ENTRY D6313 20190405 D120D631300000001 SUBENT D6313001 20190405 D120D631300100001 BIB 9 34 D631300100002 TITLE Investigation of large alpha production in reactions D631300100003 involving weakly bound 7Li D631300100004 AUTHOR (S.K.Pandit, A.Shrivastava, K.Mahata, V.V.Parkar, D631300100005 R.Palit, N.Keeley, P.C.Rout, A.Kumar, K.Ramachandran, D631300100006 S.Bhattacharyya, V.Nanal, C.S.Palshetkar, T.N.Nag, D631300100007 S.Gupta, S.Biswas, S.Saha, J.Sethi, P.Singh, D631300100008 A.Chatterjee, S.Kailas) D631300100009 INSTITUTE (3INDTRM,3INDTAT,3POLIPJ,3INDVEC) D631300100010 (3INDIND) Homi Bhabha National Institute, Mumbai D631300100011 REFERENCE (J,PR/C,96,044616,2017) D631300100012 FACILITY (VDGT,3INDTRM) Pelletron-Linac facility D631300100013 SAMPLE Self-supporting 93Nb target foils of thickness ~ 1.6 D631300100014 mg/cm2. D631300100015 Aluminum catcher foils of thickness ~1 mg/cm2 were usedD631300100016 with each target foil to stop the recoiling residues. D631300100017 DETECTOR (TELES,SIBAR,SIBAR) Three Si surface barrier telescopesD631300100018 of thicknesses delta E ~ 15-30 um, E ~ 300-5000 um, D631300100019 were placed inside the scattering chamber at 35, 45 D631300100020 and 70 degree for the detection of charged particle D631300100021 around the grazing angle. D631300100022 (SIBAR) One Si surface barrier detector of thickness D631300100023 ~ 300 um was fixed at 20 degree to monitor Rutherford D631300100024 scattering for absolute normalization purposes. D631300100025 (HPGE) The off-line gamma ray counting was done using D631300100026 an efficiency calibrated HPGe detector. The in-beam D631300100027 gamma counting was done using the Indian National GammaD631300100028 Array (INGA) consisting 18 Compton suppressed HPGe D631300100029 clover detectors. D631300100030 ERR-ANALYS (DATA-ERR) Sources of error on data points were due D631300100031 to statistics, gamma-ray detection efficiency, and D631300100032 spectroscopic information of the residues. D631300100033 For off-beam measurements, uncertainty in the target D631300100034 thickness was also included. D631300100035 HISTORY (20190405C) VT D631300100036 ENDBIB 34 0 D631300100037 NOCOMMON 0 0 D631300100038 ENDSUBENT 37 0 D631300199999 SUBENT D6313002 20190405 D120D631300200001 BIB 3 3 D631300200002 REACTION (41-NB-93(3-LI-7,X)42-MO-95,,SIG) D631300200003 STATUS (TABLE) Fig. 3(a) of Phys. Rev. C, 96 (2017) 044616 D631300200004 PART-DET (G) Prompt gamma detection D631300200005 ENDBIB 3 0 D631300200006 NOCOMMON 0 0 D631300200007 DATA 3 4 D631300200008 EN DATA DATA-ERR D631300200009 MEV MB MB D631300200010 23.6 45.0 6.0 D631300200011 25.7 40.0 4.0 D631300200012 27.7 36.0 5.0 D631300200013 29.7 30.0 4.0 D631300200014 ENDDATA 6 0 D631300200015 ENDSUBENT 14 0 D631300299999 SUBENT D6313003 20190405 D120D631300300001 BIB 3 3 D631300300002 REACTION (41-NB-93(3-LI-7,X)42-MO-94,,SIG) D631300300003 STATUS (TABLE) Fig. 3(a) of Phys. Rev. C, 96 (2017) 044616 D631300300004 PART-DET (G) Prompt gamma detection D631300300005 ENDBIB 3 0 