001 BIB 6 11 K202308600002 REACTION (29-CU-0(G,X)21-SC-43,CUM,SIG,,BRA) K202308600003 DECAY-DATA (21-SC-43,3.891HR,DG,372.8,0.225) K202308600004 SAMPLE - Chemical-form of target is element. K202308600005 - Physical-form of target is solid. K202308600006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202308600007 thickness K202308600008 METHOD (CHSEP) K202308600009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308600010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308600011 not included in tabulated errors. K202308600012 (ERR-2) Uncertainty in detector efficiency K202308600013 ENDBIB 11 0 K202308600014 COMMON 1 3 K202308600015 ERR-2 K202308600016 PER-CENT K202308600017 7. K202308600018 ENDCOMMON 3 0 K202308600019 DATA 3 9 K202308600020 EN-MAX DATA ERR-T K202308600021 MEV MICRO-B MICRO-B K202308600022 1100. 46. 5. K202308600023 950. 47.2 5.0 K202308600024 900. 45.4 4.6 K202308600025 800. 40. 4. K202308600026 700. 34.7 3.6 K202308600027 650. 33. 3. K202308600028 400. 17.1 2.1 K202308600029 350. 4.23 0.70 K202308600030 300. 8.7 3.1 K202308600031 ENDDATA 11 0 K202308600032 ENDSUBENT 31 0 K202308699999 SUBENT K2023087 20070712 K002K202308700001 BIB 6 11 K202308700002 REACTION (29-CU-0(G,X)21-SC-44-G,IND,SIG,,BRA) K202308700003 DECAY-DATA (21-SC-44-G,3.927HR,DG,1157.0,0.999) K202308700004 SAMPLE - Chemical-form of target is element. K202308700005 - Physical-form of target is solid. K202308700006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202308700007 thickness K202308700008 METHOD (CHSEP) K202308700009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308700010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308700011 not included in tabulated errors. K202308700012 (ERR-2) Uncertainty in detector efficiency K202308700013 ENDBIB 11 0 K202308700014 COMMON 1 3 K202308700015 ERR-2 K202308700016 PER-CENT K202308700017 7. K202308700018 ENDCOMMON 3 0 K202308700019 DATA 3 8 K202308700020 EN-MAX DATA ERR-T K202308700021 MEV MICRO-B MICRO-B K202308700022 1100. 77. 8. K202308700023 900. 80.8 8.3 K202308700024 800. 66.8 6.9 K202308700025 700. 63.9 6.8 K202308700026 650. 52.8 5.7 K202308700027 400. 28.0 3.0 K202308700028 350. 17.4 2.1 K202308700029 300. 10.7 2.6 K202308700030 ENDDATA 10 0 K202308700031 ENDSUBENT 30 0 K202308799999 SUBENT K2023088 20070712 K002K202308800001 BIB 6 11 K202308800002 REACTION (29-CU-0(G,X)21-SC-44-M,IND,SIG,,BRA) K202308800003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202308800004 SAMPLE - Chemical-form of target is element. K202308800005 - Physical-form of target is solid. K202308800006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202308800007 thickness K202308800008 METHOD (CHSEP) K202308800009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308800010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308800011 not included in tabulated errors. K202308800012 (ERR-2) Uncertainty in detector efficiency K202308800013 ENDBIB 11 0 K202308800014 COMMON 1 3 K202308800015 ERR-2 K202308800016 PER-CENT K202308800017 7. K202308800018 ENDCOMMON 3 0 K202308800019 DATA 3 9 K202308800020 EN-MAX DATA ERR-T K202308800021 MEV MICRO-B MICRO-B K202308800022 1100. 119. 12. K202308800023 950. 147. 15. K202308800024 900. 127. 13. K202308800025 800. 122. 12. K202308800026 700. 103. 10. K202308800027 650. 99. 10. K202308800028 400. 44.2 4.9 K202308800029 350. 26.1 3.2 K202308800030 300. 13.4 1.8 K202308800031 ENDDATA 11 0 K202308800032 ENDSUBENT 31 0 K202308899999 SUBENT K2023089 20070712 K002K202308900001 BIB 6 11 K202308900002 REACTION (29-CU-0(G,X)21-SC-46,IND,SIG,,BRA) K202308900003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202308900004 SAMPLE - Chemical-form of target is element. K202308900005 - Physical-form of target is solid. K202308900006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202308900007 thickness K202308900008 METHOD (CHSEP) K202308900009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202308900010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202308900011 not included in tabulated errors. K202308900012 (ERR-2) Uncertainty in detector efficiency K202308900013 ENDBIB 11 0 K202308900014 COMMON 1 3 K202308900015 ERR-2 K202308900016 PER-CENT K202308900017 7. K202308900018 ENDCOMMON 3 0 K202308900019 DATA 3 9 K202308900020 EN-MAX DATA ERR-T K202308900021 MEV MICRO-B MICRO-B K202308900022 1100. 172. 24. K202308900023 950. 174. 20. K202308900024 900. 167. 18. K202308900025 800. 155. 19. K202308900026 700. 133. 15. K202308900027 650. 123. 15. K202308900028 400. 61. 14. K202308900029 350. 58. 14. K202308900030 300. 24.7 2.7 K202308900031 ENDDATA 11 0 K202308900032 ENDSUBENT 31 0 K202308999999 SUBENT K2023090 20070712 K002K202309000001 BIB 6 11 K202309000002 REACTION (29-CU-0(G,X)21-SC-47,IND,SIG,,BRA) K202309000003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202309000004 SAMPLE - Chemical-form of target is element. K202309000005 - Physical-form of target is solid. K202309000006 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202309000007 thickness K202309000008 METHOD (CHSEP) K202309000009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309000010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309000011 not included in tabulated errors. K202309000012 (ERR-2) Uncertainty in detector efficiency K202309000013 ENDBIB 11 0 K202309000014 COMMON 1 3 K202309000015 ERR-2 K202309000016 PER-CENT K202309000017 7. K202309000018 ENDCOMMON 3 0 K202309000019 DATA 3 9 K202309000020 EN-MAX DATA ERR-T K202309000021 MEV MICRO-B MICRO-B K202309000022 1100. 90. 9. K202309000023 950. 110. 11. K202309000024 900. 96.5 9.8 K202309000025 800. 94.1 9.6 K202309000026 700. 80.0 8.2 K202309000027 650. 78.5 8.0 K202309000028 400. 45.1 4.9 K202309000029 350. 24.5 3.0 K202309000030 300. 