ENTRY F1232 20240216 F123200000001 SUBENT F1232001 20240216 20240513 F123200100001 BIB 10 28 F123200100002 TITLE Superasymmetric fission of heavy nuclei induced by F123200100003 intermediate-energy protons F123200100004 AUTHOR (A.Deppman,E.Andrade-II,V.Guimaraes,G.S.Karapetyan, F123200100005 O.A.P.Tavares,A.R.Balabekyan,N.A.Demekhina,J.Adam, F123200100006 F.Garcia,K.Katovsky) F123200100007 INSTITUTE (3BZLUSP,3BZLRIO,4ARMJSU,4ZZZDUB,3CZRCTI) F123200100008 (3BZLBZL) The Research Center for Radiation Sciences F123200100009 and Technologies, Brazil F123200100010 (3CZRCTI) Department of Nuclear Reactors F123200100011 REFERENCE (J,PR/C,88,064609,2013) F123200100012 #doi:10.1103/PhysRevC.88.064609 F123200100013 FACILITY (SYNCH,4ZZZDUB) LNR Phasotron U-400M Cyclotron was F123200100014 used. F123200100015 INC-SOURCE The irradiation time was 27 min and the proton beam F123200100016 intensity was about 3*10**14 protons per min. F123200100017 METHOD (ACTIV,GSPEC) F123200100018 ERR-ANALYS (ERR-T) Errors include contributions from those F123200100019 associated with the statistical significance of F123200100020 experimental results, those in measuring the target F123200100021 thickness, and those in determining the detector F123200100022 efficiency. F123200100023 (ERR-S,2.,3.) Error of experimental result. F123200100024 (ERR-1) Error of determination of target thickness. F123200100025 (ERR-2) Error of determination of detector efficiency. F123200100026 STATUS (TABLE,,A.Deppman+,J,PR/C,88,064609,2013) Table I F123200100027 (APRVD) Approved by authors. F123200100028 HISTORY (20140912C) F123200100029 (20240216A) SD: Correction in several Subents. F123200100030 ENDBIB 28 0 F123200100031 COMMON 3 3 F123200100032 EN ERR-1 ERR-2 F123200100033 MEV PER-CENT PER-CENT F123200100034 660. 3. 10. F123200100035 ENDCOMMON 3 0 F123200100036 ENDSUBENT 35 0 F123200199999 SUBENT F1232002 20140912 F055F123200200001 BIB 3 5 F123200200002 REACTION (92-U-238(P,X)ELEM/MASS,CUM,SIG) F123200200003 SAMPLE Natural uranium target of 0.164 g and 0.0487 mm thick F123200200004 was used. F123200200005 DETECTOR (HPGE) HPGe detector with the efficiency of 20% and F123200200006 energy resolution of 1.8 keV (1332 keV Co-60) was used.F123200200007 ENDBIB 5 0 F123200200008 NOCOMMON 0 0 F123200200009 DATA 5 25 F123200200010 ELEMENT MASS ISOMER DATA ERR-T F123200200011 NO-DIM NO-DIM NO-DIM MB MB F123200200012 12. 28. 0.0043 4.3E-04 F123200200013 17. 34. 1. 7.7E-04 1.5E-05 F123200200014 17. 39. 0.053 0.005 F123200200015 18. 41. 0.0037 7.4E-04 F123200200016 18. 44. 2.5E-04 F123200200017 19. 42. 0.007 7.0E-04 F123200200018 19. 43. 0.023 0.002 F123200200019 20. 47. 0.024 0.002 F123200200020 21. 43. 0.012 0.001 F123200200021 24. 49. 0.025 0.005 F123200200022 24. 51. 0.41 0.04 F123200200023 25. 56. 