ENTRY D6337 20191113 D124D633700000001 SUBENT D6337001 20191113 D124D633700100001 BIB 11 39 D633700100002 TITLE Investigation of complete and incomplete fusion in D633700100003 the 7Li + 124Sn reaction near coulomb barrier energies D633700100004 AUTHOR (V.V.Parkar, S.K.Sharma, R.Palit, S.Upadhyaya, D633700100005 A.Shrivastava, S.K.Pandit, K.Mahata, V.Jha, S.Santra, D633700100006 K.Ramachandran, T.N.Nag, P.K.Rath, B.Kanagalekar, D633700100007 T.Trivedi) D633700100008 INSTITUTE (3INDTRM,3INDTAT,3INDMNP) D633700100009 (3INDIND) Amity University, Noida D633700100010 (3INDIND) Homi Bhabha National Institute, Mumbai D633700100011 (3INDIND) Rani Channamma University, Belagavi D633700100012 (3INDIND) Guru Ghasidas Vishwavidyalaya, Bilaspur D633700100013 REFERENCE (J,PR/C,97,014607,2018) D633700100014 FACILITY (VDGT,3INDTAT) 14UD BARC-TIFR Pelletron-Linac D633700100015 accelerator D633700100016 SAMPLE 124Sn target of thickness 2.47 +/- 0.4 mg/cm2 used D633700100017 for online gamma measurement. D633700100018 124Sn having thickness in the range of 1.5-4.0 mg/cm2 D633700100019 for offline gamma measurement. D633700100020 DETECTOR (GE) Two Compton suppressed clover detectors were D633700100021 placed at a distance of 25 cm from the target center, D633700100022 one at 125 deg, for absolute cross-section estimation D633700100023 of various reaction channels, and the other at 90 deg, D633700100024 for identification of unshifted gamma lines. D633700100025 (SI) A monitor detector (=500 um) was placed at 30 D633700100026 deg. It was used in the ER cross section estimation D633700100027 using measured elastic (Rutherford) scattering cross D633700100028 section. D633700100029 (HPGE) The off-line gamma ray counting was done using D633700100030 HPGe detector. The energy calibration and efficiency D633700100031 of the detector were measured by calibrated D633700100032 radioactive 152Eu, 133Ba and 241Am sources. D633700100033 CORRECTION The beam energies were corrected for the loss at half D633700100034 the target thickness D633700100035 ERR-ANALYS (DATA-ERR) In off-line gamma-ray measurements the D633700100036 systematic uncertainties arises due to beam current, D633700100037 target thickness, detector efficiency and extraction ofD633700100038 gamma-ray yield. D633700100039 STATUS (TABLE) Table III of Phys. Rev. C, 97 (2018) 014607 D633700100040 HISTORY (20191113C) Devesh Raj D633700100041 ENDBIB 39 0 D633700100042 NOCOMMON 0 0 D633700100043 ENDSUBENT 42 0 D633700199999 SUBENT D6337002 20191113 D124D633700200001 BIB 1 1 D633700200002 REACTION (50-SN-124(3-LI-7,X)52-TE-127,,SIG) D633700200003 ENDBIB 1 0 D633700200004 NOCOMMON 0 0 D633700200005 DATA 3 17 D633700200006 EN DATA DATA-ERR D633700200007 MEV MB MB D633700200008 22.5 0.55 0.16 D633700200009 23.5 3.05 0.88 D633700200010 24.5 6.68 1.53 D633700200011 25.5 10.4 4.0 D633700200012 26.6 11.3 2.5 D633700200013 27.6 16.1 2.2 D633700200014 28.6 17.0 2.2 D633700200015 29.6 19.0 0.7 D633700200016 30.6 20.2 1.4 D633700200017 31.6 23.3 2.4 D633700200018 32.6 24.1 3.1 D633700200019 33.6 24.7 2.1 D633700200020 34.6 24.3 1.6 D633700200021 35.6 28.3 1.9 D633700200022 36.6 30.5 2.3 D633700200023 37.6 26.9 3.8 D633700200024 38.7 28.3 2.1 D633700200025 ENDDATA 19 0 D633700200026 ENDSUBENT 25 0 D633700299999 SUBENT D6337003 20191113 D124D633700300001 BIB 2 4 D633700300002 REACTION (50-SN-124(3-LI-7,X)52-TE-127-G,(CUM),SIG) D633700300003 METHOD (ACTIV) The target and catcher foil assemblies were D633700300004 irradiated for 7-18 hours. The beam current was D633700300005 ~10-80 nA. D633700300006 ENDBIB 4 0 D633700300007 NOCOMMON 0 0 D633700300008 DATA 3 4 D633700300009 EN DATA DATA-ERR D633700300010 MEV MB MB D633700300011 24.5 6.68 1.53 D633700300012 28.6 17.0 2.2 D633700300013 32.6 24.1 3.1 D633700300014 35.6 28.3 1.9 D633700300015 ENDDATA 6 0 D633700300016 ENDSUBENT 15 0 D633700399999 SUBENT D6337004 20191113 D124D633700400001 BIB 1 1 D633700400002 REACTION (50-SN-124(3-LI-7,X)52-TE-126,,SIG) D633700400003 ENDBIB 1 0 D633700400004 NOCOMMON 0 0 D633700400005 DATA 3 14 D633700400006 EN DATA DATA-ERR D633700400007 MEV MB MB D633700400008 25.5 3.50 0.96 D633700400009 26.6 7.96 1.53 D633700400010 27.6 9.87 2.73 D633700400011 28.6 12.5 2.9 D633700400012 29.6 13.3 3.1 D633700400013 30.6 15.2 2.9 D633700400014 31.6 18.4 3.8 D633700400015 32.6 21.6 3.8 D633700400016 33.6 24.5 3.9 D633700400017 34.6 24.4 3.8 D633700400018 35.6 26.3 4.3 D633700400019 36.6 30.4 4.6 D633700400020 37.6 28.0 3.5 D633700400021 38.7 29.2 4.2 D633700400022 ENDDATA 16 0 D633700400023 ENDSUBENT 22 0 D633700499999 SUBENT D6337005 20191116 D124D633700500001 BIB 3 9 D633700500002 REACTION (50-SN-124(3-LI-7,X)51-SB-126-M1,,SIG) D633700500003 DECAY-DATA (51-SB-126-M1,19.15MIN,DG,414.5,0.860, D633700500004 DG,666.1,0.860, D633700500005 DG,694.8,0.820, D633700500006 DG,928.2,0.013, D633700500007 DG,1034.9,0.018) D633700500008 METHOD (ACTIV) The target and catcher foil assemblies were D633700500009 irradiated for 7-18 hours. The beam current was D633700500010 ~10-80 nA. D633700500011 ENDBIB 9 0 D633700500012 NOCOMMON 0 0 D633700500013 DATA 3 6 D633700500014 EN DATA DATA-ERR D633700500015 MEV MB MB D633700500016 18.4 5.34 0.5 D633700500017 21.5 20.5 1.0 D633700500018 24.5 32.1 1.9 D633700500019 28.6 29.7 1.6 D633700500020 32.6 22.9 1.3 D633700500021 35.6 19.9 1.5 D633700500022 ENDDATA 8 0 D633700500023 ENDSUBENT 22 0 D633700599999 SUBENT D6337006 20191116 D124D633700600001 BIB 3 12 D633700600002 REACTION (50-SN-124(3-LI-7,X)51-SB-126-G,M+,SIG) D633700600003 DECAY-DATA (51-SB-126-G,12.35D,DG,414.7,0.833, D633700600004 DG,573.9,0.067, D633700600005 DG,593.2,0.075, D633700600006 DG,666.5,0.996, D633700600007 DG,695.0,0.996, D633700600008 DG,697.0,0.290, D633700600009 DG,720.7,0.538, D633700600010 DG,856.8,0.176) D633700600011 METHOD (ACTIV) The target and catcher foil assemblies were D633700600012 irradiated for 7-18 hours. The beam current was D633700600013 ~10-80 nA. D633700600014 ENDBIB 12 0 D633700600015 NOCOMMON 0 0 D633700600016 DATA 3 6 D633700600017 EN DATA DATA-ERR D633700600018 MEV MB MB D633700600019 18.4 2.28 0.2 D633700600020 21.5 14.4 1.2 D633700600021 24.5 18.3 1.5 D633700600022 28.6 20.6 1.6 D633700600023 32.6 18.4 1.4 D633700600024 35.6 16.7 1.5 D633700600025 ENDDATA 8 0 D633700600026 ENDSUBENT 25 0 D633700699999 SUBENT D6337007 20191116 D124D633700700001 BIB 3 8 D633700700002 REACTION (50-SN-124(3-LI-7,X)51-SB-125,(CUM),SIG) D633700700003 DECAY-DATA (51-SB-125,2.76YR,DG,427.9,0.296, D633700700004 DG,463.4,0.105, D633700700005 DG,600.6,0.177, D633700700006 DG,636.0,0.112) D633700700007 METHOD (ACTIV) The target and catcher foil assemblies were D633700700008 irradiated for 7-18 hours. The beam current was D633700700009 ~10-80 nA. D633700700010 ENDBIB 8 0 D633700700011 NOCOMMON 0 0 D633700700012 DATA 3 6 D633700700013 EN DATA DATA-ERR D633700700014 MEV MB MB D633700700015 18.4 11.8 1.7 D633700700016 21.5 77.0 3.4 D633700700017 24.5 172. 