17.4 2.2 K202309000031 ENDDATA 11 0 K202309000032 ENDSUBENT 31 0 K202309099999 SUBENT K2023091 20070712 K002K202309100001 BIB 6 13 K202309100002 REACTION (29-CU-0(G,X)21-SC-48,IND,SIG,,BRA) K202309100003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202309100004 DG,1037.5,0.976, K202309100005 DG,1312.1,1.00) K202309100006 SAMPLE - Chemical-form of target is element. K202309100007 - Physical-form of target is solid. K202309100008 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202309100009 thickness K202309100010 METHOD (CHSEP) K202309100011 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309100012 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309100013 not included in tabulated errors. K202309100014 (ERR-2) Uncertainty in detector efficiency K202309100015 ENDBIB 13 0 K202309100016 COMMON 1 3 K202309100017 ERR-2 K202309100018 PER-CENT K202309100019 7. K202309100020 ENDCOMMON 3 0 K202309100021 DATA 3 9 K202309100022 EN-MAX DATA ERR-T K202309100023 MEV MICRO-B MICRO-B K202309100024 1100. 16. 2. K202309100025 950. 16.6 1.9 K202309100026 900. 15.7 1.7 K202309100027 800. 13.9 1.4 K202309100028 700. 14.2 1.7 K202309100029 650. 11.1 1.3 K202309100030 400. 6.4 1.5 K202309100031 350. 4.7 1.3 K202309100032 300. 2.7 1.0 K202309100033 ENDDATA 11 0 K202309100034 ENDSUBENT 33 0 K202309199999 SUBENT K2023092 20070712 K002K202309200001 BIB 6 10 K202309200002 REACTION (39-Y-89(G,X)21-SC-44-M,IND,SIG,,BRA) K202309200003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202309200004 SAMPLE - Chemical-form of target: Y2O3 K202309200005 - Physical-form of target is solid. K202309200006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309200007 METHOD (CHSEP) K202309200008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309200009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309200010 not included in tabulated errors. K202309200011 (ERR-2) Uncertainty in detector efficiency K202309200012 ENDBIB 10 0 K202309200013 COMMON 1 3 K202309200014 ERR-2 K202309200015 PER-CENT K202309200016 7. K202309200017 ENDCOMMON 3 0 K202309200018 DATA 3 1 K202309200019 EN-MAX DATA ERR-T K202309200020 MEV MICRO-B MICRO-B K202309200021 1000. 2.3 0.3 K202309200022 ENDDATA 3 0 K202309200023 ENDSUBENT 22 0 K202309299999 SUBENT K2023093 20070712 K002K202309300001 BIB 6 10 K202309300002 REACTION (39-Y-89(G,X)21-SC-46,IND,SIG,,BRA) K202309300003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202309300004 SAMPLE - Chemical-form of target: Y2O3 K202309300005 - Physical-form of target is solid. K202309300006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309300007 METHOD (CHSEP) K202309300008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309300009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309300010 not included in tabulated errors. K202309300011 (ERR-2) Uncertainty in detector efficiency K202309300012 ENDBIB 10 0 K202309300013 COMMON 1 3 K202309300014 ERR-2 K202309300015 PER-CENT K202309300016 7. K202309300017 ENDCOMMON 3 0 K202309300018 DATA 3 1 K202309300019 EN-MAX DATA ERR-T K202309300020 MEV MICRO-B MICRO-B K202309300021 1000. 3.7 0.5 K202309300022 ENDDATA 3 0 K202309300023 ENDSUBENT 22 0 K202309399999 SUBENT K2023094 20070712 K002K202309400001 BIB 6 10 K202309400002 REACTION (39-Y-89(G,X)21-SC-47,IND,SIG,,BRA) K202309400003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202309400004 SAMPLE - Chemical-form of target: Y2O3 K202309400005 - Physical-form of target is solid. K202309400006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309400007 METHOD (CHSEP) K202309400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309400010 not included in tabulated errors. K202309400011 (ERR-2) Uncertainty in detector efficiency K202309400012 ENDBIB 10 0 K202309400013 COMMON 1 3 K202309400014 ERR-2 K202309400015 PER-CENT K202309400016 7. K202309400017 ENDCOMMON 3 0 K202309400018 DATA 3 1 K202309400019 EN-MAX DATA ERR-T K202309400020 MEV MICRO-B MICRO-B K202309400021 1000. 3.3 0.4 K202309400022 ENDDATA 3 0 K202309400023 ENDSUBENT 22 0 K202309499999 SUBENT K2023095 20070712 K002K202309500001 BIB 6 12 K202309500002 REACTION (39-Y-89(G,X)21-SC-48,IND,SIG,,BRA) K202309500003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202309500004 DG,1037.5,0.976, K202309500005 DG,1312.1,1.00) K202309500006 SAMPLE - Chemical-form of target: Y2O3 K202309500007 - Physical-form of target is solid. K202309500008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309500009 METHOD (CHSEP) K202309500010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309500011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309500012 not included in tabulated errors. K202309500013 (ERR-2) Uncertainty in detector efficiency K202309500014 ENDBIB 12 0 K202309500015 COMMON 1 3 K202309500016 ERR-2 K202309500017 PER-CENT K202309500018 7. K202309500019 ENDCOMMON 3 0 K202309500020 DATA 3 1 K202309500021 EN-MAX DATA ERR-T K202309500022 MEV MICRO-B MICRO-B K202309500023 1000. 0.56 0.07 K202309500024 ENDDATA 3 0 K202309500025 ENDSUBENT 24 0 K202309599999 SUBENT K2023096 20070712 K002K202309600001 BIB 6 10 K202309600002 REACTION (47-AG-0(G,X)21-SC-44-M,IND,SIG,,BRA) K202309600003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202309600004 SAMPLE - Chemical-form of target is element. K202309600005 - Physical-form of target is solid. K202309600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309600007 METHOD (CHSEP) K202309600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309600010 not included in tabulated errors. K202309600011 (ERR-2) Uncertainty in detector efficiency K202309600012 ENDBIB 10 0 K202309600013 COMMON 1 3 K202309600014 ERR-2 K202309600015 PER-CENT K202309600016 7. K202309600017 ENDCOMMON 3 0 K202309600018 DATA 3 5 K202309600019 EN-MAX DATA ERR-T K202309600020 MEV MICRO-B MICRO-B K202309600021 1100. 0.63 0.07 K202309600022 900. 0.52 0.06 K202309600023 800. 0.42 0.05 K202309600024 700. 0.21 0.02 K202309600025 650. 