ENTRY D6333 20210929 D132D633300000001 SUBENT D6333001 20210929 D132D633300100001 BIB 14 42 D633300100002 TITLE Measurement of cross-sections for the 93Nb(p,n)93mMo D633300100003 and 93Nb(p,pn)92mNb reactions up to ~20 MeV energy D633300100004 AUTHOR (B.Lawriniang, R.Ghosh, S.Badwar, V.Vansola, D633300100005 Y.Santhi Sheela, S.V.Suryanarayana, H.Naik, Y.P.Naik, D633300100006 B.Jyrwa) D633300100007 INSTITUTE (3INDNEH,3INDBDA,3INDMNP,3INDTRM) D633300100008 REFERENCE (J,NP/A,973,79,2018) D633300100009 FACILITY (VDGT,3INDTRM) 14UD BARC-TIFR Pelletron facility D633300100010 SAMPLE Niobium foils (high purity >99.99%) of thickness 91 D633300100011 um. D633300100012 Copper foils (high purity >99.99%) of thickness D633300100013 103 um. D633300100014 The size of the niobium foils were 0.7 X 0.7 cm2, D633300100015 whereas the copper foils were 0.8 X 0.8 cm2. D633300100016 The thickness of Al foil was ~108 um. D633300100017 DETECTOR (HPGE) HPGe detector connected to a PC-based 4K channelD633300100018 analyzer. D633300100019 The energy resolutions of the detectors were 1.8 keV atD633300100020 the 1332.5 keV gamma-ray of 60Co. D633300100021 METHOD (ACTIV,STTA) The stack of the foils was irradiated D633300100022 with proton beam of 20 MeV for 30 minutes at beam D633300100023 current of 50 nA. D633300100024 The cooling time for niobium foil was 7.88 hours and D633300100025 for copper foils was 8.35 hours. D633300100026 MONITOR (29-CU-0(P,X)30-ZN-62,,SIG) D633300100027 DECAY-MON (30-ZN-62,9.186HR,DG,548.35,0.153, D633300100028 DG,596.56,0.260) D633300100029 MONIT-REF (,F.Tarkanyi+,R,IAEA-TECDOC-1211,2001) D633300100030 ERR-ANALYS (DATA-ERR) Uncertainty due to replicate measurements D633300100031 (ERR-T,6.5,20.4) Overall uncertainty (6.5-20.4%) from D633300100032 (ERR-S,2.1,3.7) Statistical uncertainty in counting D633300100033 statistics estimated (2.1-3.7%) D633300100034 (ERR-SYS,6.1,20.1) The systematic errors (~ 6.1-20.1%) D633300100035 (ERR-1,4.4,19.6) Proton flux estimation (~4.4-19.6%) D633300100036 (ERR-2) Irradiation time (~ 0.5%) D633300100037 (ERR-3) Detector efficiency calibration (~ 3.7%) D633300100038 (ERR-4) Half life of reaction products and gamma-ray D633300100039 abundance (~ 2%) D633300100040 (ERR-5,,5.) dead time of detector (<5%) D633300100041 STATUS (TABLE) Table 2 of Nucl. Phys. A 973 (2019) 79 D633300100042 HISTORY (20191219C) VT D633300100043 (20210924A) VS. EN-NRM=8.60 MeV added in COMMON D633300100044 ENDBIB 42 0 D633300100045 COMMON 5 3 D633300100046 EN-NRM MONIT ERR-2 ERR-3 ERR-4 D633300100047 MEV MB PER-CENT PER-CENT PER-CENT D633300100048 8.60 37.25 0.5 3.7 2. D633300100049 ENDCOMMON 3 0 D633300100050 ENDSUBENT 49 0 D633300199999 SUBENT D6333002 20191219 D124D633300200001 BIB 2 3 D633300200002 REACTION (41-NB-93(P,N)42-MO-93-M,,SIG) D633300200003 DECAY-DATA (42-MO-93-M,6.85HR,DG,263.05,0.574, D633300200004 DG,684.69,0.999) D633300200005 ENDBIB 3 0 D633300200006 NOCOMMON 0 0 D633300200007 DATA 4 4 D633300200008 EN EN-RSL DATA DATA-ERR D633300200009 MEV MEV MB MB D633300200010 8.60 1.07 6.50 0.46 D633300200011 12.54 0.70 24.07 0.49 D633300200012 15.79 0.61 12.73 0.95 D633300200013 18.63 0.53 5.43 0.42 D633300200014 ENDDATA 6 0 D633300200015 ENDSUBENT 14 0 D633300299999 SUBENT D6333003 20191219 D124D633300300001 BIB 2 2 D633300300002 REACTION (41-NB-93(P,X)41-NB-92-M,,SIG) D633300300003 DECAY-DATA (41-NB-92-M,10.15D,DG,934.44,0.9915) D633300300004 ENDBIB 2 0 D633300300005 NOCOMMON 0 0 D633300300006 DATA 4 3 D633300300007 EN EN-RSL DATA DATA-ERR D633300300008 MEV MEV MB MB D633300300009 12.54 0.70 2.00 0.63 D633300300010 15.79 0.61 30.32 1.44 D633300300011 18.63 0.53 64.74 1.98 D633300300012 ENDDATA 5 0 D633300300013 ENDSUBENT 12 0 D633300399999 ENDENTRY 3 0 D633399999999