0.15 0.02 F123200200024 26. 59. 0.27 0.03 F123200200025 27. 55. 0.02 0.002 F123200200026 28. 57. 0.0011 1.1E-04 F123200200027 28. 65. 0.0017 1.7E-04 F123200200028 28. 66. 0.015 0.002 F123200200029 29. 60. 0.006 F123200200030 29. 61. 0.04 0.004 F123200200031 29. 67. 0.55 0.06 F123200200032 30. 69. 1. 0.041 0.004 F123200200033 31. 65. 0.02 F123200200034 31. 67. 0.06 0.006 F123200200035 32. 66. 0.003 F123200200036 32. 69. 0.03 0.003 F123200200037 ENDDATA 27 0 F123200200038 ENDSUBENT 37 0 F123200299999 SUBENT F1232003 20240216 20240513 F123200300001 BIB 4 6 F123200300002 REACTION (92-U-238(P,X)27-CO-60,CUM,SIG) F123200300003 SAMPLE Natural uranium target of 0.164 g and 0.0487 mm thick F123200300004 was used. F123200300005 DETECTOR (HPGE) HPGe detector with the efficiency of 20% and F123200300006 energy resolution of 1.8 keV (1332 keV Co-60) was used.F123200300007 HISTORY (20240216A) SD: SF4=Co-60g+m1 -> Co-60 in REACTION codeF123200300008 ENDBIB 6 0 F123200300009 NOCOMMON 0 0 F123200300010 DATA 2 1 F123200300011 DATA ERR-T F123200300012 MB MB F123200300013 0.33 0.03 F123200300014 ENDDATA 3 0 F123200300015 ENDSUBENT 14 0 F123200399999 SUBENT F1232004 20240216 20240513 F123200400001 BIB 4 6 F123200400002 REACTION (92-U-238(P,X)ELEM/MASS,,SIG) F123200400003 SAMPLE Natural uranium target of 0.164 g and 0.0487 mm thick F123200400004 was used. F123200400005 DETECTOR (HPGE) HPGe detector with the efficiency of 20% and F123200400006 energy resolution of 1.8 keV (1332 keV Co-60) was used.F123200400007 HISTORY (20240216A) SD: SF5=IND deleted from REACTION code. F123200400008 ENDBIB 6 0 F123200400009 NOCOMMON 0 0 F123200400010 DATA 5 18 F123200400011 ELEMENT MASS ISOMER DATA ERR-T F123200400012 NO-DIM NO-DIM NO-DIM MB MB F123200400013 16. 38. 0.007 1.4E-04 F123200400014 17. 38. 0. 0.04 0.008 F123200400015 19. 44. 0.031 5.0E-05 F123200400016 21. 44. 0. 0.0025 F123200400017 21. 44. 1. 0.065 0.007 F123200400018 21. 47. 0.17 0.02 F123200400019 21. 48. 0.044 0.004 F123200400020 23. 48. 0.022 0.002 F123200400021 24. 48. 0.0014 F123200400022 25. 52. 0. 0.0015 1.5E-04 F123200400023 25. 52. 1. 0.0085 8.5E-04 F123200400024 25. 54. 0.11 0.01 F123200400025 26. 52. 0. 6.5E-04 5.5E-05 F123200400026 27. 56. 0.07 0.01 F123200400027 27. 57. 0.059 0.006 F123200400028 28. 56. 0.002 F123200400029 30. 65. 0.10 0.01 F123200400030 31. 66. 0.051 0.005 F123200400031 ENDDATA 20 0 F123200400032 ENDSUBENT 31 0 F123200499999 SUBENT F1232005 20240216 20240513 F123200500001 BIB 4 7 F123200500002 REACTION (92-U-238(P,X)21-SC-46,,SIG) F123200500003 SAMPLE Natural uranium target of 0.164 g and 0.0487 mm thick F123200500004 was used. F123200500005 DETECTOR (HPGE) HPGe detector with the efficiency of 20% and F123200500006 energy resolution of 1.8 keV (1332 keV Co-60) was used.F123200500007 