0.22 0.05 K202309600026 ENDDATA 7 0 K202309600027 ENDSUBENT 26 0 K202309699999 SUBENT K2023097 20070712 K002K202309700001 BIB 6 10 K202309700002 REACTION (47-AG-0(G,X)21-SC-46,IND,SIG,,BRA) K202309700003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202309700004 SAMPLE - Chemical-form of target is element. K202309700005 - Physical-form of target is solid. K202309700006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309700007 METHOD (CHSEP) K202309700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309700010 not included in tabulated errors. K202309700011 (ERR-2) Uncertainty in detector efficiency K202309700012 ENDBIB 10 0 K202309700013 COMMON 1 3 K202309700014 ERR-2 K202309700015 PER-CENT K202309700016 7. K202309700017 ENDCOMMON 3 0 K202309700018 DATA 3 4 K202309700019 EN-MAX DATA ERR-T K202309700020 MEV MICRO-B MICRO-B K202309700021 1100. 0.96 0.11 K202309700022 900. 0.92 0.17 K202309700023 800. 0.55 0.15 K202309700024 700. 0.36 0.08 K202309700025 ENDDATA 6 0 K202309700026 ENDSUBENT 25 0 K202309799999 SUBENT K2023098 20070712 K002K202309800001 BIB 6 10 K202309800002 REACTION (47-AG-0(G,X)21-SC-47,IND,SIG,,BRA) K202309800003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202309800004 SAMPLE - Chemical-form of target is element. K202309800005 - Physical-form of target is solid. K202309800006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309800007 METHOD (CHSEP) K202309800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309800010 not included in tabulated errors. K202309800011 (ERR-2) Uncertainty in detector efficiency K202309800012 ENDBIB 10 0 K202309800013 COMMON 1 3 K202309800014 ERR-2 K202309800015 PER-CENT K202309800016 7. K202309800017 ENDCOMMON 3 0 K202309800018 DATA 3 6 K202309800019 EN-MAX DATA ERR-T K202309800020 MEV MICRO-B MICRO-B K202309800021 1100. 0.65 0.07 K202309800022 900. 0.65 0.07 K202309800023 800. 0.54 0.06 K202309800024 700. 0.27 0.03 K202309800025 650. 0.21 0.04 K202309800026 400. 0.096 0.032 K202309800027 ENDDATA 8 0 K202309800028 ENDSUBENT 27 0 K202309899999 SUBENT K2023099 20070712 K002K202309900001 BIB 6 12 K202309900002 REACTION (47-AG-0(G,X)21-SC-48,IND,SIG,,BRA) K202309900003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202309900004 DG,1037.5,0.976, K202309900005 DG,1312.1,1.00) K202309900006 SAMPLE - Chemical-form of target is element. K202309900007 - Physical-form of target is solid. K202309900008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202309900009 METHOD (CHSEP) K202309900010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202309900011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202309900012 not included in tabulated errors. K202309900013 (ERR-2) Uncertainty in detector efficiency K202309900014 ENDBIB 12 0 K202309900015 COMMON 1 3 K202309900016 ERR-2 K202309900017 PER-CENT K202309900018 7. K202309900019 ENDCOMMON 3 0 K202309900020 DATA 3 5 K202309900021 EN-MAX DATA ERR-T K202309900022 MEV MICRO-B MICRO-B K202309900023 1100. 0.14 0.02 K202309900024 900. 0.16 0.03 K202309900025 800. 0.15 0.03 K202309900026 700. 0.054 0.008 K202309900027 650. 0.073 0.035 K202309900028 ENDDATA 7 0 K202309900029 ENDSUBENT 28 0 K202309999999 SUBENT K2023100 20070712 K002K202310000001 BIB 6 10 K202310000002 REACTION (49-IN-0(G,X)21-SC-44-M,IND,SIG,,BRA) K202310000003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202310000004 SAMPLE - Chemical-form of target is element. K202310000005 - Physical-form of target is solid. K202310000006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310000007 METHOD (CHSEP) K202310000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310000010 not included in tabulated errors. K202310000011 (ERR-2) Uncertainty in detector efficiency K202310000012 ENDBIB 10 0 K202310000013 COMMON 1 3 K202310000014 ERR-2 K202310000015 PER-CENT K202310000016 7. K202310000017 ENDCOMMON 3 0 K202310000018 DATA 3 1 K202310000019 EN-MAX DATA ERR-T K202310000020 MEV MICRO-B MICRO-B K202310000021 900. 0.30 0.07 K202310000022 ENDDATA 3 0 K202310000023 ENDSUBENT 22 0 K202310099999 SUBENT K2023101 20070712 K002K202310100001 BIB 6 10 K202310100002 REACTION (49-IN-0(G,X)21-SC-46,IND,SIG,,BRA) K202310100003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202310100004 SAMPLE - Chemical-form of target is element. K202310100005 - Physical-form of target is solid. K202310100006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310100007 METHOD (CHSEP) K202310100008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310100009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310100010 not included in tabulated errors. K202310100011 (ERR-2) Uncertainty in detector efficiency K202310100012 ENDBIB 10 0 K202310100013 COMMON 1 3 K202310100014 ERR-2 K202310100015 PER-CENT K202310100016 7. K202310100017 ENDCOMMON 3 0 K202310100018 DATA 3 1 K202310100019 EN-MAX DATA ERR-T K202310100020 MEV MICRO-B MICRO-B K202310100021 900. 0.55 0.14 K202310100022 ENDDATA 3 0 K202310100023 ENDSUBENT 22 0 K202310199999 SUBENT K2023102 20070712 K002K202310200001 BIB 6 10 K202310200002 REACTION (49-IN-0(G,X)21-SC-47,IND,SIG,,BRA) K202310200003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202310200004 SAMPLE - Chemical-form of target is element. K202310200005 - Physical-form of target is solid. K202310200006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310200007 METHOD (CHSEP) K202310200008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310200009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310200010 not included in tabulated errors. K202310200011 (ERR-2) Uncertainty in detector efficiency K202310200012 ENDBIB 10 0 K202310200013 COMMON 1 3 K202310200014 ERR-2 K202310200015 PER-CENT K202310200016 7. K202310200017 ENDCOMMON 3 0 K202310200018 DATA 3 1 K202310200019 EN-MAX DATA ERR-T K202310200020 MEV MICRO-B MICRO-B K202310200021 900. 