ENTRY D6320 20190107 D119D632000000001 SUBENT D6320001 20190107 D119D632000100001 BIB 10 41 D632000100002 TITLE Evaporation residue cross-section measurements for D632000100003 48Ti-induced reactions D632000100004 AUTHOR (Priya Sharma, B.R.Behera, Ruchi Mahajan, Meenu Thakur,D632000100005 Gurpreet Kaur, Kushal Kapoor, Kavita Rani, N.Madhavan, D632000100006 S.Nath, J.Gehlot, R.Dubey, I.Mazumdar, S.M.Patel, D632000100007 M.Dhibar, M.M.Hosamani, Khushboo, Neeraj Kumar, D632000100008 A.Shamlath, G.Mohanto, Santanu Pal) D632000100009 INSTITUTE (3INDPUC,3INDNSD,3INDTAT,3INDKUD,3INDDLH,3INDTRM) D632000100010 (3INDIND) Indian Institute of Technology, Roorkee D632000100011 (3INDIND) Central University of Kerala, Kasaragod D632000100012 (3INDIND) CS-6/1 Golf Green, Kolkata D632000100013 REFERENCE (J,PR/C,96,034613,2017) D632000100014 FACILITY (VDGT,3INDNSD) 15UD Pelletron + LINAC accelerator. D632000100015 SAMPLE The samples are sandwiched between two thin carbon D632000100016 layers of thickness 25 and 7 ug/cm2. Evaporation D632000100017 residue cross-section measurements were carried out D632000100018 using pulsed 48Ti beam with 1 us pulse separation at D632000100019 energies in the center of mass from 140 to 205 MeV, D632000100020 including energy loss from 650 ug/cm2 carbon window D632000100021 foil, carbon backing, and a half thickness of target D632000100022 ~17 MeV. The average current is 0.5 pnA. D632000100023 DETECTOR (SIBAR) Two silicon surface barrier detectors were D632000100024 placed inside the target chamber at a distance of 45 D632000100025 mm from the target ladder subtended an angle of +-25 D632000100026 degree with respect to the beam direction. The D632000100027 detector was used for detection of elastically D632000100028 scattered particles for normalization. D632000100029 (MAGSP,MWPC) Position-sensitive multiwire proportional D632000100030 counter of dimensions 6 X 6 in2 followed by a strip D632000100031 detector of dimensions 6 X 6 cm2 kept in the focal D632000100032 plane chamber. The MWPC counts were used for the D632000100033 measurement of the ER cross section. D632000100034 METHOD (ASEP) The heavy evaporation residues formed were D632000100035 separated from the enormous beam background using the D632000100036 gas-filled mode of hybrid recoil mass analyzer (HYRA). D632000100037 (TOF) Evaporation residue events were selected by the D632000100038 combination of TOF and delta-E. D632000100039 ERR-ANALYS (DATA-ERR) The estimated error constituting the D632000100040 systematic error and statistical error is 15% of the D632000100041 cross section. D632000100042 HISTORY (20190107C) Imranpasha and Dr.B.Rudraswamy D632000100043 ENDBIB 41 0 D632000100044 NOCOMMON 0 0 D632000100045 ENDSUBENT 44 0 D632000199999 SUBENT D6320002 20190107 D119D632000200001 BIB 3 3 D632000200002 REACTION (60-ND-142(22-TI-48,FUS),,SIG,ER) D632000200003 SAMPLE (60-ND-142,ENR=0.9826) Target-thickness 100 ug/cm2. D632000200004 STATUS (TABLE) Table IV of Phys. Rev. C 96 (2017) 034613 D632000200005 ENDBIB 3 0 D632000200006 NOCOMMON 0 0 D632000200007 DATA 3 11 D632000200008 EN-CM DATA DATA-ERR D632000200009 MEV MB MB D632000200010 140.43 11.35 1.72 D632000200011 144.29 12.70 1.91 D632000200012 148.15 12.91 1.95 D632000200013 152.01 12.01 1.82 D632000200014 155.87 10.80 1.64 D632000200015 159.72 11.80 1.78 D632000200016 167.42 12.54 2.52 D632000200017 175.13 10.30 1.55 D632000200018 182.81 8.80 1.34 D632000200019 194.34 6.70 1.02 D632000200020 202.01 7.19 1.11 D632000200021 ENDDATA 13 0 D632000200022 ENDSUBENT 21 0 D632000299999 SUBENT D6320003 20190107 D119D632000300001 BIB 3 3 D632000300002 REACTION (60-ND-150(22-TI-48,FUS),,SIG,ER) D632000300003 SAMPLE (60-ND-150,ENR=0.9611) Target-thickness 150 ug/cm2. D632000300004 STATUS (TABLE) Table IV of Phys. Rev. C 96 (2017) 034613 D632000300005 ENDBIB 3 0 D632000300006 NOCOMMON 0 0 D632000300007 DATA 3 11 D632000300008 EN-CM DATA DATA-ERR D632000300009 MEV MB MB D632000300010 142.18 4.74 0.97 D632000300011 146.09 13.58 2.04 D632000300012 150.00 31.39 4.72 D632000300013 153.91 55.13 8.29 D632000300014 157.83 63.97 9.60 D632000300015 161.74 83.56 12.59 D632000300016 169.54 78.85 11.89 D632000300017 177.35 58.52 9.69 D632000300018 185.14 44.63 6.72 D632000300019 196.83 33.02 4.96 D632000300020 204.61 28.73 4.33 D632000300021 ENDDATA 13 0 D632000300022 ENDSUBENT 21 0 D632000399999 SUBENT D6320004 20190107 D119D632000400001 BIB 3 3 D632000400002 REACTION (62-SM-144(22-TI-48,FUS),,SIG,ER) D632000400003 SAMPLE (62-SM-144,ENR=0.9370) Target-thickness 120 ug/cm2. D632000400004 STATUS (TABLE) Table IV of Phys. Rev. C 96 (2017) 034613 D632000400005 ENDBIB 3 0 D632000400006 NOCOMMON 0 0 D632000400007 DATA 3 11 D632000400008 EN-CM DATA DATA-ERR D632000400009 MEV MB MB D632000400010 140.83 13.27 2.01 D632000400011 144.70 17.89 2.70 D632000400012 148.58 18.14 2.74 D632000400013 152.45 15.87 2.38 D632000400014 156.33 15.99 2.44 D632000400015 160.19 14.93 2.28 D632000400016 167.92 14.77 2.22 D632000400017 175.65 10.81 1.64 D632000400018 183.37 7.97 1.20 D632000400019 194.94 5.43 0.82 D632000400020 202.63 5.28 0.80 D632000400021 ENDDATA 13 0 D632000400022 ENDSUBENT 21 0 D632000499999 ENDENTRY 4 0 D632099999999