HISTORY (20240216A) SD: SF4=Sc-46g+m1 -> Sc-46; SF5=IND deletedF123200500008 from REACTION code. F123200500009 ENDBIB 7 0 F123200500010 NOCOMMON 0 0 F123200500011 DATA 2 1 F123200500012 DATA ERR-T F123200500013 MB MB F123200500014 0.036 0.004 F123200500015 ENDDATA 3 0 F123200500016 ENDSUBENT 15 0 F123200599999 SUBENT F1232006 20240216 20240513 F123200600001 BIB 4 7 F123200600002 REACTION (92-U-238(P,X)27-CO-58,,SIG) F123200600003 SAMPLE Natural uranium target of 0.164 g and 0.0487 mm thick F123200600004 was used. F123200600005 DETECTOR (HPGE) HPGe detector with the efficiency of 20% and F123200600006 energy resolution of 1.8 keV (1332 keV Co-60) was used.F123200600007 HISTORY (20240216A) SD: SF4=Co-58g+m1 -> Co-58; SF5=IND deletedF123200600008 from REACTION code. F123200600009 ENDBIB 7 0 F123200600010 NOCOMMON 0 0 F123200600011 DATA 2 1 F123200600012 DATA ERR-T F123200600013 MB MB F123200600014 0.17 0.02 F123200600015 ENDDATA 3 0 F123200600016 ENDSUBENT 15 0 F123200699999 SUBENT F1232007 20140912 F055F123200700001 BIB 3 5 F123200700002 REACTION (93-NP-237(P,X)ELEM/MASS,CUM,SIG) F123200700003 SAMPLE Neptunium target of 0.742 g and 0.193 mm thick was F123200700004 used. F123200700005 DETECTOR (GELI) Ge(Li) detector with efficiency of 4.8% and F123200700006 energy resolution of 2.6 keV (1332 Co-60) was used. F123200700007 ENDBIB 5 0 F123200700008 NOCOMMON 0 0 F123200700009 DATA 5 26 F123200700010 ELEMENT MASS ISOMER DATA ERR-T F123200700011 NO-DIM NO-DIM NO-DIM MB MB F123200700012 12. 28. 0.186 0.020 F123200700013 17. 34. 1. 0.08 0.02 F123200700014 17. 39. 0.023 0.003 F123200700015 18. 41. 0.73 0.07 F123200700016 18. 44. 0.089 0.02 F123200700017 19. 42. 0.40 F123200700018 19. 43. 0.45 0.06 F123200700019 19. 45. 0.24 0.05 F123200700020 20. 47. 0.067 F123200700021 21. 43. 0.23 0.02 F123200700022 24. 49. 0.073 0.015 F123200700023 24. 51. 0.20 0.02 F123200700024 25. 56. 0.69 0.07 F123200700025 26. 59. 1.21 0.12 F123200700026 27. 55. 0.036 F123200700027 28. 57. 0.01 F123200700028 28. 65. 0.04 F123200700029 28. 66. 0.20 0.05 F123200700030 29. 60. 0.053 F123200700031 29. 61. 0.057 F123200700032 29. 67. 2.10 0.21 F123200700033 30. 69. 1. 0.80 0.16 F123200700034 31. 65. 0.043 F123200700035 31. 67. 0.20 0.02 F123200700036 32. 66. 0.13 F123200700037 32. 69. 0.051 0.012 F123200700038 ENDDATA 28 0 F123200700039 ENDSUBENT 38 0 F123200799999 SUBENT F1232008 20240216 20240513 F123200800001 BIB 4 6 F123200800002 REACTION (93-NP-237(P,X)27-CO-60,CUM,SIG) F123200800003 SAMPLE Neptunium target of 0.742 g and 0.193 mm thick was F123200800004 used. F123200800005 DETECTOR (GELI) Ge(Li) detector with efficiency of 4.8% and F123200800006 energy resolution of 2.6 keV (1332 Co-60) was used. F123200800007 HISTORY (20240216A) SD: SF4=Co-60g+m1 -> Co-60 in REACTION