0.56 0.07 K202310200022 ENDDATA 3 0 K202310200023 ENDSUBENT 22 0 K202310299999 SUBENT K2023103 20070712 K002K202310300001 BIB 6 12 K202310300002 REACTION (49-IN-0(G,X)21-SC-48,IND,SIG,,BRA) K202310300003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202310300004 DG,1037.5,0.976, K202310300005 DG,1312.1,1.00) K202310300006 SAMPLE - Chemical-form of target is element. K202310300007 - Physical-form of target is solid. K202310300008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310300009 METHOD (CHSEP) K202310300010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310300011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310300012 not included in tabulated errors. K202310300013 (ERR-2) Uncertainty in detector efficiency K202310300014 ENDBIB 12 0 K202310300015 COMMON 1 3 K202310300016 ERR-2 K202310300017 PER-CENT K202310300018 7. K202310300019 ENDCOMMON 3 0 K202310300020 DATA 3 1 K202310300021 EN-MAX DATA ERR-T K202310300022 MEV MICRO-B MICRO-B K202310300023 900. 0.25 0.05 K202310300024 ENDDATA 3 0 K202310300025 ENDSUBENT 24 0 K202310399999 SUBENT K2023104 20070712 K002K202310400001 BIB 6 10 K202310400002 REACTION (67-HO-165(G,X)21-SC-44-M,IND,SIG,,BRA) K202310400003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202310400004 SAMPLE - Chemical-form of target: Ho2O3 K202310400005 - Physical-form of target is solid. K202310400006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310400007 METHOD (CHSEP) K202310400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310400010 not included in tabulated errors. K202310400011 (ERR-2) Uncertainty in detector efficiency K202310400012 ENDBIB 10 0 K202310400013 COMMON 1 3 K202310400014 ERR-2 K202310400015 PER-CENT K202310400016 7. K202310400017 ENDCOMMON 3 0 K202310400018 DATA 3 1 K202310400019 EN-MAX DATA ERR-T K202310400020 MEV MICRO-B MICRO-B K202310400021 1000. 0.28 0.03 K202310400022 ENDDATA 3 0 K202310400023 ENDSUBENT 22 0 K202310499999 SUBENT K2023105 20070712 K002K202310500001 BIB 6 10 K202310500002 REACTION (67-HO-165(G,X)21-SC-46,IND,SIG,,BRA) K202310500003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202310500004 SAMPLE - Chemical-form of target: Ho2O3 K202310500005 - Physical-form of target is solid. K202310500006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310500007 METHOD (CHSEP) K202310500008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310500009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310500010 not included in tabulated errors. K202310500011 (ERR-2) Uncertainty in detector efficiency K202310500012 ENDBIB 10 0 K202310500013 COMMON 1 3 K202310500014 ERR-2 K202310500015 PER-CENT K202310500016 7. K202310500017 ENDCOMMON 3 0 K202310500018 DATA 3 1 K202310500019 EN-MAX DATA ERR-T K202310500020 MEV MICRO-B MICRO-B K202310500021 1000. 1.18 0.16 K202310500022 ENDDATA 3 0 K202310500023 ENDSUBENT 22 0 K202310599999 SUBENT K2023106 20070712 K002K202310600001 BIB 6 10 K202310600002 REACTION (67-HO-165(G,X)21-SC-47,IND,SIG,,BRA) K202310600003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202310600004 SAMPLE - Chemical-form of target: Ho2O3 K202310600005 - Physical-form of target is solid. K202310600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310600007 METHOD (CHSEP) K202310600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310600010 not included in tabulated errors. K202310600011 (ERR-2) Uncertainty in detector efficiency K202310600012 ENDBIB 10 0 K202310600013 COMMON 1 3 K202310600014 ERR-2 K202310600015 PER-CENT K202310600016 7. K202310600017 ENDCOMMON 3 0 K202310600018 DATA 3 1 K202310600019 EN-MAX DATA ERR-T K202310600020 MEV MICRO-B MICRO-B K202310600021 1000. 1.83 0.19 K202310600022 ENDDATA 3 0 K202310600023 ENDSUBENT 22 0 K202310699999 SUBENT K2023107 20070712 K002K202310700001 BIB 6 12 K202310700002 REACTION (67-HO-165(G,X)21-SC-48,IND,SIG,,BRA) K202310700003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202310700004 DG,1037.5,0.976, K202310700005 DG,1312.1,1.00) K202310700006 SAMPLE - Chemical-form of target: Ho2O3 K202310700007 - Physical-form of target is solid. K202310700008 - Target-thickness is 2000 mg/cm**2. Typical thickness K202310700009 METHOD (CHSEP) K202310700010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310700011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310700012 not included in tabulated errors. K202310700013 (ERR-2) Uncertainty in detector efficiency K202310700014 ENDBIB 12 0 K202310700015 COMMON 1 3 K202310700016 ERR-2 K202310700017 PER-CENT K202310700018 7. K202310700019 ENDCOMMON 3 0 K202310700020 DATA 3 1 K202310700021 EN-MAX DATA ERR-T K202310700022 MEV MICRO-B MICRO-B K202310700023 1000. 0.57 0.06 K202310700024 ENDDATA 3 0 K202310700025 ENDSUBENT 24 0 K202310799999 SUBENT K2023108 20070712 K002K202310800001 BIB 6 10 K202310800002 REACTION (79-AU-197(G,X)21-SC-44-M,IND,SIG,,BRA) K202310800003 DECAY-DATA (21-SC-44-M,58.6HR,DG,271.1,0.867) K202310800004 SAMPLE - Chemical-form of target is element. K202310800005 - Physical-form of target is solid. K202310800006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202310800007 METHOD (CHSEP) K202310800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310800010 not included in tabulated errors. K202310800011 (ERR-2) Uncertainty in detector efficiency K202310800012 ENDBIB 10 0 K202310800013 COMMON 1 3 K202310800014 ERR-2 K202310800015 PER-CENT K202310800016 7. K202310800017 ENDCOMMON 3 0 K202310800018 DATA 3 7 K202310800019 EN-MAX DATA ERR-T K202310800020 MEV MICRO-B MICRO-B K202310800021 1100. 0.41 0.05 K202310800022 950. 0.49 0.08 K202310800023 900. 0.34 0.05 K202310800024 800. 0.25 0.04 K202310800025 650. 0.21 0.05 K202310800026 550. 0.14 0.02 K202310800027 400. 0.054 0.038 K202310800028 ENDDATA 9 0 K202310800029 ENDSUBENT 28 0 K202310899999 SUBENT K2023109 20070712 K002K202310900001 BIB 6 10 K202310900002 REACTION (79-AU-197(G,X)21-SC-46,IND,SIG,,BRA) K202310900003 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.99984) K202310900004 SAMPLE - Chemical-form of target is element. K202310900005 - Physical-form of target is solid. K202310900006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202310900007 METHOD (CHSEP) K202310900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202310900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202310900010 not included in tabulated errors. K202310900011 (ERR-2) Uncertainty in detector efficiency K202310900012 ENDBIB 10 0 K202310900013 COMMON 1 3 K202310900014 ERR-2 K202310900015 PER-CENT K202310900016 7. K202310900017 ENDCOMMON 3 0 K202310900018 DATA 3 9 K202310900019 EN-MAX DATA ERR-T K202310900020 MEV MICRO-B MICRO-B K202310900021 1100. 