D631300300006 NOCOMMON 0 0 D631300300007 DATA 3 4 D631300300008 EN DATA DATA-ERR D631300300009 MEV MB MB D631300300010 23.6 185.8 15.0 D631300300011 25.7 195.8 17.0 D631300300012 27.7 207.0 22.0 D631300300013 29.7 211.0 25.0 D631300300014 ENDDATA 6 0 D631300300015 ENDSUBENT 14 0 D631300399999 SUBENT D6313004 20190405 D120D631300400001 BIB 4 5 D631300400002 REACTION (41-NB-93(3-LI-7,X)42-MO-93-M,,SIG) D631300400003 DECAY-DATA (42-MO-93-M,6.85HR,DG) D631300400004 METHOD (ACTIV) The target and catcher foil assemblies were D631300400005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631300400006 STATUS (TABLE) Fig. 3(a) of Phys. Rev. C, 96 (2017) 044616 D631300400007 ENDBIB 5 0 D631300400008 NOCOMMON 0 0 D631300400009 DATA 3 2 D631300400010 EN DATA DATA-ERR D631300400011 MEV MB MB D631300400012 27.7 0.06 0.01 D631300400013 29.7 0.60 0.08 D631300400014 ENDDATA 4 0 D631300400015 ENDSUBENT 14 0 D631300499999 SUBENT D6313005 20190405 D120D631300500001 BIB 4 5 D631300500002 REACTION (41-NB-93(3-LI-7,X)43-TC-96-G,,SIG) D631300500003 DECAY-DATA (43-TC-96-G,4.28D,DG) D631300500004 METHOD (ACTIV) The target and catcher foil assemblies were D631300500005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631300500006 STATUS (TABLE) Fig. 3(b) of Phys. Rev. C, 96 (2017) 044616 D631300500007 ENDBIB 5 0 D631300500008 NOCOMMON 0 0 D631300500009 DATA 3 4 D631300500010 EN DATA DATA-ERR D631300500011 MEV MB MB D631300500012 23.6 23.0 3.0 D631300500013 25.7 32.0 4.0 D631300500014 27.7 45.0 5.0 D631300500015 29.7 61.0 7.0 D631300500016 ENDDATA 6 0 D631300500017 ENDSUBENT 16 0 D631300599999 SUBENT D6313006 20190405 D120D631300600001 BIB 4 5 D631300600002 REACTION (41-NB-93(3-LI-7,X)43-TC-96-M,,SIG) D631300600003 DECAY-DATA (43-TC-96-M,51.5MIN,DG) D631300600004 METHOD (ACTIV) The target and catcher foil assemblies were D631300600005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631300600006 STATUS (TABLE) Fig. 3(b) of Phys. Rev. C, 96 (2017) 044616 D631300600007 ENDBIB 5 0 D631300600008 NOCOMMON 0 0 D631300600009 DATA 3 4 D631300600010 EN DATA DATA-ERR D631300600011 MEV MB MB D631300600012 23.6 17.7 3.0 D631300600013 25.7 20.1 4.0 D631300600014 27.7 26.0 4.5 D631300600015 29.7 36.1 5.0 D631300600016 ENDDATA 6 0 D631300600017 ENDSUBENT 16 0 D631300699999 SUBENT D6313007 20190405 D120D631300700001 BIB 4 5 D631300700002 REACTION (41-NB-93(3-LI-7,X)43-TC-95-G,,SIG) D631300700003 DECAY-DATA (43-TC-95-G,20.0HR,DG) D631300700004 METHOD (ACTIV) The target and catcher foil assemblies were D631300700005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631300700006 STATUS (TABLE) Fig. 3(b) of Phys. Rev. C, 96 (2017) 044616 D631300700007 ENDBIB 5 0 D631300700008 NOCOMMON 0 0 D631300700009 DATA 3 4 D631300700010 EN DATA DATA-ERR D631300700011 MEV MB MB D631300700012 23.6 0.40 0.06 D631300700013 25.7 0.70 0.10 D631300700014 27.7 2.30 0.20 D631300700015 29.7 5.10 0.40 D631300700016 ENDDATA 6 0 D631300700017 ENDSUBENT 16 0 D631300799999 SUBENT D6313008 20190405 D120D631300800001 BIB 4 5 D631300800002 