codeF123200800008 ENDBIB 6 0 F123200800009 NOCOMMON 0 0 F123200800010 DATA 2 1 F123200800011 DATA ERR-T F123200800012 MB MB F123200800013 1.70 0.20 F123200800014 ENDDATA 3 0 F123200800015 ENDSUBENT 14 0 F123200899999 SUBENT F1232009 20240216 20240513 F123200900001 BIB 4 6 F123200900002 REACTION (93-NP-237(P,X)ELEM/MASS,,SIG) F123200900003 SAMPLE Neptunium target of 0.742 g and 0.193 mm thick was F123200900004 used. F123200900005 DETECTOR (GELI) Ge(Li) detector with efficiency of 4.8% and F123200900006 energy resolution of 2.6 keV (1332 Co-60) was used. F123200900007 HISTORY (20240216A) SD: SF5=IND deleted from REACTION code. F123200900008 ENDBIB 6 0 F123200900009 NOCOMMON 0 0 F123200900010 DATA 5 18 F123200900011 ELEMENT MASS ISOMER DATA ERR-T F123200900012 NO-DIM NO-DIM NO-DIM MB MB F123200900013 16. 38. 0.08 F123200900014 17. 38. 0. 0.28 F123200900015 19. 44. 0.22 0.04 F123200900016 21. 44. 0. 0.15 F123200900017 21. 44. 1. 0.12 0.01 F123200900018 21. 47. 0.63 0.06 F123200900019 21. 48. 0.42 0.04 F123200900020 23. 48. 0.48 0.05 F123200900021 24. 48. 0.01 0.001 F123200900022 25. 52. 0. 0.077 0.008 F123200900023 25. 52. 1. 0.205 0.03 F123200900024 25. 54. 0.28 0.03 F123200900025 26. 52. 0. 0.01 0.01 F123200900026 27. 56. 0.03 0.006 F123200900027 27. 57. 0.20 0.02 F123200900028 28. 56. 0.007 F123200900029 30. 65. 0.87 0.17 F123200900030 31. 66. 0.084 F123200900031 ENDDATA 20 0 F123200900032 ENDSUBENT 31 0 F123200999999 SUBENT F1232010 20240216 20240513 F123201000001 BIB 4 7 F123201000002 REACTION (93-NP-237(P,X)21-SC-46,,SIG) F123201000003 SAMPLE Neptunium target of 0.742 g and 0.193 mm thick was F123201000004 used. F123201000005 DETECTOR (GELI) Ge(Li) detector with efficiency of 4.8% and F123201000006 energy resolution of 2.6 keV (1332 Co-60) was used. F123201000007 HISTORY (20240216A) SD: SF4=Sc-46g+m1 -> Sc-46; SF5=IND deletedF123201000008 from REACTION code. F123201000009 ENDBIB 7 0 F123201000010 NOCOMMON 0 0 F123201000011 DATA 2 1 F123201000012 DATA ERR-T F123201000013 MB MB F123201000014 0.94 0.09 F123201000015 ENDDATA 3 0 F123201000016 ENDSUBENT 15 0 F123201099999 SUBENT F1232011 20240216 20240513 F123201100001 BIB 4 7 F123201100002 REACTION (93-NP-237(P,X)27-CO-58,,SIG) F123201100003 SAMPLE Neptunium target of 0.742 g and 0.193 mm thick was F123201100004 used. F123201100005 DETECTOR (GELI) Ge(Li) detector with efficiency of 4.8% and F123201100006 energy resolution of 2.6 keV (1332 Co-60) was used. F123201100007 HISTORY (20240216A) SD: SF4=Co-58g+m1 -> Co-58; SF5=IND deletedF123201100008 from REACTION code. F123201100009 ENDBIB 7 0 F123201100010 NOCOMMON 0 0 F123201100011 DATA 2 1 F123201100012 DATA ERR-T F123201100013 MB MB F123201100014 0.13 0.02 F123201100015 ENDDATA 3 0 F123201100016 ENDSUBENT 15 0 F123201199999 ENDENTRY 9 0 F123299999999