3.0 0.3 K202310900022 950. 3.1 0.6 K202310900023 900. 2.22 0.37 K202310900024 800. 1.8 0.3 K202310900025 700. 1.8 0.8 K202310900026 650. 1.4 0.3 K202310900027 550. 0.85 0.10 K202310900028 500. 0.77 0.16 K202310900029 400. 0.51 0.22 K202310900030 ENDDATA 11 0 K202310900031 ENDSUBENT 30 0 K202310999999 SUBENT K2023110 20070712 K002K202311000001 BIB 6 10 K202311000002 REACTION (79-AU-197(G,X)21-SC-47,IND,SIG,,BRA) K202311000003 DECAY-DATA (21-SC-47,3.345D,DG,159.4,0.679) K202311000004 SAMPLE - Chemical-form of target is element. K202311000005 - Physical-form of target is solid. K202311000006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202311000007 METHOD (CHSEP) K202311000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311000010 not included in tabulated errors. K202311000011 (ERR-2) Uncertainty in detector efficiency K202311000012 ENDBIB 10 0 K202311000013 COMMON 1 3 K202311000014 ERR-2 K202311000015 PER-CENT K202311000016 7. K202311000017 ENDCOMMON 3 0 K202311000018 DATA 3 8 K202311000019 EN-MAX DATA ERR-T K202311000020 MEV MICRO-B MICRO-B K202311000021 1100. 4.7 0.5 K202311000022 950. 4.5 0.5 K202311000023 900. 4.0 0.4 K202311000024 800. 3.2 0.3 K202311000025 700. 3.0 0.4 K202311000026 650. 2.4 0.3 K202311000027 500. 1.72 0.22 K202311000028 400. 0.93 0.11 K202311000029 ENDDATA 10 0 K202311000030 ENDSUBENT 29 0 K202311099999 SUBENT K2023111 20070712 K002K202311100001 BIB 6 12 K202311100002 REACTION (79-AU-197(G,X)21-SC-48,IND,SIG,,BRA) K202311100003 DECAY-DATA (21-SC-48,43.67HR,DG,983.5,1.00, K202311100004 DG,1037.5,0.976, K202311100005 DG,1312.1,1.00) K202311100006 SAMPLE - Chemical-form of target is element. K202311100007 - Physical-form of target is solid. K202311100008 - Target-thickness is 3000 mg/cm**2. Typical thickness K202311100009 METHOD (CHSEP) K202311100010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311100011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311100012 not included in tabulated errors. K202311100013 (ERR-2) Uncertainty in detector efficiency K202311100014 ENDBIB 12 0 K202311100015 COMMON 1 3 K202311100016 ERR-2 K202311100017 PER-CENT K202311100018 7. K202311100019 ENDCOMMON 3 0 K202311100020 DATA 3 9 K202311100021 EN-MAX DATA ERR-T K202311100022 MEV MICRO-B MICRO-B K202311100023 1100. 2.3 0.3 K202311100024 950. 2.0 0.2 K202311100025 900. 2.2 0.2 K202311100026 800. 1.7 0.2 K202311100027 700. 1.6 0.3 K202311100028 650. 1.3 0.2 K202311100029 550. 0.83 0.22 K202311100030 500. 1.14 0.13 K202311100031 400. 0.51 0.09 K202311100032 ENDDATA 11 0 K202311100033 ENDSUBENT 32 0 K202311199999 SUBENT K2023112 20070712 K002K202311200001 BIB 6 12 K202311200002 REACTION (29-CU-0(G,X)26-FE-59,CUM,SIG,,BRA) K202311200003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311200004 DG,1291.6,0.432) K202311200005 SAMPLE - Chemical-form of target is element. K202311200006 - Physical-form of target is solid. K202311200007 - Target-thickness is 400 to 1200 mg/cm**2. Typical K202311200008 thickness K202311200009 METHOD (CHSEP) K202311200010 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311200011 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311200012 not included in tabulated errors. K202311200013 (ERR-2) Uncertainty in detector efficiency K202311200014 ENDBIB 12 0 K202311200015 COMMON 1 3 K202311200016 ERR-2 K202311200017 PER-CENT K202311200018 7. K202311200019 ENDCOMMON 3 0 K202311200020 DATA 3 7 K202311200021 EN-MAX DATA ERR-T K202311200022 MEV MICRO-B MICRO-B K202311200023 1100. 133. 14. K202311200024 900. 128. 13. K202311200025 800. 142. 15. K202311200026 700. 114. 12. K202311200027 400. 71.5 7.3 K202311200028 350. 71.7 7.4 K202311200029 300. 70.6 7.5 K202311200030 ENDDATA 9 0 K202311200031 ENDSUBENT 30 0 K202311299999 SUBENT K2023113 20070712 K002K202311300001 BIB 6 11 K202311300002 REACTION (39-Y-89(G,X)26-FE-59,CUM,SIG,,BRA) K202311300003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311300004 DG,1291.6,0.432) K202311300005 SAMPLE - Chemical-form of target: Y2O3 K202311300006 - Physical-form of target is solid. K202311300007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311300008 METHOD (CHSEP) K202311300009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311300010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311300011 not included in tabulated errors. K202311300012 (ERR-2) Uncertainty in detector efficiency K202311300013 ENDBIB 11 0 K202311300014 COMMON 1 3 K202311300015 ERR-2 K202311300016 PER-CENT K202311300017 7. K202311300018 ENDCOMMON 3 0 K202311300019 DATA 3 2 K202311300020 EN-MAX DATA ERR-T K202311300021 MEV MICRO-B MICRO-B K202311300022 1000. 7.3 0.8 K202311300023 800. 4.8 0.6 K202311300024 ENDDATA 4 0 K202311300025 ENDSUBENT 24 0 K202311399999 SUBENT K2023114 20070712 K002K202311400001 BIB 6 11 K202311400002 REACTION (47-AG-0(G,X)26-FE-59,CUM,SIG,,BRA) K202311400003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311400004 DG,1291.6,0.432) K202311400005 SAMPLE - Chemical-form of target is element. K202311400006 - Physical-form of target is solid. K202311400007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311400008 METHOD (CHSEP) K202311400009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311400010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311400011 not included in tabulated errors. K202311400012 (ERR-2) Uncertainty in detector efficiency K202311400013 ENDBIB 11 0 K202311400014 COMMON 1 3 K202311400015 ERR-2 K202311400016 PER-CENT K202311400017 7. K202311400018 ENDCOMMON 3 0 K202311400019 DATA 3 3 K202311400020 EN-MAX DATA ERR-T K202311400021 MEV MICRO-B MICRO-B K202311400022 1100. 