REACTION (41-NB-93(3-LI-7,X)43-TC-95-M,,SIG) D631300800003 DECAY-DATA (43-TC-95-M,61.D,DG) D631300800004 METHOD (ACTIV) The target and catcher foil assemblies were D631300800005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631300800006 STATUS (TABLE) Fig. 3(b) of Phys. Rev. C, 96 (2017) 044616 D631300800007 ENDBIB 5 0 D631300800008 NOCOMMON 0 0 D631300800009 DATA 3 3 D631300800010 EN DATA DATA-ERR D631300800011 MEV MB MB D631300800012 25.7 0.28 0.04 D631300800013 27.7 0.45 0.09 D631300800014 29.7 0.75 0.09 D631300800015 ENDDATA 5 0 D631300800016 ENDSUBENT 15 0 D631300899999 SUBENT D6313009 20190405 D120D631300900001 BIB 3 3 D631300900002 REACTION (41-NB-93(3-LI-7,X)44-RU-98,,SIG) D631300900003 STATUS (TABLE) Fig. 3(c) of Phys. Rev. C, 96 (2017) 044616 D631300900004 PART-DET (G) Prompt gamma detection D631300900005 ENDBIB 3 0 D631300900006 NOCOMMON 0 0 D631300900007 DATA 3 4 D631300900008 EN DATA DATA-ERR D631300900009 MEV MB MB D631300900010 23.6 44. 8.5 D631300900011 25.7 22. 5.5 D631300900012 27.7 13. 2. D631300900013 29.7 4.2 0.5 D631300900014 ENDDATA 6 0 D631300900015 ENDSUBENT 14 0 D631300999999 SUBENT D6313010 20190405 D120D631301000001 BIB 6 8 D631301000002 REACTION (41-NB-93(3-LI-7,X)44-RU-97,,SIG) D631301000003 RAD-DET (44-RU-97,DG) D631301000004 METHOD (ACTIV) The target and catcher foil assemblies were D631301000005 irradiated for ~ 6 hours. The beam current was ~ 50 nA.D631301000006 ANALYSIS The weighted average values of the cross sections D631301000007 obtained from the in-beam and off-beam methods D631301000008 STATUS (TABLE) Fig. 3(c) of Phys. Rev. C, 96 (2017) 044616 D631301000009 PART-DET (G) Prompt gamma detection D631301000010 ENDBIB 8 0 D631301000011 NOCOMMON 0 0 D631301000012 DATA 3 4 D631301000013 EN DATA DATA-ERR D631301000014 MEV MB MB D631301000015 23.6 361. 35. D631301000016 25.7 423. 45. D631301000017 27.7 502. 47. D631301000018 29.7 478. 46. D631301000019 ENDDATA 6 0 D631301000020 ENDSUBENT 19 0 D631301099999 SUBENT D6313011 20190405 D120D631301100001 BIB 3 3 D631301100002 REACTION (41-NB-93(3-LI-7,X)44-RU-96,,SIG) D631301100003 STATUS (TABLE) Fig. 3(c) of Phys. Rev. C, 96 (2017) 044616 D631301100004 PART-DET (G) Prompt gamma detection D631301100005 ENDBIB 3 0 D631301100006 NOCOMMON 0 0 D631301100007 DATA 3 2 D631301100008 EN DATA DATA-ERR D631301100009 MEV MB MB D631301100010 27.7 40. 7. D631301100011 29.7 82. 15. D631301100012 ENDDATA 4 0 D631301100013 ENDSUBENT 12 0 D631301199999 SUBENT D6313012 20190405 D120D631301200001 BIB 3 3 D631301200002 REACTION (41-NB-93(3-LI-7,X)43-TC-97,,SIG) D631301200003 STATUS (TABLE) Fig. 3(c) of Phys. Rev. C, 96 (2017) 044616 D631301200004 PART-DET (G) prompt gamma counting D631301200005 ENDBIB 3 0 D631301200006 NOCOMMON 0 0 D631301200007 DATA 3 4 D631301200008 EN DATA DATA-ERR D631301200009 MEV MB MB D631301200010 23.6 48. 7. D631301200011 25.7 89. 13. D631301200012 27.7 142. 16. D631301200013 29.7 205. 25. D631301200014 ENDDATA 6 0 D631301200015 ENDSUBENT 14 0 D631301299999 ENDENTRY 12 0 D631399999999