41. D633700700018 28.6 203. 56. D633700700019 32.6 279. 29. D633700700020 35.6 316. 22. D633700700021 ENDDATA 8 0 D633700700022 ENDSUBENT 21 0 D633700799999 SUBENT D6337008 20191116 D124D633700800001 BIB 3 6 D633700800002 REACTION (50-SN-124(3-LI-7,X)51-SB-124-G,M+,SIG) D633700800003 DECAY-DATA (51-SB-124-G,60.20D,DG,602.7,0.978, D633700800004 DG,1691.0,0.476) D633700800005 METHOD (ACTIV) The target and catcher foil assemblies were D633700800006 irradiated for 7-18 hours. The beam current was D633700800007 ~10-80 nA. D633700800008 ENDBIB 6 0 D633700800009 NOCOMMON 0 0 D633700800010 DATA 3 6 D633700800011 EN DATA DATA-ERR D633700800012 MEV MB MB D633700800013 18.4 0.33 0.03 D633700800014 21.5 2.24 0.11 D633700800015 24.5 8.10 1.02 D633700800016 28.6 15.7 1.1 D633700800017 32.6 23.6 1.8 D633700800018 35.6 46.9 2.6 D633700800019 ENDDATA 8 0 D633700800020 ENDSUBENT 19 0 D633700899999 SUBENT D6337009 20191116 D124D633700900001 BIB 3 8 D633700900002 REACTION (50-SN-124(3-LI-7,X)50-SN-125-G,(CUM),SIG) D633700900003 DECAY-DATA (50-SN-125-G,9.64D,DG,822.5,0.043, D633700900004 DG,915.6,0.041, D633700900005 DG,1067.1,0.100, D633700900006 DG,1089.2,0.046) D633700900007 METHOD (ACTIV) The target and catcher foil assemblies were D633700900008 irradiated for 7-18 hours. The beam current was D633700900009 ~10-80 nA. D633700900010 ENDBIB 8 0 D633700900011 NOCOMMON 0 0 D633700900012 DATA 3 6 D633700900013 EN DATA DATA-ERR D633700900014 MEV MB MB D633700900015 18.4 0.23 0.02 D633700900016 21.5 2.13 0.18 D633700900017 24.5 8.54 2.62 D633700900018 28.6 13.1 2.6 D633700900019 32.6 22.5 1.3 D633700900020 35.6 25.2 1.6 D633700900021 ENDDATA 8 0 D633700900022 ENDSUBENT 21 0 D633700999999 SUBENT D6337010 20191116 D124D633701000001 BIB 3 5 D633701000002 REACTION (50-SN-124(3-LI-7,X)50-SN-125-M,(CUM),SIG) D633701000003 DECAY-DATA (50-SN-125-M,9.52MIN,DG,331.9,0.973) D633701000004 METHOD (ACTIV) The target and catcher foil assemblies were D633701000005 irradiated for 7-18 hours. The beam current was D633701000006 ~10-80 nA. D633701000007 ENDBIB 5 0 D633701000008 NOCOMMON 0 0 D633701000009 DATA 3 6 D633701000010 EN DATA DATA-ERR D633701000011 MEV MB MB D633701000012 18.4 1.18 0.16 D633701000013 21.5 4.95 0.05 D633701000014 24.5 12.0 0.9 D633701000015 28.6 17.3 1.7 D633701000016 32.6 20.8 1.3 D633701000017 35.6 24.6 1.8 D633701000018 ENDDATA 8 0 D633701000019 ENDSUBENT 18 0 D633701099999 SUBENT D6337011 20191116 D124D633701100001 BIB 3 5 D633701100002 REACTION (50-SN-124(3-LI-7,X)50-SN-123-M,(CUM),SIG) D633701100003 DECAY-DATA (50-SN-123-M,40.06MIN,DG,160.3,0.857) D633701100004 METHOD (ACTIV) The target and catcher foil assemblies were D633701100005 irradiated for 7-18 hours. The beam current was D633701100006 ~10-80 nA. D633701100007 ENDBIB 5 0 D633701100008 NOCOMMON 0 0 D633701100009 DATA 3 6 D633701100010 EN DATA DATA-ERR D633701100011 MEV MB MB D633701100012 18.4 0.17 0.01 D633701100013 21.5 1.11 0.01 D633701100014 24.5 5.56 0.34 D633701100015 28.6 6.42 1.12 D633701100016 32.6 8.18 1.05 D633701100017 35.6 17.0 1.2 D633701100018 ENDDATA 8 0 D633701100019 ENDSUBENT 18 0 D633701199999 ENDENTRY 11 0 D633799999999