0.57 0.08 K202311400023 900. 0.56 0.09 K202311400024 800. 0.45 0.09 K202311400025 ENDDATA 5 0 K202311400026 ENDSUBENT 25 0 K202311499999 SUBENT K2023115 20070712 K002K202311500001 BIB 6 11 K202311500002 REACTION (65-TB-159(G,X)26-FE-59,CUM,SIG,,BRA) K202311500003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311500004 DG,1291.6,0.432) K202311500005 SAMPLE - Chemical-form of target: Tb4O7 K202311500006 - Physical-form of target is solid. K202311500007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311500008 METHOD (CHSEP) K202311500009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311500010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311500011 not included in tabulated errors. K202311500012 (ERR-2) Uncertainty in detector efficiency K202311500013 ENDBIB 11 0 K202311500014 COMMON 1 3 K202311500015 ERR-2 K202311500016 PER-CENT K202311500017 7. K202311500018 ENDCOMMON 3 0 K202311500019 DATA 3 1 K202311500020 EN-MAX DATA ERR-T K202311500021 MEV MICRO-B MICRO-B K202311500022 800. 1.1 0.2 K202311500023 ENDDATA 3 0 K202311500024 ENDSUBENT 23 0 K202311599999 SUBENT K2023116 20070712 K002K202311600001 BIB 6 11 K202311600002 REACTION (67-HO-165(G,X)26-FE-59,CUM,SIG,,BRA) K202311600003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311600004 DG,1291.6,0.432) K202311600005 SAMPLE - Chemical-form of target: Ho2O3 K202311600006 - Physical-form of target is solid. K202311600007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311600008 METHOD (CHSEP) K202311600009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311600010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311600011 not included in tabulated errors. K202311600012 (ERR-2) Uncertainty in detector efficiency K202311600013 ENDBIB 11 0 K202311600014 COMMON 1 3 K202311600015 ERR-2 K202311600016 PER-CENT K202311600017 7. K202311600018 ENDCOMMON 3 0 K202311600019 DATA 3 2 K202311600020 EN-MAX DATA ERR-T K202311600021 MEV MICRO-B MICRO-B K202311600022 1000. 2.0 0.2 K202311600023 800. 1.8 0.3 K202311600024 ENDDATA 4 0 K202311600025 ENDSUBENT 24 0 K202311699999 SUBENT K2023117 20070712 K002K202311700001 BIB 6 11 K202311700002 REACTION (79-AU-197(G,X)26-FE-59,CUM,SIG,,BRA) K202311700003 DECAY-DATA (26-FE-59,44.503D,DG,1099.3,0.565, K202311700004 DG,1291.6,0.432) K202311700005 SAMPLE - Chemical-form of target is element. K202311700006 - Physical-form of target is solid. K202311700007 - Target-thickness is 3000 mg/cm**2. Typical thickness K202311700008 METHOD (CHSEP) K202311700009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311700010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311700011 not included in tabulated errors. K202311700012 (ERR-2) Uncertainty in detector efficiency K202311700013 ENDBIB 11 0 K202311700014 COMMON 1 3 K202311700015 ERR-2 K202311700016 PER-CENT K202311700017 7. K202311700018 ENDCOMMON 3 0 K202311700019 DATA 3 6 K202311700020 EN-MAX DATA ERR-T K202311700021 MEV MICRO-B MICRO-B K202311700022 1100. 13.3 1.4 K202311700023 900. 12.3 1.3 K202311700024 800. 11.2 1.2 K202311700025 700. 12. 2. K202311700026 650. 8.4 1.0 K202311700027 400. 4.65 0.51 K202311700028 ENDDATA 8 0 K202311700029 ENDSUBENT 28 0 K202311799999 SUBENT K2023118 20070712 K002K202311800001 BIB 6 10 K202311800002 REACTION (39-Y-89(G,X)27-CO-56,IND,SIG,,BRA) K202311800003 DECAY-DATA (27-CO-56,77.727D,DG,846.8,0.99935) K202311800004 SAMPLE - Chemical-form of target: Y2O3 K202311800005 - Physical-form of target is solid. K202311800006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311800007 METHOD (CHSEP) K202311800008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311800009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311800010 not included in tabulated errors. K202311800011 (ERR-2) Uncertainty in detector efficiency K202311800012 ENDBIB 10 0 K202311800013 COMMON 1 3 K202311800014 ERR-2 K202311800015 PER-CENT K202311800016 7. K202311800017 ENDCOMMON 3 0 K202311800018 DATA 3 1 K202311800019 EN-MAX DATA ERR-T K202311800020 MEV MICRO-B MICRO-B K202311800021 950. 4.93 0.71 K202311800022 ENDDATA 3 0 K202311800023 ENDSUBENT 22 0 K202311899999 SUBENT K2023119 20070712 K002K202311900001 BIB 6 10 K202311900002 REACTION (39-Y-89(G,X)27-CO-57,IND,SIG,,BRA) K202311900003 DECAY-DATA (27-CO-57,271.79D,DG,122.1,0.8560) K202311900004 SAMPLE - Chemical-form of target: Y2O3 K202311900005 - Physical-form of target is solid. K202311900006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202311900007 METHOD (CHSEP) K202311900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202311900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202311900010 not included in tabulated errors. K202311900011 (ERR-2) Uncertainty in detector efficiency K202311900012 ENDBIB 10 0 K202311900013 COMMON 1 3 K202311900014 ERR-2 K202311900015 PER-CENT K202311900016 7. K202311900017 ENDCOMMON 3 0 K202311900018 DATA 3 1 K202311900019 EN-MAX DATA ERR-T K202311900020 MEV MICRO-B MICRO-B K202311900021 950. 28.9 3.1 K202311900022 ENDDATA 3 0 K202311900023 ENDSUBENT 22 0 K202311999999 SUBENT K2023120 20070712 K002K202312000001 BIB 6 10 K202312000002 REACTION (39-Y-89(G,X)27-CO-58,IND,SIG,,BRA) K202312000003 DECAY-DATA (27-CO-58-G,70.82D,DG,810.8,0.99448) K202312000004 SAMPLE - Chemical-form of target: Y2O3 K202312000005 - Physical-form of target is solid. K202312000006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312000007 METHOD (CHSEP) K202312000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312000010 not included in tabulated errors. K202312000011 (ERR-2) Uncertainty in detector efficiency K202312000012 ENDBIB 10 0 K202312000013 COMMON 1 3 K202312000014 ERR-2 K202312000015 PER-CENT K202312000016 7. K202312000017 ENDCOMMON 3 0 K202312000018 DATA 3 1 K202312000019 EN-MAX DATA ERR-T K202312000020 MEV MICRO-B MICRO-B K202312000021 950. 