ENTRY D6389 20210331 D130D638900000001 SUBENT D6389001 20210331 D130D638900100001 BIB 12 31 D638900100002 TITLE Role of neutron transfer in sub-barrier fusion D638900100003 AUTHOR (R.N.Sahoo, M.Kaushik, A.Sood, A.Sharma, S.Thakur, D638900100004 P.Kumar, M.M.Shaikh, R.Biswas, A.Yadav, M.K.Sharma, D638900100005 J.Gehlot, S.Nath, N.Madhavan, R.G.Pillay, E.M.Kozulin,D638900100006 G.N.Knyazheva, K.V.Novikov, P.P.Singh) D638900100007 INSTITUTE (3INDIIR,3INDVEC,3INDNSD,4ZZZDUB) D638900100008 (3INDIND) Jamia Millia Islamia, New Delhi D638900100009 (3INDIND) S. V. College, Aligarh, Uttar Pradesh D638900100010 REFERENCE (J,PR/C,102,024615,2020) D638900100011 REL-REF (I,D6360001,R.N.Sahoo+,J,PR/C,99,024607,2019) D638900100012 For experimental details D638900100013 FACILITY (VDGT,3INDNSD) 15UD Pelletron accelerator D638900100014 DETECTOR (SIBAR) Two silicon surface barrier detectors each D638900100015 having 1 mm diameter aperture were mounted at 9.8 cm D638900100016 distance from the beam interaction point on the D638900100017 target foil subtending an angle of +/-15.5 degree are D638900100018 used to detect elastically scattered particles from D638900100019 the target. D638900100020 (MAGSP,MWPC) A multiwire proportional counter, with D638900100021 an active area of 150 x 50 mm2 was placed at the D638900100022 focal plane of Heavy Ion Reaction Analyser to detect D638900100023 the evaporation residues. D638900100024 METHOD (TOF) Delta E-TOF for evaporation residue selection. D638900100025 (ASEP) Fusion cross-sections were measured using the D638900100026 Heavy Ion Reaction Analyzer (HIRA). D638900100027 ERR-ANALYS (DATA-ERR) The errors presented are absolute errors D638900100028 consisting of statistical error and the error due to D638900100029 transmission efficiency of the recoil mass separator. D638900100030 ANALYSIS (NTRTH) D638900100031 STATUS (TABLE) Table I of Phys. Rev. C 102 (2020) 024615 D638900100032 HISTORY (20210331C) VT D638900100033 ENDBIB 31 0 D638900100034 NOCOMMON 0 0 D638900100035 ENDSUBENT 34 0 D638900199999 SUBENT D6389002 20210331 D130D638900200001 BIB 2 4 D638900200002 REACTION (52-TE-130(17-CL-35,FUS),,SIG,ER) D638900200003 SAMPLE The target 130Te of thickness ~ 200 ug/cm2, fabricated D638900200004 on a carbon backing of 20 ug/cm2 using vacuum D638900200005 evaporation technique. D638900200006 ENDBIB 4 0 D638900200007 NOCOMMON 0 0 D638900200008 DATA 3 16 D638900200009 EN-CM DATA DATA-ERR D638900200010 MEV MB MB D638900200011 94.0 0.034 0.010 D638900200012 95.6 0.243 0.045 D638900200013 97.2 1.37 0.17 D638900200014 98.8 4.5 0.6 D638900200015 100.3 15.6 1.8 D638900200016 101.9 40.2 4.5 D638900200017 103.5 71. 8. D638900200018 105.0 111. 13. D638900200019 106.7 174. 21. D638900200020 108.2 225. 26. D638900200021 109.8 286. 33. D638900200022 112.2 397. 46. D638900200023 114.5 466. 60. D638900200024 116.9 548. 70. D638900200025 119.3 598. 72. D638900200026 121.6 659. 83. D638900200027 ENDDATA 18 0 D638900200028 ENDSUBENT 27 0 D638900299999 ENDENTRY 2 0 D638999999999