ENTRY G0514 20221206 G051400000001 SUBENT G0514001 20221206 20231011 G051400100001 BIB 13 34 G051400100002 TITLE The flux weighted cross sections of 179Hf(g,g')179mHf G051400100003 and natHf(g,x)179mHf reactions at 8 MeV and 15 MeV G051400100004 bremsstrahlung end point energies G051400100005 AUTHOR (G.T.Bholane, T.S.Ganesapandy, A.B.Phatangare, G051400100006 V.D.Bharud, B.J.Patil, S.S.Dahiwale, G051400100007 S.V.Suryanarayana, V.N.Bhoraskar, S.D.Dhole) G051400100008 INSTITUTE (3INDPOO,3INDTRM) G051400100009 (3INDIND) M.J. College, Jalgaon G051400100010 (3INDIND) Abasaheb Garware College, Pune G051400100011 REFERENCE (J,ARI,174,109739,2021) G051400100012 FACILITY (LINAC,3INDIND) medical linear accelerator at G051400100013 Dr.Vikhe Patil Memorial Hospital, Ahmednagar G051400100014 INC-SOURCE (BRST) 8 MeV and 15 MeV electron on a tungsten target. G051400100015 The electron beam of 5 uA and energy spread <0.5%. G051400100016 SAMPLE Natural HfO2 powder (300 mg, 99.99% pure) in a G051400100017 cylindrical polyethylene vial of 12 mm length and 6 mm G051400100018 inner diameter. G051400100019 Indium and gold foils (99.99% pure) of 10 mm X 10 mm G051400100020 size and 200 mg wt. were used as flux monitor. G051400100021 DETECTOR (HPGE) 1.5 keV energy resolution at 1.33 MeV. G051400100022 METHOD (ACTIV) G051400100023 CORRECTION Corrected for G051400100024 - gamma coincidence (0.1% uncertainty in cross section)G051400100025 - gamma self-absorption (0.03% uncertainty in G051400100026 cross section) G051400100027 ERR-ANALYS (DATA-ERR) The uncertainty in data are due to G051400100028 - peak area G051400100029 - photon flux G051400100030 - gamma-ray intensity G051400100031 - number of sample atoms G051400100032 - timing factor G051400100033 STATUS (APRVD) Proof-read by S.D.Dhole (2022-12-12) G051400100034 (TABLE) Table 3 of App.Radi.Isot.174(2021)109739 G051400100035 HISTORY (20221206C) VT+On G051400100036 ENDBIB 34 0 G051400100037 NOCOMMON 0 0 G051400100038 ENDSUBENT 37 0 G051400199999 SUBENT G0514002 20221206 20231011 G051400200001 BIB 4 4 G051400200002 REACTION (72-HF-179(G,INL)72-HF-179-M1,,SIG,,BRA) G051400200003 DECAY-DATA (72-HF-179-M1,18.67SEC,DG,214.3,0.9530) G051400200004 MONITOR (49-IN-115(G,INL)49-IN-115-M,,SIG,,BRA) G051400200005 DECAY-MON (49-IN-115-M,4.486HR,DG,336.2,0.459) G051400200006 ENDBIB 4 0 G051400200007 NOCOMMON 0 0 G051400200008 DATA 3 1 G051400200009 EN-MAX DATA DATA-ERR G051400200010 MEV MB MB G051400200011 8. 1.40 0.15 G051400200012 ENDDATA 3 0 G051400200013 ENDSUBENT 12 0 G051400299999 SUBENT G0514003 20221206 20231011 G051400300001 BIB 5 5 G051400300002 REACTION (72-HF-0(G,X)72-HF-179-M1,,SIG,,BRA) G051400300003 DECAY-DATA (72-HF-179-M1,18.67SEC,DG,214.3,0.9530) G051400300004 MONITOR (79-AU-197(G,N)79-AU-196,,SIG,,BRA) G051400300005 DECAY-MON (79-AU-196-G,6.1669D,DG,355.73,0.87) G051400300006 MONIT-REF (,A.I.Blokhin+,R,IAEA-TECDOC-1178,2000) G051400300007 ENDBIB 5 0 G051400300008 NOCOMMON 0 0 G051400300009 DATA 3 1 G051400300010 EN-MAX DATA DATA-ERR G051400300011 MEV MB MB G051400300012 15. 54.90 7.35 G051400300013 ENDDATA 3 0 G051400300014 ENDSUBENT 13 0 G051400399999 ENDENTRY 3 0 G051499999999