38.3 4.0 K202312000022 ENDDATA 3 0 K202312000023 ENDSUBENT 22 0 K202312099999 SUBENT K2023121 20070712 K002K202312100001 BIB 6 11 K202312100002 REACTION (39-Y-89(G,X)27-CO-60,IND,SIG,,BRA) K202312100003 DECAY-DATA (27-CO-60-G,5.2714YR,DG,1173.2,0.9990, K202312100004 DG,1332.5,0.999820) K202312100005 SAMPLE - Chemical-form of target: Y2O3 K202312100006 - Physical-form of target is solid. K202312100007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312100008 METHOD (CHSEP) K202312100009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312100010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312100011 not included in tabulated errors. K202312100012 (ERR-2) Uncertainty in detector efficiency K202312100013 ENDBIB 11 0 K202312100014 COMMON 1 3 K202312100015 ERR-2 K202312100016 PER-CENT K202312100017 7. K202312100018 ENDCOMMON 3 0 K202312100019 DATA 3 1 K202312100020 EN-MAX DATA ERR-T K202312100021 MEV MICRO-B MICRO-B K202312100022 950. 16.6 3.3 K202312100023 ENDDATA 3 0 K202312100024 ENDSUBENT 23 0 K202312199999 SUBENT K2023122 20070712 K002K202312200001 BIB 6 10 K202312200002 REACTION (47-AG-0(G,X)27-CO-56,IND,SIG,,BRA) K202312200003 DECAY-DATA (27-CO-56,77.727D,DG,846.8,0.99935) K202312200004 SAMPLE - Chemical-form of target is element. K202312200005 - Physical-form of target is solid. K202312200006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312200007 METHOD (CHSEP) K202312200008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312200009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312200010 not included in tabulated errors. K202312200011 (ERR-2) Uncertainty in detector efficiency K202312200012 ENDBIB 10 0 K202312200013 COMMON 1 3 K202312200014 ERR-2 K202312200015 PER-CENT K202312200016 7. K202312200017 ENDCOMMON 3 0 K202312200018 DATA 3 1 K202312200019 EN-MAX DATA ERR-T K202312200020 MEV MICRO-B MICRO-B K202312200021 1100. 0.67 0.09 K202312200022 ENDDATA 3 0 K202312200023 ENDSUBENT 22 0 K202312299999 SUBENT K2023123 20070712 K002K202312300001 BIB 6 10 K202312300002 REACTION (47-AG-0(G,X)27-CO-57,IND,SIG,,BRA) K202312300003 DECAY-DATA (27-CO-57,271.79D,DG,122.1,0.8560) K202312300004 SAMPLE - Chemical-form of target is element. K202312300005 - Physical-form of target is solid. K202312300006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312300007 METHOD (CHSEP) K202312300008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312300009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312300010 not included in tabulated errors. K202312300011 (ERR-2) Uncertainty in detector efficiency K202312300012 ENDBIB 10 0 K202312300013 COMMON 1 3 K202312300014 ERR-2 K202312300015 PER-CENT K202312300016 7. K202312300017 ENDCOMMON 3 0 K202312300018 DATA 3 2 K202312300019 EN-MAX DATA ERR-T K202312300020 MEV MICRO-B MICRO-B K202312300021 1100. 2.91 0.31 K202312300022 400. 0.37 0.22 K202312300023 ENDDATA 4 0 K202312300024 ENDSUBENT 23 0 K202312399999 SUBENT K2023124 20070712 K002K202312400001 BIB 6 10 K202312400002 REACTION (47-AG-0(G,X)27-CO-58,IND,SIG,,BRA) K202312400003 DECAY-DATA (27-CO-58-G,70.82D,DG,810.8,0.99448) K202312400004 SAMPLE - Chemical-form of target is element. K202312400005 - Physical-form of target is solid. K202312400006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312400007 METHOD (CHSEP) K202312400008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312400009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312400010 not included in tabulated errors. K202312400011 (ERR-2) Uncertainty in detector efficiency K202312400012 ENDBIB 10 0 K202312400013 COMMON 1 3 K202312400014 ERR-2 K202312400015 PER-CENT K202312400016 7. K202312400017 ENDCOMMON 3 0 K202312400018 DATA 3 2 K202312400019 EN-MAX DATA ERR-T K202312400020 MEV MICRO-B MICRO-B K202312400021 1100. 4.32 0.45 K202312400022 400. 0.52 0.18 K202312400023 ENDDATA 4 0 K202312400024 ENDSUBENT 23 0 K202312499999 SUBENT K2023125 20070712 K002K202312500001 BIB 6 11 K202312500002 REACTION (47-AG-0(G,X)27-CO-60,IND,SIG,,BRA) K202312500003 DECAY-DATA (27-CO-60-G,5.2714YR,DG,1173.2,0.9990, K202312500004 DG,1332.5,0.999820) K202312500005 SAMPLE - Chemical-form of target is element. K202312500006 - Physical-form of target is solid. K202312500007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312500008 METHOD (CHSEP) K202312500009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312500010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312500011 not included in tabulated errors. K202312500012 (ERR-2) Uncertainty in detector efficiency K202312500013 ENDBIB 11 0 K202312500014 COMMON 1 3 K202312500015 ERR-2 K202312500016 PER-CENT K202312500017 7. K202312500018 ENDCOMMON 3 0 K202312500019 DATA 3 2 K202312500020 EN-MAX DATA ERR-T K202312500021 MEV MICRO-B MICRO-B K202312500022 1100. 2.52 0.56 K202312500023 400. 2.1 1.4 K202312500024 ENDDATA 4 0 K202312500025 ENDSUBENT 24 0 K202312599999 SUBENT K2023126 20070712 K002K202312600001 BIB 6 10 K202312600002 REACTION (67-HO-165(G,X)27-CO-57,IND,SIG,,BRA) K202312600003 DECAY-DATA (27-CO-57,271.79D,DG,122.1,0.8560) K202312600004 SAMPLE - Chemical-form of target: Ho2O3 K202312600005 - Physical-form of target is solid. K202312600006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312600007 METHOD (CHSEP) K202312600008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312600009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312600010 not included in tabulated errors. K202312600011 (ERR-2) Uncertainty in detector efficiency K202312600012 ENDBIB 10 0 K202312600013 COMMON 1 3 K202312600014 ERR-2 K202312600015 PER-CENT K202312600016 7. K202312600017 ENDCOMMON 3 0 K202312600018 DATA 3 1 K202312600019 EN-MAX DATA ERR-T K202312600020 MEV MICRO-B MICRO-B K202312600021 1000. 