ENTRY D6304 20190403 D120D630400000001 SUBENT D6304001 20190403 D120D630400100001 BIB 13 37 D630400100002 TITLE Measurement of 58Fe(p,n)58Co reaction cross-section D630400100003 within the proton energy range of 3.38 to 19.63 MeV D630400100004 AUTHOR (R.Ghosh, S.Badwar, B.Lawriniang, B.Jyrwa, H.Naik, D630400100005 Y.Naik, S.V.Suryanarayana, S.Ganesan) D630400100006 INSTITUTE (3INDNEH,3INDTRM) D630400100007 REFERENCE (J,NP/A,964,86,2017) D630400100008 FACILITY (VDGT,3INDTRM) 14 UD BARC-TIFER Pelletron facility D630400100009 SAMPLE Natural iron foils of 99.99% purity, 100 um thickness D630400100010 and having size 0.7 X 0.7 cm2. D630400100011 Natural copper foils of 99.99% purity, 108 um thicknessD630400100012 having size 0.8 X 0.8 cm2 used as energy degrader and D630400100013 monitor. D630400100014 The Al foil of 99.99% purity of thickness 108 um and D630400100015 size 0.8 X 0.8 cm2 used in the first position of the D630400100016 stack. D630400100017 DETECTOR (HPGE) The HPGe detector coupled to a PC based 4k D630400100018 channel analyzer. The detector resolution was 2.0 keV D630400100019 for 1332 keV gamma ray of 60Co. D630400100020 The dead time of detector always kept less than 10%. D630400100021 METHOD (ACTIV,STTA) The stack was irradiated for 30 minutes D630400100022 with a proton-beam of 21 MeV. The beam current was 28 D630400100023 nA constant during the irradiation. D630400100024 MONITOR (29-CU-0(P,X)30-ZN-62,,SIG) D630400100025 DECAY-MON (30-ZN-62,9.186HR,DG,507.60,0.148, D630400100026 DG,596.56,0.26) D630400100027 MONIT-REF (,F.Tarkanyi+,R,IAEA-TECDOC-1211,2001) D630400100028 ERR-ANALYS Overall uncertainty (4.9-8.6%) is from D630400100029 (ERR-S,2.2,7.4) Statistical uncertainty in counting D630400100030 statistics estimated (2.2-7.4%) D630400100031 (ERR-SYS) The systematic errors (~ 4.4%) are due to D630400100032 uncertainties in: D630400100033 (ERR-1) Proton flux estimation (2.5%) D630400100034 (ERR-2) Irradiation time (~ 0.5%) D630400100035 (ERR-3) Detector efficiency calibration (~ 3%) D630400100036 (ERR-4) Half life of reaction products and gamma-ray D630400100037 abundance (~ 2%) D630400100038 HISTORY (20190403C) VT D630400100039 ENDBIB 37 0 D630400100040 COMMON 7 6 D630400100041 EN-NRM MONIT ERR-SYS ERR-1 ERR-2 ERR-3 D630400100042 ERR-4 D630400100043 MEV MB PER-CENT PER-CENT PER-CENT PER-CENT D630400100044 PER-CENT D630400100045 18.21 46.248 4.4 2.5 0.5 3.D630400100046 2. D630400100047 ENDCOMMON 6 0 D630400100048 ENDSUBENT 47 0 D630400199999 SUBENT D6304002 20190403 D120D630400200001 BIB 5 10 D630400200002 REACTION (26-FE-58(P,N)27-CO-58,,SIG) D630400200003 SAMPLE (26-FE-58,NAT=0.0028) D630400200004 DECAY-DATA (27-CO-58-G,70.86D,DG,810.76,0.9945) D630400200005 ERR-ANALYS (ERR-5) Uncertainty due to precission based on D630400200006 replicate measurements. D630400200007 Haladhara Naik (2019-04-04): D630400200008 The total uncertainty has to be propagated based on D630400200009 the overall uncertainty (4.9-8.6%) and precision D630400200010 uncertainty. D630400200011 STATUS (TABLE) Table 2 of Nucl. Phys. A, 964 (2017) 86 D630400200012 ENDBIB 10 0 D630400200013 NOCOMMON 0 0 D630400200014 DATA 3 5 D630400200015 EN DATA ERR-5 D630400200016 MEV MB MB D630400200017 3.38 144.07 0.64 D630400200018 9.16 714.92 64.51 D630400200019 13.27 729.02 89.24 D630400200020 16.66 228.74 13.87 D630400200021 19.63 89.18 1.32 D630400200022 ENDDATA 7 0 D630400200023 ENDSUBENT 22 0 D630400299999 ENDENTRY 2 0 D630499999999