0.46 0.13 K202312600022 ENDDATA 3 0 K202312600023 ENDSUBENT 22 0 K202312699999 SUBENT K2023127 20070712 K002K202312700001 BIB 6 10 K202312700002 REACTION (67-HO-165(G,X)27-CO-58,IND,SIG,,BRA) K202312700003 DECAY-DATA (27-CO-58-G,70.82D,DG,810.8,0.99448) K202312700004 SAMPLE - Chemical-form of target: Ho2O3 K202312700005 - Physical-form of target is solid. K202312700006 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312700007 METHOD (CHSEP) K202312700008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312700009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312700010 not included in tabulated errors. K202312700011 (ERR-2) Uncertainty in detector efficiency K202312700012 ENDBIB 10 0 K202312700013 COMMON 1 3 K202312700014 ERR-2 K202312700015 PER-CENT K202312700016 7. K202312700017 ENDCOMMON 3 0 K202312700018 DATA 3 1 K202312700019 EN-MAX DATA ERR-T K202312700020 MEV MICRO-B MICRO-B K202312700021 1000. 1.04 0.14 K202312700022 ENDDATA 3 0 K202312700023 ENDSUBENT 22 0 K202312799999 SUBENT K2023128 20070712 K002K202312800001 BIB 6 11 K202312800002 REACTION (67-HO-165(G,X)27-CO-60,IND,SIG,,BRA) K202312800003 DECAY-DATA (27-CO-60-G,5.2714YR,DG,1173.2,0.9990, K202312800004 DG,1332.5,0.999820) K202312800005 SAMPLE - Chemical-form of target: Ho2O3 K202312800006 - Physical-form of target is solid. K202312800007 - Target-thickness is 2000 mg/cm**2. Typical thickness K202312800008 METHOD (CHSEP) K202312800009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312800010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312800011 not included in tabulated errors. K202312800012 (ERR-2) Uncertainty in detector efficiency K202312800013 ENDBIB 11 0 K202312800014 COMMON 1 3 K202312800015 ERR-2 K202312800016 PER-CENT K202312800017 7. K202312800018 ENDCOMMON 3 0 K202312800019 DATA 3 1 K202312800020 EN-MAX DATA ERR-T K202312800021 MEV MICRO-B MICRO-B K202312800022 1000. 3.25 0.62 K202312800023 ENDDATA 3 0 K202312800024 ENDSUBENT 23 0 K202312899999 SUBENT K2023129 20070712 K002K202312900001 BIB 6 10 K202312900002 REACTION (79-AU-197(G,X)27-CO-56,IND,SIG,,BRA) K202312900003 DECAY-DATA (27-CO-56,77.727D,DG,846.8,0.99935) K202312900004 SAMPLE - Chemical-form of target is element. K202312900005 - Physical-form of target is solid. K202312900006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202312900007 METHOD (CHSEP) K202312900008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202312900009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202312900010 not included in tabulated errors. K202312900011 (ERR-2) Uncertainty in detector efficiency K202312900012 ENDBIB 10 0 K202312900013 COMMON 1 3 K202312900014 ERR-2 K202312900015 PER-CENT K202312900016 7. K202312900017 ENDCOMMON 3 0 K202312900018 DATA 3 1 K202312900019 EN-MAX DATA ERR-T K202312900020 MEV MICRO-B MICRO-B K202312900021 1100. 0.14 0.07 K202312900022 ENDDATA 3 0 K202312900023 ENDSUBENT 22 0 K202312999999 SUBENT K2023130 20070712 K002K202313000001 BIB 6 10 K202313000002 REACTION (79-AU-197(G,X)27-CO-57,IND,SIG,,BRA) K202313000003 DECAY-DATA (27-CO-57,271.79D,DG,122.1,0.8560) K202313000004 SAMPLE - Chemical-form of target is element. K202313000005 - Physical-form of target is solid. K202313000006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202313000007 METHOD (CHSEP) K202313000008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202313000009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202313000010 not included in tabulated errors. K202313000011 (ERR-2) Uncertainty in detector efficiency K202313000012 ENDBIB 10 0 K202313000013 COMMON 1 3 K202313000014 ERR-2 K202313000015 PER-CENT K202313000016 7. K202313000017 ENDCOMMON 3 0 K202313000018 DATA 3 4 K202313000019 EN-MAX DATA ERR-T K202313000020 MEV MICRO-B MICRO-B K202313000021 1100. 1.40 0.21 K202313000022 1000. 0.63 0.32 K202313000023 950. 1.12 0.62 K202313000024 550. 0.39 0.10 K202313000025 ENDDATA 6 0 K202313000026 ENDSUBENT 25 0 K202313099999 SUBENT K2023131 20070712 K002K202313100001 BIB 6 10 K202313100002 REACTION (79-AU-197(G,X)27-CO-58,IND,SIG,,BRA) K202313100003 DECAY-DATA (27-CO-58-G,70.82D,DG,810.8,0.99448) K202313100004 SAMPLE - Chemical-form of target is element. K202313100005 - Physical-form of target is solid. K202313100006 - Target-thickness is 3000 mg/cm**2. Typical thickness K202313100007 METHOD (CHSEP) K202313100008 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202313100009 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202313100010 not included in tabulated errors. K202313100011 (ERR-2) Uncertainty in detector efficiency K202313100012 ENDBIB 10 0 K202313100013 COMMON 1 3 K202313100014 ERR-2 K202313100015 PER-CENT K202313100016 7. K202313100017 ENDCOMMON 3 0 K202313100018 DATA 3 6 K202313100019 EN-MAX DATA ERR-T K202313100020 MEV MICRO-B MICRO-B K202313100021 1100. 3.12 0.33 K202313100022 1000. 3.46 0.48 K202313100023 950. 3.01 0.48 K202313100024 550. 1.16 0.14 K202313100025 500. 0.68 0.17 K202313100026 400. 0.64 0.23 K202313100027 ENDDATA 8 0 K202313100028 ENDSUBENT 27 0 K202313199999 SUBENT K2023132 20070712 K002K202313200001 BIB 6 11 K202313200002 REACTION (79-AU-197(G,X)27-CO-60,IND,SIG,,BRA) K202313200003 DECAY-DATA (27-CO-60-G,5.2714YR,DG,1173.2,0.9990, K202313200004 DG,1332.5,0.999820) K202313200005 SAMPLE - Chemical-form of target is element. K202313200006 - Physical-form of target is solid. K202313200007 - Target-thickness is 3000 mg/cm**2. Typical thickness K202313200008 METHOD (CHSEP) K202313200009 DETECTOR (HPGE) To perform Gamma-ray spectrometry K202313200010 ERR-ANALYS (ERR-T) Uncertainty in beam-intensity calibration is K202313200011 not included in tabulated errors. K202313200012 (ERR-2) Uncertainty in detector efficiency K202313200013 ENDBIB 11 0 K202313200014 COMMON 1 3 K202313200015 ERR-2 K202313200016 PER-CENT K202313200017 7. K202313200018 ENDCOMMON 3 0 K202313200019 DATA 3 6 K202313200020 EN-MAX DATA ERR-T K202313200021 MEV MICRO-B MICRO-B K202313200022 1100. 9.2 1.2 K202313200023 1000. 13.3 2.2 K202313200024 950. 11.3 2.7 K202313200025 550. 5.24 0.68 K202313200026 500. 5.8 1.4 K202313200027 400. 4.6 1.5 K202313200028 ENDDATA 8 0 K202313200029 ENDSUBENT 28 0 K202313299999 ENDENTRY 132 0 K202399999999